ETC HD6090-E

Series HA60/HD60
25-125Amp • 600 Vac • AC Output
• Zero Voltage and Random
Turn-On Switching
• Panel Mount
• 1200V Blocking Capability
• 600Vac - the preferred
choice in Canada
HA6025
HD6025
HA6050
HD6050
HA6090
HD6090
HA60125
HD60125
600
600
600
600
48-660
48-660
48-660
48-660
Max. Load Current ➂ [Arms]
25
50
90
125
Min. Load Current, [mArms]
40
40
40
150
Transient Overvoltage [Vpk]
1200
1200
1200
1200
Max. Surge Current, (16.6ms) [Apk]
250
625
1,200
1,750
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.7
1.7
1.7
1.7
Thermal Resistance Junction to Case (RθJC) [˚C/W]
1.02
0.63
0.28
0.22
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
260
1,620
6,000
12,700
5
5
5
5
500
500
500
500
MODEL NUMBERS
AC CONTROL
D C C ONTROL
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications.
Output consists of an SCR AC switch
and is available in zero-cross, random
turn-on (phase controllable) and versions with either AC or DC input (coil)
control.
Manufactured in Crydom’s ISO 9002
Certified facility for optimum product
performance and reliability.
OUTPUT SPECIFICATIONS ➀
Nominal Line Voltage (±10%) [Vrms]
Operating Voltage Range (47-63 Hz) [Vrms]
Max. Off-State Leakage Current @ Rated Voltage [mArms] ➆
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁
Max. Turn-On Time➄
1/2 Cycle (DC Input), 10.0 msec (AC Input)
Max. Turn-Off Time
1/2 Cycle (DC Input), 40.0 msec (AC Input)
0.5
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
0.5
0.5
AC CONTROL
(A PREFIX)➃
AC CONTROL
(D PREFIX)
3-32 Vdc
90-280 Vrms (60Hz)
18-36 Vrms
Max. Reverse Voltage
-32 Vdc
---
---
Max. Turn-On Voltage
3.0 Vdc
90 Vrms
18 Vrms
Min. Turn-Off Voltage
1.0 Vdc
10 Vrms
4.0 Vrms
See Note ➅
60K Ohms
9.0K Ohms
2.0 mA➅
2mA @ 120 Vrms, 4mA @ 240 Vrms
3mA @ 24 Vrms
Control Voltage Range
Nominal Input Impedance
Typical Input Current
GENERAL NOTES
DC CONTROL
0.5
©1998 CRYDOM CORP, Specifications subject to change without notice.
➀ All parameters at 25ºC unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ 24 Vac Input option, E suffix.
➄ Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
➅ Input circuitry incorporates active current limiter.
For recommended applications and more information contact:
➆ No internal snubber.
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
FastFax Document No.159
SERIES HA/HD60.032698, PAGE 1 OF 3
(E SUFFIX)
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected]
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: [email protected]
Series HA60/HD60
25-125Amp • 600 Vac • AC Output
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
Max. Capacitance Input/Output
8 pF
Ambient Operating Temperature Range
-40 to 80ºC
Ambient Storage Temperature Range
-40 to 125ºC
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Terminals:
Thermally Conductive Epoxy
Screws and Saddle Clamps Furnished, Unmounted
AVAILABLE OPTIONS
E
24 VAC Input (18-36 Vac)
Example: HA6025E
-10
Random Turn-On (AC & DC Control)
Phase Controllable (DC Control)
Example: HD6090-10
F
Faston Terminals (Up to 50 Amp Models)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1
1.87
(47.5)
1.10
(27.9)
.45
(11.4)
8-32 TERMINAL
(2 PLACES )
OUTPUT
2
SOLID-STATE RELAY
-4
Fastons:
Single pair (up to 25A)
Double pair* (up to 50A).
*Caution: User must connect to both pairs
3
INPUT
1.00
(25.4)
1.80
(45.7)
BASE PLATE
.125 (3.2)
Screw Torque Requirements:
6-32 Screws - 10 in./lbs.,
8-32 and 10-32 Screws - 20in./lbs.
(Screws dry without grease.)
+
6-32 TERMINAL
(2 PLACES)
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1
OUTPUT
2
2.30
(58.4)
1.70
(43.2)
4
BASE PLATE
.125 (3.2)
.78
(19.8)
.90
(22.9)
FASTON TERMINAL
.250 X .032 (2 PLCS.)
.87 REF.
(22.2)
1.87
(47.5)
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the details.
2.30
(58.4)
1.70
(43.2)
INPUT
1.00
(25.4)
1.80
(45.7)
3
FASTON
TERMINAL
.187 X .032
(2 PLCS.)
.78
(19.8)
.90
(22.9)
All dimensions are in inches (millimeters)
©1998 CRYDOM CORP, Specifications subject to change without notice.
APPROVALS
UL
E116950
CSA LR81689
VDE 10143 UG
FastFax Document No.159
SERIES HA/HD60.032698, PAGE 2 OF 3
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected]
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: [email protected]
Series HA60/HD60
25-125Amp • 600 Vac • AC Output
CURRENT DERATING CURVES
50A
25A
60
95
1ºC/W .5ºC/W
3ºC/W 2ºC/W
20
15
110
10
NO HEATSINK
5
Power Dissipation
1.5ºC/W
40
100
2ºC/W
110
20
120
120
NO HEATSINK
0
0
15
20
25
20
40
60
10
80
90A
.5ºC/W
30
40
50
20
.4ºC/W
100
1ºC/W
110
40
60
80
160
90
.2ºC/W
80
40
Max Ambient Temp. [ºC]
125A
90
120
20
Load Current [Arms]
Max Ambient Temp. [ºC]
.4ºC/W
Power Dissipation
10
Load Current [Arms]
Base Plate Temp [ºC]
5
Power Dissipation
90
120
.5ºC/W
.2ºC/W
100
80
1ºC/W
110
40
120
Base Plate Temp [ºC]
Power Dissipation
100
Base Plate Temp [ºC]
1ºC/W
25
Base Plate Temp [ºC]
30
120
0
0
20
40
60
80
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [ºC]
30
60
90 120
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [ºC]
©1998 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No.159
SERIES HA/HD60.032698, PAGE 3 OF 3
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected]
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: [email protected]