Series HA60/HD60 25-125Amp • 600 Vac • AC Output • Zero Voltage and Random Turn-On Switching • Panel Mount • 1200V Blocking Capability • 600Vac - the preferred choice in Canada HA6025 HD6025 HA6050 HD6050 HA6090 HD6090 HA60125 HD60125 600 600 600 600 48-660 48-660 48-660 48-660 Max. Load Current ➂ [Arms] 25 50 90 125 Min. Load Current, [mArms] 40 40 40 150 Transient Overvoltage [Vpk] 1200 1200 1200 1200 Max. Surge Current, (16.6ms) [Apk] 250 625 1,200 1,750 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.7 1.7 1.7 1.7 Thermal Resistance Junction to Case (RθJC) [˚C/W] 1.02 0.63 0.28 0.22 Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 260 1,620 6,000 12,700 5 5 5 5 500 500 500 500 MODEL NUMBERS AC CONTROL D C C ONTROL Featuring state-of-the-art Surface Mount Technology, these SPST-NO relays deliver proven reliability in the most demanding applications. Output consists of an SCR AC switch and is available in zero-cross, random turn-on (phase controllable) and versions with either AC or DC input (coil) control. Manufactured in Crydom’s ISO 9002 Certified facility for optimum product performance and reliability. OUTPUT SPECIFICATIONS ➀ Nominal Line Voltage (±10%) [Vrms] Operating Voltage Range (47-63 Hz) [Vrms] Max. Off-State Leakage Current @ Rated Voltage [mArms] ➆ Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁ Max. Turn-On Time➄ 1/2 Cycle (DC Input), 10.0 msec (AC Input) Max. Turn-Off Time 1/2 Cycle (DC Input), 40.0 msec (AC Input) 0.5 Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ 0.5 0.5 AC CONTROL (A PREFIX)➃ AC CONTROL (D PREFIX) 3-32 Vdc 90-280 Vrms (60Hz) 18-36 Vrms Max. Reverse Voltage -32 Vdc --- --- Max. Turn-On Voltage 3.0 Vdc 90 Vrms 18 Vrms Min. Turn-Off Voltage 1.0 Vdc 10 Vrms 4.0 Vrms See Note ➅ 60K Ohms 9.0K Ohms 2.0 mA➅ 2mA @ 120 Vrms, 4mA @ 240 Vrms 3mA @ 24 Vrms Control Voltage Range Nominal Input Impedance Typical Input Current GENERAL NOTES DC CONTROL 0.5 ©1998 CRYDOM CORP, Specifications subject to change without notice. ➀ All parameters at 25ºC unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ 24 Vac Input option, E suffix. ➄ Turn-on time for random turn-on versions is 0.02 msec (DC Control Models). ➅ Input circuitry incorporates active current limiter. For recommended applications and more information contact: ➆ No internal snubber. USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280 FastFax Document No.159 SERIES HA/HD60.032698, PAGE 1 OF 3 (E SUFFIX) Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected] WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH, Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: [email protected] Series HA60/HD60 25-125Amp • 600 Vac • AC Output GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc Max. Capacitance Input/Output 8 pF Ambient Operating Temperature Range -40 to 80ºC Ambient Storage Temperature Range -40 to 125ºC MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Terminals: Thermally Conductive Epoxy Screws and Saddle Clamps Furnished, Unmounted AVAILABLE OPTIONS E 24 VAC Input (18-36 Vac) Example: HA6025E -10 Random Turn-On (AC & DC Control) Phase Controllable (DC Control) Example: HD6090-10 F Faston Terminals (Up to 50 Amp Models) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1 1.87 (47.5) 1.10 (27.9) .45 (11.4) 8-32 TERMINAL (2 PLACES ) OUTPUT 2 SOLID-STATE RELAY -4 Fastons: Single pair (up to 25A) Double pair* (up to 50A). *Caution: User must connect to both pairs 3 INPUT 1.00 (25.4) 1.80 (45.7) BASE PLATE .125 (3.2) Screw Torque Requirements: 6-32 Screws - 10 in./lbs., 8-32 and 10-32 Screws - 20in./lbs. (Screws dry without grease.) + 6-32 TERMINAL (2 PLACES) 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1 OUTPUT 2 2.30 (58.4) 1.70 (43.2) 4 BASE PLATE .125 (3.2) .78 (19.8) .90 (22.9) FASTON TERMINAL .250 X .032 (2 PLCS.) .87 REF. (22.2) 1.87 (47.5) Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. 2.30 (58.4) 1.70 (43.2) INPUT 1.00 (25.4) 1.80 (45.7) 3 FASTON TERMINAL .187 X .032 (2 PLCS.) .78 (19.8) .90 (22.9) All dimensions are in inches (millimeters) ©1998 CRYDOM CORP, Specifications subject to change without notice. APPROVALS UL E116950 CSA LR81689 VDE 10143 UG FastFax Document No.159 SERIES HA/HD60.032698, PAGE 2 OF 3 For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected] WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH, Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: [email protected] Series HA60/HD60 25-125Amp • 600 Vac • AC Output CURRENT DERATING CURVES 50A 25A 60 95 1ºC/W .5ºC/W 3ºC/W 2ºC/W 20 15 110 10 NO HEATSINK 5 Power Dissipation 1.5ºC/W 40 100 2ºC/W 110 20 120 120 NO HEATSINK 0 0 15 20 25 20 40 60 10 80 90A .5ºC/W 30 40 50 20 .4ºC/W 100 1ºC/W 110 40 60 80 160 90 .2ºC/W 80 40 Max Ambient Temp. [ºC] 125A 90 120 20 Load Current [Arms] Max Ambient Temp. [ºC] .4ºC/W Power Dissipation 10 Load Current [Arms] Base Plate Temp [ºC] 5 Power Dissipation 90 120 .5ºC/W .2ºC/W 100 80 1ºC/W 110 40 120 Base Plate Temp [ºC] Power Dissipation 100 Base Plate Temp [ºC] 1ºC/W 25 Base Plate Temp [ºC] 30 120 0 0 20 40 60 80 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [ºC] 30 60 90 120 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [ºC] ©1998 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No.159 SERIES HA/HD60.032698, PAGE 3 OF 3 For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected] WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH, Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: [email protected]