ETC GT-100-5

Combo Insides.qxd
11/5/2004
14:33
Page 86
GT-100 SERIES-100W
ISO 9001:2000
REGISTERED
100 Watts, Switchmode Power Supply,
Single Output, Enclosed, Universal Input
ELECTRICAL SPECIFICATIONS:
INPUT VOLTAGE:
85 VAC TO 264 VAC SELECTED BY SWITCH
INPUT CURRENT:
< 1.6 A RMS AT 90 VAC INPUT
INPUT FREQUENCY:
47 HZ - 63 HZ
OUTPUT CURRENT:
NO LOAD TO FULL LOAD, NO MINIMUM LOAD REQUIRED
OUTPUT POWER (RATED):
100 WATTS MAX
OUTPUT RIPPLE (PEAK TO PEAK):
100 mV (P-P) MODEL DEPENDENT
OUTPUT REGULATION (LINE/LOAD):
0.2% - 0.5% MODEL + OUTPUT DEPENDENT
LINE REGULATION:
TURN ON/ TURN OFF OVERSHOOT:
4% MAX 500uS MAX RECOVERY TIME FOR 25% STEP LOAD
TURN-ON DELAY:
1 SEC MAX
HOLD-UP TIME:
10 mSEC MIN AT NOMINAL INPUT 115 VAC AND FULL LOAD
INRUSH CURRENT:
30 A MAX AT COLD START FOR N.A. (60A FOR EURO),
MODEL DEPENDENT
EFFICIENCY:
70% - 84 % TYPICAL, MODEL + OUTPUT DEPENDENT
SWITCHING FREQUENCY:
100 KHZ TYPICAL
OVER-VOLTAGE PROTECTION:
VOLTAGE LIMITED LESS 130% OF NOMINAL VOLTAGE
FOR MAIN OUTPUT
OVER-CURRENT / SHORT CIRCUIT:
HICCUP WITH AUTO RECOVERY TO 1.1 - 1.3 IO
OTHER PROTECTION:
INPUT FUSING
SAFETY APPROVALS:
UL 1012, UL 60950 / 1950, CUL TO 22.2 # 234, 950, TUV TO
EN 60950, CE CLASS I
DIELECTRIC WITHSTAND VOLTAGE:
1500VAC PRIMARY-SECONDARY; 1500 VAC PRIMARYGROUND 500 VAC SECONDARY - GROUND
LEAKAGE CURRENT:
< 1 mA/240VAC
LINE SURGE:
EN 61000-4-5 LEVEL 4
EMI:
COMPLIES WITH EN55022, 1 CLASS B AND FCC PART 15
CLASS B WHEN TESTED WITH A RESISTIVE LOAD, BOTH
CONDUCTED AND RADIATED
CE MARK:
TESTED TO COMPLY WITH EN61000-3-2, EN61000-3-3 AND
EN50082-1 INCLUDING EN61000-4-2, EN61000-4-3, EN610004-4, EN61000-4-5, EN61000-4-6, EN61000-4-11 LEVEL 4, UNIT
IS ELIGIBLE FOR CE MARK.
MTBF:
GREATER THAN 50,000 HOURS AT 25°C AMBIENT
TEMPERATURE
OPERATING TEMPERATURE:
0°C TO 45° C, DERATE LINEARY TO 60% OUTPUT POWER
AT 60°C
STORAGE TEMPERATURE:
-40°C TO 80° C
HUMIDITY:
0% TO 90% RELATIVE HUMIDITY
OUTPUT VOLTAGE / CURRENT:
MODEL
NUMBER
OUTPUT
VOLTAGE
(VDC)
OUTPUT
CURRENT
(mA)
RATED
OUTPUT
POWER (W)
GT-100-3
+ 3 +/-2%
20
0 - 100 W
GT-100-5
+ 5 +/-2%
20
0 - 100 W
GT-100-7.5
+ 7.5 +/-1%
13.6
0 - 100 W
GT-100-10
+ 10 +/-1%
10
0 - 100 W
GT-100-12
+ 12 +/-1%
8.5
0 - 100 W
GT-100-15
+ 15 +/-1%
6.7
0 - 100 W
GT-100-18
+ 18 +/-1%
5.6
0 - 100 W
GT-100-24
+ 24 +/-1%
4.5
0 - 100 W
GT-100-27
+ 27 +/-1%
3.7
0 - 100 W
GT-100-48
+ 48 +/-1%
2
0 - 100 W
SPECIFICATIONS MAY CHANGE WITHOUT PRIOR NOTICE. CONSULT GLOBTEK CUSTOMER SERVICE FOR LATEST SPECIFICATIONS.
86
www.globtek.com
+1.201.784.1000
Combo Insides.qxd
11/5/2004
14:35
Page 87
GT-100 SERIES-100W
100 Watts, Switchmode Power Supply,
Single Output, Enclosed, Universal Input
ISO 9001:2000
REGISTERED
ENCLOSURES
SIZE:
199 X 98 X 38 + 1 MM
CONFIGURATION: ENCLOSED SWITCHING
POWER SUPPLY, AL. ALLOY 3003 OR
EQUIVALENT, GOLD IRRIDITE, CHEM.
TREATED FINISH,, CHASSIS: ā€œUā€™ CHANNEL,
WITH (7) MOUNTING METRIC INSERT M3,
AS SHOWN BELOW: (4) BOTTOM; (3)
RIGHT SIDE. COVER: ā€œLā€ SHAPE WITH
HOLES SCREENED PATTERN FOR
NATURAL CONVECTION COOLING
THERMAL TRANSFER.
CHARTS
OUTPUT DERATING
STATIC CHARACTERISTICS
5V
6.5V / 7.5V
SPECIFICATIONS MAY CHANGE WITHOUT PRIOR NOTICE. CONSULT GLOBTEK CUSTOMER SERVICE FOR LATEST SPECIFICATIONS.
+1.201.784.1000
www.globtek.com
87