MEANWELL HSG-70-18

HSG-70
70W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range(up to 305VAC)
Protections:Short circuit/Over load/Over voltage/Over temperature
Built-in active PFC function
High efficiency up to 90%
Cooling by free air convection
IP65 design for indoor and outdoor installations
Small and compact size
High reliability,low cost
Suitable for LED lighting and moving sign applications
3 years warranty
IP65
SPECIFICATION
HSG-70-12
MODEL
12V
DC VOLTAGE
CONSTANT CURRENT REGION Note.5 7.7 ~ 12V
5.0A
60W
RATED CURRENT
RATED POWER
RIPPLE & NOISE (max.) Note.2 150mVp-p
48V
15.5 ~ 24V
4.0A
72W
3.0A
72W
22.1 ~ 36V
2.0A
72W
1.5A
72W
1.2 ~ 2A
200mVp-p
200mVp-p
1.8 ~ 3A
200mVp-p
200mVp-p
29.3 ~ 48V
0.9 ~ 1.5A
2.0%
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
HOLD UP TIME
Note.7 2000ms,80ms / 115VAC 1000ms,80ms / 230VAC at full load
VOLTAGE RANGE
Note.4 90 ~ 305VAC
16ms at full load 230VAC/115VAC
127~431VDC
POWER FACTOR(Typ.)
47 ~ 63Hz
PF 0.96/115VAC, PF 0.96/230VAC,PF>0.92/277VAC at full load(please refer to "Power Factor characteristic curve")
EFFICIENCY(Typ.)
88%
AC CURRENT
INRUSH CURRENT(Typ.)
0.85A/115VAC 0.425A/230VAC
Cold start 70A/230VAC
Note.5
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
89%
89%
90%
<0.75mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
28 ~ 34V
14 ~ 17V
21 ~ 25V
Protection type : Shut down o/p voltage, re-power on to recover
54 ~ 63V
41 ~ 48V
100
10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +70
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
IP65 approved; design refer to TUV EN61347-1, EN61347-2-13, UL8750
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25 / 70%RH
Compliance to EN55015,EN61000-3-2 Class C( 65% load);EN61000-3-3
EMC IMMUNITY
MTBF
338.2Khrs min.
DIMENSION
90%
0.4A/277VAC
SAFETY STANDARDS
PACKING
NOTE
36V
11.3 ~ 18V
0.5%
SHORT CIRCUIT
OTHERS
18V
2.5%
OVER CURRENT
EMC
HSG-70-48
VOLTAGE TOLERANCE Note.3
LEAKAGE CURRENT
SAFETY &
HSG-70-36
24V
LINE REGULATION
FREQUENCY RANGE
INPUT
HSG-70-24
Can be adjusted by internal potentiometer
3 ~ 5A
2.4 ~ 4A
CURRENT ADJ. RANGE
OUTPUT
HSG-70-18
I/P-FG:1.88KVAC O/P-FG:0.5KVAC
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
MIL-HDBK-217F (25
)
127.2*90*38.8mm (L*W*H)
0.76Kg;16pcs/ 12.3Kg/0.57CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage, please check the static characteristics for more details.
5. Constant current operation region is within 65% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:HSG-70-SPEC 2012-03-07
HSG-70
70W Single Output Switching Power Supply
Mechanical Specification
Case No.209B
series
Unit:mm
127.2
112.5
103.2
100
V+(Brown)
V-(Blue)
4.5
300 10
20 1
Io ADJ.
2
23
2
15
H05RN-F 1.0mm 3C
T case
27.5
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
55
90
H05RN-F 1.5mm 2C
9.6
17.5
10
38.8
T case: Max. Case Temperature
IP65 rated. Constant current level can be adjusted through internal potentiometer.
(Can access by removing the rubber stopper on the case.)
Block Diagram
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
+V
-V
O.L.P.
O.T.P.
FG
O.L.P.
DETECTION
CIRCUIT
PWM & PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
230VAC
Input only
70
LOAD (%)
LOAD (%)
60
40
20
-40
-25
-10
0
15
30
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
305
INPUT VOLTAGE (V) 60Hz
File Name:HSG-70-SPEC 2012-03-07
HSG-70
70W Single Output Switching Power Supply
series
Power Factor Characteristic
Constant Current Mode
1
0. 98
PF
0. 96
0. 94
115VAC
0. 92
230VAC
0. 9
277VAC
0. 88
0. 86
0. 84
65%
70%
80%
LOAD
90%
100%
(70W)
EFFICIENCY vs LOAD (48V Model)
HSG-70 series possess superior working efficiency that up to 90% can be reached in field applications.
EFFICIENCY (%)
94
92
90
88
86
84
82
80
78
76
74
72
70
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
115VAC
230VAC
277VAC
LOAD
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method "direct drive" and "with LED driver".
A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
Vo(%)
100
(B)
Constant
Current area
(A)
Constant
Voltage area
65
(max.)
(C)
Hiccup
Protection
50
95
Io(%)
Typical LED power supply I-V curve
File Name:HSG-70-SPEC 2012-03-07