HITRON HES100-31

H HiTRON
AUTO-RANGING INPUT AC TO DC EXTERNAL DESKTOP ADAPTER
MULTIPLE OUTPUT 100-120 WATTS SWITCHING POWER SUPPLIES
HES100 SERIES
FEATURES:
AUTO-RANGING ACCOMMODATE AC
SOURCES IN THE WORLD
IMPACT RESISTANT THERMO-PLASTIC
LOW-PROFILE ENCLOSURE
MEET UNIVERSAL SAFETY STANDARDS
CONDUCTED EMI MEET EN55022 / FCC
CLASS B, RADIATED EMI MEET CLASS A
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: Auto-ranging 115Vac for range 90-132Vac
and 230Vac for range 180-264Vac.
Transient threshold 150Vac typical.
Input Connector: IEC320 3P AC Inlet/Outlet receptacle,
with AC On/Off switch.
Input Frequency: 47-63Hz.
Inrush Current: 20A peak. @115Vac, 40A @230Vac.
Input Current: 2.5A @115Vac, 1.1A @ 230Vac.
Dielectric Withstand: Meet IEC950.
EMI: Conducted EMI meet EN55022 / FCC Class B.
Radiated EMI meet Class A,
Hold-up Time: 22mS @115Vac./ 27mS @230Vac.
Power Fail Signal: Option in all series.
Logic Inhibit: Optional in single & dual output series.
Remote Sensing: Optional for single & dual output series.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typ.100-120 Watts.
Output Connector & Cable: Optional.
Cord length typ. 3 ft.(1 meter).
Line Regulation: VO1, VO3 & VO4 ±0.1% typ.
Aux.VO2 ±0.5% typ.
Load Regulation: At strain relief end.
Main O/P VO1 ±1.0% typ.
Aux. O/P VO2 ±2.0% typ. with Mag. Amp. or
±5.0% typ. with Stacked on.
Aux. O/P VO3 & VO4 ±1.5% typ. with PR.
Noise & Ripple: Typ.1.0% peak to peak.
OVP: Main O/P only set @124% ±8% VO1.
Overload Protection: 125-150% of max. power
overrange or short circuit, power foldback
& self-recovering.
GENERAL SPECIFICATION
Efficiency: Typ. 75%.
Switching Frequency: Fixed Frequency at 100K Hz.
Circuit Topology: Fixed Frequency Forward circuit.
Transient Response: Output voltage returns in less than
3mS following a 25% load change.
Safety Standard: UL1950/EN60950 Class I.
Construction: Desktop enclosure plastic box.
Power Density: 0.88Watts / Cubic Inch.
Operating Temperature: 0 to +40°C.
Storage Temperature: -20 to +85°C.
Temperature Coefficient: 0.04% /°C.
Cooling: Built-in 6.5CFM 40mm fan cooling.
Long Term Stability: After 20 minutes warm-up,
0.1% for 8 hours.
Industrial or Commercial Grade Option:
" Industrial" higher MTBF, " Commercial" lower cost.
Note: (1) At least 20% of typical main output current is required to maintain stated regulation.
(2) Cord length typical 3 ft. (or 1 meter).
-41-
OUTPUT VOLTAGE/CURRENT RATINGS CHART
SINGLE OUTPUT
MODEL NO.
HES100-11
HES100-12
HES100-13
MAIN O/P VO1 ★#
Typ.
Peak
Volt.
8.3A
12.0V 10.0A
6.7A
8.0A
15.0V
4.2A
5.0A
24.0V
DUAL OUTPUT
MODEL NO.
HES100-21
HES100-22
HES100-23
HES100-24
HES100-25
MAIN O/P VO1
Typ.
Volt.
10.0A
5.0V
10.0A
5.0V
6.0A
5.0V
4.5A
12.0V
3.5A
15.0V
★◇
Max.
15.0A
15.0A
12.0A
5.0A
5.0A
AUX. O/P VO2 ▲◇
Typ.
Max.
Volt.
4.0A
3.5A
5.0V
3.0A
3.0A
12.0V
3.0A
3.0A
24.0V
4.5A
5.0A
12.0V
3.4A
4.0A
15.0V
TRIPLE OUTPUT
MODEL NO.
HES100-30
HES100-31
HES100-32
HES100-33
MAIN O/P VO1 ★
Typ.
Volt.
Max.
12.0A +5.0V 13.0A
12.0A +5.0V 13.0A
12.0A +5.0V 13.0A
12.0A +5.0V 13.0A
AUX. O/P VO2 †
Typ.
Volt.
Max.
3.0A +12.0V 3.5A
3.0A +12.0V 3.5A
1.5A +24.0V 2.0A
3.0A +15.0V 3.3A
AUX. O/P ±VO3 ●
Typ.
Max.
Volt.
0.8A
1.0A
12.0V
0.8A
1.0A
5.0V
0.8A
1.0A
12.0V
0.3A
1.0A
15.0V
QUAD OUTPUT
MODEL NO.
HES100-40
HES100-41
HES100-42
HES100-43
MAIN O/P VO1 ★
Typ. Volt. Max.
12.0A +5.0V 13.0A
12.0A +5.0V 13.0A
12.0A +5.0V 13.0A
12.0A +5.0V 13.0A
AUX. O/P VO2 †
Typ. Volt. Max.
2.5A +12.0V 3.0A
2.5A +12.0V 3.0A
1.0A +24.0V 1.5A
2.2A +15.0V 2.7A
AUX. O/P ± VO3 ●
Typ.
Volt. Max.
0.8A 12.0V 1.0A
0.8A
5.0V 1.0A
0.8A 12.0V 1.0A
0.6A 12.0V 1.0A
AUX. O/P ±VO4 ●
Typ.
Volt.
Max.
0.5A
12.0V 1.0A
0.6A
5.0V 1.0A
0.5A
12.0V 1.0A
0.4A
15.0V 1.0A
Symbols:" ★"OVP built-in. "@"Adjustable. "◇" Floating(or isolated) output. "●" Installed with Post Regulator (PR). "† "Stacked on main output.
"#" Remote sensing. "▲" Installed with magnetic amplifier. " ± " Positive or Negative selectable (factory set).
MECHANICAL DIMENSIONS: MM [INCHES]
-42-
WEIGHT: 1,242.0g (43.8 Oz.)