PRODUCT FEATURES
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Hot pluggable X2 MSA form factor
Total power consumption: 2.2 W
maximum
RoHS-6 compliant (lead-free)
Temperature range 0°C to 70°C
Transmission distance of 300m
Uncooled 850 nm VCSEL laser
SC connector, multimode fiber
Full duplex transmission mode
Digital Optics Monitoring (DOM)
Power supply: +5.0 V, +3.3 V
Adaptable Power Supply (APS:
+1.2 V)
XAUI electrical interface
4x 3.125 Gb/s Ethernet
(FTLX8541E2)
4x 3.1875 Gb/s Fibre Channel
(FTLX8541F2)
Management and control via MDIO
2-wire bus
70-pin connector
Separated signal/chassis ground
Mid Pak module variance for front
panel mounting
De-latch mechanism with low
extraction force
APPLICATIONS
ƒ
ƒ
10GBASE-SR 10G Ethernet
(FTLX8541E2)
1200-Mx-SN-I 10G Fibre Channel:
(FTLX8541F2)
PRODUCT SELECTION
Part Number
Applications
FTLX8541E2
10G Ethernet
FTLX8541F2
10G Fibre Channel
© Finisar Corporation – November 28, 2007 Rev. B
Page 1
FTLX8541 Product Specification – November 2007
I. Pin Descriptions
Signal Name
Level
I/O
Management and Monitoring Ports
MDIO
Open Drain
I/O
Pin No.
Description
17
MDC
I
18
Management Data I/O. Requires
external 10 - 22 kΩ pull-up to the
APS on host.
Management Data Clock Input
1
19
Port Address Input bit 4
I
20
Port Address Input bit 3
I
21
Port Address Input bit 2
I
22
Port Address Input bit 1
I
23
Port Address Input bit 0
LASI
1.2 V
CMOS
1.2 V
CMOS
1.2 V
CMOS
1.2 V
CMOS
1.2 V
CMOS
1.2 V
CMOS
Open Drain
O
9
RESET
Open Drain
I
10
Link Alarm Status Interrupt Output.
Open Drain Compatible Output with
10 - 20 kΩ pull-up on host.
Logic high = Normal Operation
Logic low = Status Flag Triggered
Reset Input.
Open Drain Compatible Input with
22 kΩ pull-up to APS internal to
transponder.
Logic high = Normal Operation
Logic low = RESET
Vendor Specific Pins.
Leave unconnected when not used.
TX ON/OFF Input.
Open Drain Compatible Input with
22 kΩ pull-up to APS internal to
transponder.
Logic high = Transmitter On
Logic low = Transmitter Off
Pulled low inside transponder
through a 1 kΩ resistor to Ground
PRTAD4
PRTAD3
PRTAD2
PRTAD1
PRTAD0
Vendor Specific
TX ON/OFF
11,15,16,24
Open Drain
MOD DETECT
Transmit Functions
Reserved
Reserved
TX LANE 3–
AC-coupled,
TX LANE 3+
Internally biased
differential
TX LANE 2–
XAUI
TX LANE 2+
TX LANE 1–
TX LANE 1+
TX LANE 0–
TX LANE 0+
I
12
O
14
I
I
I
I
68
67
65
64
Reserved For Future Use
Reserved For Future Use
Module XAUI Input Lane 3–
Module XAUI Input Lane 3+
I
I
I
I
I
I
62
61
59
58
56
55
Module XAUI Input Lane 2–
Module XAUI Input Lane 2+
Module XAUI Input Lane 1–
Module XAUI Input Lane 1+
Module XAUI Input Lane 0–
Module XAUI Input Lane 0+
© Finisar Corporation – November 28, 2007 Rev. B
Page 2
FTLX8541 Product Specification – November 2007
Receive Functions
Reserved
Reserved
RX LANE 0+
AC-coupled,
RX LANE 0–
Internally biased
differential
RX LANE 1+
XAUI
RX LANE 1–
RX LANE 2+
RX LANE 2–
RX LANE 3+
RX LANE 3–
DC Power
GND
0 V DC
APS
APS SENSE
+1.2 V
+1.2 V
O
O
O
O
38
39
41
42
Reserved For Future Use
Reserved For Future Use
Module XAUI Output Lane 0+
Module XAUI Output Lane 0–
O
O
O
O
O
O
44
45
47
48
50
51
Module XAUI Output Lane 1+
Module XAUI Output Lane 1–
Module XAUI Output Lane 2+
Module XAUI Output Lane 2–
Module XAUI Output Lane 3+
Module XAUI Output Lane 3–
1, 2, 3, 33, 34,
35, 36, 37, 40,
43, 46, 49, 52,
53, 54, 57, 60,
63, 66, 69, 70
7, 8, 28, 29
27
Ground connection for signal ground
on the module
APS SET
25
3.3 V
+3.3 V DC
5, 6, 30, 31
5.0 V
+5.0 V DC
4, 32
Reserved
Reserved
© Finisar Corporation – November 28, 2007 Rev. B
26
13
Input from Adaptive Power Supply
APS Sense Output. Connected to the
APS input inside transponder.
Feedback input from APS.
Connected to GND through a 1180Ω
resistor inside the transponder.
DC Power Input, +3.3 V DC,
Nominal
DC Power Input, +5.0 V DC,
Nominal
Reserved for APD.
Reserved.
Page 3
FTLX8541 Product Specification – November 2007
Electrical Pad Layout
Fig 1-X2 Transponder Electrical Pad Layout
II. Absolute Maximum Ratings
Parameter
Storage Ambient Temperature1)
Operating Case Temperature1)
Supply Voltage +5.0 V
Supply Voltage +3.3 V
Supply Voltage APS
Static Discharge Voltage, All Pins2)
Average Receive Optical Power
Notes:
1)
2)
Symbol
TS
TC
V5
V3
Vaps
STd
RxP max
Limit Values
min.
max.
-40
85
0
70
0
6
0
4
0
1.5
500
1.5
Unit
°C
°C
V
V
V
V
dBm
Non-condensing.
HBM.
Exceeding any one of these values may permanently destroy the device.
© Finisar Corporation – November 28, 2007 Rev. B
Page 4
FTLX8541 Product Specification – November 2007
III. Electrical Characteristics
Recommended Operating Conditions
Parameter
Operating Case Temperature1)
Transponder Total Power
Consumption
Supply Voltage +5.0 V
Supply Current +5.0 V
Supply Voltage +3.3 V
Supply Current +3.3 V
Supply Voltage APS
Supply Current APS
Symbol
TC
P
min.
0
VCC5
ICC5
VCC3
ICC3
VCC aps
ICC aps
4.75
3.14
1.152
Values
typ.
5.0
157
3.3
55
1.2
830
max.
70
2.2
Unit
°C
W
5.25
190
3.47
72
1.248
850
V
mA
V
mA
V
mA
1)
Measured at reference thermal location, see Figure 2.
See also Environmental Performance.
Electrical DC Characteristics
(VCC5 = 4.75 V to 5.25 V, VCC3 = 3.14 V to 3.47 V, VCC aps = 1.152 V to 1.248 V, TC = 0°C to 70°C)
Parameter
Symbol
min.
1.2 V CMOS (1.8 V CMOS Compatible1)) I/O DC Characteristics
(PRTAD; LASI; RESET; TX_ONOFF)
External Pull-up Resistor for Open Drain
Rpullup
10
Output High Voltage2)
Voh
1
Output Low Voltage2)
Vol
Input High Voltage
Vih
0.84
Input Low Voltage
Vil
Input Pull-down Current3)
Ipd
20
XAUI I/O DC Characteristics (TXLANE[0..3]; RXLANE[0..3])
Values
typ.
max.
Unit
22
0.15
1.5
0.36
120
kΩ
V
V
V
V
µA
Differential Input Amplitude (pk-pk) 4)
Vin_xaui
Differential Output Amplitude (pk-pk) 4)
Vout_xaui
MDIO I/O DC Characteristics (MDIO; MDC)
200
800
2500
1600
mV
mV
Output Low Voltage5)
Output Low Current
Input High Voltage
Input Low Voltage
Pull-up Supply Voltage
Input Capacitance
Load Capacitance
External Pull-up Resistance
–0.3
0.2
20
1.5
0.36
1.5
10
470
V
mA
V
V
V
pF
pF
Ω
1)
2)
3)
4)
5)
VOL
IOL
VIH
VIL
VPU
CIN
CLOAD
RLOAD
0.84
–0.3
0.84
200
1.2
For 1.8 V CMOS Voh = 1.65 V min., Vol = 0.15 V max., Vih = 1.17 V min., Vil = 0.63 V max.
Rpull-up = 10 kΩ to 1.8 V.
Vin = 1.8 V.
AC coupled.
IOL = 100 µA
.
© Finisar Corporation – November 28, 2007 Rev. B
Page 5
FTLX8541 Product Specification – November 2007
Electrical AC Characteristics
(VCC5 = 4.75 V to 5.25 V, VCC3 = 3.14 V to 3.47 V, VCC aps = 1.152 V to 1.248 V, TC = 0°C to 70°C)
Values
Parameter
Symbol
Unit
min.
typ.
max.
XAUI Input AC Characteristics (TXLANE[0..3])
Baud Rate
RXAUIIN
Gbit/s
Fibre Channel
3.1875
Ethernet
3.125
Baud Rate Tolerance
RTOLXAUI
–100
100
ppm
Differential Input Impedance
ZINXAUI
80
100
120
Ω
Differential Return Loss1)
|S11|
10
dB
Input Differential Skew2)
tSKEWIN
75
ps
Jitter Amplitude Tolerance3)
JXAUITOL
0.65
UIp-p
XAUI Output AC Characteristics (RXLANE[0..3])
Baud Rate
RXAUIOUT
Gbit/s
Fibre Channel
3.1875
Ethernet
3.125
Baud Rate Variation
RXAUIVAR
–100
100
ppm
XAUI Eye Mask (far-end)
According to IEEE 802.3ae and 10G Fibre Channel
Output Differential Skew
tSKEWOUT
15
ps
Output Differential Impedance
ZOUTXAUI
80
100
120
Ω
Differential Output Return Loss1)
|S22|
10
dB
Total Jitter4)
TJXAUI
0.35
UI
Deterministic Jitter4)
DJXAUI
0.37
UI
Power-On Reset AC Characteristics
Power-On Reset and TX_ONOFF
According to XENPAK MSA Issue 3.0, 2002-9-18
Characteristics
MDIO I/O AC Characteristics (MDIO; MDC)
MDIO Data Hold Time
tHOLD
10
ns
MDIO Data Setup Time
tSU
10
ns
Delay from MDC Rising Edge to
tDELAY
300
ns
MDIO Data Change
MDC Clock Rate
ƒMAX
2.5
MHz
1)
2)
3)
4)
100 MHz to 2.5 GHz.
At crossing point.
Per IEEE Std 802.3ae.
At near-end, No pre-equalization, 1 UI = 320 ps.
© Finisar Corporation – November 28, 2007 Rev. B
Page 6
FTLX8541 Product Specification – November 2007
IV. Optical Characteristics
(VCC5 = 4.75 V to 5.25 V, VCC3 = 3.14 V to 3.47 V, VCC aps = 1.152 V to 1.248 V, TC = 0°C to 70°C, BER
1E-12, Bit Rate 10.3125)
Values
Parameter
Symbol
Unit
min.
typ.
max.
Transmitter
Launch Power in OMA1)
PO-OMA
–2.8
–1.5
dBm
Average Launch Power
PO-Avg
–5
–1
dBm
TDP
TDP
3.9
dB
Center Wavelength Range1)
λC-Tx
840
850
860
nm
RMS Spectral Width1)
0.4
0.45
nm
σI
Extinction Ratio
ER
3
5.5
dB
Relative Intensity Noise12OMA
RIN
–128
dB/Hz
Eye Mask Definition
According to IEEE and Fibre Channel
Encircled Flux
EF
at 19 µm ≥86%, at 4.5 µm ≤ 30%
Optical Return Loss Tolerance
ORLT
12
dB
Average Launch Power of OFF
PO-OFF
–30
dBm
Transmitter
Receiver
Stressed Receiver Sensitivity in OMA
PIN-S
–7.5
dBm
Receiver Sensitivity in OMA2)
PIN
–11.1
dBm
Average Receive Power
PIN-max
-1
dBm
Signal Detect Deassert Level
PSDL
–14.5
dBm
Signal Detect Assert Level
PSD
–18.0
dBm
Signal Detect Hysteresis
PSD
0.5
1.5
dB
Receiver Reflectance
REFRX
–12
dB
Center Wavelength Range
λC-RX
840
860
nm
1)
2)
Conforms to IEEE triple trade-off between center wavelength, RMS spectral width and minimum OMA.
Receiver sensitivity, which is defined for an ideal input signal is informative only.
V. General Specifications
Optical Interface Standard Specifications
Standard
IEEE
Fibre
Channel
Fiber Type
62.5 µm MMF
50 µm MMF
62.5 µm MMF
50 µm MMF
50 µm MMF
Minimum Modal Bandwidth at
850 nm (MHz*km)
160
400
200
500
2000
Operating Range 1)
(meters)
2 to 26
2 to 66
0.5 to 33
0.5 to 82
0.5 to 300
Notes:
1) Operating range as defined by IEEE and Fibre Channel standards. Longer reach possible depending upon link implementation.
© Finisar Corporation – November 28, 2007 Rev. B
Page 7
FTLX8541 Product Specification – November 2007
Environmental Performance
Operating case temperature:
Operating humidity:
0°C to +70°C
0% -95% RH non-condensing
Fibers and Connectors
The transponder has SC receptacles for both Tx and Rx. The transponder is designed for
multimode SC cables, 0° polished endface (PC).
70-pin Connector
The module interface connector is a 70-pin, printed circuit board edge connection with a
0.5 mm pitch. The appropriate mating connector for the customer PCB is a 70-pin SMT,
dual row, right angled, edge connector, 0.5 mm pitch (Tyco Electronics part number
1367337-1, Molex part number 74441-0003 or equivalent).
Rail and Mechanical Mounting Requirements
The X2 rail system required to mount the X2 module is fully defined by the MSA.
(Tyco Electronics part number 1367608-1: designed for belly to belly applications;
and 1367610-1, designed for single sided board mount to fit into the standard host PCB
footprint; or equivalent). For further details please refer to vendor-supplied information.
Aqueous Wash
Finisar X2 transponders are neither solderable nor aqueous washable and are not
intended for these processes.
VI. Regulatory Compliance
Feature
ESD:
Electrostatic Discharge to the
Electrical Pins (HBM)
Immunity:
Against Electrostatic Discharge
(ESD) to the Module Receptacle
Standard
EIA/JESD22-A114-B
(MIL-STD 883D
Method 3015.7)
EN 61000-4-2
IEC 61000-4-2
Immunity:
Against Radio Frequency
Electromagnetic Field
EN 61000-4-3
IEC 61000-4-3
Emission:
Electromagnetic Interference
(EMI)
FCC 47 CFR
Part 15, Class B
EN 55022 Class B
CISPR 22
© Finisar Corporation – November 28, 2007 Rev. B
Comments
Class 1a (> 500 V)
Discharges ranging from ±2 kV to ±25 kV to
the front end / faceplate / receptacle cause no
damage to module (under recommended
conditions).
With a field strength of 10 V/m, noise
frequency ranges from 10 MHz to 2 GHz. No
effect on module performance between the
specification limits.
Noise frequency range:
30 MHz to 40 GHz
Radiated emission does not exceed specified
limits when measured with module inside a
shielding enclosure with a MSA conforming
cutout.
Page 8
FTLX8541 Product Specification – November 2007
Eye Safety
Finisar FTLX8541 transponders are Class 1 Laser Products. They are certified per the
following standards:
Feature
Agency
Standard
Laser Eye
Safety
Laser Eye
Safety
FDA/CDRH
CDRH 21 CFR 1040 and Laser Notice 50
TÜV
Electrical
Safety
Electrical
Safety
TÜV
EN 60825-1: 1994+A11:1996+A2:2001
IEC 60825-1: 1993+A1:1997+A2:2001
IEC 60825-2: 2000, Edition 2
EN 60950
UL/CSA
CLASS 3862.07
CLASS 3862.87
Certificate
Number
9210176-77
R 72052602
R 72052602
1439230
Copies of the referenced certificates will be available at Finisar Corporation upon
request.
VII. DOM Parameters
Parameter
Transponder Temperature Monitor Accuracy1)
Laser Bias Current Monitor Accuracy2)
Transmit Power Monitor Accuracy3)
Receive Power Monitor Accuracy3)
1)
2)
3)
min.
-5
-10
-3
-3
Values
typ.
max.
+5
+10
+3
+3
Unit
°C
%
dB
dB
0 to 70°C case temperature.
0 to 12.5 mA.
-8.2 dBm to +0.5 dBm.
VIII. Mechanical Specifications
Parameter
Symbol
min.
Module Retention Force (latch strength)
Module Insertion Force
Module Extraction Force (with kick-out)
Module Extraction Force (without kick-out)
FRET
FIN
FEXT-K
FEXT
Values
typ.
200
40
16
25
Unit
max.
N
N
N
N
Pull Sleeve front face color is beige.
© Finisar Corporation – November 28, 2007 Rev. B
Page 9
FTLX8541 Product Specification – November 2007
Package Outline
Figure 2 - X2 Mechanical Dimensions
IX. References
Optical Interface Standard Specifications References
ƒ
ƒ
ƒ
ƒ
ƒ
IEEE Std 802.3ae-2002 clause 52, 10GBASE-SR
Fibre Channel 10GFC Draft 4.0, 1200-M5-SN-I
Fibre Channel 10GFC Draft 4.0, 1200-M5E-SN-I
Fibre Channel 10GFC Draft 4.0, 1200-M6-SN-I
X2 MSA Issue 2.0b
Electrical Interface Standard Specifications References
ƒ
ƒ
IEEE Std 802.3ae-2002 clause 45 & 47
X2 MSA Issue 2.0b
X. For More Information
Finisar Corporation
1389 Moffett Park Drive
Sunnyvale, CA 94089-1133
Tel. 1-408-548-1000
Fax 1-408-541-6138
[email protected]
www.finisar.com