ETC HMJ8

HMJ8
The Communications Edge ™
High Dynamic Range FET Mixer
Product Features
• +37 dBm IIP3
• No External Matching Elements
•
•
•
•
•
•
Required
RF 2200-2300 MHz
LO 2060-2160 MHz
IF 50-150 MHz
+18 dBm Drive Level
+3V Bias (22 mA)
Low Cost Surface Mount J-Lead
Package
Functional Diagram
Product Description
The HMJ8 is a high dynamic range, GaAs FET
mixer. This active FET mixer realizes a typical
third order intercept point of +37 dBm at an
LO drive level of +18 dBm. The HMJ8 comes
in a low cost, J-lead package. Typical applications include frequency up/down conversion,
modulation and demodulation for receivers and
transmitters used in communication systems.
18 17 16 15 14 13 12 11 10
1 2 3 4 5 6 7 8 9
Function Pin No. Function Pin No.
Ground
1
Ground
10
IF
2
LO
11
Ground
3-7
Ground 12-16
+3V DC
8
RF
17
Ground
9
Ground
18
Specifications
Parameter
Frequency Range:
RF
LO
IF
SSB Conversion Loss
Noise Figure
Isolation:
LO-RF
LO-IF
RF-IF
IIP3
Return Loss:
RF Port
LO Port
IF Port
Input P1dB
LO Drive Level
DC Current at +3V Bias
Units
Minimum
MHz
MHz
MHz
dB
dB
2200
2060
50
dB
dB
dB
dBm
22
22
Typical
8
10.5
32
dB
dB
dB
dBm
dBm
mA
Maximum
Condition
2300
2160
150
9.0
27
30
15
37
11
8.5
14
23
18
22
35
Test conditions unless otherwise stated: RF = 2250 MHz (-10 dBm), LO = 2110 MHz (18 dBm), IF = 140 MHz and 25˚C.
Absolute Maximum Ratings
Parameter
Operating Case Temperature
Storage Temperature
Maximum Input Power
Ordering Information
Rating
-40 to +85°C
-65 to +100°C
25 dBm
Part No.
Description
HMJ8
High Dynamic Range FET Mixer
(Available in tape and reel)
Fully Assembled Application Circuit
HMJ8-PCB
1. Operation of this device above any of these parameters may cause permanent damage.
2. Total sum of LO port and RF port power should not exceed 25 dBm.
WJ Communications, Inc. • Phone: 1-800-WJ1-4401 • FAX: 408-433-5649 • e-mail: [email protected] • Web site: www.wj.com
September 2000
HMJ8
Performance Charts
IIP3 vs. RF Frequency
Conversion Loss vs. RF Frequency
40
7.2
IF = 100 MHz
IF = 150 MHz
Conversion Loss
IIP3 (dBm)
39
38
37
7.4
7.6
IF = 150 MHz
7.8
36
2230
2250
2270
2290
RF Frequency (MHz)
8.0
2190
2310
Isolation vs. LO Frequency
2230
2270
RF Frequency (MHz)
2310
Isolation vs. RF Frequency
40
25
35
Isolation (dB)
Isolation (dB)
L-R
30
L-I
25
20
15
20
2070
2100
2130
LO Frequency (MHz)
2160
10
2200
LO Return Loss (dB)
RF Return Loss (dBm)
10
15
20
2200
2220
2240
2260
RF Frequency (MHz)
2280
2300
2250
2275
RF Frequency (MHz)
2300
LO Return Loss vs. LO Frequency
RF Return Loss vs. RF Frequency
0
5
2225
IF Return Loss vs. IF Frequency
0
0
5
5
IF Return Loss (dB)
15
2040
10
15
20
2060
10
15
20
2080
2100
2120
LO Frequency (MHz)
2140
2160
50
70
90
110
IF Frequency (MHz)
WJ Communications, Inc. • Phone: 1-800-WJ1-4401 • FAX: 408-433-5649 • e-mail: [email protected] • Web site: www.wj.com
130
150
September 2000
HMJ8
Outline Drawing
Land Pattern
Specifications and information are subject to change without notice.
Mounting Configuration
Caution! ESD sensitive device.
WJ Communications, Inc. • Phone: 1-800-WJ1-4401 • FAX: 408-433-5649 • e-mail: [email protected] • Web site: www.wj.com
September 2000