OMRON EE-1006-A

Slot-type Photomicrosensor (Non-modulated) *1
EE-SX47/67
CSM_EE-SX47_67_DS_E_3_1
Photomicrosensor with 50- to 100-mA direct
switching capacity for built-in application.
• Series includes models that enable switching between
dark-ON and light-ON operation.
• Response frequency as high as 1 kHz.
• Easy operation monitoring with bright light indicator.
• Wide operating voltage range: 5 to 24 VDC
• Models in which the light indicator turns ON for dark-ON
operation are also available.
• A wide range of variations in eight different shapes.
• Flexible robot cable is provided as a standard feature. *2
Be sure to read Safety Precautions on
page 5.
*1. Pre-wired Models are available only in the EE-SX67 Series.
*2. Only for Pre-wired Models and Pre-wired Connector Models.
Ordering Information
Connector
Appearance
Infrared light
Sensing Connectmethod ing method
Sensing distance
Standard
L-shaped
T-shaped,
slot center
7 mm
Closemounting
Closemounting
T-shaped,
slot center
10 mm
Throughbeam
type
(with slot)
Connector
(4 poles)
5 mm
(slot width)
Output
configuration
Indicator mode
Model
NPN output
PNP output
Dark-ON/Light-ON Incident light
(selectable) *3
No incident light
EE-SX670
EE-SX670P
EE-SX670A
EE-SX670R
Light-ON
EE-SX470
EE-SX470P
Dark-ON/Light-ON Incident light
(selectable) *3
No incident light
EE-SX671
EE-SX671P
EE-SX671A
EE-SX671R
Light-ON
EE-SX471
EE-SX471P
Dark-ON/Light-ON Incident light
(selectable) *3
No incident light
EE-SX672
EE-SX672P
EE-SX672A
EE-SX672R
Light-ON
EE-SX472
EE-SX472P
Incident light
Incident light
Incident light
Dark-ON/Light-ON Incident light
(selectable) *3
No incident light
EE-SX673
EE-SX673P
EE-SX673A
EE-SX673R
Light-ON
EE-SX473
EE-SX473P
Dark-ON/Light-ON Incident light
(selectable) *3
No incident light
EE-SX674
EE-SX674P
EE-SX674A
EE-SX674R
Light-ON
Incident light
EE-SX474
EE-SX474P
Dark-ON/Light-ON
Incident light
(selectable) *3
EE-SX675
EE-SX675P
Dark-ON/Light-ON
Incident light
(selectable) *3
EE-SX676
EE-SX676P
Dark-ON/Light-ON
Incident light
(selectable) *3
EE-SX677
EE-SX677P
Incident light
F-shaped
R-shaped
*3. Dark-ON when the L terminal of the connector is opened, and light-ON when the L terminal and positive (+) terminal are connected. Do not connect the L terminal
to 0 V when using dark-ON operation. When using light-ON, it is useful to select the connector EE-1001-1. The L terminal and positive (+) terminal of this connector
are connected in advance.
1
EE-SX47/67
Pre-wired Models, Models with Connectors
Appearance
Sensing
method
Sensing distance
Infrared light
Output
configuration
Indicator
mode
Connecting
method
Pre-wired
Models (1m)
Standard
Model
NPN output
EE-SX670-WR 1M
EE-SX670-C1J-R
Models with
connectors (0.1m) 0.1M
L-shaped
Pre-wired
Models (1m)
EE-SX671-WR 1M
EE-SX671-C1J-R
Models with
connectors (0.1m) 0.1M
Pre-wired
Models (1m)
T-shaped,
slot center
7 mm
EE-SX672-WR 1M
EE-SX672-C1J-R
Models with
connectors (0.1m) 0.1M
Pre-wired
Models (1m)
Closemounting
Throughbeam
type
(with slot)
Closemounting
Dark-ON/
Incident
Light-ON
(slot width) (selectable) * light
5 mm
EE-SX673-WR 1M
EE-SX673-C1J-R
Models with
connectors (0.1m) 0.1M
Pre-wired
Models (1m)
EE-SX674-WR 1M
EE-SX674-C1J-R
Models with
connectors (0.1m) 0.1M
Pre-wired
Models (1m)
T-shaped,
slot center
10 mm
EE-SX675-WR 1M
EE-SX675-C1J-R
Models with
connectors (0.1m) 0.1M
Pre-wired
Models (1m)
F-shaped
EE-SX676-WR 1M
EE-SX676-C1J-R
Models with
connectors (0.1m) 0.1M
Pre-wired
Models (1m)
R-shaped
EE-SX677-WR 1M
EE-SX677-C1J-R
Models with
connectors (0.1m) 0.1M
PNP output
EE-SX670P-WR
1M
EE-SX670P-C1J-R
0.1M
EE-SX671P-WR
1M
EE-SX671P-C1J-R
0.1M
EE-SX672P-WR
1M
EE-SX672P-C1J-R
0.1M
EE-SX673P-WR
1M
EE-SX673P-C1J-R
0.1M
EE-SX674P-WR
1M
EE-SX674P-C1J-R
0.1M
EE-SX675P-WR
1M
EE-SX675P-C1J-R
0.1M
EE-SX676P-WR
1M
EE-SX676P-C1J-R
0.1M
EE-SX677P-WR
1M
EE-SX677P-C1J-R
0.1M
* Dark-ON operation can be used when the L terminal is left unconnected or Light-ON operation can be used when the L terminal and positive (+) terminal are connected
to each other. Do not connect the L terminal to 0 V when using dark-ON operation.
Accessories (Order Separately) Connector Models
Type
Cable
length
Connector
1m
Connector with Cable
2m
Connector with Robot
Cable
1m
2m
Connector Hold-down Clip
Model
EE-1001
EE-1001-1
EE-1009
EE-1006
EE-1010
EE-1006
EE-1010
EE-1010-R
EE-1010-R
EE-1006A
Remarks
L terminal and positive (+) terminal are already short-circuited.
For EE-1006 only.
* Refer to Accessories for details.
Accessories (Order Separately) Models with Connectors
Type
Connector with Robot Cable
Cable
length
2m
Model
EE-1016-R-1
Remarks
For EE-SX67@-C1J-R only.
2
EE-SX47/67
Ratings and Specifications
Type
Standard
L-shaped
T-shaped,
slot center
7 mm
EE-SX672
EE-SX672A
EE-SX472
EE-SX672WR
EE-SX672CJ1-R
EE-SX672P
EE-SX672R
EE-SX472P
EE-SX672PWR
EE-SX672PCJ1-R
Close-mounting
T-shaped,
slot center
10 mm
EE-SX670
EE-SX671
EE-SX673
EE-SX674
Connector
EE-SX675
EE-SX670A
EE-SX671A
EE-SX673A
EE-SX674A
models
EE-SX470
EE-SX471
EE-SX473
EE-SX474
NPN
Pre-wired EE-SX670EE-SX671EE-SX673EE-SX674EE-SX675models
models WR
WR
WR
WR
WR
Models with EE-SX670EE-SX671EE-SX673EE-SX674EE-SX675connectors CJ1-R
CJ1-R
CJ1-R
CJ1-R
CJ1-R
EE-SX670P
EE-SX671P
EE-SX673P
EE-SX674P
Connector
EE-SX670R
EE-SX675P
EE-SX671R
EE-SX673R
EE-SX674R
models
EE-SX470P
EE-SX471P
EE-SX473P
EE-SX474P
PNP
Pre-wired EE-SX670PEE-SX671PEE-SX673PEE-SX674PEE-SX675Pmodels
models WR
WR
WR
WR
WR
Models with EE-SX670PEE-SX671PEE-SX673PEE-SX674PEE-SX675PItem
connectors CJ1-R
CJ1-R
CJ1-R
CJ1-R
CJ1-R
Sensing distance
5 mm (slot width)
Sensing object
Opaque: 2 × 0.8 mm min.
Differential distance
0.025 mm
Light source
GaAs infrared LED with a peak wavelength of 940 nm
Indicator *1
Light indicator (red) (turns ON when light is interrupted for models with A or R suffix)
Supply voltage
5 to 24 VDC ±10%, ripple (p-p): 10% max.
Current consumption
35 mA max. (NPN models), 30 mA max. (PNP models)
NPN open collector: 5 to 24 VDC, 100 mA max.
100 mA load current with a residual voltage of 0.8 V max.
40 mA load current with a residual voltage of 0.4 V max.
Control output
OFF current: 0.5 mA max.
PNP open collector: 5 to 24 VDC, 50 mA max.
50 mA load current with a residual voltage of 1.3 V max.
OFF current: 0.5 mA max.
Response frequency *2
1 kHz min. (3 kHz average)
Ambient illumination
1,000 lx max. with fluorescent light on the surface of the receiver.
Ambient temperature range Operating: −25 to +55°C, Storage: −30 to +80°C (with no icing or condensation)
Ambient humidity range
Operating: 5% to 85%, Storage: 5% to 95% (with no icing or condensation)
Destruction: 20 to 2,000 Hz (peak acceleration: 100 m/s2)
Vibration resistance
1.5-mm double amplitude for 2 h (4-min periods) each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions
Degree of protection
IEC60529 IP50
Connector Models (direct soldering possible), Pre-wired Models (Standard cable length: 1 m),
Connecting method
Models with Connectors (Standard cable length: 0.1 m)
Connector models
Approx. 3.1 g Approx. 3 g
Approx. 2.4 g Approx. 2.3 g Approx. 3 g
Approx. 2.7 g
Wei- Pre-wired models
Approx. 18.9 g Approx. 17.3 g Approx. 17.8 g Approx. 16.8 g Approx. 17.1 g Approx. 18.3 g
ght
Models with
Approx. 6.3 g Approx. 4.7 g Approx. 5.2 g Approx. 4.2 g Approx. 4.5 g Approx. 5.7 g
connectors
Case
Polybutylene phthalate (PBT)
Materi- Cover
Polycarbonate
al
Emitter/receiver
*1. The indicator is a GaP red LED (peak wavelength: 690 nm).
*2. The response frequency was measured by detecting the rotating disk
shown at the right.
F-shaped
R-shaped
EE-SX676
EE-SX677
EE-SX676WR
EE-SX676CJ1-R
EE-SX677WR
EE-SX677CJ1-R
EE-SX676P
EE-SX677P
EE-SX676PWR
EE-SX676PCJ1-R
EE-SX677PWR
EE-SX677PCJ1-R
Approx. 2.2 g Approx. 2.2 g
Approx. 16.9 g Approx. 16.9 g
Approx. 4.3 g
Approx. 4.3 g
Disk
1 mm
2.1 mm
1 mm
t = 0.2 mm
Connector for the EE-SX67 with Junction Connector
Product
Connector with Robot Cable
Model
EE-1016-R-1
Appearance
Item
Contact resistance
Insertion strength
Surplus strength
(housing holding strength)
Cable length
Ambient temperature range
Housing
Materials
Contact
25 mΩ max. (at 10 mA DC and 20 mV max.)
20 N max.
15 N min.
2m
−25 to +85°C
Nylon
Phosphor bronze
3
EE-SX47/67
Engineering Data (Typical)
Sensing Position Characteristics
Dark-ON
Tr ON
Repeated Sensing Position Characteristics
Dark-ON
Tr ON
d
Output level transistor
Sensing Position Characteristics
OFF
∆d2
∆d3
∆d1
∆d4
d
∆d5
d
ON
Tr OFF
0
1.0
2.0
3.0
4.0
5.0
Tr OFF
0
6.0
1.0
Distance d (mm)
2.0
3.0
4.0
5.0
6.0
Distance d (mm)
Ta = −25°C Ta = 55°C Ta = 25°C
0
3.00
3.02
3.04
3.06
3.08
Distance d (mm)
Vcc =12 V, No. of repetitions: 20, ∆d1 = 0.002 mm,
∆d2 = 0.004 mm, ∆d3 = 0.005 mm, ∆d4 = 0.02 mm,
∆d5 = 0.04 mm
Note: The data applies to dark status. Operation may
be affected by external light interference or light
coming through the sensing object.
I/O Circuit Diagrams
NPN Output
Model
Output
configuration
Timing charts
Terminal
connections
Output circuit
Incident
Interrupted
ON
OFF
ON
OFF
Operates
Light indicator
(red)
Light-ON
Output
transistor
Load 1
(e.g., relay) Releases
EE-SX67@
EE-SX67@-WR
EE-SX67@-CJ1-R
Load 2
Dark-ON
H
L
Incident
Interrupted
ON
Light indicator
(red)
OFF
ON
Output
transistor
OFF
Operates
Load 1
(e.g., relay) Releases
Load 2
Light-ON
ON
OFF
Operates
Load 1
(e.g., relay) Releases
H
Load 2
L
EE-SX670A
EE-SX671A
EE-SX672A
EE-SX673A
EE-SX674A
Incident
Interrupted
Light indicator
ON
(red)
OFF
Dark-ON
Output
transistor
ON
OFF
Operates
Load 1
(e.g., relay) Releases
Load 2
Open between
L terminal and
positive
terminal
*1
H
L
Incident
Interrupted
ON
Light indicator
(red)
OFF
Output
transistor
Short-circuited
between
L terminal and
positive
terminal
L
Main
circuit
Short-circuited
between
L terminal and
positive
terminal
*
Light indicator
(red)
Load
OUT
IC (Control output)
100 mA max.
5 to
24 VDC
*The terminal arrangement depends on the model.
Check the dimensional diagrams.
Open between
L terminal and
positive
terminal
*1
H
L
EE-SX470
EE-SX471
EE-SX472
EE-SX473
EE-SX474
Incident
Interrupted
ON
Light indicator
(red)
OFF
Light-ON
Output
transistor
Load 1
(relay)
Load 2
ON
OFF
Operates
Releases
H
L
Light indicator
(red)
Load
---
Main
circuit
OUT
IC
5 to
24 VDC
*1. Do not connect the L terminal to 0 V when using dark-ON operation.
4
EE-SX47/67
PNP Output
Output
configuration
Model
Timing charts
Terminal
connections
Output circuit
Incident
Interrupted
Light-ON
Light indicator
(red)
Output
transistor
Load
(relay)
EE-SX67@P
EE-SX67@P-WR
EE-SX67@P-CJ1-R
ON
OFF
ON
OFF
Operates
Short-circuited
between
L terminal and
positive
terminal
Releases
Incident
Interrupted
Dark-ON
Light indicator
(red)
Output
transistor
Load
(relay)
ON
OFF
ON
OFF
Operates
Open between
L terminal and
positive
terminal
*1
L
Releases
EE-SX670R
EE-SX671R
EE-SX672R
EE-SX673R
EE-SX674R
EE-SX470P
EE-SX471P
EE-SX472P
EE-SX473P
EE-SX474P
Light indicator
(red)
Output
transistor
ON
OFF
ON
OFF
Operates
5 to
24 VDC
OUT
IC
Main
circuit
Incident
Interrupted
Light-ON
*
Light indicator
(red)
Load
Short-circuited
between
L terminal and
positive
terminal
*The terminal arrangement depends on the model.
Check the dimensional diagrams.
Load
(e.g., relay) Releases
Dark-ON
Incident
Interrupted
ON
Light indicator
(red)
OFF
ON
Output
transistor
OFF
Operates
Load
(e.g., relay) Releases
Light-ON
Incident
Interrupted
ON
Light indicator
(red)
OFF
ON
Output
transistor
OFF
Operates
Load
(relay)
Releases
Open between
L terminal and
positive
terminal
*1
Light indicator (red)
---
Main
circuit
5 to
24 VDC
OUT
IC
Load
*1. Do not connect the L terminal to 0 V when using dark-ON operation.
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Precautions for Correct Use
Make sure that this product is used within the rated ambient
environment conditions.
● Installation
• When direct soldering to the terminals, use the following guidelines.
Precautions for Safe Use
● Operating Environment
These Photomicrosensors have an IP50 (conforms to IEC) enclosure
and do not have a water-proof or dust-proof structure. Therefore, do
not use them in applications in which the sensor will be subjected to
splashes from water, oil, or any other liquid. Liquid entering the
Sensor may result in malfunction.
Soldering Conditions
Item
Soldering
iron
Temper- Permissible
ature
time
350°C
max.
3 s max.
Remarks
The portion between the base of the
terminals and the position 1.5 mm from
the terminal base must not be soldered.
• The terminal base uses a polycarbonate resin, which could be
deformed by excessive soldering heat, resulting in damage to the
product's functionality.
● Lot Number and Model Number Legend
5
EE-SX47/67
In the following diagrams, 376d
indicates the lot number and factory
where the product was
manufactured. Do not include this
code with the model number when
ordering.
EE-SX@70@
Model number
EE-SX670
376d
Lot number and factory code
6
EE-SX47/67
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified.
Sensors
EE-SX670/670P
EE-SX670A/670R
EE-SX470/470P
EE-SX671/671P
EE-SX671A/671R
EE-SX471/471P
Terminal Arrangement
(1)
Vcc
Terminal Arrangement
(1)
Vcc
(2)
L
L*
(2)
L
L*
(3)
OUT
OUTPUT
(3)
OUT
OUTPUT
(4)
(4)
GND (0 V)
GND (0 V)
* Pin 2 is not used for the EE-SX471.
* Pin 2 is not used for the EE-SX470.
25.4
19
26.2
19
Two, 3.2 dia.
holes
6.95
Four, R2
3.2
14.5
3
Four, R1
19
13.4
5
Four, R1
3
6.4
0.8
6.2
3.8
Indicator window
9
Optical
axis
1
2
2
3
4
2.54
13
13.8
6.35
0.8
13.4
5
8.4
13.2
Two,
3.8 dia.
holes
Indicator window
5.5
6.2
3.8
1
2
9
Optical axis
Two, 3.2 dia. holes
8.3
9
2.1
7.2
3 4
2.54
0.3
0.7
2
15.5
0.3
7.2
6.2
0.7
3.6
13
13.4
0.6
6.95
19
7
EE-SX47/67
EE-SX672/672P
EE-SX672A/672R
EE-SX472/472P
Terminal Arrangement
(1)
Vcc
EE-SX673/673P
EE-SX673A/673R
EE-SX473/473P
Terminal Arrangement
(1)
Vcc
(2)
L
L*
(2)
L
L*
(3)
OUT
OUTPUT
(3)
OUT
OUTPUT
(4)
GND (0 V)
(4)
* Pin 2 is not used for the EE-SX472.
GND (0 V)
* Pin 2 is not used for the EE-SX473.
13.7
3
26
12.6
6.4
6.3
12.8
(6.65)
3.5
Two, R1
Two, 3.2 dia. holes
7
7
0.8
2
13.4
13.4
5
5
Optical axis
9
4.3
13
Optical axis
9
Indicator window
3
Four, R1.6 22.2
0.8
14.4
22.2
8.4
6.2
2
2.8
6.3
6.3
2.5
Four, R1
6.2
3.8
6.2
2.5
1
0.3
2 3
0.7
19
4.9
4
2.54
3.8
Indicator window
1
2 3
4
2.54
0.3
0.7
13
8
EE-SX47/67
EE-SX674/674P
EE-SX674A/674R
EE-SX474/474P
EE-SX675/675P
Terminal Arrangement
Terminal Arrangement
(1)
Vcc
(1)
Vcc
(2)
L
L*
(2)
L
L
(3)
OUT
OUTPUT
(3)
OUT
OUTPUT
GND (0 V)
(4)
(4)
GND (0 V)
* Pin 2 is not used for the EE-SX474.
16.7
4
Optical axis
Two, R1
Two, 3.5 dia. holes
7
6.35 26
Indicator window
7
10
21.5 6.95
3
0.8
3
Sensing
window
3.8
6.2
13.4
5
Optical axis
9
1
2
3
13
2.54
13
5
0.8 0.1
3.7
(R)
Optical axis
2.1
22.2
3.2
15.5
0.3
2.5
3.8
6.2
0.7
0.3
6.2
2.6
0.7
1
2
3
4
2.54
19.5
13
16.7
0.6
13.6
3
8.4
2
(9.3)
(R)
6
6.3
(2.9)
Indicator window
2
4
EE-SX676/676P
EE-SX677/677P
Terminal Arrangement
(1)
(1)
Vcc
(2)
L
L
(2)
L
L
(3)
OUT
OUTPUT
(3)
OUT
OUTPUT
GND (0 V)
(4)
(4)
13.7
Terminal Arrangement
Vcc
Optical axis
GND (0 V)
13.7
Optical axis
2.5
2.5
13.2
7
13.2
6.35
6.35
13.4
7
7
0.8
5
Optical axis
9
Indicator window
8.4
13.4
5
0.8
Optical axis
22.2
7
Sensing
window
2
9
3
13.6
9
2
22.2
Sensing
window
7
8.4
3
7 13.6
2.5
6.2
Indicator window
9
2.5
3.3
3.8
3.3
0.3
0.3
1 2 3 4
2.54
Two, 3.5 dia. holes
0.7
0.7
6.2
3.8
1 2 3 4
Two, 3.5 dia. holes
2.54
9
EE-SX47/67
EE-SX670-WR/670P-WR
EE-SX670-C1J-R/670P-C1J-R
EE-SX671-WR/671P-WR
EE-SX671-C1J-R/671P-C1J-R
Terminal Arrangement
Terminal Arrangement
Brown
(1)
Vcc
Brown
(1)
Pink
(2)
L
Pink
(2)
Vcc
L
Blue
(3)
GND (0 V)
Blue
(3)
GND (0 V)
Black
(4)
OUTPUT
Black
(4)
OUTPUT
9.4
2
9.4
2
26.2
R1
Optical axis
R3.5
17.4
4321
6.95
Optical axis
19
3.2
100±15
19
17.4
6.95
3
R1
18.7
3
3.2 dia.
43 21
100±15
Indicator window
EE-SX670-C1J-R
25.4
13.4
5
2
EE-SX671-C1J-R
6.35
Optical axis
0.8
Robot cable of 2.8 dia., 4 cores,
(0.15 mm2 with 0.8 mm dia. insulator);
Standard length: 1 m
13.4
2
9
11.2
8.4
26.2
13.4
5
Sensing
window
13.8
3
6.35
Optical axis
Sensing
window
11
5.5
2.5
15.5
Indicator window
2.8
4.6 dia.
6.2
7.2
3.8 dia.
4.6 dia.
2
2
9
9
0.8
Robot cable of 2.8 dia., 4 cores,
(0.15 mm2 with 0.8 mm dia. insulator);
Standard length: 1 m
3.6
EE-SX672-WR/672P-WR
EE-SX672-C1J-R/672P-C1J-R
19
3.2 dia.
EE-SX673-WR/673P-WR
EE-SX673-C1J-R/673P-C1J-R
Terminal Arrangement
Terminal Arrangement
Brown
(1)
Vcc
Brown
(1)
Pink
(2)
L
Pink
(2)
Vcc
L
Blue
(3)
GND (0 V)
Blue
(3)
GND (0 V)
Black
(4)
OUTPUT
Black
(4)
OUTPUT
9.4
9.4
2
2
13.7
7
17.4
17.4
43 21
4321
Optical axis
12.6
6.3
12.8
Optical axis
100±15
7
5
13.4
5
0.8
Optical axis
2
2.5
13
Indicator
window
26.2
14.4
2.5
2
4.6 dia.
19
2 dia.
2
Sensing
window
8.4
8.9
R1
0.8
Optical axis
26.2
6.2
10.3
EE-SX673-C1J-R
9
9
4.3
R1.6
3.2 dia.
13.4
6.35
Sensing
window
100±15
R1
3
EE-SX672-C1J-R
(6.65)
3.5
Robot cable of 2.8 dia., 4 cores,
(0.15 mm2 with 0.8 mm dia. insulator);
Standard length: 1 m
2.8
Indicator window
3
2
Robot cable of 2.8 dia., 4 cores,
(0.15 mm2 with 0.8 mm dia. insulator);
Standard length: 1 m
4.6 dia.
26
10
EE-SX47/67
EE-SX675-WR/675P-WR
EE-SX675-C1J-R/675P-C1J-R
EE-SX674-WR/674P-WR
EE-SX674-C1J-R/674P-C1J-R
Terminal Arrangement
Terminal Arrangement
Brown
(1)
Vcc
Brown
(1)
Pink
(2)
L
Pink
(2)
Vcc
L
Blue
(3)
GND(0V)
Blue
(3)
GND(0V)
Black
(4)
OUTPUT
Black
(4)
OUTPUT
9.4
2
17.4
3.5 dia.
R1
7
10
Optical axis
43 21
9.4
6.35 26
2
7
100±15
7
4
6.95
17.4
25.7
EE-SX675-C1J-R
4321
Optical axis 3
3
13.4
5
19.5
0.8
100±15
Sensing
window
2
Optical axis
2
Indicator window
9
EE-SX674-C1J-R
Robot cable of 2.8 dia., 4 cores,
(0.15 mm2 with 0.8 mm dia. insulator);
Standard length: 1 m
(R)
5
6 3.2
0.8
Sensing
window
(2.9)
3.7
2.5
10.3
(R)
2
9
3
26.2 8.4
13.6
Optical axis
Indicator window
13
4.6 dia.
2
15.5
4.6 dia.
Robot cable of 2.8 dia., 4 cores,
(0.15 mm2 with 0.8 mm dia. insulator);
Standard length: 1 m
2.6
6.2
2.8
13.4
16.7
EE-SX676-WR/676P-WR
EE-SX676-C1J-R/676P-C1J-R
EE-SX677-WR/677P-WR
EE-SX677-C1J-R/677P-C1J-R
Terminal Arrangement
Terminal Arrangement
Brown
(1)
Vcc
Brown
(1)
Pink
(2)
L
Pink
(2)
Vcc
L
Blue
(3)
GND(0V)
Blue
(3)
GND(0V)
Black
(4)
OUTPUT
Black
(4)
OUTPUT
9.4
9.4
2
2
17.4
17.4
43 21
43 21
Optical axis
100±15
100±15
2.5
Optical axis
2.5
7
EE-SX676-C1J-R
13.7
7
EE-SX677-C1J-R
13.7
13.2
6.4
13.2
Optical axis
6.4
13.4
5
7
9
8.4
3
Sensing
window
13.4
5
Indicator window
9
9
0.8
26.2 8.4
26.2
13
Optical axis
2
2
0.8
9
Sensing
window
7
7
7
2.5
2.5
3
13
3.3
3.3
Indicator window
2
4.6 dia.
4
4
3.5 dia.
Robot cable of 2.8 dia., 4 cores,
(0.15 mm2 with 0.8 mm dia. insulator);
Standard length: 1 m
3.5
4.6 dia.
2
Robot cable of 2.8 dia., 4 cores,
(0.15 mm2 with 0.8 mm dia. insulator);
Standard length: 1 m
Accessories (Order Separately)
Connector for the EE-SX67 with Junction Connector
11
EE-SX47/67
EE-1016-R-1
8
5.8
10
2
10
2,000
16
4
3
2
1
Terminal Arrangement
(1)
(2)
Robot cable of 2.8 dia., 4 cores,
(0.15 mm2 with 0.8 mm dia. insulator);
Standard length: 2 m
Brown
L
(3)
(4)
Pink
Blue
OUT
Black
* Refer to Accessories for details.
12
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.