General Purpose Relays PCB Relays SCHRACK Power PCB Relay RT1 Inrush n1 pole 16A, 1 form C (CO) or 1 form A (NO) contact inrush peak currents up to 80A nMono- or bistable coil n5kV/10mm coil-contact nReinforced insulation nAmbient temperature 85°C nFor Typical applications Domestic appliances, heating control, lighting control F0177-C Zb Approvals Coil Data, DC coil VDE REG.-Nr. 6106, UL E214025, cCSAus 14385 Coil voltage range Operative range, IEC 61810 Coil insulation system according UL Technical data of approved types on request Contact Data Contact arrangement 1 form C (CO) or 1 form A (NO) Rated voltage 250VAC Max. switching voltage 400VAC Rated current 16A Limiting continuous current 16A, UL: 20A (K-version) Limiting making current, max. 4s, df 10% 30A max. 20ms (incandescent lamps), RT33L version80A Breaking capacity max. 4000VA Contact material AgNi90/10, AgSnO Frequency of operation, with/without load 360/72000h-1 Operate/release time max., DC coil 9/6ms Operate/Reset time max., bistable version 10/10ms Bounce time max., form A/form B 3/6ms Contact ratings Type Contact IEC 61810 RT33L A (NO) RT33K A (NO) UL 508 RT33K A (NO) RT33L A (NO) RT33L A (NO) RT33L A (NO) Load Cycles 16A, 250VAC resistive, 85°C 16A, 250VAC resistive, 85°C 50x103 30x103 5 to 110VDC 2 class F Coil versions, DC coil Coil Rated Operate Release Coil Rated coil codevoltagevoltagevoltage resistancepower VDCVDCVDC Ω±10%1)mW 0055 3.50.562403 0066 4.20.690400 01212 8.4 1.2360400 024 24 16.8 2.41440400 048 48 33.6 4.85520417 060 60 42.0 6.0 85701)420 1) Coil resistance ±12%. All figures are given for coil without pre-energization, at ambient temperature +23°C. Other coil voltages on request. 20A, 277VAC general purpose, 40°C 10x103 16A, 250VAC resistive, 85°C 50x103 1000W Tungsten, 120VAC, 60 Hz, 40°C 6x103 1000W standard ballast, 120VAC, 60 Hz, 40°C 6x103 Mechanical endurance monostable version bistable version >30x106 operations >5x106 operations Coil Data, bistable coils 1 coil 2 coils Magnetic system polarized, bistable Coil voltage range 5 to 24VDC Operative range, IEC 61810 2 Limiting voltage, % of rated coil voltage 120% 150% Min./Max. energization duration30ms/1min at <10% duty factor Coil insulation system according UL class F 03-2012, Rev. 0312 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 1 General Purpose Relays PCB Relays SCHRACK Power PCB Relay RT1 Inrush (Continued) Coil Data (continued) Insulation Data Coil versions, bistable coil Coil Rated Set Reset Coil Rated coil codevoltagevoltagevoltage resistancepower VDCVDCVDC Ω±10% mW bistable, 1 coil A055 3.52.862403 A066 4.23.390400 A1212 8.4 6.6360400 A24 24 16.813.21440400 bistable, 2 coils F05 5 3.52.842595 F06 6 4.23.355655 F12 12 8.4 6.6240600 F24 2416.813.2886650 All figures are given for coil without pre-energization, at ambient temperature +23°C. Other coil voltages on request. Bistable coils - operation Version 1 coil 2 coils Coil terminals A1 A2 A1 A3 A2 Operate + - + Reset - + - + Contact position not defined at delivery Initial dielectric strength between open contacts between contact and coil Clearance/creepage between contact and coil Material group of insulation parts Tracking index of relay base 1000Vrms 5000Vrms ≥10/10mm IIIa PTI 250V Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter Ambient temperature -40 to 85°C Category of environmental protection IEC 61810 RTII - flux proof Vibration resistance (functional), form A/form B contact, 30 to 500Hz 20/5g Shock resistance (destructive) 100g Terminal type PCB-THT, plug-in2) Weight14g Resistance to soldering heat THT IEC 60068-2-20 270°C/10s Packaging/unit tube/20 pcs., box/500 pcs. 2) socket available for 1 coil version only, see Accessories Accessories For details see datasheet Accessories Industrial Power Relay RT2) Socket available for 1 coil version only. NOTE: indicated contact ratings and electrical endurance data for direct wiring of relays (according IEC 61810-1); for relays mounted on sockets deratings may apply. Dimensions S0272-BC 2 03-2012, Rev. 0312 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. General Purpose Relays PCB Relays SCHRACK Power PCB Relay RT1 Inrush (Continued) PCB layout / terminal assignment Bottom view on solder pins 16A, 1 form C (CO) contact, pinning 5mm bistable version a) monostable version S0163-BE S0163-DI S0418-CM 16A, 1 form A (NO) contact, pinning 5mm a) Indicated contact position during or after coil energization with reset voltage. bistable version a) monostable version b) for 2 coil version only S0163-BF S0163DPS S0418-CV 12A, 1 form C (CO) contact, pinning 5mm monostable version, 1 form C (CO) monostable version, 1 form A (NO) S0163-BC *) With the recommended PCB hole sizes a grid pattern from 2.5mm to 2.54mm can be used. S0418-CN Product code structure RT 3 3 L012 Typical product code Type RT Power PCB Relay RT1 Inrush Version 3 16A, pinning 5mm, flux proof 2 12A, pinning 5mm, flux proof Contact configuration 1 1 form C (CO) contact 3 1 form A (NO) contact Contact material K AgNi 90/10 L AgSnO2 Coil Coil code: please refer to coil versions table Product code S0163-BD Version Contact material D 16A, pinning 5mm, sealed Coil version Coil Part number RT31L012 1 form C (CO) AgSnO2 Monostable 12VDC7-1393239-3 RT31L024 16A, pinning 5mm 24VDC 7-1393239-5 RT31L048 flux proof 48VDC 7-1393239-6 RT33K012 1 form A (NO) AgNi 90/10 12VDC 2-1393240-3 RT33K024 16A, pinning 5mm 24VDC 2-1393240-4 RT33KF12 flux proof Bistable 2 coils 12VDC 1-1415540-1 RT33L012 AgSnO2Monostable 3-1393240-3 RT33L024 24VDC 3-1393240-5 RT33LA12 Bistable 1 coil 12VDC 2-1393240-7 RT33LA24 24VDC 3-1415379-1 1 form C (CO) RTD1L012 16A, pinning 5mmAgSnO2 Monostable 12VDC 5-1393238-6 sealed 03-2012, Rev. 0312 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 3