H HiTRON AUTO-RANGING INPUT AC TO DC EXTERNAL DESKTOP ADAPTER MULTIPLE OUTPUT 100-120 WATTS SWITCHING POWER SUPPLIES HES100 SERIES FEATURES: AUTO-RANGING ACCOMMODATE AC SOURCES IN THE WORLD IMPACT RESISTANT THERMO-PLASTIC LOW-PROFILE ENCLOSURE MEET UNIVERSAL SAFETY STANDARDS CONDUCTED EMI MEET EN55022 / FCC CLASS B, RADIATED EMI MEET CLASS A CE MARKING COMPLIANCE SPECIFICATION INPUT SPECIFICATION OUTPUT SPECIFICATION Input Voltage: Auto-ranging 115Vac for range 90-132Vac and 230Vac for range 180-264Vac. Transient threshold 150Vac typical. Input Connector: IEC320 3P AC Inlet/Outlet receptacle, with AC On/Off switch. Input Frequency: 47-63Hz. Inrush Current: 20A peak. @115Vac, 40A @230Vac. Input Current: 2.5A @115Vac, 1.1A @ 230Vac. Dielectric Withstand: Meet IEC950. EMI: Conducted EMI meet EN55022 / FCC Class B. Radiated EMI meet Class A, Hold-up Time: 22mS @115Vac./ 27mS @230Vac. Power Fail Signal: Option in all series. Logic Inhibit: Optional in single & dual output series. Remote Sensing: Optional for single & dual output series. Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Wattage: Typ.100-120 Watts. Output Connector & Cable: Optional. Cord length typ. 3 ft.(1 meter). Line Regulation: VO1, VO3 & VO4 ±0.1% typ. Aux.VO2 ±0.5% typ. Load Regulation: At strain relief end. Main O/P VO1 ±1.0% typ. Aux. O/P VO2 ±2.0% typ. with Mag. Amp. or ±5.0% typ. with Stacked on. Aux. O/P VO3 & VO4 ±1.5% typ. with PR. Noise & Ripple: Typ.1.0% peak to peak. OVP: Main O/P only set @124% ±8% VO1. Overload Protection: 125-150% of max. power overrange or short circuit, power foldback & self-recovering. GENERAL SPECIFICATION Efficiency: Typ. 75%. Switching Frequency: Fixed Frequency at 100K Hz. Circuit Topology: Fixed Frequency Forward circuit. Transient Response: Output voltage returns in less than 3mS following a 25% load change. Safety Standard: UL1950/EN60950 Class I. Construction: Desktop enclosure plastic box. Power Density: 0.88Watts / Cubic Inch. Operating Temperature: 0 to +40°C. Storage Temperature: -20 to +85°C. Temperature Coefficient: 0.04% /°C. Cooling: Built-in 6.5CFM 40mm fan cooling. Long Term Stability: After 20 minutes warm-up, 0.1% for 8 hours. Industrial or Commercial Grade Option: " Industrial" higher MTBF, " Commercial" lower cost. Note: (1) At least 20% of typical main output current is required to maintain stated regulation. (2) Cord length typical 3 ft. (or 1 meter). -41- OUTPUT VOLTAGE/CURRENT RATINGS CHART SINGLE OUTPUT MODEL NO. HES100-11 HES100-12 HES100-13 MAIN O/P VO1 ★# Typ. Peak Volt. 8.3A 12.0V 10.0A 6.7A 8.0A 15.0V 4.2A 5.0A 24.0V DUAL OUTPUT MODEL NO. HES100-21 HES100-22 HES100-23 HES100-24 HES100-25 MAIN O/P VO1 Typ. Volt. 10.0A 5.0V 10.0A 5.0V 6.0A 5.0V 4.5A 12.0V 3.5A 15.0V ★◇ Max. 15.0A 15.0A 12.0A 5.0A 5.0A AUX. O/P VO2 ▲◇ Typ. Max. Volt. 4.0A 3.5A 5.0V 3.0A 3.0A 12.0V 3.0A 3.0A 24.0V 4.5A 5.0A 12.0V 3.4A 4.0A 15.0V TRIPLE OUTPUT MODEL NO. HES100-30 HES100-31 HES100-32 HES100-33 MAIN O/P VO1 ★ Typ. Volt. Max. 12.0A +5.0V 13.0A 12.0A +5.0V 13.0A 12.0A +5.0V 13.0A 12.0A +5.0V 13.0A AUX. O/P VO2 † Typ. Volt. Max. 3.0A +12.0V 3.5A 3.0A +12.0V 3.5A 1.5A +24.0V 2.0A 3.0A +15.0V 3.3A AUX. O/P ±VO3 ● Typ. Max. Volt. 0.8A 1.0A 12.0V 0.8A 1.0A 5.0V 0.8A 1.0A 12.0V 0.3A 1.0A 15.0V QUAD OUTPUT MODEL NO. HES100-40 HES100-41 HES100-42 HES100-43 MAIN O/P VO1 ★ Typ. Volt. Max. 12.0A +5.0V 13.0A 12.0A +5.0V 13.0A 12.0A +5.0V 13.0A 12.0A +5.0V 13.0A AUX. O/P VO2 † Typ. Volt. Max. 2.5A +12.0V 3.0A 2.5A +12.0V 3.0A 1.0A +24.0V 1.5A 2.2A +15.0V 2.7A AUX. O/P ± VO3 ● Typ. Volt. Max. 0.8A 12.0V 1.0A 0.8A 5.0V 1.0A 0.8A 12.0V 1.0A 0.6A 12.0V 1.0A AUX. O/P ±VO4 ● Typ. Volt. Max. 0.5A 12.0V 1.0A 0.6A 5.0V 1.0A 0.5A 12.0V 1.0A 0.4A 15.0V 1.0A Symbols:" ★"OVP built-in. "@"Adjustable. "◇" Floating(or isolated) output. "●" Installed with Post Regulator (PR). "† "Stacked on main output. "#" Remote sensing. "▲" Installed with magnetic amplifier. " ± " Positive or Negative selectable (factory set). MECHANICAL DIMENSIONS: MM [INCHES] -42- WEIGHT: 1,242.0g (43.8 Oz.)