MPA301D Series Smallest 1U Height Only 300W, Active PFC 6 x 4 x 1.5 Inches!! Dual Output AC/DC Power Supplies Key Features: • Smallest 1U 300W Supply • Dual Outputs • PFC to EN61000-3-2 “D” • Universal AC Input • UL, cUL, TUV Approvals • CE Certified • FCC Class B Emissions • 700W Peak Power • Four Mechanical Options Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Voltage Range Input Frequency Input Current, Full Load Inrush Current, Cold Start Leakage Current Power Factor Correction Input Protection Conditions Universal Min. 90 47 Typ. 100 - 120 VAC 6 200 - 240 VAC 4 110 VAC 220 VAC 240 VAC 3.5 Meets EN61000-3-2 Class D T8A/250V Fuse Max. 264 63 Units VAC Hz A 35 70 A mA Output Parameter Output Voltage Adjustment Output Regulation (Note 1) Hold Time Ripple & Noise (20 MHz) (Note 2) Overload Protection Over Voltage Protection Over Temperature Protection Temperature Coefficient Transient Recovery Time (Note 3) Transient Response Deviation Overshoot/Undershoot Turn On Delay Output Short Circuit Conditions V1 By Trim Pot Min. Typ. Max. ±5.0 ±5.0 110 VAC, 80% Load 20 See Model Selection Guide Power Limit 110 140 >130% of Rated Output Voltage. Recycle AC Input. +85 ±0.04 2.5 50% Load Change 5 At Turn On/Off 5.0 120 VAC 1 Continuous With Autorecovery Units % % mSec % ºC %/ºC mS % % S General Parameter Isolation Voltage (Note 4) Switching Frequency MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Conditions Input - Output Input - FG (Frame Ground) Primary - Core Fixed Min. 3,000 1,500 1,500 Typ. Max. Units VAC 23 kHz Interface Signals Power Supply On Power Good Signal Fan Fail Green LED (LED1) on the PCB PG on CN1. Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS before the loss of regulation. Will sink 100 mA. FF on pin 3 of CN1. Open collector output rated for 15 VDC/5 mA sink current maximum. Goes high if a fan failure is detected Environmental Parameter Operating Temperature Range Output Derating Storage Temperature Range Cooling Operating Humidity Conditions Min. Typ. Max. Ambient 0 +25 +50 2.5%/ ºC from +50 ºC to + 70 ºC -20 +85 See Model Selection Guide RH, Non-condensing 90 Units ºC ºC % Reliability Specifications Parameter MTBF Safety Standards EEMI Compliance EMS Immunity Compliance Conditions Min. Typ. Max. Units MIL HDBK 217F, 30ºC, Gnd Benign 100 kHours UL 60950; CSA C22.2 No. 60950; TUV EN60950; CB Report (IEC 60950) Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3 EN6100-4-2,3,4,5,6,8,11; EN55024,; CE Marked (LVD) Model Selection Guide Model Number MPA301Dx-0512z MPA301Dx-0524z MPA301Dx-0548z MPA301Dx-1224z Output Voltage Factory V1 V2 V1 V2 V1 V2 V1 V2 Max. Output Current (Note 6) Convection 18 CFM (U/w Air, E, F) +5 VDC +12 VDC +5 VDC +24 VDC +5 VDC +48 VDC +12 VDC +24 VDC 30.00A 16.67A 30.00A 8.33A 30.00A 4.16A 16.67A 8.33A Notes: 1. Output regulation includes line & load. 2. Ripple & noise is measured from 10 Hz to 20 MHz. Measurement connection to the unit is made with a 0.1 µF ceramic capacitor & a 22 µF electrolytic capacitor connected in parallel. 3. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%. 4. Isolation specifications are production HI-Pot tested for 3 seconds. 5. The full output range (see table above) is covered in the safety agency certification. Standard models are factory set to the “Preset” voltage. This may be set (U) 15.00A 10.42A 15.00A 5.20A 15.00A 2.60A 12.50A 6.25A Ripple & Noise 1% p-p 1% p-p 1% p-p 1% p-p 1% p-p 1% p-p 1% p-p 1% p-p Input & Output Connector CN2: Howder Terminal Block No. HB-95-7P or Mating Molex Part No. 09-91-1600 (16 pin) Efficiency Output Pin Assignment: 75% 75% Howder Molex Pins 1: V1 Pins 1 ~ 3: V1 Pins 2 ~ 3: RTN Pins 4 ~ 8: RTN Pin 4: V2 Pins 9 ~ 10: V2 75% 75% to other levels within the range without affecting the agency certification. For more information, contact the factory. 6. The maximum continuous output power level, (combined for V1 & V2) is 300W (with 28.5 CFM) for the MPA301Dx-1224 & 250W for all other models. For convection cooling, the maximum continuous output power level (combined for V1 & V2) is 150W for the MPA301Dx-1224 & 125W for all other models. For more information, contact the factory. 7. A 10% minimum load is required to maintain regulation and ripple specifications. Pin 5: GND Pin 12: GND Pin 6: Neutral Pin 14: Neutral Pin 7: Line Pin 16: Line Logic Signal Connector CN1: Mating JST XHP-3 or equivalent (CHYAO SHIUNN JS-21001-3) Mating Pins: JST SXH-002T-P0.6 for AWG 30 to 26. Fan driver connector (FAN2): 12 VDC / 400 mA is available to drive an external fan. Mating connector is a JST XHP-2 or Molex P/N 48-151-0210 ( 2 pins 0.98 pitch). Mating Pins: JST SXH-001T-P0.62T or Molex 48150 . Mechanical Dimensions: U-Chassis (U Suffix) U-Chassis Cover (C Suffix) Enclosure With End Fan (E Suffix) Enclosure With Top Fan (F Suffix) MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]