TSC GBPC50-02

GBPC 40, 50 SERIES
High Current 40, 50 AMPS. Single Phase Glass Passivated Bridge Rectifiers
Voltage Range
50 to 1000 Volts
Current
40, 50.0 Amperes
GBPC40
Features
a
a
a
a
a
a
a
a
a
UL Recognized File # E-96005
The plastic material used carries
Underwriters Laboratory Flammability
Recognition 94V-0
Integrally molded heatsink provide very low
thermal resistance for maximum heat
dissipation
Universal 4-way terminals; snap-on, wraparound, solder or P.C. board mounting
Surge overload ratings 400 amperes
Terminals solderable per MIL-STD-202,
Method 208
Typical IR less than 0.2 uA
High temperature soldering guaranteed:
260°C/ 10 seconds / .375”, (9.5mm) lead
lengths
Isolated voltage from case to lead over 2500
volts
GBPC40-M
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25°C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Type Number
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
-005
-01
-02
-04
-06
-08
-10
Units
50
35
50
100
70
100
200
140
200
400
280
400
600
420
600
800
560
800
1000
700
1000
V
V
V
Maximum Average Forward
Rectified Current
@TC= 55°C
GBPC40
GBPC50
40.0
50.0
A
Peak Forward Surge Current,
Single Sine-wave Superimposed
on Rated Load (JEDEC method )
GBPC40
GBPC50
400
400
A
Maximum Instantaneous
GBPC40 @20A
Forward Voltage Drop Per
Element at Specified Current
GBPC50 @25A
Maximum DC Reverse Current
at Rated DC Blocking Voltage Per Element
Typical Thermal Resistance (Note 1) RÛJC
Operating and Storage Temperature Range TJ ,TSTG
Notes: 1. Thermal Resistance from Junction to Case.
Notes: 2. Suffix”M” - Terminal Location Face to Face.
- 530 -
1.1
V
10
uA
1.5
-50 to +150
°C/W
°C
RATINGS AND CHARACTERISTIC CURVES (GBPC40005 THRU GBPC4010)
GBPC50005
GBPC5010
FIG.1- MAXIMUM FORWARD CURRENT
DERATING CURVE
60
50
GB
PC
50
GB
30
300
200
100
40
PC
AVERAGE FORWARD CURRENT. (A)
70
40
FIG.2- MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
400
PEAK FORWARD SURGE CURRENT. (A)
80
20
1
1.5
20
2
3
4 5 6 7 8 9 10
15
20 25 30 40
NUMBER OF CYCLES AT 60Hz
10
0
20
40
60
80
100
120
140
160
180
o
CASE TEMPERATURE. ( C)
FIG.4- TYPICAL FORWARD CHARACTERISTICS
PER BRIDGE ELEMENT
FIG.3- TYPICAL REVERSE CHARACTERISTICS
PER BRIDGE ELEMENT
10
Tj=25 0C
1.0
0.1
0
20
40
60
80
100
120
C5
10
C
BP
G
40
0
Tj=25 C
PULSE WIDTH-300 S
1
.1
.6
140
BP
100
G
INSTANTANEOUS FORWARD CURRENT. (A)
INSTANTANEOUS REVERSE CURRENT. ( A)
Tj=125 0C
0
1000
100
.8
1.0
1.2
1.4
FORWARD VOLTAGE. (V)
PERCENT OF RATED PEAK REVERSE VOLTAGE. (%)
- 531-
1.6
1.8
2.0
60 80 100