JGC-4F SOLID STATE RELAY Features File No.: E133481 • DC input-AC output for 2A load at 25 Volt blocking voltage • Photo isolation • Built-in snubber • Zero cross or random turn-on • Printed circuit board mount • 600 File No.: R2024431 File No.: CH0032705-2002A INPUT (TA = 25•C) Control voltage range Must operate voltage DESCRIPTION 05D 4 to 6VDC This SPST-NO printed circuit board mount SIP SSR provides AC output 12D 9.6 to 14.4VDC switching in a high density package.The JGC-4F's DC input is compatible 24D 19.2 to 28.8VDC with 5, 12 and 24V logic systems .All models include an internal 05D 4VDC max. 12D 9.6VDC max. 24D 19.2VDC max. 1.0VDC min. Must release voltage 10mA Max. input current snubber.The relays provide 2000Vrms opto-isolation,between input and output. Encapsulation,thermally conductive epoxy. PRECAUTIONS 1. Terminal arrangement 1 Load voltage range (@47 to 63Hz) 75 to 264VAC Load current range 0.1 to 2A 25Apk Max. leakage current 1.5mA Max. on-state voltage drop Max. turn-on time 1.5VAC Zero cross turn-on 10ms Random turn-on 1ms Max. turn-off time 10ms AC line 0 180 2 input Max. surge current (10ms) load output OUTPUT Pulse width Input signal 3(+) Input signal turn off Minimum 200µs 4(-) 2. Soldering must be completed within 10 seconds at 260 or within 5 seconds at 350 or less or less. 3. The SSR case serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the Solid State Relays JGC-4F Transient overvoltage 600Vpk max. Min. off-state dv/dt 100V/µs min. 4. The input circuitry does not incorporate a circuit protecting the SSR 15V max. from being damaged due to a reversed connection. Make sure that the Zero-crossover voltage Min. power factor 0.5 load current by half. polarity is correct when connecting the input lines. 5. When using the JGC-4F series for an AC load with a peak voltage of more than 450V,connect the load terminals of the relay to an inrush GENERAL absorber(varistor). The recommended varistor voltage, 440 to 470V. Dielectric strength ( input to output ) 2000VAC min., 50/60Hz 1min. Insulation resistance 1000M , min. (at 500VDC) Max. Capacitance ( input to output ) Vibration durability 5pF 10 to 55HZ Double amplitude 1.5mm Shock durability Operating Ambient temperature Storage Ambient Humidity 1000m/s2 -30 -30 to +80 to +100 45% to 85% Unit weight 6g HONGFA RELAY ISO9001/QS9000/ISO14000 CERTIFIED 176 6. The load terminals are internally connected to a snubber circuit that absorb noise. However, if wiring from these terminals is laid with or placed in the same duct as high-voltage or power lines, noise may be induced, causing the SSR to operate irregularly or malfunction. 7. When using the JGC-4F series in phase control applications, at a phase control angle close to 180 degrees the relay's input signal turn off at the trailing edge of the AC sine wave must be limited to end 200µs before AC zero cross. This assures that the relay has time to switch off. Shorter times may cause loss of control at the following half cycle. ORDERING INFORMATION JGC-4F / 12 D 1 T Type Input voltage Input Form 05 : 4 to 6VDC 12 : 9.6 to 14.4VDC 24 : 19.2 to 28.8VDC D: DC Zero Cross Function 0: Zero cross turn-on 1: Randm turn-on Termination T: Same as TOSHIBA TSZXX48S, M: Same as OMRON G3MB OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT Outline Dimensions 24 max. PCB layout Wiring Diagram 6.5max. 1 0.7 0.15 0.4 0.15 3.9 0.5 (2.5) (+)3 4(_) input load 4-Ø1 2.54 5.08 0.5 2 2.54 20max JGC-4F/ D- T 2.54 0.3 (Bottom view) 1.7 0.3 7.62 0.6 24 max. 6.5max. 1 20max. JGC-4F/ D- M 4-Ø1 Solid State Relays JGC-4F 0.4 0.15 3.9 0.5 (2.5) 2.54 0.3 7.62 0.6 input load 2.54 0.7 0.15 (+)3 4(_) 2 2.54 1.7 0.3 10.16 0.6 CHARACTERISTICS CURVE MAXIMUM LOAD CURRENT VS.AMBIENT TEMPERATURE MAXIMUM PERMISSIBLE NON-REPETITIVE PEAK SURGE CURRENT VS. CONTINUANCE TIME PULSE INPUT CURRENT VS. PULSE WIDTH INPUT CURRENT VS. AMBIENT TEMPERATURE 1.6 Peak Surge Current(%) 2.5 25 IT 1000 1.0 0.5 0 -30 -20 0 20 25 40 60 Ambient Temperature( 80 ) 100 600 20 NORMALIZED TO: TA=25•C tw Iin(tw)/Iin 1.5 1.4 0 Tj=25•C F=50Hz 800 Iin(tw)/Iin Load Current(A) 2.0 Normalized to: tw•100µs 15 10 1.2 1.0 400 0 10 0.8 5 200 0 100 1000 Energizing Continuance Time(ms) 10000 1 2 5 10 20 Pulse Width Tw (µS) 50 100 0.6 -40 -20 0 20 40 60 Ambient Temperature( 80 ) 177