GS160 160W AC-DC Industrial Adaptor series ■ Features : Universal AC input / Full range Built-in active PFC function No load power consumption<0.5W Energy efficiency Level Ⅴ Comply with EISA 2007, NRCan, AU/NZ MEPS and EU ErP 3 pole AC inlet IEC320-C14 Class I power (with earth pin) Protections: Short circuit / Overload / Over voltage / Over temperature Fully enclosed plastic case LED indicator for power on 2 years warranty (except for 48V) SPECIFICATION GS160A12-R7B GS160A15-R7B GS160A20-R7B GS160A24-R7B GS160A48-R7B DC VOLTAGE GS160A12 12V GS160A15 15V GS160A20 20V GS160A24 24V GS160A48 48V RATED CURRENT 11.5A 9.6A 8A 6.67A 3.34A CURRENT RANGE 0 ~ 11.5A 0 ~ 9.6A 0 ~ 8A 0 ~ 6.67A 0 ~ 3.34A RATED POWER (max.) 138W ORDER NO. SAFETY MODEL NO. OUTPUT 144W 160W 160W 160W RIPPLE & NOISE (max.) Note.2 80mVp-p 100mVp-p 150mVp-p 180mVp-p 240mVp-p VOLTAGE TOLERANCE Note.3 ±5.0% ±5.0% ±4.0% ±3.0% ±3.0% LINE REGULATION Note.4 ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±5.0% ±5.0% ±4.0% ±3.0% ±3.0% 92.5% 94% LOAD REGULATION INPUT SETUP, RISE TIME Note.5 2000ms, 20ms / 230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE Note.6 85 ~ 264VAC 20ms / 230VAC 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95 / 230VAC EFFICIENCY (Typ.) 89% AC CURRENT INRUSH CURRENT (max.) 1.85A / 115VAC 90% 92% 1A / 230VAC 120A / 230VAC 0.75mA / 240VAC OVERLOAD 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE 90 ℃ ± 10 ℃ (RTH2) detect on inside ambient temperature Protection type : Shut down o/p voltage, re-power on to recover WORKING TEMP. WORKING HUMIDITY -30 ~ +70℃ (Refer to "Derating Curve") 20% ~ 90% RH non-condensing SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note. 7) EMC EMISSION NOTE PF>0.98 / 115VAC at full load LEAKAGE CURRENT(max.) ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION CONNECTOR 20ms / 115VAC at full load 120 ~ 370VDC FREQUENCY RANGE PROTECTION OVER VOLTAGE OTHERS 2500ms, 20ms / 115VAC at full load -20 ~ +85℃ , 10 ~ 95% RH ±0.03% / ℃ (0~50℃ ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1(except for 48V) approved I/P-O/P: 3KVAC I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A MTBF DIMENSION 290.3K hrs min. MIL-HDBK-217F(25℃) PACKING PLUG 175*72*35mm (L*W*H) 0.66Kg; 20pcs/ 14.2Kg/ 0.85CUFT See page 2 ; Other type available by customer requested CABLE See page 2 ; Other type available by customer requested 1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3. Tolerance: includes set up tolerance, line regulation, load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 6. Derating may be needed under low input voltage. Please check the derating curve for more details. 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:GS160-SPEC 2015-06-01 GS160 160W AC-DC Industrial Adaptor Mechanical Specification Case No.GS160A 35 series Unit:mm 175 UL2464 18AWGx4C 1200 ± 50mm POWER LED 30±3mm 72 23 14 Plug Assignment Standard plug : power DIN 4 pin with lock type, KYCON KPPX-4P equivalent R7B PIN NO. OUTPUT 2 1 3 4 1,4 +V 2,3 -V AC FG -V connected to AC FG Derating Curve Static Characteristics 100 230VAC 100 85 80 60 LOAD (%) LOAD (%) 80 100VAC 50 40 70 60 50 20 -30 40 10 20 30 40 50 60 AMBIENT TEMPERATURE (℃) 70 (HORIZONTAL) 85 95 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:GS160-SPEC 2015-06-01