Series HA60/HD60 25-125Amp • 600 Vac • AC Output • Zero Voltage and Random Turn-On Switching • Panel Mount • 1200V Blocking Capability • 600Vac - the preferred choice in Canada • Integrated Overvoltage Protection by Automatic Self Turn-On (Suffix P) HA6025 HD6025 HA6050 HD6050 HA6090 HD6090 HA60125 HD60125 OUTPUT SPECIFICATIONS ➀ Nominal Line Voltage (±10%) [Vrms] 600 600 600 600 Operating Voltage Range (47-63 Hz) [Vrms] 48-660 48-660 48-660 48-660 Max. Load Current ➂ [Arms] 25 50 90 125 Min. Load Current, [mArms] 40 40 40 150 Transient Overvoltage [Vpk] 1200 1200 1200 1200 Max. Surge Current, (16.6ms) [Apk] 250 625 1,200 1,750 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.7 1.7 1.7 1.7 Thermal Resistance Junction to Case (R θJC) [˚ C/W] 1.02 0.63 0.28 0.22 Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 260 1,620 6,000 12,700 5 5 5 5 500 500 500 500 MODEL NUMBERS AC CONTROL D C CONTROL Featuring state-of-the-art Surface Mount Technology, these SPST-NO relays deliver proven reliability in the most demanding applications. Output consists of an SCR AC switch and is available in zero-cross, random turn-on (phase controllable) and versions with either AC or DC input (coil) control. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. Max. Off-State Leakage Current @ Rated Voltage [mArms] ➆ Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁ Max. Turn-On Time ➄ 1/2 Cycle (DC Input), 10.0 msec (AC Input) 1/2 Cycle (DC Input), 40.0 msec (AC Input) Max. Turn-Off Time 0.5 Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ DC CONTROL (D PREFIX) 0.5 0.5 0.5 AC CONTROL (A PREFIX) ➃ AC CONTROL (E SUFFIX) Control Voltage Range 3-32 Vdc 90-280 Vrms (60Hz) 18-36 Vrms Max. Reverse Voltage -32 Vdc --- --- Max. Turn-On Voltage 3.0 Vdc 90 Vrms 18 Vrms Min. Turn-Off Voltage 1.0 Vdc 10 Vrms 4.0 Vrms See Note ➅ 60K Ohms 9.0K Ohms 2.0 mA ➅ 2mA @ 120 Vrms, 4mA @ 240 Vrms 3mA @ 24 Vrms Nominal Input Impedance Typical Input Current © 2002 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25˚C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ 24 Vac Input option, E suffix. ➄ Turn-on time for random turn-on versions is 0.02 msec (DC Control Models). ➅ Input circuitry incorporates active current limiter. ➆ No internal snubber. FastFax Document No.159 SERIES HA/HD60. Rev. 031802 PAGE 1 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: [email protected] WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected]. GERMANY: +49 (0)180 3000 506 Series HA60/HD60 25-125Amp • 600 Vac • AC Output GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Thermally Conductive Epoxy Terminals: AVAILABLE OPTIONS E 24 VAC Input (18-36 Vac) Example: HA6025E F Screws and Saddle Clamps Furnished, Unmounted Faston Terminals (Up to 50 Amp Models) Example: HD6050F Input Status LED. Agencies Approval Pending Example: HD6050G Note: Control Voltage Range 4.5-32Vdc for DC Control Models. G P Internal Overvoltage Protection. Relay Will Self Trigger Between 900-1200 Vpk. Not Suitable For Capacitive Loads. Agencies Approval Pending. Example: HD6025P -10 Random Turn-On (AC & DC Control) Phase Controllable (DC Control) Example: HD6090-10 Ordering System: Combination of the suffixes should be made in the following order: EFPG-10. Example: HA6050EFPG-10 Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1 Screw Torque Requirements: 6-32 Screws - 10 in./lbs., 8-32 and 10-32 Screws - 20in./lbs. (Screws dry without grease.) 1.87 (47.5) 8-32 TERMINAL (2 PLACES ) OUTPUT 2 SOLID-STATE RELAY -4 + 3 INPUT 1.00 (25.4) 1.80 (45.7) BASE PLATE .125 (3.2) Fastons: Single pair (up to 25A) Double pair* (up to 50A). * Caution: User must connect to both pairs 6-32 TERMINAL (2 PLACES) 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1 .78 (19.8) .90 (22.9) FASTON TERMINAL .250 X .032 (2 PLCS.) .87 REF. (22.2) OUTPUT 2 1.87 (47.5) 2.30 (58.4) 1.70 (43.2) 4 BASE PLATE .125 (3.2) 2.30 (58.4) 1.70 (43.2) INPUT 1.00 (25.4) 1.80 (45.7) 3 FASTON TERMINAL .187 X .032 (2 PLCS.) .78 (19.8) .90 (22.9) All dimensions are in inches (millimeters) APPROVALS UL E116950 CSA LR81689 VDE 10143 UG FastFax Document No.159 SERIES HA/HD60. Rev. 031802 PAGE 2 OF 3 © 2002 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: [email protected] WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected]. GERMANY: +49 (0)180 3000 506 Series HA60/HD60 25-125Amp • 600 Vac • AC Output CURRENT DERATING CURVES 50A 25A 60 95 1˚C/W .5˚C/W 3˚C/W 2˚C/W 20 15 110 10 NO HEATSINK 5 Power Dissipation 1.5˚C/W 40 100 2˚C/W 110 20 120 120 NO HEATSINK 0 0 15 20 25 20 40 60 10 80 90A .5˚C/W 30 40 50 20 .4˚C/W 100 1˚C/W 110 40 60 80 160 90 .2˚C/W 80 40 Max Ambient Temp. [˚C] 125A 90 120 20 Load Current [Arms] Max Ambient Temp. [˚C] .4˚C/W Power Dissipation 10 Load Current [Arms] Base Plate Temp [˚C] 5 Power Dissipation 90 120 .5˚C/W .2˚C/W 100 80 1˚C/W 110 40 120 0 Base Plate Temp [˚C] Power Dissipation 100 Base Plate Temp [˚C] 1˚C/W 25 Base Plate Temp [˚C] 30 120 0 20 40 60 80 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] 30 60 90 120 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] © 2002 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No.159 SERIES HA/HD60. Rev. 031802 PAGE 3 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: [email protected] WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected]. GERMANY: +49 (0)180 3000 506