Power Relay ■ ■ ■ ■ ■ G4W Impulse withstand voltage of 10,000V between input and output (coil and contact) Creepage distance of 10 mm (0.39 in) minimum between coil and contact meets VDE C/250 Dielectric strength of 4,000 VAC minimum conforms to UL, CSA and IEC Class II International 2.5 mm (0.10 in) terminal pitch Low power consumption (0.8W) DVE Ordering Information To Order: Select the part number and add the desired coil voltage rating (e.g., G4W-1112P-US-TV8-HP-DC12). Type PCB Solder Quick connect Contact form SPST-NO DPST-NO SPST-NO DPST-NO SPST-NO DPST-NO SPST-NO DPST-NO Construction Unsealed Sealed Upper mounting bracket Upper mounting bracket Part number G4W-1112P-US-TV8-HP G4W-2212P-US-TV5-HP G4W-1114P-US-TV8-HP G4W-2214P-US-HP G4W-11123A-US-TV8-HP G4W-22123A-US-TV5-HP G4W-11123T-US-TV8-HP G4W-22123T-US-TV5-HP Specifications ■ CONTACT DATA Type Load Rated load Contact material Carry current Max. operating voltage Max. operating current Max. switching capacity Min. permissible load SPST-NO Resistive (p.f. = 1) 15 A at 250 VAC, 24 VDC AgCdO 15 A 250 VAC, 125 VDC 15 A 3,750 VA 500 mA, 5 VDC Inductive (p.f. = 0.4) 10 A at 250 VAC, 24 VDC DPST-NO Resistive (p.f. = 1) 15 A at 250 VAC, 24 VDC Inductive (p.f. = 0.4) 7.5 A at 250 VAC, 24 VDC 2,500 VA 3,750 VA 1,875 VA G4W G4W ■ COIL DATA Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) 12 18 24 100 66.70 44.40 33.30 8 180 405 720 12,500 Coil inductance (Ref. value) (H) Armature OFF 0.93 1.90 3.70 61.80 Pick-up voltage Armature ON 1.65 3.30 6.40 106 Dropout voltage % of rated voltage 80% max. 10% min. Maximum voltage Power consumption (mW) 110% max. Approx. 800 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%. 2. The operating characteristics are measured at a coil temperature of 23°C (73°F). ■ CHARACTERISTICS Contact resistance Operate time Release time Bounce time Operating frequency Mechanical Electrical Insulation resistance Dielectric strength Impulse dielectric strength Vibration Mechanical durability Malfunction durability Shock Mechanical durability Malfunction durability Ambient temperature Operating Storage Humidity Service life Mechanical Electrical Weight 30 mΩ 20 ms max. (mean value: approx. 13 ms) 5 ms max. (mean value: approx. 2.50 ms) Operate: approx. 0.40 ms 18,000 operations/hour 1,800 operations/hour (under rated load) 100 MΩ min. (at 500 VDC) 4,000 VAC, 50/60 Hz for 1 minute between coil and contacts 2,000 VAC, 50/60 Hz for 1 minute between contacts of different poles 1,500 VAC, 50/60 Hz for 1 minute between contacts of same pole 10,000 VAC, 1.20 x 50µs (between coil and contacts) 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude range 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude range 1,000 m/s2 (approx. 100 G) 150 m/s2 (approx. 15 G) -25° to 55°C (-13° to 131°F) -25° to 55°C (-13° to 131°F) 35% to 85% RH 5,000,000 operations min. (at operating frequency of 18,000 operations/hour) See “Characteristic Data” 29 g (1.02 oz) Note: Data shown are of initial value. ■ CHARACTERISTIC DATA Rated operating current (A) Rated operating voltage (V) 2 Electrical service life SPST-NO, DPST-NO Service life (x103 operations) Maximum switching capacity SPST-NO, DPST-NO Rated operating current (A) G4W G4W Dimensions Unit: mm (inch) ■ RELAYS G4W-■ ■ ■ 12P-US-TV■ ■ -■ ■■ G4W-1112P-US-TV8-HP G4W-1114P-US-TV8-HP G4W-2212P-US-TV5-HP G4W-2214P-US-HP Mounting holes (Bottom view) Mounting holes (Bottom view) Terminal layout/Internal connections (Bottom view) Terminal layout/Internal connections (Bottom view) G4W-■ ■ ■ 123A-US-TV■ ■ -HP G4W-11123A-US-TV8-HP G4W-22123A-US-TV5-HP G4W-■ ■ ■ 123T-US-TV■ ■ -HP G4W-11123T-US-TV8-HP G4W-22123T-US-TV5-HP 3 G4W G4W ■ APPROVALS UL (File No. E41643) Type G4W-1112P-US-TV8-HP G4W-11123A-US-TV8-HP G4W-11123T-US-TV8-HP G4W-1114P-US-TV8-HP Contact form SPST-NO Coil ratings 6 to 120 VDC G4W-2212P-US-TV5-HP G4W-22123A-US-TV5-HP G4W-22123T-US-TV5-HP G4W-2214P-US-HP DPST-NO 6 to 120 VDC Type G4W-1112P-US-TV8-HP G4W-11123A-US-TV8-HP G4W-11123T-US-TV8-HP G4W-1114P-US-TV8-HP Contact form SPST-NO Coil ratings 6 to 120 VDC G4W-2212P-US-TV5-HP G4W-22123A-US-TV5-HP G4W-22123T-US-TV5-HP G4W-2214P-US-HP DPST-NO 6 to 120 VDC Contact ratings 15 A, 250 VAC (General use) 15 A, 24 VDC TV-8 1/2 HP, 125 VAC 1 HP, 250 VAC 3/4 HP, 240 VAC 15 A, 250 VAC (General use) 10 A, 250 VAC (General use) 15 A, 24 VDC TV-5 1/4 HP, 125 VAC 1/2 HP, 250 VAC 1/3 HP, 125 VAC 1/3 HP, 250 VAC CSA (File No. LR31928) Contact ratings 15 A, 150 VAC (General use) 15 A, 24 VDC TV-8 1/2 HP, 125 VAC 3/4 HP, 240 VAC 1 HP, 250 VAC 15 A, 250 VAC (General use) – same polarity 10 A, 250 VAC (General use) 15 A, 24 VDC TV-5 1/4 HP, 125 VAC 1/2 HP, 250 VAC 1/3 HP, 125 /250 VAC Note: 1. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance characteristics individually defined in this catalog. 2. For details on VDE, SEMKO, TUV and SEV approvals, contact the product specialist. 3. In the interest of product improvement, specifications are subject to change. OMRON ELECTRONICS, INC. OMRON CANADA, INC. One East Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON 416-286-6465 Cat. No. GC RLY6 4 9/97 Specifications subject to change without notice. Printed in the U.S.A.