Dichromatic LED Lamp GL6CU7 ø5mm(T-1 3/4), Cylinder Type(Flangeless), Colorless Transparency, High-luminosity Dichromatic LED Lamp for Outdoor Use GL6CU7 ■ Outline Dimensions ■ Radiation Diagram (Unit : mm) (Ta=25˚C) Protruded resin 1.5MAX ±0.15 Colorless transparency ø5.0 -30˚ -20˚ -10˚ +10˚ 0˚ +20˚ +30˚ 12.0±0.5 -50˚ 1.1MAX -60˚ -70˚ 17.0MIN 2.39 NOM +40˚ Red Yellow-green 80 +50˚ 60 +60˚ 40 +70˚ 20 (2.0) (2.0) 0.5 Relative luminous intensity(%) 2.39 NOM 1.0MAX -40˚ 1.0 8.6 100 -80˚ +80˚ -90˚ +90˚ 0.5 2.54 2.54 NOM NOM 1 2 3 Pin connections 1 Cathode(Yellow-green) 2 Anode(Common) 3 Cathode(Red) Unspecified tolerance:±0.2 ■ Absolute Maximum Ratings (Ta=25˚C) Model No. Radiation color Radiation material GL6CU7 Yellow-green GaP Red(Super-luminosity) GaAlAs on GaAlAs Power dissipation Forward current Peak forward current P*1 IF IFM*2 (mW) (mA) (mA) 84 75 30 30 Derating factor Reverse voltage Operating temperature Storage temperature Soldering temperature (mA/˚C) VR Topr Tstg Tsol*3 (V) (˚C) (˚C) (˚C) DC Pulse 0.40 0.40 50 50 0.67 0.67 5 4 -25 to +85 -25 to +100 260 *1 The value is specified under the condition that either color is lightened separately. When the both diodes are lightened simultaneously, the power dissipation of each diode should be less than the half of the value specified in this table. *2 Duty ratio=1/10, Pulse width=0.1ms *3 5s or less(At the position of 1.6mm or more from the bottom face of resin package) ■ Electro-optical Characteristics Forward voltage Radiation Lens VF(V) Model No. color type TYP MAX Colorless Yellow-green 2.1 2.8 GL6CU7 transparency Red(Super-luminosity) 1.85 2.5 (Notice) (Ta=25˚C) Peak emission wavelength IF λp(nm) (mA) TYP 565 660 20 20 Luminous intensity IF IV(mcd) (mA) TYP 120 250 20 20 Spectrum radiation bandwidth IF ∆λ(nm) (mA) TYP 30 20 20 20 Reverse current VR IR(µA) (V) MAX 10 100 4 3 Page for characteristics (MHZ) diagrams Terminal capacitance Ct(pF) TYP 35 30 1 1 → → ¡In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. 74 (Internet) ¡Data for sharp's optoelectronic/power device is provided for internet.(Address http://www.sharp.co.jp/ecg/) LED Lamp Characteristics Diagrams EG series Forward Current vs. Forward Voltage(Note) Forward Current Derating Curve Luminous Intensity vs. Ambient Temperature(Note) (Ta=25˚C) 100 60 (Ta=25˚C) 1000 50 500 40 30 20 Relative luminous intensity(%) Forward current IF(mA) Forward current IF(mA) 50 10 5.0 1.0 0.5 100 50 10 5.0 10 0 -25 0 25 50 75 85 100 0.1 1.0 125 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 -20 0 Forward voltage VF(V) Ambient temperature Ta(˚C) Peak Forward Current Derating Curve 40 60 80 100 120 Duty Ratio vs. Peak Forward Current Luminous Intensity vs. Forward Current(Note) 60 20 Ambient temperature Ta(˚C) (Ta=25˚C) (Ta=25˚C) 1000 500 500 200 200 40 30 20 Peak forward current IFM(mA) Relative luminous intensity(%) Peak forward current IFM(mA) 50 100 50 20 10 5.0 100 50 20 10 5.0 10 2.0 2.0 0 -25 0 25 50 75 85 100 1.0 0.1 125 1.0 0.2 0.5 Ambient temperature Ta(˚C) 1 2 5 10 20 1/50 50 1/20 1/10 1/5 1/2 1 Duty ratio DR Forward current IF(mA) Note)Characteristics shown in diagrams are typical values. (not assurance value) KG series Forward Current vs. Forward Voltage(Note) Forward Current Derating Curve Luminous Intensity vs. Ambient Temperature(Note) (Ta=25˚C) 100 60 (Ta=25˚C) 1000 50 500 40 30 20 Relative luminous intensity(%) Forward current IF(mA) Forward current IF(mA) 50 10 5.0 1.0 0.5 100 50 10 5.0 10 0 -25 0 25 50 75 85 100 0.1 1.0 125 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 -20 0 Forward voltage VF(V) Ambient temperature Ta(˚C) Peak Forward Current Derating Curve Luminous Intensity vs. Forward Current(Note) 60 20 40 60 80 100 120 Ambient temperature Ta(˚C) Duty Ratio vs. Peak Forward Current (Ta=25˚C) (Ta=25˚C) 1000 500 500 200 200 40 30 20 Peak forward current IFM(mA) Relative luminous intensity(%) Peak forward current IFM(mA) 50 100 50 20 10 5.0 100 50 20 10 5.0 10 2.0 2.0 0 -25 0 25 50 75 85 Ambient temperature Ta(˚C) 100 125 1.0 0.1 1.0 0.2 0.5 1 2 5 10 20 Forward current IF(mA) 50 1/50 1/20 1/10 1/5 1/2 1 Duty ratio DR Note)Characteristics shown in diagrams are typical values. (not assurance value) (Notice) ¡ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. 120 (Internet) ¡ devices Data for sharp's optoelectronic/power device is provided for internet.(Address http://www.sharp.co.jp/ecg/) LED Lamp Characteristics Diagrams UR series Forward Current Derating Curve Forward Current vs. Forward Voltage(Note) Luminous Intensity vs. Ambient Temperature(Note) (Ta=25˚C) 100 60 (Ta=25˚C) 1000 50 500 40 30 20 Relative luminous intensity(%) Forward current IF(mA) Forward current IF(mA) 50 10 5.0 1.0 0.5 100 50 10 5.0 10 0 -25 0 25 50 75 85 100 0.1 1.0 125 1.0 1.2 1.4 Ambient temperature Ta(˚C) 1.6 1.8 2.0 2.2 2.4 2.6 -20 0 20 Forward voltage VF(V) Luminous Intensity vs. Forward Current(Note) Peak Forward Current Derating Curve 60 80 100 120 Duty Ratio vs. Peak Forward Current (Ta=25˚C) 1000 60 40 Ambient temperature Ta(˚C) (Ta=25˚C) 500 500 200 200 40 30 20 Peak forward current IFM(mA) Relative luminous intensity(%) Peak forward current IFM(mA) 50 100 50 20 10 5.0 100 50 20 10 5.0 10 2.0 0 -25 0 25 50 75 85 100 1.0 0.1 125 2.0 1.0 0.2 0.5 1 2 5 10 20 50 1/50 1/20 1/10 Forward current IF(mA) Ambient temperature Ta(˚C) 1/5 1/2 1 Duty ratio DR Note)Characteristics shown in diagrams are typical values. (not assurance value) TR series Forward Current Derating Curve Forward Current vs. Forward Voltage(Note) 40 30 500 Relative luminous intensity(%) Forward current IF(mA) 50 20 10 5 3 20 2 10 -20 0 20 40 60 80 85 0.5 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5 100 Ambient temperature Ta(˚C) 100 50 10 -20 0 Forward voltage VF(V) 200 200 100 100 300 200 60 80 100 50 20 10 5 (Ta=25˚C) 500 Peak forward current IF(mA) 600 Relative luminous intensity(%) 500 400 40 Duty Ratio vs. Peak Forward Current (Ta=25˚C) 700 500 20 Ambient temperature Ta(˚C) Luminous Intensity vs. Forward Current(Note) Peak Forward Current Derating Curve Peak forward current IFM(mA) 200 20 1 0 (1F=20mA) 1000 50 60 Forward current IF(mA) Luminous Intensity vs. Ambient Temperature(Note) (Ta=25˚C) 100 70 50 30 10 5 100 2 0 -20 0 20 40 60 Ambient temperature Ta(˚C) 80 100 1 0.1 2 1 0.2 0.5 1 2 5 10 20 Forward current IF(mA) 50 1/50 1/20 1/10 1/5 1/2 1 Duty ratio DR Note)Characteristics shown in diagrams are typical values. (not assurance value) (Notice) ¡ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. 116 (Internet) ¡ devices Data for sharp's optoelectronic/power device is provided for internet.(Address http://www.sharp.co.jp/ecg/)