ETC HD74LV2G126A

HD74LV2G126A
Dual Bus Buffer with 3–state Output
ADE-205-348 (Z)
1st. Edition
May 2000
Description
The HD74LV2G126A has dual bus buffer with 3–state output in a 8 pin package. Output is disabled when
the associated output enable (OE) input is low. To ensure the high impedance state during power up or
power down, OE should be connected to VCC through a pull-down resistor; the minimum value of the
resistor is determined by the current souring capability of the driver. Low voltage and high speed operation
is suitable for the battery powered products (e.g., notebook computers), and the low power consumption
extends the battery life.
Features
• The basic gate function is lined up as hitachi uni logic series.
• Supplied on emboss taping for high speed automatic mounting.
• Electrical characteristics equivalent to the HD74LV126A
Supply voltage range : 1.65 to 5.5 V
Operating temperature range : –40 to +85°C
• All inputs VIH (Max.) = 5.5 V (@VCC = 0 V to 5.5 V)
All outputs VO (Max.) = 5.5 V (@VCC = 0 V)
• Output current ±6 mA (@VCC = 3.0 V to 3.6 V), ±12 mA (@VCC = 4.5 V to 5.5 V)
• All the logical input has hysteresis voltage for the slow transition.
HD74LV2G126A
Outline and Article Indication
• HD74LV2G126A
Index band
Lot No.
Y M W
L 2 6
US–8
Type No.
Function Table
Inputs
Output Y
OE
A
H
H
H
H
L
L
L
X
Z
H : High level
L : Low level
X : Immaterial
Z : High impedance
2
Y : Year code
(the last digit of year)
M : Month code
W : Week code
HD74LV2G126A
Pin Arrangement
G1
1
8
VCC
A1
2
7
G2
Y2
3
6
Y1
GND
4
5
A2
(Top view)
Absolute Maximum Ratings
Item
Symbol
Ratings
Unit
Supply voltage
VCC
–0.5 to 7.0
V
Input voltage
VIN
–0.5 to 7.0
V
Output voltage
VOUT
–0.5 to VCC + 0.5
V
–0.5 to 7.0
Test Conditions
Output : H or L
VCC : OFF or Output : Z
Input diode current
I IK
–20
mA
Output diode current
I OK
±50
mA
Output current
I OUT
±25
mA
VCC, GND current
I CC or IGND
±50
mA
Power dissipation
PT
200
mW
Storage temperature
Tstg
–65 to 150
°C
3
HD74LV2G126A
Recommended Operating Conditions
Item
Symbol
Ratings
Unit
Supply voltage
VCC
1.65 to 5.5
V
Input voltage
VIN
0 to 5.5
V
Output voltage
VOUT
0 to V CC
V
Operating temperature
Topr
–40 to +85
°C
Input rise / fall time
t r, t f
0 to 300 (VCC = 1.65 to 1.95 V)
ns
0 to 200 (VCC = 2.3 to 2.7 V)
0 to 100 (VCC = 3.0 to 3.6 V)
0 to 20 (VCC = 4.5 to 5.5 V)
4
HD74LV2G126A
Electrical Characteristic
• Ta = –40 to 85°C
Item
Symbol VCC (V) *
Input voltage
VIH
VIL
Hysteresis voltage VH
Output voltage
VOH
VOL
Min
Typ
1.65 to 1.95 VCC×0.75 —
Max
Unit
—
V
Test condition
2.3 to 2.7
VCC×0.7
—
—
3.0 to 3.6
VCC×0.7
—
—
4.5 to 5.5
VCC×0.7
—
—
1.65 to 1.95 —
—
VCC×0.25
2.3 to 2.7
—
—
VCC×0.3
3.0 to 3.6
—
—
VCC×0.3
4.5 to 5.5
—
—
VCC×0.3
1.8
—
0.25
—
2.5
—
0.30
—
3.3
—
0.35
—
5.0
—
0.45
—
Min to Max
VCC–0.1
—
—
1.65
1.4
—
—
I OH = –1 mA
2.3
2.0
—
—
I OH = –2 mA
3.0
2.48
—
—
I OH = –6 mA
4.5
3.8
—
—
I OH = –12 mA
Min to Max
—
—
0.1
I OL = 50 µA
1.65
—
—
0.3
I OL = 1 mA
2.3
—
—
0.4
I OL = 2 mA
3.0
—
—
0.44
I OL = 6 mA
4.5
—
—
0.55
I OL = 12 mA
V
VT+ – VT–
V
I OH = –50 µA
Input current
I IN
0 to 5.5
—
—
±1
µA
VIN = 5.5 V or GND
Off state output
current
I OZ
5.5
—
—
±5
µA
VO = VCC or GND
Quiescent
supply current
I CC
5.5
—
—
10
µA
VIN = VCC or GND,
IO = 0
Output leakage
current
I OFF
0
—
—
5
µA
VO = 5.5 V
3.3
—
3.0
—
pF
VIN = VCC or GND
Input capacitance CIN
Note: For conditions shown as Min or Max, use the appropriate values under recommended operating
conditions.
5
HD74LV2G126A
Switching Characteristics
• VCC = 1.8 ± 0.15 V
Item
Symbol
Ta = 25°C
Ta = –40 to 85°C
Min
Typ
Max
Min
Max
Propagation
t PLH
—
13.5
23.5
1.0
26.0
delay time
t PHL
—
19.0
33.0
1.0
36.0
Enable time
t ZH
—
13.7
26.5
1.0
29.0
t ZL
—
20.5
36.0
1.0
38.0
t HZ
—
8.3
20.0
1.0
22.5
t LZ
—
13.0
29.5
1.0
32.0
Disable time
Unit Test
ns
FROM
TO
Conditions (Input)
(Output)
CL = 15 pF
A
Y
OE
Y
OE
Y
FROM
TO
CL = 50 pF
ns
CL = 15 pF
CL = 50 pF
ns
CL = 15 pF
CL = 50 pF
• VCC = 2.5 ± 0.2 V
Item
Symbol
Ta = 25°C
Ta = –40 to 85°C
Min
Typ
Max
Min
Max
Propagation
t PLH
—
7.1
13.0
1.0
15.5
delay time
t PHL
—
9.2
16.5
1.0
18.5
Enable time
t ZH
—
7.4
13.0
1.0
15.5
t ZL
—
9.5
16.5
1.0
18.5
t HZ
—
5.7
14.7
1.0
17.0
t LZ
—
8.1
18.2
1.0
20.5
Disable time
Unit Test
ns
Conditions (Input)
(Output)
CL = 15 pF
A
Y
OE
Y
OE
Y
FROM
TO
CL = 50 pF
ns
CL = 15 pF
CL = 50 pF
ns
CL = 15 pF
CL = 50 pF
• VCC = 3.3 ± 0.3 V
Item
Symbol
Ta = 25°C
Ta = –40 to 85°C
Min
Typ
Max
Min
Max
Propagation
t PLH
—
5.0
8.0
1.0
9.5
delay time
t PHL
—
6.4
11.5
1.0
13.0
Enable time
t ZH
—
5.1
8.0
1.0
9.5
t ZL
—
6.6
11.5
1.0
13.0
t HZ
—
4.4
9.7
1.0
11.5
t LZ
—
6.1
13.2
1.0
15.0
Disable time
6
Unit Test
ns
Conditions (Input)
(Output)
CL = 15 pF
A
Y
OE
Y
OE
Y
CL = 50 pF
ns
CL = 15 pF
CL = 50 pF
ns
CL = 15 pF
CL = 50 pF
HD74LV2G126A
Switching Characteristics (cont)
• VCC = 5.0 ± 0.5 V
Item
Symbol
Ta = 25°C
Ta = –40 to 85°C
Min
Typ
Max
Min
Max
Propagation
t PLH
—
3.5
5.5
1.0
6.5
delay time
t PHL
—
4.6
7.5
1.0
8.5
Enable time
t ZH
—
3.6
5.1
1.0
6.0
t ZL
—
4.6
7.1
1.0
8.0
t HZ
—
3.3
6.8
1.0
8.0
t LZ
—
4.3
8.8
1.0
10.0
Disable time
Unit Test
ns
FROM
TO
Conditions (Input)
(Output)
CL = 15 pF
A
Y
OE
Y
OE
Y
CL = 50 pF
ns
CL = 15 pF
CL = 50 pF
ns
CL = 15 pF
CL = 50 pF
Operating Characteristics
• CL = 50 pF
Item
Power dissipation
capacitance
Symbol
CPD
VCC (V)
Ta = 25°C
Min
Typ
Max
3.3
—
10.5
—
5.0
—
11.5
—
Unit
Test Conditions
pF
f = 10 MHz
7
HD74LV2G126A
Test Circuit
VCC
Pulse Generator
Z OUT = 50 Ω
See Function Table
Input
VCC
Output
1k Ω S1
CL =
15 or 50 pF
TEST
t PLH / t PHL
t ZH/ t HZ
t ZL / t LZ
Note: 1. C L includes probe and jig capacitance.
8
OPEN
See under table
GND
*1
S1
OPEN
GND
VCC
HD74LV2G126A
• Waveforms – 1
tf
tr
90 %
50%
Input A
VCC
90 %
50%
10 %
10 %
GND
t PHL
t PLH
VOH
Output Y
50%
50%
VOL
• Waveforms – 2
tf
tr
90 %
50%
Input OE
VCC
90 %
50%
10 %
10 %
t LZ
t ZL
GND
VCC
50%
Waveform – A
t ZH
Waveform – B
VOL + 0.3 V
t HZ
50%
VOH – 0.3 V
VOL
VOH
GND
Notes: 1. tr ≤ 3 ns, tf ≤ 3 ns
2. Input waveform : PRR ≤ 1 MHz, duty cycle 50%
3. Waveform – A is for an output with internal conditions such that the output is low
except when disabled by the output control.
4. Waveform – B is for an output with internal conditions such that the output is high
except when disabled by the output control.
9
HD74LV2G126A
Package Dimensions
Unit : mm
(0.4)
1.50
0.5 0.5 0.5
+ 0.05
0.13 − 0.03
3.1 ± 0.1
(0.4)
2.3 ± 0.1
0 − 0.1
+ 0.05
8 − 0.2 − 0.04
0.7 ± 0.1
(0.17)
2.0 ± 0.1
10
Hitachi Code
JEDEC
EIAJ
Mass (reference value)
US-8
SSOP-8


HD74LV2G126A
Cautions
1. Hitachi neither warrants nor grants licenses of any rights of Hitachi’s or any third party’s patent,
copyright, trademark, or other intellectual property rights for information contained in this document.
Hitachi bears no responsibility for problems that may arise with third party’s rights, including
intellectual property rights, in connection with use of the information contained in this document.
2. Products and product specifications may be subject to change without notice. Confirm that you have
received the latest product standards or specifications before final design, purchase or use.
3. Hitachi makes every attempt to ensure that its products are of high quality and reliability. However,
contact Hitachi’s sales office before using the product in an application that demands especially high
quality and reliability or where its failure or malfunction may directly threaten human life or cause risk
of bodily injury, such as aerospace, aeronautics, nuclear power, combustion control, transportation,
traffic, safety equipment or medical equipment for life support.
4. Design your application so that the product is used within the ranges guaranteed by Hitachi particularly
for maximum rating, operating supply voltage range, heat radiation characteristics, installation
conditions and other characteristics. Hitachi bears no responsibility for failure or damage when used
beyond the guaranteed ranges. Even within the guaranteed ranges, consider normally foreseeable
failure rates or failure modes in semiconductor devices and employ systemic measures such as failsafes, so that the equipment incorporating Hitachi product does not cause bodily injury, fire or other
consequential damage due to operation of the Hitachi product.
5. This product is not designed to be radiation resistant.
6. No one is permitted to reproduce or duplicate, in any form, the whole or part of this document without
written approval from Hitachi.
7. Contact Hitachi’s sales office for any questions regarding this document or Hitachi semiconductor
products.
Hitachi, Ltd.
Semiconductor & Integrated Circuits.
Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan
Tel: Tokyo (03) 3270-2111 Fax: (03) 3270-5109
URL
NorthAmerica
Europe
Asia
Japan
:
:
:
:
http://semiconductor.hitachi.com/
http://www.hitachi-eu.com/hel/ecg
http://www.hitachi.com.sg/grp3/sicd
http://www.hitachi.co.jp/Sicd/indx.htm
For further information write to:
Hitachi Semiconductor
(America) Inc.
179 East Tasman Drive,
San Jose,CA 95134
Tel: <1> (408) 433-1990
Fax: <1>(408) 433-0223
Hitachi Europe GmbH
Electronic Components Group
Dornacher Stra§e 3
D-85622 Feldkirchen, Munich
Germany
Tel: <49> (89) 9 9180-0
Fax: <49> (89) 9 29 30 00
Hitachi Asia Ltd.
16 Collyer Quay #20-00
Hitachi Tower
Singapore 049318
Tel: 535-2100
Fax: 535-1533
Hitachi Europe Ltd.
Electronic Components Group.
Whitebrook Park
Lower Cookham Road
Maidenhead
Berkshire SL6 8YA, United Kingdom
Tel: <44> (1628) 585000
Fax: <44> (1628) 585160
Hitachi Asia Ltd.
Taipei Branch Office
3rd Flr, Hung Kuo Building, No.167,
Tun Hwa North Road, Taipei (105)
Taiwan
Tel: <886> (2) 2718-3666
Fax: <886> (2) 2718-8180
Telex: 23222 HAS-TP
Hitachi Asia (Hong Kong) Ltd.
Group III (Electronic Components)
7th Flr, North Tower, World Finance Centre,
Harbour City, Canton Road, Tsim Sha Tsui,
Kowloon, Hong Kong
Tel: <852> (2) 735 9218
Fax: <852> (2) 730 0281
Telex: 40815 HITEC HX
Copyright ' Hitachi, Ltd., 2000. All rights reserved. Printed in Japan.