Component Distributors, Inc. ~ www.cdiweb.com ~ [email protected] ~ 1-800-777-7334 1U150 150W MICRO ATX PC Power with 1U Type series Features : AC input range selected by switch With +5VSB:0 ~ 1.5A max. Power good signal output Power fail signal output High efficiency Approvals: UL/ CUL/ CB /CE Forced air cooling by built-in DC fan 100% full load burn-in test Low cost 1 year warranty SPECIFICATION MODEL OUTPUT CH1 CH2 CH3 CH4 CH5 STANDBY DC VOLTAGE 3.3V 5V 12V -5V -12V 5VSB MINIMUM CURRENT 1.2A 2.4A 1.0A 0.1A 0.1A 0A MAXIMUM CURRENT 6.0A 12A 5.0A 0.5A 0.5A 1.5A RATED POWER (max.) 150W continue 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p RIPPLE & NOISE (max.) Note.2 50mVp-p LINE REGULATION LOAD REGULATION INPUT Note.3 5% 10% 10% 10% 4% 47~63Hz EFFICIENCY (Typ.) 70% AC CURRENT INRUSH CURRENT (max.) 5.0A / 115VAC POWER GOOD SIGNAL POWER FAIL SIGNAL 3.0A / 230VAC 40A / 115VAC 80A / 230VAC 3.5mA / 240VAC 105~150% rated output power Protection type : Shut down o/p voltage, re-power on to recover +5V, +12V: 110%~130% of rated voltage Protection type : Shut down o/p voltage, re-power on to recover All output equipped with short circuit Protection type : Shut down o/p voltage, re-power on to recover The TTL compatible signal out with 100ms to 500ms delay after power set up PS-ON INPUT SIGNAL The TTL compatible signal will go down at least 1ms before +5V below 4.7V Power on: PS-ON = "Low" or "<0.8V" ; Power off: PS-ON = "Hi" or ">2V" WORKING TEMP. -10~+35 SAFETY STANDARDS WITHSTAND VOLTAGE NOTE 1% 5% 90 ~ 132VAC/180 ~ 264VAC selected by switch WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION OTHERS 2% FREQUENCY RANGE SHORT CIRCUIT (Note 4) 2% VOLTAGE RANGE PROTECTION OVER VOLTAGE EMC 1% 16ms min. at full load OVER LOAD SAFETY & 1% HOLD UP TIME LEAKAGE CURRENT (max.) FUNCTION 1% 20~90% RH non-condensing -20~+85 , 10~95% RH 0.05% / (0~50 ) 10~200Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL1950 Approved I/P-O/P, I/P-FG:1.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG:100M Ohms / 500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) class B Compliance to EN61000-3-2,-3 HARMONIC CURRENT Compliance to EN61000-4-2,3,4,5,6,8,11, Light industry level, criteria A EMS IMMUNITY MTBF 100K hrs min. CONNECTOR ATX main power connector*1ea MIL-HDBK-217F (25 COOLING DIMENSION Forced air ventilation by 4cm DC fan 150*82*42.8mm (L*W*H) PACKING 0.6kg; 20pcs / 16kg / CARTON ) Peripheral power connector* 4ea Floppy drive power connector* 1ea 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Load regulation is measured from 20% to 100% max. Load. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:1U-150-SPEC 2004-06-21 Component Distributors, Inc. ~ www.cdiweb.com ~ [email protected] ~ 1-800-777-7334 Component Distributors, Inc. ~ www.cdiweb.com ~ [email protected] ~ 1-800-777-7334 1U150 150W MICRO ATX PC Power with 1U Type Mechanical Specification Unit:mm 6.0 6.0 26.0 42.8 M3 D=3mm AIR FLOW 38.0 150 32.5 3-M3 D=3mm 330 23.5 150 180 9.5 150 150 81 150 RED +5 RED +5 WHITE -5 BLACK GND BLACK GND BLACK GND GRAY PS-ON BLACK GND BLUE -12 ORANGE +3.3 YELLOW PURPLE GREEN BLACK RED BLACK RED BLACK ORANGE ORANGE 20P P4 YELLOW +12 BLACK GND RED +5 BLACK GND +12 5VSB PW-O GND +5 GND +5 GND +3.3 +3.3 POWER WIRE LENGTH 20P P4 180 930 File Name:1U-150-SPEC 2004-06-21 Component Distributors, Inc. ~ www.cdiweb.com ~ [email protected] ~ 1-800-777-7334