ETC JAN2N7372

The documentation process conversion
measures necessary to comply with this
revision shall be completed by 28 March 1998
INCH-POUND
MIL-PRF-19500/612A
28 December 1997
SUPERSEDING
MIL-S-19500/612
30 July 1993
PERFORMANCE SPECIFICATION SHEET
SEMICONDUCTOR DEVICE, TRANSISTOR, PNP, SILICON, POWER,
TYPE 2N7372, JAN, JANTX, JANTXV, AND JANS
This specification is approved for use by all Departments and Agencies of the Department of Defense.
1. SCOPE
1.1 Scope. This specification covers the performance requirements for PNP, silicon, power transistors for use in high-speed power
switching applications. Four levels of product assurance are provided as specified in MIL-PRF-19500.
1.2 Physical dimensions. See figure 1 (TO-254AA).
1.3 Maximum ratings.
Type
2N7372
PT 1/
PT 2/
TA = +25qC
TC = +25qC
W
W
V dc
V dc
V dc
4
58
100
80
5.5
VCBO
VCEO
VEBO
Safe
operating
area
TJ and TSTG
3/
Reverse
pulse 4/
energy
A dc
A dc
mJ
See
figure 4
qC
5.0
10
15
IC
IC
-65 to +200
1/ Derate linearly 22.8 mW/qC for TA > +25qC.
2/ Derate linearly 331 mW/qC for TC > +25qC.
3/ This value applies for PW d 8.3 ms, duty cycle d 1 percent.
4/ This rating is based on the capability of the transistors to operate safely in the unclamped inductive load energy test circuit of
figure 1.
1.4 Primary electrical characteristics.
hFE2
|hfe|
VBE(SAT)2 1/
VCE(SAT)2 1/
Cobo
VCE = 5.0 V dc
IC = 2.5 A dc
VCE = 5.0 V dc
IC = 500 mA dc
f = 10 MHz
IC = 5.0 A dc
IB = 500 mA dc
IC = 5.0 A dc
IB = 500 mA dc
VCB = 10 V dc
IE = 0 A dc
f = 1 MHz
V dc
V dc
2.2
1.5
Min
70
Max
200
1/ Pulse (see 4.5.1)
7.0
RTJA
RTJC
pF
qC/W
qC/W
250
40
3
Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document
should be addressed to: Commander, Defense Supply Center Columbus, ATTN: DSCC-VAT, 3990 East Broad Street, Columbus, OH
43216-5000, by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or
by letter.
AMSC N/A
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
FSC 5961
MIL-PRF-19500/612A
2. APPLICABLE DOCUMENTS
2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include
documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has
been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements
documents cited in sections 3 and 4 of this specification, whether or not they are listed.
2.2 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document
to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department
of Defense Index of Specifications and Standards (DODISS) and supplement thereto, cited in the solicitation (see 6.2).
SPECIFICATION
DEPARTMENT OF DEFENSE
MIL-PRF-19500 - Semiconductor Devices, General Specification for.
STANDARD
MILITARY
MIL-STD-750 - Test Methods for Semiconductor Devices.
(Unless otherwise indicated, copies of the above specifications, standards, and handbooks are available from the Standardization
Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.3 Order of precedence. In the event of a conflict between the text of this document and the references cited herein (except for
related associated specifications or specification sheets), the text of this document takes precedence. Nothing in this document,
however, supersedes applicable laws and regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 Qualification. Devices furnished under this specification shall be products that are authorized by the qualifying activity for listing
on the applicable qualified products list before contract award (see 4.2 and 6.3).
3.2 Associated specification. The individual item requirements shall be in accordance with MIL-PRF-19500 and as specified herein.
3.3 Abbreviations, symbols, and definitions. Abbreviations, symbols, and definitions used herein shall be as specified in
MIL-PRF-19500.
3.4 Interface requirements and physical dimensions. The interface requirements and physical dimensions shall be as specified on
figure 1. Methods used for electrical isolation of the terminal feedthroughs shall employ materials that contain a minimum of 90 percent
AL2O3 (ceramic). Examples of such construction techniques are metallized ceramic eyelets or ceramic walled packages. The preferred
measurements used herein are the metric units. However, this transistor was designed using inch-pound units of measurement. In case
of conflicts between the metric and inch-pound units, the inch-pound units shall be ruled.
3.4.1 Lead finish and formation. Lead finish shall be solderable in accordance with MIL-STD-750, MIL-PRF-19500, and herein.
Where a choice of lead finish or formation is desired, it shall be specified in the acquisition requirements (see 6.5). When lead formation
is performed, as a minimum, the vendor shall perform 100 percent hermetic seal in accordance with appendix E, table IV, screen 14, of
MIL-PRF-19500.
3.5 Marking. Marking shall be in accordance with MIL-PRF-19500.
3.6 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are as
specified in 1.3, 1.4, and table I herein.
3.7 Electrical test requirements. The electrical test requirements shall be the subgroups specified in 4.4.2 and 4.4.3 herein.
2
MIL-PRF-19500/612A
Dimensions
Ltr
Inches
Millimeters
Min
Max
Min
Max
BL
.535
.545
13.59
13.89
CH
.249
.260
6.32
6.60
LD
.035
.045
0.89
1.43
LL
.53
.55
13.46
13.97
LO
.150 BSC
3.81 BSC
LS
.150 BSC
3.81 BSC
MHD
.139
.149
3.53
3.78
MHO
.665
.685
16.89
17.40
TL
.790
.800
20.07
20.32
TT
.040
.050
1.02
1.27
TW
.535
.545
13.59
13.89
Term 1
Base
Term 2
Collector
Term 3
Emitter
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. All terminals are isolated from case.
FIGURE 1. Dimensions and configuration (T0-254AA).
3
MIL-PRF-19500/612A
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are classified as follows:
a.
Qualification inspection (see 4.2).
b.
Screening (see 4.3)
c.
Conformance inspection (see 4.4).
4.2 Qualification inspection. Qualification inspection shall be in accordance with MIL-PRF-19500.
4.3 Screening ( JANS, JANTX, and JANTXV levels only). Screening shall be in accordance with MIL-PRF-19500 (Appendix E, table
IV), and as specified herein. The following measurements shall be made in accordance with table I herein. Devices that exceed the limits
of table I herein shall not be acceptable.
Screen (see
appendix E,
table IV of
MIL-PRF-19500)
Measurement
JANS level
JANTX and JANTXV levels
1/
Thermal impedance (see 4.3.2)
Thermal impedance (see 4.3.2)
9
ICES1 and hFE2
Not applicable
11
Subgroup 2 of table I herein;
ICES1 and hFE2; 'ICES1 = 100
percent of initial value or 100 nA dc
whichever is greater. 'hFE2
= r 20 percent of initial value.
ICES1 and hFE2
12
t = 160 hours
t = 80 hours minimum
13
Subgroups 2 and 3 of table I herein;
ICES1 and hFE2;
'ICES1 = 100 percent of initial value
or 100 nA dc, whichever is greater.
'hFE2 = r 20 percent of initial value.
Subgroup 2 of table I herein;
ICES1 and hFE2;
'ICES1 = 100 percent of initial value
or 100 nA dc, whichever is greater.
'hFE2 = r 20 percent of initial value.
1/ May be performed anytime before screen 9.
4.3.1 Power burn-in conditions. Power burn-in conditions are as follows:
TJ = 187.5 r 12.5qC, VCE t 20 V dc, TA d 100qC
4.3.2 Thermal impedance (ZTJX measurements). The ZTJX measurements shall be performed in accordance with
MIL-STD-750, method 3131. The maximum limit (not to exceed the group A, subgroup 2 limit) for ZTJX in appendix E, table IV,
screening of MIL-PRF-19500 shall be derived by each vendor by means of statistical process control. When the process has exhibited
control and capability, the capability data shall be used to establish the fixed screening limit. In addition to screening, once a fixed limit
has been established, monitor all future sealing lots using a random five piece sample from each lot to be plotted on the applicable X, R
chart. If a lot exhibits an out of control condition, the entire lot shall be removed from the line and held for Engineering evaluation and
disposition.
4
MIL-PRF-19500/612A
4.3.2.1 Thermal impedance (ZTJX ) for measurements initial qualification or requalification. The ZTJX measurements shall be
performed in accordance with MIL-STD-750, method 3131 (read and record date ZTJX). ZTJX shall be supplied on one lot (500 devices
minimum and a thermal response curve shall be submitted). Twenty two of these samples shall be serialized and provided to the
qualifying activity for correlation prior to shipment of parts. Measurements conditions shall be in accordance with 4.4.1.
4.4 Conformance inspection. Conformance inspection shall be in accordance with MIL-PRF-19500, and as specified herein.
4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with appendix E, table V of MIL-PRF-19500, and
table I herein. The following test conditions shall be used for ZTJX, end point measurements: ZTJX = 3.1qC/W.
a.
IM ........................................................................... 10 mA.
b.
VCE measurement voltage ..................................... 20 V (same as VH).
c.
IH collector heating current .................................... 1 A (minimum).
d.
VH collector-emitter heating voltage ...................... 20 V (minimum).
e.
tH heating time ....................................................... 100 ms.
f.
tMD measurement delay time ................................. 50 Ps to 80 Ps.
g.
tSW sample window time ....................................... 10 Ps (maximum).
4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the conditions specified for subgroup testing in
appendix E, tables VIa (JANS) and VIb (JANTX and JANTXV) of MIL-PRF-19500. Electrical measurements (end points) shall be in
accordance with the applicable steps and table I, group A, subgroup 2 herein except ZTJX shall be performed after Intermittent Life
(subgroup 4) only.
4.4.2.1 Group B inspection, appendix E, table VIa (JANS) of MIL-PRF-19500.
Subgroup
Method
Condition
B3
2037
Test condition A.
B4
1037
VCB = 10 V dc minimum; PT = 2.5 W at TA = room ambient as defined in the general
requirements of 4.5 of MIL-STD-750; ton = toff = 3 minutes minimum for 2,000 cycles. No heat
sink or forced air cooling on the devices shall be permitted.
B5
1027
See 4.5.4.
B6
3131
See 4.5.2.
4.4.2.2 Group B inspection, appendix E, table VIb (JANTX and JANTXV) of MIL-PRF-19500.
Subgroup
B3
Method
1037
Condition
VCB = 10 V dc minimum; PT = 2.5 W at TA = room ambient as defined in the general
requirements of 4.5 of MIL-STD-750; ton = toff = 3 minutes minimum for 2,000 cycles. No heat
sink or forced air cooling on the devices shall be permitted.
B5
3131
See 4.5.2.
4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the conditions specified for subgroup testing in
appendix E, table VII of MIL-PRF-19500. Electrical measurements (end points) shall be in accordance with the applicable steps and
table I, group A, subgroup 2 herein except ZTJX shall be performed after Intermittent Life (subgroup 4) only.
5
MIL-PRF-19500/612A
4.4.3.1 Group C inspection, appendix E, table VII of MIL-PRF-19500.
Subgroup
Method
Condition
C2
2036
Tense: test condition A; weight 10 pounds r 5 ounces; time 15 seconds.
Bend strength: test condition F; bending stress 2 pounds, time 15 seconds.
C6
1037
VCB = 30 V dc minimum; PT = 2.5 W at TA = room ambient as defined in the general
requirements of (see 4.5) of MIL-STD-750; ton = toff = 3 minutes minimum for 6,000 cycles. No
heat sink or forced air cooling on the devices shall be permitted.
4.4.4 Group E inspection. Group e inspection shall be conducted in accordance with the conditions specified for subgroup testing in
appendix E, table IX of MIL-PRF-19500. Electrical measurements (end points) shall be in accordance with the applicable steps and table
I, group A, subgroup 2 herein except ZTJX shall not be performed.
4.4.4.1 Group E inspection, appendix E, table IX of MIL-PRF-19500.
Subgroup
Method
Condition
Sampling plan
E1
1051
500 cycles
22 devices, c = 0
E2
1039
Condition A, 500 hours
22 devices, c = 0
E3
E4
Not applicable
3131
See 4.4.1
10 devices, c = 0
4.5 Method of inspection. Methods of inspection shall be as specified in the appropriate tables and as follows:
4.5.1 Pulse measurements. Conditions for pulse measurement shall be as specified in section 4 of MIL-STD-750.
4.5.2 Thermal resistance. Thermal resistance measurements shall be conducted in accordance with test method 3131 of
MIL-STD-750. The following details shall apply:
a.
Collector current magnitude during power application shall be 2 A dc.
b.
Collector to emitter voltage magnitude shall be 10 V dc.
c.
Reference temperature measuring point shall be the case.
d.
Reference point temperature shall be 25qC d TR d 75qC and recorded before the test is started.
e.
Mounting arrangement shall be with heat sink to header.
f.
Maximum limit of RTJC shall be 3.0qC/W.
4.5.3 Inspection conditions. Unless otherwise specified in MIL-PRF-19500 or herein, all inspections shall be conducted at a case
temperature (TC) of +25qC r 3qC.
4.5.4 Group B accelerated life test. This test shall be conducted using one of the two options listed herein (a and b) with the following
conditions applying to all options: VCB = 20 V minimum dc; TJ = +275qC.
a. PT = 2.5; PT adjusted to give a lot average of TJ = +275qC with TA = +125qC r 25qC.
b. TA = +25qC r 3qC with PT adjusted to give a lot average of TJ = +275qC.
6
MIL-PRF-19500/612A
TABLE I. Group A inspection.
Inspection 1/
MIL-STD-750
Method
Symbol
Conditions
Limits
Min
Unit
Max
Subgroup 1
Visual and mechanical
examination
2071
Subgroup 2
3.1
qC/W
V(BR)CEO
80
V dc
Bias condition C;
VCE = 60 V dc; VBE = 0
ICES1
1.0
PA dc
Bias condition C;
VCE = 100 V dc; VBE = 0
ICES2
1.0
mA dc
3041
Collector to emitter
cutoff current
3041
Bias condition D;
VCE = 40 V dc; I = 0
B
ICEO
50
PA dc
Emitter to base
cutoff current
3061
IEBO1
1.0
PA dc
Emitter to base
cutoff current
3061
IEBO2
1.0
mA dc
3076
VCE = 5.0 V dc;
IC = 50 mA dc; pulsed (see 4.5.1)
hFE1
50
Forward-current
transfer ratio
3076
VCE = 5.0 V dc; IC = 2.5 A dc;
pulsed (see 4.5.1)
hFE2
70
Forward-current
transfer ratio
Forward-current
transfer ratio
3076
VCE = 5.0 V dc; IC = 5.0 A dc;
pulsed (see 4.5.1)
hFE3
Base to emitter
non-saturated voltage
3066
Test condition B; VCE = 5.0 V dc
IC = 2.5 A dc Pulsed (see 4.5.1)
VBE
1.45
V dc
Base to emitter
saturated voltage
3066
VBE(SAT)1
1.45
V dc
Thermal impedance
3131
See 4.4.1
Collector to emitter
breakdown voltage
3011
Bias condition D; IC = 100 mA dc;
IB = 0; Pulsed (see. 4.5.1)
Collector to emitter
cutoff current
3041
Collector to emitter
cutoff current
Bias condition D;
VEB = 4 dc; I = 0
C
Bias condition D;
VEB = 5.5 dc; I = 0
C
Test condition A; IC = 2.5 A dc
IB = 250 mA dc Pulsed (see 4.5.1)
See footnote at end of table.
7
40
MIL-PRF-19500/612A
TABLE I. Group A inspection - Continued.
Inspection 1/
MIL-STD-750
Method
Symbol
Conditions
Limits
Min
Unit
Max
Subgroup 2 - Continued
Base to emitter
saturated voltage
3066
Test condition A; IC = 5.0 A dc
IB = 500 mA dc Pulsed (see 4.5.1)
Collector to emitter
saturated voltage
3071
Collector to emitter
saturated voltage
3071
VBE(SAT)2
2.2
V dc
IC = 2.5 A dc; IB = 250 mA dc;
pulsed (see 4.5.1)
VCE(sat)1
0.75
V dc
IC = 5.0 A dc; IB = 500 mA dc;
pulsed (see 4.5.1)
VCE(sat)2
1.5
V dc
500
PA dc
Subgroup 3
TA = +150qC
High-temperature
operation:
Collector to emitter
cutoff current
3041
Low-temperature
operation:
Forward-current
transfer ratio
Bias condition A; VCE = 60 V dc
VBE(OFF) = +2 V dc
ICEX
TA = -55qC
3076
VCE = 5.0 V dc; IC = 2.5 A dc;
IC = 2.5 A dc
hFE4
25
Subgroup 4
Common-emitter, smallsignal short-circuit
forward-current
transfer ratio
3206
VCE = 5 V dc; IC = 100 mA dc;
f = 1 kHz
hfe
50
Magnitude of common
emitter small-signal
short-circuit forwardcurrent transfer ratio
3206
VCE = 5 V dc; IC = 500 mA dc;
f = 10 MHz
|hfe|
7
Open circuit output
capacitance
3236
VCB = 10 V dc; IE = 0;
100 kHz d f d 1 MHz
Cobo
250
pF
IC = 5 A dc; IB1 = 500 mA dc
ton
0.5
Ps
IB2 = -500 mA dc
ts
1.4
Ps
0.5
Ps
1.5
Ps
Switching time
VBE(off) = 3.7 V dc
tf
RL = 6 S; (see figure 2)
toff
See footnote at end of table.
8
MIL-PRF-19500/612A
TABLE I. Group A inspection - Continued.
Inspection 1/
MIL-STD-750
Method
Symbol
Conditions
Min
Subgroup 5
Safe operating area
(continuous dc)
3055
Pre pulse condition for each test:
VCE = 0, IC = 0 TC = +25qC
Pulse condition for each test:
tp = 1 second, 1 cycle
TC = +25qC (see figure 4)
Test 1
VCE = 12 V dc, IC = 5 A dc
Test 2
VCE = 32 V dc, IC = 1.5 A dc
Test 3
VCE = 80 V dc, IC = 100 mA dc
Safe operating area
(unclamped inductive)
Electrical measurements
3053
Limits
TC = +25qC; RBB1 = 10 ohms;
RBB2 = 100 ohms; L = 0.3 mH
RL = 0.1 ohms; VCC = 10 V dc
VBB1 = 10 V dc; VBB2 = 4 V dc
ICM = 10 A dc (see figure 3)
Table I, group A, subgroup 2
Subgroups 6 and 7
Not applicable.
1/ For sampling plan, see MIL-PRF 19500.
9
Unit
Max
MIL-PRF-19500/612A
NOTES:
1.
Vgen is -30 pulse (from 0 V) into a 50 ohm termination.
2.
The Vgen waveform is supplied by a generator with the following characteristics: tr d 15 ns, tf = 15 ns, ZOUT = 50 ohm, duty
cycle d 2 percent.
3.
4.
5.
Waveforms are monitored on an oscilloscope with the following characteristics: tr d 15 ns, RIN t 10 M:, CIN d 11.5 pF.
Resistors shall be noninductive types.
The dc power supplies may require additional bypassing in order to minimize ringing.
FIGURE 2. Switching time test circuit.
10
MIL-PRF-19500/612A
FIGURE 3. Unclamped inductive load energy test circuit.
11
MIL-PRF-19500/612A
FIGURE 4. Maximum safe operating area.
12
MIL-PRF-19500/612A
5. PACKAGING
5.1 Packaging. Packaging shall prevent mechanical damage of the devices during shipping and handling and shall not be detrimental
to the device. When actual packaging of material is to be performed by DoD personnel, these personnel need to contact the responsible
packaging activity to ascertain requisite packaging requirements. Packaging requirements are maintained by the Inventory Control Points'
packaging activity within the Military Department or Defense Agency, or within the Military Departments' System Command. Packaging
data retrieval is available from the managing Military Departments' or Defense Agency's automated packaging files, CD-ROM products, or
by contacting the responsible packaging activity.
5.2 Marking. Unless otherwise specified (see 6.2), marking shall be in accordance with MIL-STD-129.
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.)
6.1 Notes. The notes specified in MIL-PRF-19500 are applicable to this specification.
6.2 Acquisition requirements. See MIL- PRF-19500.
6.3 Qualification. With respect to products requiring qualification, awards will be made only for products which are, at the time of
award of contract, qualified for inclusion in Qualified Products List QPL No.19500 whether or not such products have actually been so
listed by that date. The attention of the contractors is called to these requirements, and manufacturers are urged to arrange to have the
products that they propose to offer to the Federal Government tested for qualification in order that they may be eligible to be awarded
contracts or purchase orders for the products covered by this specification. Information pertaining to qualification of products may be
obtained from Defense Supply Center Columbus, ATTN: DSCC-VQE, 3990 East Broad Street, Columbus, OH 43216-5000.
6.4 Interchangeability information. MIL-PRF-19500/612 is a T0-254 package version of MIL-PRF-19500/535, which is a T0-210 (T059) package version. The military 2N7372 contains the same die as the military 2N5005. The MIL-PRF-19500/612 is preferred over the
MIL-PRF-19500/535 whenever interchangeability is not a problem. For new design use 2N7372. The 2N5005 is inactive for new design.
6.5 Ordering data. Acquisition documents may specify the material and finish.
6.6 Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous
issue due to the extent of the changes.
Custodians:
Army - CR
Navy - EC
Air Force - 17
NASA - NA
Preparing activity:
DLA - CC
(Project 5961-1902-08)
Review activities:
Army - AR, MI, SM
Navy - AS, CG, MC
Air Force - 13, 19, 85, 99
13
STANDARDIZATION DOCUMENT IMPROVEMENT PROPOSAL
INSTRUCTIONS
1. The preparing activity must complete blocks 1, 2, 3, and 8. In block 1, both the document number and revision
letter should be given.
2. The submitter of this form must complete blocks 4, 5, 6, and 7.
3. The preparing activity must provide a reply within 30 days from receipt of the form.
NOTE: This form may not be used to request copies of documents, nor to request waivers, or clarification of
requirements on current contracts. Comments submitted on this form do not constitute or imply authorization to
waive any portion of the referenced document(s) or to amend contractual requirements.
I RECOMMEND A CHANGE:
1. DOCUMENT NUMBER
MIL-PRF-19500/612A
2. DOCUMENT DATE 971228
3. DOCUMENT TITLE
SEMICONDUCTOR DEVICE, TRANSISTOR, PNP, SILICON, POWER TYPES 2N7372 JAN, JANTX, JANTXV, AND JANS
4. NATURE OF CHANGE (Identify paragraph number and include proposed rewrite, if possible. Attach extra sheets as needed.)
5. REASON FOR RECOMMENDATION
6. SUBMITTER
a. NAME (Last, First, Middle initial)
c. ADDRESS (Include Zip Code)
b. ORGANIZATION
d. TELEPHONE (Include Area Code)
Commercial
DSN
FAX
EMAIL
7. DATE SUBMITTED
(YYMMDD)
8. PREPARING ACTIVITY
a. Point of contact Alan Barone
c. ADDRESS
Defense Supply Center Columbus, ATTN:
DSCC-VAT, 3990 East Broad Street, Columbus,
OH 43216-5000
DD Form 1426, OCT 89
b. TELEPHONE
Commercial
DSN
614-692-0510
850-0510
FAX
614-692-6939
EMAIL
[email protected]
IF YOU DO NOT RECEIVE A REPLY WITHIN 45 DAYS, CONTACT:
Defense Quality and Standardization Office
5203 Leesburg Pike, Suite 1403, Falls Church, VA 22041-3466
Telephone (703) 756-2340 AUTOVON 289-2340
Previous editions are obsolete
198/290