New Product News Solid-state Timers H3DK DIN Track-mounted, 22.5-mm-width Standard Timer Series LR • A wide AC/DC power supply range (24 to 240 VAC/DC).*1 • All sub-series include models with 12-VDC power supply.*1 • G-type Models (H3DK-G) now include model with 240 to 440VAC power supply. • UL*2, CSA*3, and CCC certification and EN 61812-1 compliance. CE Marking. • EMC (EN 61812-1) compliance for application in heavy industrial, residential, commercial, or light industrial environments. • Finger-safe terminal block and captive screws according to EN 50274. *1. Except for the H3DK-H. *2. Except for the H3DK-GE. *3. Scheduled to obtain certification in April 2012. Model Number Structure ■ The Entire H3DK Series H3DK Series H3DK-M/-S Multi-range, Multi-mode Timers H3DK-F Twin Timers Page 2 ■ Eight-mode Timer H3DK-M1/M2 ● Operating Modes A: ON Delay B: Flicker OFF Start B2: Flicker ON Start C: Signal ON/OFF Delay D: Signal OFF Delay E: Interval G: Signal ON/OFF Delay J: One-shot Output ■ Four-mode Timer H3DK-S1/S2 ● Operating Modes A: ON Delay B2: Flicker ON Start E: Interval J: One-shot Output H3DK-G Star-delta Timers Page 11 ● Operating Modes Flicker-OFF Start/ Flicker-ON Start H3DK-H Power OFF-delay Timers Page 15 ● Operating Modes Star-delta Timer Page 21 ● Operating Modes Power OFF-delay Timer ■ Model Number Legend (Not all models that can be represented with the model number legend can necessarily be produced.) H3DK-@@@@ 1 2 3 4 1. Type Symbol M S F G H 2. Control Output Meaning Eight-mode Timer Four-mode Timer Twin Timer Star-delta Timer Power OFF-delay Timer Symbol 1 2 Meaning SPDT DPDT * M- and S-type models only. 3. Supply Voltage Symbol Blank A B C *1 D *1 E *1 Meaning 24 to 240 VAC/DC 12 VDC 24 to 48 VAC/DC 100 to 120 VAC 200 to 240 VAC 240 to 440 VAC *2 4. Time Ranges (H-type Models Only) Symbol S L Meaning 0.1 to 1.2 s or 1 to 12 s 1 to 12 s or 10 to 120 s *1 H-type models only. *2 G-type models only. 1 New Product News Multi-range, Multi-mode Timer H3DK-M/H3DK-S LR • Multiple time ranges and operating modes let you cover a wide range of applications. • The time-limit DPDT output contacts can be changed to time-limit SPDT and instantaneous SPDT output contacts using a switch. • Sequence checks are easily performed by setting an instantaneous output to 0. • Start signal control for the H3DK-M. Ordering Information ■ List of Models Supply voltage Control output 24 to 240 VAC/DC 12 VDC Eight-mode Timer Four-mode Timer Contact output, DPDT (time-limit DPDT, or time-limit SPDT + instantaneous SPDT) Changed using a switch. Model H3DK-M2 H3DK-S2 Contact output, SPDT (time-limit SPDT) Model H3DK-M1 H3DK-S1 Contact output, DPDT (time-limit DPDT, or time-limit SPDT + instantaneous SPDT) Changed using a switch. Model H3DK-M2A H3DK-S2A Contact output, SPDT (time-limit SPDT) Model H3DK-M1A H3DK-S1A ■ Accessories (Order Separately) Item Specification Model 50 cm (l) x 7.3 mm (t) Mounting Track PFP-50N 1 m (l) x 7.3 mm (t) PFP-100N 1 m (l) x 16 mm (t) PFP-100N2 End Plate --- PFP-M Spacer --- PFP-S ■ Model Structure Model H3DK-M2 H3DK-M1 H3DK-S2 H3DK-S1 2 Operating modes A: ON Delay B: Flicker OFF start B2: Flicker ON start C: Signal ON/OFF Delay D: Signal OFF Delay E: Interval G: Signal ON/OFF Delay J: One-shot Output A: ON Delay B2: Flicker ON start E: Interval J: One-shot Output Terminal block Input type Output type Mounting method Safety standards Accessories Relay, DPDT Voltage input 9 terminals Relay, SPDT Relay, DPDT --6 terminals Relay, SPDT cURus (UL 508 CSA C22.2 No. 14) DIN Track mounting EN 61812-1 IEC 60664-1 4 kV/2 EN 50274 User label H3DK-M/H3DK-S Specifications ■ Time Ranges Time range setting Set time range 0.1 s 1s 10 s 1 min 10 min 1h 10 h 100 h 0.1 to 1.2 s 1 to 12 s 10 to 120 s 1 to 12 min 10 to 120 min 1 to 12 h 10 to 120 h 100 to 1,200 h Scale numbers 12 ■ Ratings Power supply voltage *1 • 24 to 240 VAC/DC, 50/60 Hz *2 • 12 VDC *2 Allowable voltage fluctuation range • 24 to 240 VAC/DC: 85% to 110% of rated voltage • 12 VDC: 90% to 110% of rated voltage Power reset Minimum power-OFF time: 0.1 s Reset voltage 10% of rated voltage • 24 to 240 VAC/DC High level: 20.4 to 264 VAC/DC, Low level: 0 to 2.4 VAC/DC • 12 VDC High level: 10.8 to 13.2 VDC, Low level: 0 to 1.2 VDC Voltage input Power consumption H3DK-M2/-S2 *3 H3DK-M1/-S1 H3DK-M2A/-S2A H3DK-M1A/-S1A At 240 VAC: 6.6 VA max. *4 At 240 VAC: 4.5 VA max. *4 *1. *2. *3. *4. *5. At 12 VDC: 0.9 W max. At 12 VDC: 0.6 W max. Control output Contact output, 5 A at 250 VAC with resistive load (cosφ = 1), 5 A at 30 VDC with resistive load *4, *5 Ambient operating temperature −20 to 55°C (with no icing) Storage temperature −40 to 70°C (with no icing) Ambient operating humidity 25% to 85% *6. When using a 24-VDC power supply voltage, there will be an inrush current of approximately 0.25 A. Allow for this inrush current when turning ON and OFF the power supply to the Timer with device with a solidstate output, such as a sensor. DC ripple: 20% max. The power consumption is for mode A after the Timer times out. For the H3DK-M@, the maximum power consumption is given, including the current consumed by the input circuit. Refer to DC Power Consumptions (Reference Information) on page 27 for DC power consumptions. The control output ratings are for one H3DK operating alone. If you operate two or more Timers side by side, refer to Installation Pitch and Output Switching Capacity (Reference Values) on the next page. 125 VDC: 0.15 A max. with resistive load, 125 VDC: 0.1 A with L/R of 7 ms. Minimum load: 10 mA at 5 VDC (P level, reference value) 3 H3DK-M/H3DK-S ■ Characteristics ● Installation Pitch and Output Switching Capacity (Reference Values) Setting error ±10% of FS ±0.05 s max.* Minimum input signal width 50 ms* (start input) Influence of voltage ±0.5% of FS max. (±0.5% ±10 ms max. at 1.2-s range) Influence of temperature ±2% of FS max. (±2% ±10 ms max. at 1.2-s range) Insulation resistance 100 MΩ min. at 500 VDC Dielectric strength Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC 50/60 Hz for 1 min. Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for 1 min. Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min. Impulse withstand voltage 24 to 240 VAC/VDC: 3 kV between power terminals, 4.5 kV between currentcarrying metal parts and exposed non-current-carrying metal parts 12 VDC: 1 kV between power terminals, 1.5 kV between current-carrying metal parts and exposed non-current-carrying metal parts Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise): ±1.5 kV Static immunity Malfunction: 4 kV, Destruction: 8 kV Destruction 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions Vibration resistance Malfunction 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions Shock resistance Destruction 1,000 m/s2 3 times each in 6 directions Life expectancy Mechanical 10 million operations min. (under no load at 1,800 operations/h) Malfunction 100 m/s2 3 times each in 6 directions Electrical 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) Degree of protection IP30 (Terminal block: IP20) Weight Approx. 120 g ■ Applicable standards EMC cURus: UL 508/CSA C22.2 No. 14 EN 50274: Finger protection, back-of-hand proof EN 61812-1: Pollution degree 2, Overvoltage category III CCC: Pollution degree 2, Overvoltage category II, section DB14048.5-2008 part 5-1 LR: Test Specification No. 1-2002 Category ENV 1.2 (EMI) Radiated Emissions: Emission AC Mains: Harmonic Current: Voltage Fluctuations and Flicker: (EMS) ESD Immunity: EN61812-1 EN 55011 class B EN 55011 class B EN 61000-3-2 EN61000-3-3 EN61812-1 EN 61000-4-2: 6 kV contact discharge, 8 kV air discharge Radiated Radio-Frequency Electromagnetic Field Immunity (AM Radio Waves): EN 61000-4-3: 10 V/m (80 MHz to 1 GHz) Burst Immunity: EN 61000-4-4: 2 kV power line, 1 kV I/O signal line Surge Immunity: EN 61000-4-5: 2 kV common mode, 1 kV differential mode ■ I/O Item Model Input Start Output Control output H3DK-M1/-M2 Functions to start timing. H3DK-S1/-S2 There is no start input. The output is turned ON/OFF according to the operating mode when the value that is set on the dial is reached. * * If the INST/TIME switch on the front of the Timer is set to INST on the H3DK-M2/-S2, relay R2 will operate as instantaneous contacts and will turn ON/OFF in synchronization with the power supply. 4 80 70 60 d = 50 mm d = 10 mm 50 d = 5 mm 40 30 d=0 A 20 10 0 1 2 3 4 5 6 Load current (A) Testing Method Tested Timer: H3DK-M/-S Applied voltage: 240 VAC Installation pitch: 0, 5, 10, and 50 mm * With the H3DK-M@, if the voltage exceeds 26.4 VAC/DC in mode C, D, or G, the OFF trigger signal characteristics are as follows: Accuracy of operating time: ±1% ±50 ms max. +100 ms Setting error: ±10% −50 ms max. Minimum input signal width: 100 ms Safety standards The relation between the installation pitch and the load current is shown in the following graph. (Except for the H3DK-GE) If Timer is used under load conditions that exceed the specified values, the temperature inside the Timer will increase, reducing the life expectancy of internal parts. Ambient temperature (°C) ±1% of FS max. (±1% ±10 ms max. at 1.2-s range)* Maximum ambient operating temperature in specifications Accuracy of operating time Test timer 1 DIN Track Test timer 2 Test timer 3 Test timer 4 Timer installation pitch: d Test timer 5 H3DK-M/H3DK-S Connections ■Block Diagrams H3DK-M1/-M2 Time setting detection circuit AC (DC) input ROM Time specification switches RAM Operating mode switch Clock Power supply circuit Output circuit One-chip microcomputer Input circuit Start input Indicator circuit Power indicator Output indicator H3DK-S1/-S2 AC (DC) input Time specification switches Time setting detection circuit ROM RAM Power supply circuit Operating mode switch Clock Output circuit One-chip microcomputer Indicator circuit Power indicator Output indicator 5 H3DK-M/H3DK-S ■ Terminal Arrangement H3DK-M1 A1 H3DK-M2 15 A1 15 H3DK-S1 25/21 A1 H3DK-S2 15 A1 15 25/21 * * R1 R1 R2 R1 R1 R2 15 15 25/21 15 15 25/21 18 16 18 B1 18 16 16 28/24 26/22 28/24 26/22 Start 18 A2 16 B1 18 16 18 28/24 26/22 Start 18 A2 See note 3. 16 18 A2 See note 3. A1 B1 (DIN notation) 15 A1 B1 15 A1 A2 A2 A2 16 18 A2 See note 3. (DIN notation) (21) 25 16 See note 3. Note 1: The time-limit contact symbol for previous models of Timers was . The time-limit contact symbol for the H3DK is used because the H3DK supports multiple operating modes. Note 2: *The relay R2 can be set to either instantaneous or time-limit contacts using the switch on the front of the Timer. Note 3: The power supply terminals do not have polarity. (DIN notation) 16 28/24 26/22 . A different symbol is (DIN notation) 15 A1 A2 16 18 16 18 26 28 (22) (24) 15 (21) 25 16 18 26 28 (22) (24) ■ Input Connections The start input of the H3DK-M1/-M2 is a voltage input. PNP Transistor Input NPN Transistor Input Relay Input Voltage Input Signal Levels Sensor 24 VDC Sensor (sensor power supply) (+) 24 VDC (−) 24 VDC (sensor power supply) Timer A1 (+) B1 Start A2 (−) Operates when PNP transistor turns ON. 24 VDC Timer Timer A1 (−) A1 B1 Start B1 Start A2 (+) A2 (−) (+) Operates when NPN transistor turns ON. Transistor input Operates when relay turns ON. Consider the minimum load of the relay. (See signal levels on the right.) Relay input 6 1. Transistor ON • Residual voltage: 1 V max. Voltage between terminals B1 and A2 must be equal to or higher than the rated high level voltage (20.4 VDC min.). 2. Transistor OFF • Leakage current: 0.01 mA max. Voltage between terminals B1 and A2 must be equal to or below the rated low level voltage (2.4 VDC min.). Use relays that can adequately switch 0.1 mA at the imposed voltage. When the relay is ON or OFF, the voltage between terminals B1 and A2 must be within the following ranges: • 24 to 240 VAC/DC When relay is ON: 20.4 to 264 VAC/DC When relay is OFF: 0 to 2.4 V • 12 VDC When relay is ON: 10.8 to 13.2 V When relay is OFF: 0 to 1.2 V H3DK-M/H3DK-S Nomenclature H3DK-M2 H3DK-S2 Front View Bottom View User label attachment location Terminal Block (See notes 1 and 2.) Time range switch Output indicator (orange) (Lit while Timer gives output.) Main dial (for setting the time) Note 1. Use solid wire (2.5 mm2 max.) or ferrules with insulative sleeves to connect to the terminals. To maintain the withstand voltage after connecting the terminals, insert no more than 8 mm of exposed conductor into the terminal. Using Solid Wire (2.5 mm2 Max.) Operation/power indicator (green) (Lit while the power is ON.) Using Ferrule with Insulative Sleeve 8 mm max. Operating mode switch 8 mm max. Recommended Ferrules Phoenix Contact • AI@@@ Series • AI-TWIN@@@ Series Note 2. Screw Tightening Torque Recommended torque: 0.49 N·m Maximum torque: 0.98 N·m INIT/TIME switch for relay R2 (Default setting is for time-limit output.)* *If the switch is left between settings, proper operation may not be possible. Make sure that the switch is set properly. Note: The default settings are for 0.1 s in mode A. H3DK-M1 H3DK-S1 Front View User label attachment location User label attachment location Time range switch* Time range switch Output indicator (orange) (Lit while Timer gives output.) Front View Main dial (for setting the time) Output indicator (orange) (Lit while Timer gives output.) Operation/power indicator (green) (Lit while the power is ON.) Operation/power indicator (green) (Lit while the power is ON.) Operating mode switch Operating mode switch* *If the switch is left between settings, proper operation may not be possible. Make sure that the switch is set properly. Note: The default settings are for 0.1 s in mode A. Main dial (for setting the time) *If the switch is left between settings, proper operation may not be possible. Make sure that the switch is set properly. Note: The default settings are for 0.1 s in mode A. 7 H3DK-M/H3DK-S Dimensions (Unit: mm) ■ Timers H3DK-M H3DK-S 100 88.2 22.5 22.5 22.5 69.1 4 79 65.6 52 H3DK-M2 H3DK-S2 89.4 H3DK-M1 H3DK-S1 H3DK-M2 H3DK-S2 H3DK-M1 H3DK-S1 ■ Track Mounting Products (Sold Separately) Refer to page 28 for details. Operating Procedures ■ Basic Operation ● Setting Switches • Each switch has a snap mechanism that secures the switch at given positions. Set the switch to one of these positions. Do not set it midway between two positions. Malfunction could result from an improper setting. Setting the Operating Mode ● Setting the Operating Mode The H3DK-M can be set to any of eight operating modes. The H3DK-S can be set to any of four operating modes. Turn the operating mode switch with a flatblade or Phillips screwdriver. The H3DKM can be set to any of eight modes; the H3DK-S, to any of four modes. Setting the INIT/TIME Switch ● Switching Relay R2 between Instantaneous and Time-limit Contacts (H3DK-M2/-S2 Only) The INIT/TIME switch can be used to switch relay R2 between instantaneous and time-limit operation. Setting the Time Range ● Setting the Time Range The time range switch can be used to set the time range. Turn the switch with a flat-blade or Phillips screwdriver. Time range switch Operating mode switch 8 INIT/TIME switch H3DK-M/H3DK-S ■ Timing Charts • There is no start input with the H3DK-S. Timer operation starts when the power is turned ON. • There is no instantaneous output with the H3DK-@1. A: ON Delay t−a t Basic Operation t Power (A1 and A2) Start (B1 and A1) Power Time-limit contacts: NC 15 and 16 (25 and 26) Time-limit contacts: NO (output indicator) 15 and 18 (25 and 28) * Start input ** Timing Output Instantaneous contacts: NC (21 and 22) * For power ON-delay operation, connect start input terminals B1 and A1. The Timer starts operating as soon as the power turns ON. ** The start input is ignored while the Timer is in operation. Instantaneous contacts: NO (21 and 24) Power indicator B: Flicker OFF Start t t−a t t t t t−a Basic Operation Power (A1 and A2) Start (B1 and A1) Power Time-limit contacts: NC 15 and 16 (25 and 26) Time-limit contacts: NO (output indicator) 15 and 18 (25 and 28) * Start input ** Timing Timing Timing Timing Output Instantaneous contacts: NC (21 and 22) * To start with the power supply, connect start input terminals B1 and A1. The Timer starts operating as soon as the power turns ON. ** The start input is ignored while the Timer is in operation. Instantaneous contacts: NO (21 and 24) Power indicator B2: Flicker ON start t t−a t t t t Basic Operation t−a Power (A1 and A2) Start (B1 and A1) Power Time-limit contacts: NC 15 and 16 (25 and 26) Time-limit contacts: NO (output indicator) 15 and 18 (25 and 28) * Start input ** Timing Timing Timing Timing Output Instantaneous contacts: NC (21 and 22) * To start with the power supply, connect start input terminals B1 and A1. The Timer starts operating as soon as the power turns ON. ** The start input is ignored while the Timer is in operation. Instantaneous contacts: NO (21 and 24) Power indicator C: Signal ON/ OFF Delay t t t t−a t t−a Basic Operation Power (A1 and A2) Start (B1 and A1) Time-limit contacts: NC 15 and 16 (25 and 26) Time-limit contacts: NO (output indicator) 15 and 18 (25 and 28) Instantaneous contacts: NC (21 and 22) Power * Start input Timing Timing Timing Output Timing * The start input is valid while the Timer is in operation. Instantaneous contacts: NO (21 and 24) Power indicator Note 1.The reset time is 0.1 s min. Make sure the signal input time is 0.05 s or longer. Note 2.“t” is the set time. “t−a” is a time that is less that the set time. 9 H3DK-M/H3DK-S D: Signal OFF delay t−a t t−a t−a t Basic Operation Power (A1 and A2) Start (B1 and A1) Power Time-limit contacts: NC 15 and 16 (25 and 26) Time-limit contacts: NO (output indicator) 15 and 18 (25 and 28) * Start input Timing Output Instantaneous contacts: NC (21 and 22) * The start input is valid while the Timer is in operation. Instantaneous contacts: NO (21 and 24) Power indicator E: Interval t t t−a t−a Basic Operation t Power (A1 and A2) Start (B1 and A1) Power Time-limit contacts: NC 15 and 16 (25 and 26) Time-limit contacts: NO (output indicator) 15 and 18 (25 and 28) * Start input ** Timing Output Instantaneous contacts: NC (21 and 22) * For power ON-delay operation, connect start input terminals B1 and A1. The Timer starts operating as soon as the power turns ON. ** The start input is valid while the Timer is in operation. Instantaneous contacts: NO (21 and 24) Power indicator G: Signal ON/ OFF Delay t t t t−a t−a t Basic Operation Power (A1 and A2) Start (B1 and A1) Power Time-limit contacts: NC 15 and 16 (25 and 26) Time-limit contacts: NO (output indicator) 15 and 18 (25 and 28) * Start input Timing Timing Timing Timing Output Instantaneous contacts: NC (21 and 22) * The start input is valid while the Timer is in operation. Instantaneous contacts: NO (21 and 24) Power indicator J: One-shot Output (ON delay) t t t−a t−a t Basic Operation Power (A1 and A2) Start (B1 and A1) Time-limit contacts: NC 15 and 16 (25 and 26) Time-limit contacts: NO (output indicator) 15 and 18 (25 and 28) Power 1 s±0.6 s (fixed) 1 s±0.6 s (fixed) 1 s±0.6 s (fixed) Instantaneous contacts: NC (21 and 22) Instantaneous contacts: NO (21 and 24) Power indicator Note 1.The reset time is 0.1 s min. Make sure the signal input time is 0.05 s or longer. Note 2.“t” is the set time. “t−a” is a time that is less that the set time. 10 * Start input ** Timing Output 1 s±0.6 s (fixed) * To start with the power supply, connect start input terminals B1 and A1. The Timer starts operating as soon as the power turns ON. ** The start input is valid while the Timer is in operation. New Product News Twin Timer H3DK-F LR • Switch between flicker-OFF or flicker-ON start mode. • Independent ON time and OFF time settings. • Eight time ranges from 0.1 s to 1,200 h. Ordering Information ■ List of Models Operating modes Flicker OFF start/flicker ON start Supply voltage Control output H3DK-F 24 to 240 VAC/DC Contact output: SPDT Model H3DK-F 12 VDC Contact output: SPDT Model H3DK-FA ■ Accessories (Order Separately) Item Specification Model 50 cm (l) x 7.3 mm (t) Mounting Track PFP-50N 1 m (l) x 7.3 mm (t) PFP-100N 1 m (l) x 16 mm (t) PFP-100N2 End Plate --- PFP-M Spacer --- PFP-S ■ Model Structure Model H3DK-F Operating modes Terminal block Flicker OFF start/flicker ON start 6 terminals Output type Mounting method Safety standards cURus (UL508 CSA C22.2 No. 14) DIN Track mounting EN 61812-1 IEC 60664-1 4 kV/2 EN 50274 Relay, SPDT Accessories User label Specifications ■ Time Ranges Time range setting Set time range 0.1 s 1s 10 s 1 min 10 min 1h 10 h 100 h 0.1 to 1.2 s 1 to 12 s 10 to 120 s 1 to 12 min 10 to 120 min 1 to 12 h 10 to 120 h 100 to 1,200 h Scale numbers 12 ■ Ratings Power supply voltage *1 • 24 to 240 VAC/DC, 50/60 Hz *2 • 12 VDC *2 Allowable voltage fluctuation range • 24 to 240 VAC/DC: 85% to 110% of rated voltage • 12 VDC: 90% to 110% of rated voltage Power reset Minimum power-OFF time: 0.1 s Reset voltage Power consumption 10% of rated voltage H3DK-F At 240 VAC: 4.5VA max. *3 H3DK-FA At 12 VDC: 0.6 W max. Control output Contact output (SPDT): 5 A at 250 VAC with resistive load (cosφ = 1) 5 A at 24 VDC with resistive load *3, *4 Ambient operating temperature −20 to 55°C (with no icing) Storage temperature −40 to 70°C (with no icing) Ambient operating humidity 25% to 85% 11 H3DK-F *1. When using a 24-VDC power supply voltage, there will be an inrush current of approximately 0.25 A. Allow for this inrush current when turning ON and OFF the power supply to the Timer with device with a solid-state output, such as a sensor. *2. DC ripple: 20% max. *3. Refer to DC Power Consumptions (Reference Information) on page 27 for DC power consumptions. *4. The control output ratings are for one H3DK operating alone. If you operate two or more Timers side by side, refer to Installation Pitch and Output Switching Capacity (Reference Values) on the next page. *5. 125 VDC: 0.15 A max. with resistive load, 125 VDC: 0.1 A with L/R of 7 ms. Minimum load: 10 mA at 5 VDC (P level, reference value) ■ Characteristics ±1% of FS max. (±1% ±10 ms max. at 1.2-s range) Setting error ±10% of FS ±0.05 s max. Influence of voltage ±0.5% of FS max. (±0.5% ±10 ms max. at 1.2-s range) Influence of temperature ±2% of FS max. (±2% ±10 ms max. at 1.2-s range) Insulation resistance 100 MΩ min. at 500 VDC Dielectric strength Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC 50/60 Hz for 1 min. Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for 1 min. Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min. Impulse withstand voltage 24 to 240 VAC/VDC: 3 kV between power terminals, 4.5 kV between currentcarrying metal parts and exposed non-current-carrying metal parts 12 VDC: 1 kV between power terminals, 1.5 kV between current-carrying metal parts and exposed non-current-carrying metal parts Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise): ±1.5 kV Static immunity Malfunction: 4 kV, Destruction: 8 kV Life expectancy Mechanical 10 million operations min. (under no load at 1,800 operations/h) Malfunction 100 m/s2 3 times each in 6 directions 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) IP30 (Terminal block: IP20) Weight Approx. 110 g EMC (EMI) Radiated Emissions: Emission AC Mains: Harmonic Current: Voltage Fluctuations and Flicker: (EMS) ESD Immunity: EN61812-1 EN 55011 class B EN 55011 class B EN 61000-3-2 EN61000-3-3 EN61812-1 EN 61000-4-2: 6 kV contact discharge, 8 kV air discharge Radiated Radio-Frequency Electromagnetic Field Immunity (AM Radio Waves): EN 61000-4-3: 10 V/m (80 MHz to 1 GHz) Burst Immunity: EN 61000-4-4: 2 kV power line, 1 kV I/O signal line Surge Immunity: EN 61000-4-5: 2 kV common mode, 1 kV differential mode ■ I/O Output 12 None Control output 60 d = 50 mm d = 10 mm 50 d = 5 mm 30 d = 0 mm 20 10 0 1 2 3 4 5 Output is turned ON/OFF according to the time set on the ON time setting dial and OFF time setting dial. 6 Load current (A) Tested Timer: H3DK-F Applied voltage: 240 VAC Installation pitch: 0, 5, 10, and 50 mm cURus: UL 508/CSA C22.2 No. 14 EN 50274: Finger protection, back-of-hand proof EN 61812-1: Pollution degree 2, Overvoltage category III CCC: Pollution degree 2, Overvoltage category II, section DB14048.5-2008 part 5-1 LR: Test Specification No. 1-2002 Category ENV 1.2 Input 70 Testing Method ■ Applicable standards Safety standards 80 Maximum ambient operating temperature in specifications Shock resistance Destruction 1,000 m/s2 3 times each in 6 directions Degree of protection The relation between the installation pitch and the load current is shown in the following graph. (Except for the H3DK-GE) If Timer is used under load conditions that exceed the specified values, the temperature inside the Timer will increase, reducing the life expectancy of internal parts. 40 Destruction 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions Vibration resistance Malfunction 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions Electrical ● Installation Pitch and Output Switching Capacity (Reference Values) Ambient temperature (°C) Accuracy of operating time Test timer 1 DIN Track Test timer 2 Test timer 3 Test timer 4 Timer installation pitch: d Test timer 5 H3DK-F Connections ■ Block Diagrams ■ Terminal Arrangement H3DK-F H3DK-F A1 ON OFF indicator indicator ON/OFF time setting detection circuit ON/OFF start switch 15 R1 15 AC (DC) input Time specification switches Indicator circuit 18 ROM RAM 16 Clock One-chip microcomputer Power supply circuit Output circuit 18 16 A2 (DIN notation) A1 A2 15 16 18 Note: The power supply terminals do not have polarity. Nomenclature H3DK-F Front View Bottom View Note 1. Use solid wire (2.5 mm2 max.) or ferrules with insulative sleeves to connect to the terminals. To maintain the withstand voltage after connecting the terminals, insert no more than 8 mm of exposed conductor into the terminal. User label attachment location ON time range switch ON output indicator (orange) ON time setting dial (Sets the ON time.) OFF output indicator (green) OFF time setting dial (Sets the OFF time.) OFF time range switch ON/OFF start switch (Default setting is for an OFF start.) Using Solid Wire (2.5 mm2 Max.) Using Ferrule with Insulative Sleeve Terminal Block (See notes 1 and 2.) 8 mm max. 8 mm max. Recommended Ferrules Phoenix Contact • AI@@@ Series • AI-TWIN@@@ Series Note 2. Screw Tightening Torque Recommended torque: 0.49 N·m Maximum torque: 0.98 N·m 13 H3DK-F Dimensions (Unit: mm) ■ Timers H3DK-F 100 88.2 22.5 69.1 4 79 65.6 52 89.4 ■ Track Mounting Products (Sold Separately) Refer to page 28 for details. Operating Procedures ■ Basic Operation Setting the Time Ranges Setting the ON/OFF Start Switch Setting the Times ● Setting the Time Ranges ● Setting an ON Start or OFF Start ● Setting the Times Use the ON time range switch to set the ON time range and the OFF time range switch to set the OFF time range. Turn the switches with a flat-blade or Phillips screwdriver. The ON/OFF start switch can be used to switch between ON-start and OFF-start operation. Use the ON time setting dial and the OFF time setting dial to set the ON time and OFF time. ON time setting dial ON time range switch ON/OFF start switch OFF time setting dial OFF time range switch ■ Timing Charts Flicker OFF start Flicker ON start 0.1 s min. 0.1 s min. Power (A1 and A2) ON OFF ON indicator (15 and 18) ON OFF tOFF tON tOFF tON Power (A1 and A2) ON OFF tOFF tOFF ON indicator (15 and 18) ON OFF tON tOFF tON tOFF tON tON OFF indicator (15 and 16) ON OFF OFF indicator (15 and 16) ON OFF Output (15 and 18) ON OFF Output (15 and 18) ON OFF tON: ON set time tOFF: OFF set time tON: ON set time tOFF: OFF set time Note 1. The reset time is 0.1 s min. Note 2. When power is supplied in flicker ON start mode, the OFF indicator lights momentarily. This, however, has no effect on the performance of the Timer. 14 New Product News Star-delta Timer H3DK-G LR • Set two time ranges between 1 and 120 s with one Timer. • Models with 240 to 440-VAC power supply added to series. Ordering Information ■ List of Models Operating modes Supply voltage Control output H3DK-G 24 to 240 VAC/DC Star-delta Timer Model H3DK-G Contact outputs Model Delta circuit: SPDT, Star circuit: SPDT Model 12 VDC 240 to 440 VAC H3DK-GA H3DK-GE ■ Accessories (Order Separately) Item Specification Model 50 cm (l) x 7.3 mm (t) Mounting Track PFP-50N 1 m (l) x 7.3 mm (t) PFP-100N 1 m (l) x 16 mm (t) PFP-100N2 End Plate --- PFP-M Spacer --- PFP-S ■ Model Structure Model Terminal block H3DK-G 9 terminals Operating/resetting method Time-limit operation/selfresetting Output type Time-limit (relay) Star circuit: SPDT Delta circuit: SPDT Mounting method Safety standards cURus*1 (UL 508 CSA C22.2 No. 14) DIN Track mounting EN 61812-1 IEC 60664-1 4 kV/2 EN 50274 Accessories User label *1. Except for the H3DK-GE. Specifications ■ Time Ranges Time range setting Star set time (t1) range Star-Delta transfer time (t2) t1x1 t1x10 1 to 12 s 10 to 120 s Select from 0.05, 0.1, 0.25, or 0.5 s. ■ Ratings H3DK-G, -GA • 24 to 240 VAC/DC, 50/60 Hz *2 • 12 VDC *2 Power supply voltage *1 Allowable voltage fluctuation range Power reset 80 % to 110% of rated voltage Minimum power-OFF time: 0.5 s Reset voltage Power consumption • 24 to 240 VAC/DC: 85% to 110% of rated voltage • 12 VDC: 90% to 110% of rated voltage H3DK-GE • 240 to 440 VAC (50/60 Hz) *6 10% of rated voltage H3DK-G At 240 VAC: 6.6 VA max. *3 H3DK-GA At 12 VDC: 0.9 W max. Control output Contact output (Time-limit output: relay, Star output: SPDT, Delta output: SPDT): 5 A at 250 VAC with resistive load (cosφ = 1) 5 A at 24 VDC with resistive load *3, *4 Ambient operating temperature −20 to 55°C (with no icing) Storage temperature −40 to 70°C (with no icing) Ambient operating humidity 25% to 85% At 440 VAC: 34 VA max. Ith 2 A AC-15 AC-15 AC-15 120 VAC: 1.5 A 240 VAC: 1 A 440 VAC: 0.3 A 15 H3DK-G *1. When using a 24-VDC power supply voltage, there will be an inrush current of approximately 0.25 A. Allow for this inrush current when turning ON and OFF the power supply to the Timer with device with a solid-state output, such as a sensor. *2. DC ripple: 20% max. *3. Refer to DC Power Consumptions (Reference Information) on page 27 for DC power consumptions. *4. The control output ratings are for one H3DK operating alone. If you operate two or more Timers side by side, refer to Installation Pitch and Output Switching Capacity (Reference Values) on the next page. *5. 125 VDC: 0.15 A max. with resistive load, 125 VDC: 0.1 A with L/R of 7 ms. Minimum load: 10 mA at 5 VDC (P level, reference value) *6. For the H3DK-GE, approx. 6 A of inrush current will flow when the power supply is turned ON. When selecting the device connected to the Timer, allow leeway in the current ratings. ■ Characteristics ±1% of FS max. Setting error ±10% of FS ±0.05 s max. Transfer time Total error ± (25% of transfer time + 5 ms) max. Influence of voltage ±0.5% of FS max. Influence of temperature ±2% of FS max. Insulation resistance 100 MΩ min. at 500 VDC Dielectric strength Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC 50/60 Hz for 1 min. Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for 1 min. Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min. Impulse withstand voltage H3DK-G: 24 to 240 VAC/VDC: 3 kV between power terminals, 4.5 kV between current-carrying metal parts and exposed non-currentcarrying metal parts H3DK-GA: 12 VDC: 1 kV between power terminals, 1.5 kV between current-carrying metal parts and exposed non-current-carrying metal parts Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,500 VAC 50/60 Hz for 1 min. Between control output terminals and operating circuit: 2,500 VAC 50/60 Hz for 1 min. Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min. --- Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise): ±1.5 kV* Static immunity Malfunction: 4 kV, Destruction: 8 kV * 16 80 70 60 Destruction 1,000 m/s2 3 times each in 6 directions d = 5 mm 30 d = 0 mm 20 10 0 Mechanical 10 million operations min. (under no load at 1,800 operations/h) Electrical 100,000 operations min. 100,000 operations min. (5 A at 250 (0.3 A at 440 VAC, resistive load at VAC, resistive load at 360 operations/h) 1,800 operations/h) Weight Approx. 120 g Except for the H3DK-GE 2 3 4 5 Tested Timer: H3DK-G Applied voltage: 240 VAC Installation pitch: 0, 5, 10, and 50 mm Test timer 2 Test timer 3 Test timer 4 10 million operations min. (under no load at 1,800 operations/h) DIN Track IP30 (Terminal block: IP20) 1 6 Load current (A) Test timer 1 Malfunction 100 m/s2 3 times each in 6 directions Degree of protection d = 50 mm d = 10 mm 50 Testing Method Destruction 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions Vibration resistance Malfunction 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions Life expectancy The relation between the installation pitch and the load current is shown in the following graph. (Except for the H3DK-GE) If Timer is used under load conditions that exceed the specified values, the temperature inside the Timer will increase, reducing the life expectancy of internal parts. 40 Noise immunity Shock resistance ● Installation Pitch and Output Switching Capacity (Reference Values) Maximum ambient operating temperature in specifications Accuracy of operating time H3DK-GE Ambient temperature (°C) H3DK-G, -GA Timer installation pitch: d Test timer 5 H3DK-G ■ Applicable standards Safety standards cURus: UL 508/CSA C22.2 No. 14 *1 EN 50274: Finger protection, back-of-hand proof EN 61812-1: Pollution degree 2, Overvoltage category III *2 CCC: Pollution degree 2, Overvoltage category II, section DB14048.5-2008 part 5-1 LR: Test Specification No. 1-2002 Category ENV 1.2 *1 (EMI) Radiated Emissions: Emission AC Mains: Harmonic Current: Voltage Fluctuations and Flicker: (EMS) ESD Immunity: EN61812-1 EN 55011 class B EN 55011 class B EN 61000-3-2 *1 EN61000-3-3 *1 EN61812-1 EN 61000-4-2: 6 kV contact discharge, 8 kV air discharge Radiated Radio-Frequency Electromagnetic Field Immunity (AM Radio Waves): EN 61000-4-3: 10 V/m (80 MHz to 1 GHz) Burst Immunity: EN 61000-4-4: 2 kV power line, 1 kV I/O signal line Surge Immunity: EN 61000-4-5: 2 kV common mode, 1 kV differential mode EMC *1. This standard is not applicable to the H3DK-GE. *2. This standard is not applicable if the output is used with a rating that exceeds 250 VAC. ■ I/O Input None Output Control output The star output is turned OFF when the dial set value is reached and the delta output is turned ON after the preset transfer time elapses. Connections ■ Block Diagrams ■ Terminal Arrangement H3DK-G H3DK-G AC (DC) input Star-delta transfer time switch Star time setting switch A1 15 25 Delta Star contacts contacts Power supply circuit Star output ROM RAM Clock R1 R2 15 25 Output circuit Delta output One-chip microcomputer Indicator circuit 18 16 28 28 26 18 16 26 A2 (DIN notation) Star output ON Delta output ON indicator indicator A1 A2 15 25 16 18 26 28 Note: The power supply terminals do not have polarity. 17 H3DK-G Nomenclature H3DK-G Front View Bottom View Note 1. Use solid wire (2.5 mm2 max.) or ferrules with insulative sleeves to connect to the terminals. To maintain the withstand voltage after connecting the terminals, insert no more than 8 mm of exposed conductor into the terminal. User label attachment location Terminal block (See notes 1 and 2.) Star operation indicator (green) Main dial (Sets the star time.) Using Solid Wire (2.5 mm2 Max.) Using Ferrule with Insulative Sleeve Delta operation indicator (orange) 8 mm max. Star-delta transfer time switch H3DK-GE Front View Bottom View User label attachment location Star operation indicator (green) Terminal block (See notes 1 and 2.) Main dial (Sets the star time.) Delta operation indicator (orange) Star-delta transfer time switch 18 8 mm max. Recommended Ferrules Phoenix Contact • AI@@@ Series • AI-TWIN@@@ Series Note 2. Screw Tightening Torque Recommended torque: 0.49 N·m Maximum torque: 0.98 N·m Note 3. Always keep the front cover mounted when using the Timer. Front cover (See note 3.) H3DK-G Dimensions (Unit: mm) ■ Timers H3DK-G 100 88.2 22.5 69.1 4 79 65.6 52 89.4 H3DK-GE 102 88.2 26 22.5 69.1 89.4 79 65.6 55 4 ■ Track Mounting Products (Sold Separately) Refer to page 28 for details. 19 H3DK-G Operating Procedures ■ Basic Operation Setting the Time Ranges Setting the Time ● Setting the Delta Time Range and the Star-delta Transfer Time (t2) ● Setting the Time The start time is set with the main dial. Star Time (t1) Range Set the star-delta transfer time. For ×1 (1 to 12 s), use side (A) (labeled “t1×1”). For ×10 (10 to 120 s), use side (B) (labeled “t10×1”). (See following diagram.) (A) Star-delta transfer time setting (t2) Switches the start time (t1) range. (B) 0.5s 0.25s 0.1s 0.05s 0.5s 0.25s 0.1s 0.05s t2 t1x1 Main dial t2 t1x10 ■ Timing Chart 0.5 s min. Power (A1 and A2) ON OFF Star contacts (15 and 18) ON OFF Delta contacts (25 and 26) ON OFF Star operation indicator ON OFF t1 t2 Delta operation indicator ON OFF t1: Star time setting t2: Transfer time Note: “t1” is the start set time. “t2” is the transfer time. 20 New Product News Power OFF-delay Timer H3DK-H • Set two time ranges with each Timer, from 0.1 to 12 seconds for the S Series and from 1.0 to 120 seconds for the L Series. Ordering Information ■ List of Models H3DK-H Operating modes Power OFF Delay Supply voltage S Series (time range: 0.1 to 12 s) Control output L Series (time range: 1.0 to 120 s) 100 to 120 VAC Contact output: SPDT Model H3DK-HCS H3DK-HCL 200 to 240 VAC Contact output: SPDT Model H3DK-HDS H3DK-HDL 24 to 48 VAC/DC Contact output: SPDT Model H3DK-HBS H3DK-HBL ■ Accessories (Order Separately) Item Specification Model 50 cm (l) x 7.3 mm (t) Mounting Track PFP-50N 1 m (l) x 7.3 mm (t) PFP-100N 1 m (l) x 16 mm (t) PFP-100N2 End Plate --- PFP-M Spacer --- PFP-S ■ Model Structure Model Terminal block H3DK-H Operating/resetting method Output type Instantaneous operation/ time-limit reset 6 terminals Relay, SPDT Mounting method Safety standards cURus (UL 508 CSA C22.2 No. 14) DIN Track mounting EN 61812-1 IEC 60664-1 4 kV/2 EN 50274 Accessories User label Specifications ■ Time Ranges S Series Time range setting Set time range L Series x0.1 x1 x1 x10 0.1 to 1.2 s 1 to 12 s 1 to 12 s 10 to 120 s Power ON time 0.1 s min. Scale numbers 0.3 s min. 12 ■ Ratings • 100 to 120 VAC, 50/60 Hz • 200 to 240 VAC, 50/60 Hz • 24 to 48 VAC/DC, 50/60 Hz Supply voltage Allowable voltage fluctuation range Power consumption *1 85% to 110% of rated voltage H3DK-HCS/-HCL At 120 VAC: 11.7 VA max. H3DK-HDS/-HDL At 240 VAC: 29.5 VA max. H3DK-HBS/-HBL At 48 VAC: 1.2 VA max. *2 Control output Contact output, 5 A at 250 VAC with resistive load (cosφ = 1), 5 A at 30 VDC with resistive load *2 Ambient operating temperature −20 to 55°C (with no icing) Storage temperature −40 to 70°C (with no icing) Ambient operating humidity 25% to 85% 21 H3DK-H *1. DC ripple: 20% max. (A single-phase, full-wave rectifying power supply can be connected.) *2. Refer to DC Power Consumptions (Reference Information) on page 27 for DC power consumptions. *3. The control output ratings are for one H3DK operating alone. If you operate two or more Timers side by side, refer to Installation Pitch and Output Switching Capacity (Reference Values) on the next page. ■ Characteristics Setting error ±10% of FS ±0.05 s max. Influence of voltage ±0.5% of FS max. (±0.5% ±10 ms max. at 1.2-s range) Influence of temperature ±2% of FS max. (±2% ±10 ms max. at 1.2-s range) Insulation resistance 100 MΩ min. at 500 VDC Dielectric strength Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC 50/60 Hz for 1 min. Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for 1 min. Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min. Impulse withstand voltage Between power supply terminals: 1 kV for 24-VAC/DC and 48-VAC/DC models, 3 kV for all other models. Between current-carrying metal parts and exposed non-current-carrying metal parts): 1.5 kV for 24-VAC/DC and 48-VAC/DC models, 4.5 kV for all other models. Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise): ±1.5 kV (between power supply terminals) Noise immunity Static immunity Malfunction: 4 kV, Destruction: 8 kV Destruction 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions Vibration resistance Malfunction 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions Shock resistance Destruction 1,000 m/s2 3 times each in 6 directions Life expectancy Mechanical 10 million operations min. (under no load at 1,200 operations/h) Malfunction 100 m/s2 3 times each in 6 directions Electrical IP30 (Terminal block: IP20) Weight Approx. 120 g 80 70 60 d = 50 mm d = 10 mm 50 d = 5 mm 40 30 d = 0 mm 20 10 0 1 2 3 4 Tested Timer: H3DK-H Applied voltage: 240 VAC Installation pitch: 0, 5, 10, and 50 mm Safety standards cURus: UL 508/CSA C22.2 No. 14 EN 50274: Finger protection, back-of-hand proof EN 61812-1: Pollution degree 2, Overvoltage category III CCC: Pollution degree 2, Overvoltage category II, section DB14048.5-2008 part 5-1 LR: Test Specification No. 1-2002 Category ENV 1.2 EMC (EMI)EN61812-1 Radiated Emissions:EN 55011 class B Emission AC Mains:EN 55011 class B Harmonic Current:EN 61000-3-2 Voltage Fluctuations and Flicker:EN61000-3-3 (EMS)EN61812-1 ESD Immunity:EN 61000-4-2: 6 kV contact discharge, 8 kV air discharge Radiated Radio-Frequency Electromagnetic Field Immunity (AM Radio Waves): EN 61000-4-3: 10 V/m (80 MHz to 1 GHz) Burst Immunity:EN 61000-4-4: 2 kV power line, 1 kV I/O signal line Surge Immunity:EN 61000-4-5: 2 kV common mode, 1 kV differential mode ■ I/O Input None Control output 5 The Timer operates as soon as the Timer is turned ON. The Timer starts timing when the power is turned OFF and the output is turned OFF when the time set on the dial elapses. 6 Load current (A) Testing Method ■ Applicable standards 22 The relation between the installation pitch and the load current is shown in the following graph. (Except for the H3DK-GE) If Timer is used under load conditions that exceed the specified values, the temperature inside the Timer will increase, reducing the life expectancy of internal parts. 100,000 operations min. (5 A at 250 VAC, resistive load at 1,200 operations/h) Degree of protection Output ● Installation Pitch and Output Switching Capacity (Reference Values) Ambient temperature (°C) ±1% of FS max. (±1% ±10 ms max. at 1.2-s range) Maximum ambient operating temperature in specifications Accuracy of operating time Test timer 1 DIN Track Test timer 2 Test timer 3 Test timer 4 Timer installation pitch: d Test timer 5 H3DK-H Connections ■ Block Diagrams ■ Terminal Arrangement H3DK-H H3DK-H A1 AC (DC) input Indicator circuit 15 Time specification switches R1 15 Power supply circuit Oscillation circuit Counting circuit Output circuit Power interruption detection circuit 18 18 16 16 A2 (DIN notation) A1 A2 15 16 18 Note 1: The above figure shows the terminal arrangement for a 24 to 48-VAC/DC model. Models with 100 to 120-VAC or 200 to 240-VAC power input do not have a DC input. Note 2: The power supply terminals do not have polarity. Nomenclature H3DK-H Bottom View Front View Note 1. Use solid wire (2.5 mm2 max.) or ferrules with insulative sleeves to connect to the terminals. To maintain the withstand voltage after connecting the terminals, insert no more than 8 mm of exposed conductor into the terminal. User label attachment location Time range switch (S Series: ×0.1 or ×1, L Series: ×1 or ×10) Power indicator (green) (Lit while the power is ON.) Using Solid Wire (2.5 mm2 Max.) Main dial (for setting the time) Using Ferrule with Insulative Sleeve Terminal block (See notes 1 and 2.) 8 mm max. 8 mm max. Recommended Ferrules Phoenix Contact • AI@@@ Series • AI-TWIN@@@ Series Note 2. Screw Tightening Torque Recommended torque: 0.49 N·m Maximum torque: 0.98 N·m 23 H3DK-H Dimensions (Unit: mm) ■ Timers H3DK-H 100 88.2 22.5 69.1 4 79 65.6 52 89.4 ■ Track Mounting Products (Sold Separately) Refer to page 28 for details. Operating Procedures ■ Basic Operation Setting the Time Ranges Setting the Time ● Setting the Time Ranges ● Setting the Time The scale multiplier can be changed with the timer range switch. It can be changed between ×0.1 s and ×1 s for an S-series Timer and between ×1 s and ×10 s for an L-series Timer. The operation time is set with the main dial. Main dial Time range switch ■ Timing Charts Rt t ON Power (A1 and A2) OFF Output relay: NO (15 and 18) ON OFF Indicator ON OFF t: Set time Rt: Minimum power-ON time S Series: 0.1 s min. L Series: 0.3 s min. (The output may never turn ON if the power is not ON for at least this time.) 24 Rt t H3DK Safety Precautions ● Refer to Safety Precautions for All Timers. Note: The following is common for all H3DK models. Caution Switching arcs or relay heating may cause fire or explosion. Do not use the Timer in the presence of inflammable or explosive gases. The H3DK Series uses a transformerless power supply system. An electrical shock may occur if an input terminal is touched while power is being supplied. The inrush current will depend on the type of load and may influence the contact switching frequency and number of operations. Check both the rated current and the inrush current, and allow leeway in the circuit design. The life of the output relay largely depends on the switching current and other switch conditions. Consider the actual application conditions and do not exceed the rated load or electrical life. If the output relay is used beyond its service life, the contacts may fuse or burning may occur. Also, never exceed the rated load current. When using a heater, also place a thermal switch in the load circuit. Do not remove the external case. Minor electric shock, fire, or equipment failure may sometimes occur. Do not disassemble, modify, or repair the Timer or touch any internal parts. Precautions for Safe Use • Use ferrules to wire the H3DK. If stranded wires are used, wire scraps may enter the Timer, possibly shorting the circuits. • Rapid changes in temperature or high humidity may cause condensation in Timer circuits, possibly resulting in malfunction or damage to components. Check the application environment. • Store the Timer within the rated ranges given for the Timer model you are using. If the Timer is stored below −20°C, allow it to warm up for three hours at room temperature before turning ON the power supply. • Use the Timer within the ambient operating temperature and ambient operating humidity ranges given for the Timer model you are using. • Use the Time within the characteristics for water and oil exposure given for the Timer model you are using. • Do not use the Timer in locations subject to excessive dust, corrosive gas, or direct sunlight. • Do not use the Timer in locations subject to vibration and shock. Long-term exposure may damage the Timer due to stress. • Separate the Timer from any sources of excessive static electricity, such as forming materials and pipes carrying power or liquid materials. • Maintain the variations in the power supply voltage to within the specified allowable range. • If a voltage that exceeds the rating is applied, internal components may be destroyed. • Wire all terminals correctly. • Use only the specified wires for wiring. Applicable wire gauge: AWG18 to AWG22 • Install and clearly label a switch or circuit breaker so that the operator can quickly turn OFF the power supply. • If the Timer is left in the timed out condition for a long period of time at high temperatures, internal components (such as electrolytic capacitors) may deteriorate quickly. • The exterior of the Timer may be damaged by organic solvents (such as thinners or benzene), strong alkali, or strong acids. • For Timers with AC power input, use a commercial power supply for the power supply voltage. Although some inverters give 50/60 Hz as the output frequency, do not use an inverter output as the power supply for a Timer. Doing so may result in smoking or burning due to internal temperature increases in the Timer. • Use the same type of wiring for all Timer wiring. • When disposing of the Timer, observe all local ordinances as they apply. • The Timer may not operate properly in locations that are subject to sulfide gas, such as in sewers or incinerators. Products that are suitable for operation in sulfide gas are not available for OMRON Timers or general control devices. Seal the Timer to isolate it from sulfide gas. If the Timer cannot be sealed, OMRON can make special products with resistance to sulfide gas for some Timers. Ask your OMRON representative for details. • Confirm that the power and output indicators are operating normally. Depending on the operating environment, the indicators and plastic parts may deteriorate faster than expected, causing the indicators to fail. Periodically perform inspections and replacements. 25 H3DK Precautions for Correct Use ● Changing Switch Settings Do not change the time unit, time scale, operating mode, or INIT/ TIME switch while the Timer is in operation. Doing so may result in malfunction. Turn OFF the power supply before changing the setting of any switch. ● Mounting and Dismounting • Although there are no particular mounting restrictions, the Timer should be mounted as horizontally as possible. • When mounting the Timer on a mounting Track, loosen the two hooks, press the Timer onto the Track, and then insert the hooks. Hook ● Relationship between Input and Power Supply Circuits (H3DK-M1/-M2) B1 AC/DC power supply Input circuit A1 Power supply circuit A2 • The input circuit and the power supply circuit are configured independently. The input circuit can be turned ON and OFF without considering the ON/OFF state of the power supply. A voltage equivalent to the power supply voltage is also applied to the input circuit. • If a relay or transistor is connected to two or more Timers, the input terminals of those Timers must be wired properly so that they will not be different in phase or the terminals will be shortcircuited to one another. Always use the same power supply phases. Contact or transistor for external input signal Hook • When removing the Timer, pull out the two hooks, and then remove the Timer from the Track A1 B1 Hook H3DK Power A2 A1 B1 Hook 30 mm min. A2 • It will be easier to mount and dismount the Timer if a distance of 30 mm or more is provided between the bottom of the Timer and other equipment. Contact or transistor for external input signal A1 ● Power Supply B1 • The power supply can be connected to the power input terminals without considering polarity. • A DC power supply can be connected if its ripple factor is 20% or less and the average voltage is within the allowable voltage fluctuation range of the Timer. • For the power supply of the input device, use an isolating transformer in which the primary and secondary windings are mutually isolated and the secondary winding is not grounded. (H3DK-M1 and H3DK-M2 only) H3DK Power Rectifier circuit A2 Circuit Isolation transformer is required. • The H3DK-H has a large inrush current. Provide sufficient power supply capacity. If the power supply capacity is too small, there may be delays in turning ON the output. 26 H3DK Power A2 A1 B1 H3DK A2 ● Environment A1 B1 Start input H3DK • When using the Timer in an area with excessive electronic noise, separate the Timer and input device as far as possible from the noise sources. It is also recommended to shield the input signal wiring to prevent electronic interference. • The external impulse voltage entering across the power supply terminals has been checked against a ±1.2×50 µs standard waveform according to JEC-210, Impulse Voltage/Current Test, of The Institute of Electrical Engineers of Japan. Surge or noise superimposed on the power supply may damage internal components or cause them to malfunction. We recommend that you check the circuit waveform and use surge absorbers. The effects on components depend on the type of surge and noise that are generated. Always perform testing with the actual equipment. H3DK ● Wiring The H3DK-H acts like a high-impedance circuit. Therefore, the Timer may not reset if it is influenced by inductive voltage. To eliminate inductive voltage, the wires connected to the Timer must be as short as possible and should not be installed parallel to power lines. If the Timer is influenced by inductive voltage that is 30% or more of the rated voltage, connect a CR filter with a capacitance of approximately 0.1 µF and a resistance of approximately 120 Ω or a bleeder resistor between the power supply terminals. If there is any residual voltage due to current leakage, connect a bleeder resistor between the power supply terminals. • • ● Operating Frequency • The H3DK-H may malfunction if it is used as shown below. Do not use the H3DK-H in these ways. Timer Repeatedly Times Out in Cycles of 3 s or Less 3s or less 3s or less • • Power • Output In the above case, use the H3DK-M2/-M1 in D mode (signal OFF delay). ● DC Power Consumptions (Reference Information) H3DK-M2/-S2 At 24 VDC: 1.2 W max. H3DK-M1/-S1 At 24 VDC: 1.1 W max. H3DK-F At 24 VDC: 1.1 W max. H3DK-G At 24 VDC: 1.2 W max. H3DK-HBS/-HBL At 24 VDC: 1.2 W max. • • • • ● Other Precautions • If the Timer is mounted on a control panel, dismount the Timer from the control panel before carrying out a voltage withstand test between the electric circuits and non-current-carrying EN/IEC Standard Compliance • Refer to the datasheet for the H3DK for cable selection and other conditions for compliance with EMC standards. • The power supply terminals and input terminals are not isolated. There is basic insulation between the power supply terminals and output terminals. • If double or reinforced insulation is required, use the double or reinforced insulation defined in IEC 60664 that is suitable for the maximum applied voltage for the clearance, solid insulation, and other factors. • metal parts of the Timer. (Otherwise, the internal circuits of the Timer may be damaged.) The H3DK-H uses a latching relay for the output. Shock, such as dropping the H3DK-H during shipment or handling, can cause the output contacts to reverse to the neutral position. Check the output status with a tester before using the H3DKH. The life expectancy of the control output contacts is greatly affected by switching conditions. Always confirm operation using the actual conditions and equipment before using the Timer and make sure that the number of switching operations presents no problems in performance. If Timer application is continued after performance has deteriorated, insulation failure between circuits, burning of the control output relay, or other problem will eventually occur. If the power supply voltage is gradually increased, a power reset may occur or the Timer may time out. Use a switch, relay, or other device with contacts to apply the power supply voltage all at once. Make sure that residual voltage or inductive voltage is not applied after the power turns OFF. Error in the operation time of the Timer is given as a percentage of the full-scale time. The absolute value of the error will not change even if the set time is changed. Therefore, always use the Timer with the set time set as close as possible to the full-scale value of the set time range. When switching a microload, check the specified minimum load given for the Timer model you are using. When setting the operating time, do not turn the dial beyond the scale range. If better accuracy is required in the set time, adjust the dial while measuring the operation time. If the Timer is reset immediately after timing out, make sure that the circuit configuration allows sufficient resetting time. Errors will occur in the sequence if there is not sufficient resetting time. When directly switching a DC load, the switching capacity will be lower than when switching an AC load. Precautions for Compliance with UL Standards and CSA Standards Notice to Users of the H3DK in the USA and Canada Please use the following installation information instead of the general information in this document in order to use the product under certified conditions of UL and CSA when the product is installed in the USA or Canada. These conditions are required by NFPA 70, National Electrical Code in the USA and the Canadian Electrical Code, Part I in Canada and may vary from information given in this document. • Use an isolated source for power input for the H3DK-@A. Use an isolated source with external overcurrent protection of 16 A maximum for the source and input. (The input is applicable to the H3DK-M only.) • Environment Surrounding Air Temperature: 55°C • Power Supply: The inputs are non-isolated (applicable to H3DK-M only). The same power supply as the main power source must be used for that for input. • Pollution Degree Pollution degree II 27 H3DK Track Mounting Products (Sold Separately) DIN Track PFP-100N PFP-50N (Unit: mm) 7.3±0.15 4.5 35±0.3 15 25 10 25 25 1,000 (500)* 10 25 27±0.15 15 (5)* 1 *Dimensions in parentheses are for the PFP-50N. DIN Track PFP-100N2 16 4.5 35±0.3 27 15 End Plate PFP-M 25 10 25 25 1,000 25 10 15 M4x8 panhead screw 50 1.8 1 35.5 35.3 1.8 11.5 10 1.3 4.8 M4 screw and washer Spacer PFP-S 16 12 5 34.8 44.3 16.5 Note 1: Order the above products in multiples of 10. Note 2: The Tracks conform to DIN standards. 28 29.2 1 10 6.2 24 1.5 Warranty and Application Considerations Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2010 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Printed in Japan CSM_3_1_0212 Cat. No. L118-E1-02 0910