Features :
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Built-in active PFC function, PF>0.91
Protections: Short circuit / Overload / Over voltage / Over temperature
Fully enclosed plastic case
Approvals: UL / CUL / TUV / BSMI / CCC / CB / FCC / CE
Class power ( with earth pin)
LED indicator for power on
No load power consumption<0.5W
ENERGY STAR level
compliant
Meet EISA 2007(Energy Independence and Security Act)
2 years warranty
TUV
Rheinland
Product Safety
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
OUTPUT
GS220A12-R7B
GS220A15-R7B
GS220A20-R7B
GS220A24-R7B
GS220A48-R7B
GS220A12
GS220A15
15V
GS220A20
20V
GS220A24
24V
GS220A48
48V
Note.2 12V
RATED CURRENT
15A
13.4A
11A
9.2A
4.6A
CURRENT RANGE
0 ~ 15A
0 ~ 13.4A
0 ~ 11A
0 ~ 9.2A
0 ~ 4.6A
RATED POWER (max.)
180W
RIPPLE & NOISE (max.) Note.3 80mVp-p
201W
220W
221W
221W
100mVp-p
150mVp-p
180mVp-p
240mVp-p
VOLTAGE TOLERANCE Note.4
5.0%
5.0%
4.0%
3.0%
2.0%
LINE REGULATION
1.0%
1.0%
1.0%
1.0%
1.0%
5.0%
5.0%
4.0%
3.0%
2.0%
93.5%
94.5%
Note.5
LOAD REGULATION
INPUT
geprUfre
Sicherheit
SETUP, RISE TIME
Note.7 2000ms, 20ms / 230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.8 90 ~ 264VAC
20ms / 230VAC
20ms / 115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.91 / 230VAC
EFFICIENCY (Typ.)
90%
AC CURRENT
INRUSH CURRENT (max.)
4A / 115VAC
LEAKAGE CURRENT(max.)
OVERLOAD
PROTECTION OVER VOLTAGE
2000ms, 20ms / 115VAC at full load
PF>0.98 / 115VAC at full load
90%
92%
2A / 230VAC
120A / 230VAC
1.5mA / 240VAC
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
95
5 (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
WORKING HUMIDITY
-10 ~ +60 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
-20 ~ +85
, 10 ~ 95% RH
0.03% / (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943 approved
I/P-O/P: 3KVAC
SAFETY &
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION Compliance to EN55022 class B, FCC PART 15 class B / CISPR22 class B, CNS13438 class B, GB9254 class B
(Note. 6)
HARMONIC CURRENT
Compliance to EN61000-3-2,3, GB17625.1
OTHERS
CONNECTOR
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
MTBF
DIMENSION
PACKING
PLUG
191.3Khrs min. MIL-HDBK-217F(25 )
210*85*46mm (L*W*H)
1.1Kg; 12pcs/14.2Kg/0.73CUFT
See page 2 ; Other type available by customer requested
CABLE
See page 2 ; Other type available by customer requested
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
7. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. Derating may be needed under low input voltage. Please check the derating curve for more details.
File Name:GS220-SPEC 2009-11-09
GS220
220W AC-DC Single Output Desktop
Mechanical Specification
Case No.961A
46
series
Unit:mm
210
DC OUTPUT
85
INLET
UL1185 16AWGx4C 1000 50mm
30 3mm
Plug Assignment
Standard plug: R7B (option)
R7B
PIN NO OUTPUT
4
3
1
2
1,4
+V
2,3
-V
Derating Curve
Static Characteristics
100
230VAC
100
90
For others
80
80
For 12~15V
70
100VAC for others
110VAC for 12~15V
50
LOAD (%)
LOAD (%)
60
40
20
-10
10
20
30
40
50
60
AMBIENT TEMPERATURE ( )
70
(HORIZONTAL)
60
50
40
90
95
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz