KS8995MA/FQ Integrated 5-Port 10/100 Managed Switch Rev. 3.0 General Description The KS8995MA/FQ is a highly-integrated Layer 2 managed switch with optimized bill of materials (BOM) cost for low port count, cost-sensitive 10/100Mbps switch systems with both copper and optic fiber media. It also provides an extensive feature set such as tag/portbased VLAN, quality of service (QoS) priority, management, MIB counters, dual MII interfaces and CPU control/data interfaces to effectively address both current and emerging fast Ethernet applications. The KS8995MA/FQ contains five 10/100 transceivers with patented mixed-signal low-power technology, five media access control (MAC) units, a high-speed non-blocking switch fabric, a dedicated address lookup engine, and an on-chip frame buffer memory. All PHY units support 10BASE-T and 100BASE-TX. In addition, two of the PHY units support 100BASE-FX on ports 4 and 5 for KSZ8995MA, two of the PHY units support 100BASE-FX on ports 3 and 4 for KSZ8995FQ. Datasheets and support documentation can be found on Micrel’s web site at: www.micrel.com. Functional Diagram Micrel Inc. • 2180 Fortune Drive • San Jose, CA 95131 • USA • tel +1 (408) 944-0800 • fax + 1 (408) 474-1000 • http://www.micrel.com October 2011 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Features • Integrated switch with five MACs and five fast Ethernet transceivers fully-compliant to IEEE 802.3u standard • Shared memory based switch fabric with fully nonblocking configuration • 1.4Gbps high-performance memory bandwidth • 10BASE-T, 100BASE-TX, and 100BASE-FX modes • Dual MII configuration: MII-Switch (MAC or PHY mode MII) and MII-P5 (PHY mode MII). • IEEE 802.1q tag-based VLAN (16 VLANs, full-range VID) for DMZ port, WAN/LAN separation or interVLAN switch links • VLAN ID tag/untag options, per-port basis • Programmable rate limiting 0Mbps to 100Mbps, ingress and egress port, rate options for high and low priority, per-port basis in 32Kbps increments • Flow control or drop packet rate limiting (ingress port) • Integrated MIB counters for fully-compliant statistics gathering, 34 MIB counters per port • MDC and MDI/O interface support to access the MII PHY control registers (not all control registers) • MII local loopback support • On-chip 64Kbyte memory for frame buffering (not shared with 1K unicast address table) • Wire-speed reception and transmission • Integrated look-up engine with dedicated 1K MAC addresses • Full duplex IEEE 802.3x and half-duplex back pressure flow control • Comprehensive LED support • 7-wire SNI support for legacy MAC interface • Automatic MDI/MDI-X crossover for plug-and-play • Disable automatic MDI/MDI-X option • Low power: − Core: 1.8V − Digital I/O: 3.3V − Analog I/O: 3.3V • 0.18µm CMOS technology • Temperature ranges: • Enable/Disable option for huge frame size up to 1916 bytes per frame • IGMP v1/v2 snooping for multicast packet filtering − Commercial: 0°C to +70°C • Special tagging mode to send CPU info on ingress packet’s port value − Industrial: –40°C to +85°C • • SPI slave (complete) and MDIO (MII PHY only) serial management interface for control of register configuration Applications • MAC-id based security lock option • Control registers configurable on-the-fly (portpriority, 802.1p/d/q, AN...) • CPU read access to MAC forwarding table entries • 802.1d spanning tree protocol • Port mirroring/monitoring/sniffing: ingress and/or egress traffic to any port or MII • Broadcast storm protection with % control – global and per-port basis • Optimization for fiber-to-copper media conversion • Full-chip hardware power-down support (register configuration not saved) • Per-port based software power-save on PHY (idle link detection, register configuration preserved) • QoS/CoS packets prioritization supports: − • • • • • • • • • • Available in 128-pin PQFP package Broadband gateway/firewall/VPN Integrated DSL or cable modem multi-port router Wireless LAN access point plus gateway Home networking expansion Standalone 10/100 switch Hotel/campus/MxU gateway Enterprise VoIP gateway/phone FTTx customer premise equipment Managed media converter Per port, 802.1p and DiffServ based 802.1p/q tag insertion or removal on a per-port basis (egress) October 2011 2 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Ordering Information Part Number Temperature Range Package 0°C to +70°C 128-Pin PQFP KSZ8995FQ 0°C to +70°C 128-Pin PQFP KSZ8995MAI −40°C to +85°C 128-Pin PQFP KSZ8995FQI −40°C to +85°C 128-Pin PQFP Standard Pb (lead)-Free KS8995MA KSZ8995MA KS8995FQ KS8995MAI KS8995FQI Revision History Revision Date 2.0 10/10/03 Created. 2.1 10/30/03 Editorial changes on electrical characteristics. 2.2 04/01/04 Editorial changes on the TTL input and output electrical characteristics. 2.3 01/19/05 Insert recommended reset circuit, pg. 70. Editorial, Pg. 36. 2.4 04/13/05 Changed VDDIO to 3.3V. Changed Jitter to 16 ns Max. 2.5 02/06/06 Added Pb-Free option for Industrial version. 2.6 07/12/06 Add a note for VLAN table write, improve the timing diagram for MII interface, update pin description for PCRS, PCOL, etc. And update the description of the register bits for the loopback, etc. 2.7 06/01/07 Add the package thermal information in the operating rating and the transformer power consumption information in the electrical characteristics note. 2.8 03/20/08 Add KSZ8995FQ information and pin description. 2.9 09/15/08 Add KSZ8995FQ block diagram and descriptions for revision ID and LED mode. 10/26/11 Update some descriptions for VDDAT voltage MDI/MDIX bits of registers, update equation of the broadcast storm protection, correct typo. 3.0 October 2011 Summary of Changes 3 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Contents System Level Applications................................................................................................................................................. 11 Pin Configuration ................................................................................................................................................................ 13 Pin Description − By Number............................................................................................................................................. 14 Pin Description − By Name ................................................................................................................................................ 20 Introduction ......................................................................................................................................................................... 26 Functional Overview: Physical Layer Transceiver .......................................................................................................... 26 100BASE-TX Transmit ..................................................................................................................................................... 26 100BASE-TX Receive ...................................................................................................................................................... 26 PLL Clock Synthesizer ...................................................................................................................................................... 26 Scrambler/De-Scrambler (100BASE-TX Only) ................................................................................................................. 27 100BASE-FX Operation .................................................................................................................................................... 27 100BASE-FX Signal Detection ......................................................................................................................................... 27 100BASE-FX Far End fault ............................................................................................................................................... 27 10BASE-T Transmit .......................................................................................................................................................... 27 10BASE-T Receive ........................................................................................................................................................... 27 Power Management .......................................................................................................................................................... 27 MDI/MDI-X Auto Crossover .............................................................................................................................................. 27 Auto-Negotiation ............................................................................................................................................................... 28 Functional Overview: Switch Core .................................................................................................................................... 29 Address Look-Up .............................................................................................................................................................. 29 Learning ............................................................................................................................................................................ 29 Migration ........................................................................................................................................................................... 29 Aging ................................................................................................................................................................................. 29 Forwarding ........................................................................................................................................................................ 29 Switching Engine .............................................................................................................................................................. 29 Media Access Controller (MAC) Operation ...................................................................................................................... 30 MII Interface Operation ..................................................................................................................................................... 33 SNI Interface Operation .................................................................................................................................................... 36 Advanced Functionality...................................................................................................................................................... 36 Spanning Tree Support ..................................................................................................................................................... 36 Special Tagging Mode ...................................................................................................................................................... 37 IGMP Support ................................................................................................................................................................... 39 Port Mirroring Support ...................................................................................................................................................... 39 VLAN Support ................................................................................................................................................................... 40 Rate Limit Support ............................................................................................................................................................ 40 October 2011 4 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Configuration Interface ..................................................................................................................................................... 41 MII Management Interface (MIIM) .................................................................................................................................... 45 Register Description ........................................................................................................................................................... 46 Global Registers .................................................................................................................................................................. 47 Register 0 (0x00): Chip ID0 .............................................................................................................................................. 47 Register 2 (0x02): Global Control 0 .................................................................................................................................. 47 Register 4 (0x04): Global Control 2 .................................................................................................................................. 49 Register 5 (0x05): Global Control 3 .................................................................................................................................. 50 Register 6 (0x07): Global Control 4 .................................................................................................................................. 51 Register 7 (0x07): Global Control 5 .................................................................................................................................. 51 Register 8 (0x08): Global Control 6 .................................................................................................................................. 51 Register 9 (0x09): Global Control 7 .................................................................................................................................. 51 Register 10 (0x0A): Global Control 8 ................................................................................................................................ 52 Register 11 (0x0B): Global Control 9 ................................................................................................................................ 52 Port Registers ...................................................................................................................................................................... 53 Register 16 (0x10): Port 1 Control 0 ................................................................................................................................. 53 Register 32 (0x20): Port 2 Control 0 ................................................................................................................................. 53 Register 48 (0x30): Port 3 Control 0 ................................................................................................................................. 53 Register 64 (0x40): Port 4 Control 0 ................................................................................................................................. 53 Register 80 (0x50): Port 5 Control 0 ................................................................................................................................. 53 Register 17 (0x11): Port 1 Control 1 ................................................................................................................................. 54 Register 33 (0x21): Port 2 Control 1 ................................................................................................................................. 54 Register 49 (0x31): Port 3 Control 1 ................................................................................................................................. 54 Register 65 (0x41): Port 4 Control 1 ................................................................................................................................. 54 Register 81 (0x51): Port 5 Control 1 ................................................................................................................................. 54 Register 18 (0x12): Port 1 Control 2 ................................................................................................................................. 54 Register 34 (0x22): Port 2 Control 2 ................................................................................................................................. 54 Register 50 (0x32): Port 3 Control 2 ................................................................................................................................. 54 Register 66 (0x42): Port 4 Control 2 ................................................................................................................................. 54 Register 82 (0x52): Port 5 Control 2 ................................................................................................................................. 54 Register 19 (0x13): Port 1 Control 3 ................................................................................................................................. 55 Register 35 (0x23): Port 2 Control 3 ................................................................................................................................. 55 Register 51 (0x33): Port 3 Control 3 ................................................................................................................................. 55 Register 67 (0x43): Port 4 Control 3 ................................................................................................................................. 55 Register 83 (0x53): Port 5 Control 3 ................................................................................................................................. 55 Register 20 (0x14): Port 1 Control 4 ................................................................................................................................. 55 Register 36 (0x24): Port 2 Control 4 ................................................................................................................................. 55 October 2011 5 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Register 52 (0x34): Port 3 Control 4 ................................................................................................................................. 55 Register 68 (0x44): Port 4 Control 4 ................................................................................................................................. 55 Register 84 (0x54): Port 5 Control 4 ................................................................................................................................. 55 Register 21 (0x15): Port 1 Control 5 ................................................................................................................................. 56 Register 37 (0x25): Port 2 Control 5 ................................................................................................................................. 56 Register 53 (0x35): Port 3 Control 5 ................................................................................................................................. 56 Register 69 (0x45): Port 4 Control 5 ................................................................................................................................. 56 Register 85 (0x55): Port 5 Control 5 ................................................................................................................................. 56 Register 22 (0x16): Port 1 Control 6 ................................................................................................................................. 56 Register 38 (0x26): Port 2 Control 6 ................................................................................................................................. 56 Register 54 (0x36): Port 3 Control 6 ................................................................................................................................. 56 Register 70 (0x46): Port 4 Control 6 ................................................................................................................................. 56 Register 86 (0x56): Port 5 Control 6 ................................................................................................................................. 56 Register 23 (0x17): Port 1 Control 7 ................................................................................................................................. 56 Register 39 (0x27): Port 2 Control 7 ................................................................................................................................. 56 Register 55 (0x37): Port 3 Control 7 ................................................................................................................................. 56 Register 71 (0x47): Port 4 Control 7 ................................................................................................................................. 56 Register 87 (0x57): Port 5 Control 7 ................................................................................................................................. 56 Register 25 (0x19): Port 1 Control 9 ................................................................................................................................. 57 Register 41 (0x29): Port 2 Control 9 ................................................................................................................................. 57 Register 57 (0x39): Port 3 Control 9 ................................................................................................................................. 57 Register 73 (0x49): Port 4 Control 9 ................................................................................................................................. 57 Register 89 (0x59): Port 5 Control 9 ................................................................................................................................. 57 Register 26 (0x1A): Port 1 Control 10............................................................................................................................... 57 Register 42 (0x2A): Port 2 Control 10............................................................................................................................... 57 Register 58 (0x3A): Port 3 Control 10............................................................................................................................... 57 Register 74 (0x4A): Port 4 Control 10............................................................................................................................... 57 Register 90 (0x5A): Port 5 Control 10............................................................................................................................... 57 Register 28 (0x1C): Port 1 Control 12 .............................................................................................................................. 58 Register 44 (0x2C): Port 2 Control 12 .............................................................................................................................. 58 Register 60 (0x3C): Port 3 Control 12 .............................................................................................................................. 58 Register 76 (0x4C): Port 4 Control 12 .............................................................................................................................. 58 Register 92 (0x5C): Port 5 Control 12 .............................................................................................................................. 58 Register 29 (0x1D): Port 1 Control 13 .............................................................................................................................. 59 Register 45 (0x2D): Port 2 Control 13 .............................................................................................................................. 59 Register 61 (0x3D): Port 3 Control 13 .............................................................................................................................. 59 Register 77 (0x4D): Port 4 Control 13 .............................................................................................................................. 59 October 2011 6 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Register 93 (0x5D): Port 5 Control 13 .............................................................................................................................. 59 Register 30 (0x1E): Port 1 Status 0 .................................................................................................................................. 60 Register 46 (0x2E): Port 2 Status 0 .................................................................................................................................. 60 Register 62 (0x3E): Port 3 Status 0 .................................................................................................................................. 60 Register 78 (0x4E): Port 4 Status 0 .................................................................................................................................. 60 Register 94 (0x5E): Port 5 Status 0 .................................................................................................................................. 60 Register 31 (0x1F): Port 1 Control 14 ............................................................................................................................... 60 Register 47 (0x2F): Port 2 Control 14 ............................................................................................................................... 60 Register 63 (0x3F): Port 3 Control 14 ............................................................................................................................... 60 Register 79 (0x4F): Port 4 Control 14 ............................................................................................................................... 60 Register 95 (0x5F): Port 5 Control 14 ............................................................................................................................... 60 Advanced Control Registers .............................................................................................................................................. 61 Register 96 (0x60): TOS Priority Control Register 0 ........................................................................................................ 61 Register 97 (0x61): TOS Priority Control Register 1 ........................................................................................................ 61 Register 98 (0x62): TOS Priority Control Register 2 ........................................................................................................ 61 Register 99 (0x63): TOS Priority Control Register 3 ........................................................................................................ 61 Register 100 (0x64): TOS Priority Control Register 4 ...................................................................................................... 61 Register 101 (0x65): TOS Priority Control Register 5 ...................................................................................................... 61 Register 102 (0x66): TOS Priority Control Register 6 ...................................................................................................... 62 Register 103 (0x67): TOS Priority Control Register 7 ...................................................................................................... 62 Register 104 (0x68): MAC Address Register 0 ................................................................................................................ 62 Register 105 (0x69): MAC Address Register 1 ................................................................................................................ 62 Register 106 (0x6A): MAC Address Register 2 ................................................................................................................ 62 Register 107 (0x6B): MAC Address Register 3 ................................................................................................................ 62 Register 108 (0x6C): MAC Address Register 4 ................................................................................................................ 62 Register 109 (0X6D): MAC Address Register 5 ............................................................................................................... 63 Register 110 (0x6E): Indirect Access Control 0 ................................................................................................................ 63 Register 111 (0x6F): Indirect Access Control 1 ................................................................................................................ 63 Register 112 (0x70): Indirect Data Register 8 .................................................................................................................. 64 Register 113 (0x71): Indirect Data Register 7 .................................................................................................................. 64 Register 114 (0x72): Indirect Data Register 6 .................................................................................................................. 64 Register 115 (0x73): Indirect Data Register 5 .................................................................................................................. 64 Register 116 (0x74): Indirect Data Register 4 .................................................................................................................. 64 Register 117 (0x75): Indirect Data Register 3 .................................................................................................................. 64 Register 118 (0x76): Indirect Data Register 2 .................................................................................................................. 64 Register 119 (0x77): Indirect Data Register 1 .................................................................................................................. 64 Register 120 (0x78): Indirect Data Register 0 .................................................................................................................. 65 October 2011 7 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Register 121 (0x79): Digital Testing Status 0 ................................................................................................................... 65 Register 122 (0x7A): Digital Testing Status 1 ................................................................................................................... 65 Register 123 (0x7B): Digital Testing Control 0 ................................................................................................................. 65 Register 124 (0x7C): Digital Testing Control 1 ................................................................................................................. 65 Register 125 (0x7D): Analog Testing Control 0 ................................................................................................................ 65 Register 126 (0x7E): Analog Testing Control 1 ................................................................................................................ 65 Register 127 (0x7F): Analog Testing Status ..................................................................................................................... 65 Static MAC Address ............................................................................................................................................................ 66 Static Address Table Examples ........................................................................................................................................ 67 Static Address Table Write Examples .............................................................................................................................. 67 VLAN Address ..................................................................................................................................................................... 68 VLAN Table Read Example .............................................................................................................................................. 68 VLAN Table Write Example .............................................................................................................................................. 68 Dynamic MAC Address....................................................................................................................................................... 69 Dynamic MAC Address Table Read Example .................................................................................................................. 69 Dynamic MAC Address Table Write Example .................................................................................................................. 70 MIB Counters ....................................................................................................................................................................... 71 For port 2, the base is 0x20, same offset definition (0x20-0x3f) ...................................................................................... 72 For port 3, the base is 0x40, same offset definition (0x40-0x5f) ...................................................................................... 72 For port 4, the base is 0x60, same offset definition (0x60-0x7f) ...................................................................................... 72 MIB Counter Read Examples ........................................................................................................................................... 73 MIIM Registers ..................................................................................................................................................................... 74 Absolute Maximum Ratings(1) ............................................................................................................................................ 77 Operating Ratings(2) ............................................................................................................................................................ 77 Electrical Characteristics(4, 5) .............................................................................................................................................. 77 Timing Diagrams ................................................................................................................................................................. 79 Reset Circuit Diagram ....................................................................................................................................................... 86 Selection of Isolation Transformer .................................................................................................................................... 87 Package Information ........................................................................................................................................................... 88 October 2011 8 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ List of Figures Figure 1. Broadband Gateway ............................................................................................................................................ 11 Figure 2. Integrated Broadband Router .............................................................................................................................. 11 Figure 3. Standalone Switch ............................................................................................................................................... 12 Figure 4. Using KS8995FQ for Dual Media Converter or Fiber Daisy Chain Connection .................................................. 12 Figure 5. Auto Negotiation .................................................................................................................................................. 28 Figure 6. DA Look-Up Flowchart − 1 ................................................................................................................................... 31 Figure 7. DA Resolution Flowchart − Stage 2 ..................................................................................................................... 32 Figure 8. KS8995MA/FQ EEPROM Configuration Timing Diagram ................................................................................... 43 Figure 9. SPI Write Data Cycle ........................................................................................................................................... 44 Figure 10. SPI Read Data Cycle ........................................................................................................................................... 44 Figure 11. SPI Multiple Write ................................................................................................................................................ 45 Figure 12. SPI Multiple Read ................................................................................................................................................ 45 Figure 13. EEPROM Interface Input Receive Timing Diagram............................................................................................. 79 Figure 14. EEPROM Interface Output Transmit Timing Diagram ......................................................................................... 79 Figure 15. SNI Input Timing .................................................................................................................................................. 80 Figure 16. SNI Output Timing ............................................................................................................................................... 80 Figure 17. MAC Mode MII Timing − Data Received from MII ............................................................................................... 81 Figure 18. MAC Mode MII Timing − Data Transmitted from MII ........................................................................................... 81 Figure 19. PHY Mode MII Timing − Data Received from MII ................................................................................................ 82 Figure 20. PHY Mode MII Timing − Data Transmitted from MII ............................................................................................ 82 Figure 21. SPI Input Timing .................................................................................................................................................. 83 Figure 22. SPI Output Timing................................................................................................................................................ 84 Figure 23. Reset Timing ........................................................................................................................................................ 85 Figure 24. Recommended Reset Circuit ............................................................................................................................... 86 Figure 25. Recommended Circuit for Interfacing with CPU/FPGA Reset ............................................................................. 86 October 2011 9 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ List of Tables Table 1. MII − P5 Signals (PHY Mode) ............................................................................................................................... 34 Table 2. MII − SW Signals................................................................................................................................................... 35 Table 3. SNI Signals ........................................................................................................................................................... 36 Table 5. STPID Egress Rules (Processor to Switch Port 5) ............................................................................................... 38 Table 6. STPID Egress Rules (Switch to Processor) .......................................................................................................... 38 Table 7. FID+DA Look-Up in the VLAN Mode .................................................................................................................... 40 Table 8. FID+SA Look-Up in the VLAN Mode .................................................................................................................... 40 Table 9. SPI Connections ................................................................................................................................................... 44 Table 10. EEPROM Timing Parameters ............................................................................................................................... 79 Table 11. SNI Timing Parameters ......................................................................................................................................... 80 Table 12. MAC Mode MII Timing Parameters....................................................................................................................... 81 Table 13. PHY Mode MII Timing Parameters ....................................................................................................................... 82 Table 14. SPI Input Timing Parameters ................................................................................................................................ 83 Table 15. SPI Output Timing Parameters ............................................................................................................................. 84 Table 16. Reset Timing Parameters ..................................................................................................................................... 85 Table 17. Qualified Magnetic Vendors .................................................................................................................................. 87 October 2011 10 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ System Level Applications Figure 1. Broadband Gateway Figure 2. Integrated Broadband Router October 2011 11 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ System Level Applications (Continued) Figure 3. Standalone Switch Figure 4. Using KS8995FQ for Dual Media Converter or Fiber Daisy Chain Connection October 2011 12 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Pin Configuration 128-Pin PQFP October 2011 13 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Pin Description − By Number Pin Number Pin Name Type(1) Port Pin Function(2) 1 MDI-XDIS lpd 1−5 Disable auto MDI/MDI-X. PD (default) = normal operation. PU = disable auto MDI/MDI-X on all ports. 2 GNDA GND 3 VDDAR P Notes: 1. 2. Analog ground. 1.8V analog VDD. 4 RXP1 I 1 Physical receive signal + (differential). 5 RXM1 I 1 Physical receive signal – (differential). 6 GNDA GND 7 TXP1 O 1 Physical transmit signal + (differential). 8 TXM1 O 1 Physical transmit signal – (differential). 9 VDDAT P 10 RXP2 I 2 Physical receive signal + (differential). 2 Physical receive signal – (differential). Analog ground. 3.3V analog VDD. (2.5V or 3.3V is for B3 and previous chip revision) 11 RXM2 I 12 GNDA GND 13 TXP2 O 2 Physical transmit signal + (differential). 14 TXM2 O 2 Physical transmit signal – (differential). 15 VDDAR P 16 GNDA GND 17 ISET 18 VDDAT P 19 RXP3 I 3 Physical receive signal + (differential). 3 Physical receive signal - (differential). Analog ground. 1.8V analog VDD. Analog ground. Set physical transmit output current. Pull-down with a 3.01kΩ1% resistor. 3.3V analog VDD. (2.5V or 3.3V is for B3 and previous chip revision) 20 RXM3 I 21 GNDA GND 22 TXP3 O 3 Physical transmit signal + (differential). 23 TXM3 O 3 Physical transmit signal – (differential). 24 VDDAT P 25 RXP4 I 4 Physical receive signal + (differential). 26 RXM4 I 4 Physical receive signal - (differential). 27 GNDA GND 28 TXP4 O 4 Physical transmit signal + (differential). 29 TXM4 O 4 Physical transmit signal – (differential). 30 GNDA GND Analog ground. 3.3V analog VDD. (2.5V or 3.3V is for B3 and previous chip revision) Analog ground. Analog ground. P = Power supply. I = Input. O = Output. I/O = Bidirectional. GND = Ground. Ipu = Input w/internal pull-up. Ipd = Input w/internal pull-down. Ipd/O = Input w/internal pull-down during reset, output pin otherwise. Ipu/O = Input w/internal pull-up during reset, output pin otherwise. NC = No connect. PU = Strap pin pull-up. PD = Strap pull-down. October 2011 14 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Pin Description − By Numbers (Continued) Pin Number Pin Name Type(1) 31 VDDAR P 32 RXP5 I 5 Physical receive signal + (differential). 5 Physical receive signal – (differential). Port Pin Function 1.8V analog VDD. 33 RXM5 I 34 GNDA GND 35 TXP5 O 5 Physical transmit signal + (differential). 36 TXM5 O 5 Physical transmit signal – (differential). 37 VDDAT P 38 FXSD5/FXSD3 Ipd 39 FXSD4 Ipd 40 GNDA GND 41 VDDAR P 42 GNDA GND 43 VDDAR P 44 GNDA GND 45 MUX1 NC Factory test pins. MUX1 and MUX2 should be left unconnected for normal operation. 46 MUX2 NC Mode 47 PWRDN_N Ipu Full-chip power down. Active low. 48 RESERVE NC Reserved pin. No connect. 49 GNDD GND 50 VDDC P 51 PMTXEN Ipd 5 PHY[5] MII transmit enable. 52 PMTXD3 Ipd 5 PHY[5] MII transmit bit 3. 53 PMTXD2 Ipd 5 PHY[5] MII transmit bit 2. 54 PMTXD1 Ipd 5 PHY[5] MII transmit bit 1. 55 PMTXD0 Ipd 5 PHY[5] MII transmit bit 0. 56 PMTXER Ipd 5 PHY[5] MII transmit error. 57 PMTXC O 5 PHY[5] MII transmit clock. PHY mode MII. 58 GNDD GND 59 VDDIO P 60 PMRXC O Analog ground. 3.3V analog VDD. (2.5V or 3.3V is for B3 and previous chip revision) 5/3 4 Fiber signal detect pin. FXSD5 is for port 5 of the KS8995MA. FXSD3 is for port 3 of the KS8995FQ Fiber signal detect pin for port 4. Analog ground. 1.8V analog VDD. Analog ground. 1.8V analog VDD. Analog ground. MUX1 MUX2 NC NC Normal Operation Note: 1. Digital ground. 1.8V digital core VDD. Digital ground. 3.3V digital VDD for digital I/O circuitry. 5 PHY[5] MII receive clock. PHY mode MII. P = Power supply. I = Input. O = Output. I/O = Bidirectional. GND = Ground. Ipu = Input w/internal pull-up. Ipd = Input w/internal pull-down. Ipd/O = Input w/internal pull-down during reset, output pin otherwise. Ipu/O = Input w/internal pull-up during reset, output pin otherwise. NC = No connect. October 2011 15 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Pin Description − By Numbers (Continued) Pin Number Pin Name Type(1) 61 PMRXDV Ipd/O Notes: 1. 2. Port Pin Function(2) 5 PHY[5] MII receive data valid. 5 PHY[5] MII receive bit 3. Strap option: PD (default) = enable flow control; PU = disable flow control. 5 PHY[5] MII receive bit 2. Strap option: PD (default) = disable back pressure; PU = enable back pressure. 5 PHY[5] MII receive bit 1. Strap option: PD (default) = drop excessive collision packets; PU = does not drop excessive collision packets. 5 PHY[5] MII receive bit 0. Strap option: PD (default) = disable aggressive back-off algorithm in half-duplex mode; PU = enable for performance enhancement. 5 PHY[5] MII receive error. Strap option: PD (default) = packet size 1518/1522 bytes; PU = 1536 bytes. 5 PHY[5] MII carrier sense/strap option for port 4 only. PD (default) = force half-duplex if auto-negotiation is disabled or fails. PU = force full-duplex if auto negotiation is disabled or fails. Refer to Register 76. 5 PHY[5] MII collision detect/ strap option for port 4 only. PD (default) = no force flow control, normal operation. PU = force flow control. Refer to Register 66 62 PMRXD3 Ipd/O 63 PMRXD2 Ipd/O 64 PMRXD1 Ipd/O 65 PMRXD0 Ipd/O 66 PMRXER Ipd/O 67 PCRS Ipd/O 68 PCOL Ipd/O 69 SMTXEN Ipd Switch MII transmit enable. 70 SMTXD3 Ipd Switch MII transmit bit 3. 71 SMTXD2 Ipd Switch MII transmit bit 2. 72 SMTXD1 Ipd Switch MII transmit bit 1. 73 SMTXD0 Ipd Switch MII transmit bit 0. 74 SMTXER Ipd Switch MII transmit error. 75 SMTXC I/O Switch MII transmit clock. Input in MAC mode, output in PHY mode MII. 76 GNDD GND 77 VDDIO P 78 SMRXC I/O 79 SMRXDV Ipd/O Switch MII receive data valid. Digital ground. 3.3V digital VDD for digital I/O circuitry. Switch MII receive clock. Input in MAC mode, output in PHY mode MII. 80 SMRXD3 Ipd/O Switch MII receive bit 3. Strap option: PD (default) = Disable Switch MII full-duplex flow control; PU = Enable Switch MII full-duplex flow control. 81 SMRXD2 Ipd/O Switch MII receive bit 2. Strap option: PD (default) = Switch MII in full-duplex mode; PU = Switch MII in half-duplex mode. P = Power supply. I = Input. O = Output. I/O = Bidirectional. GND = Ground. Ipu = Input w/internal pull-up. Ipd = Input w/internal pull-down. Ipd/O = Input w/internal pull-down during reset, output pin otherwise. Ipu/O = Input w/internal pull-up during reset, output pin otherwise. NC = No connect. PU = Strap pin pull-up. PD = Strap pull-down. October 2011 16 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Pin Description − By Numbers (Continued) Pin Number Pin Name Type(1) 82 SMRXD1 Ipd/O Port Pin Function(2) Switch MII receive bit 1. Strap option: PD (default) = Switch MII in 100Mbps mode; PU = Switch MII in 10Mbps mode. Switch MII receive bit 0; Strap option: LED mode; PD (default) = mode 0; PU = mode 1. See “Register 11”. Mode 0, link at: 100/Full LEDx[2,1,0]=0,0,0 100/Half LEDx[2,1,0]=0,1,0 10/Full LEDx[2,1,0]=0,0,1 10/Half LEDx[2,1,0]=0,1,1 Mode 1, link at 83 2. Ipd/O 84 SCOL Ipd/O 85 SCRS Ipd/O 86 Notes: 1. SMRXD0 SCONF1 SCONF0 Ipd 88 GNDD GND 89 VDDC P 100/Half LEDx[2,1,0]=0,1,1 10/Full LEDx[2,1,0]=1,0,0 10/Half LEDx[2,1,0]=1,0,1 Mode 0 Mode 1 LEDX_2 Lnk/Act 100Lnk/Act LEDX_1 Fulld/Col 10Lnk/Act LEDX_0 Speed Full duplex Switch MII collision detect. Switch mode carrier sense. Dual MII configuration pin. For the Switch MII, KSZ8995MA supports both MAC mode and PHY mode, KSZ8995FQ supports PHY mode only. Ipd 87 100/Full LEDx[2,1,0]=0,1,0 Pin# (91, 86, 87): Switch MII PHY [5] MII 000 Disable, Otri Disable, Otri 001 PHY Mode MII Disable, Otri 010 MAC Mode MII Disable, Otri 011 PHY Mode SNI Disable, Otri 100 Disable Disable 101 PHY Mode MII PHY Mode MII 110 MAC Mode MII PHY Mode MII 111 PHY Mode SNI PHY Mode MII Dual MII configuration pin. Digital ground. 1.8V digital core VDD. 90 LED5-2 Ipu/O 5 LED indicator 2. Strap option: aging setup. See “Aging” section. PU (default) = aging enable; PD = aging disable. 91 LED5-1 Ipu/O 5 LED indicator 1. Strap option: PU (default): enable PHY[5] MII I/F. PD: tristate all PHY[5] MII output. See “Pin 86 SCONF1.” P = Power supply. I = Input. O = Output. I/O = Bidirectional. GND = Ground. Ipu = Input w/internal pull-up. Ipd = Input w/internal pull-down. Ipd/O = Input w/internal pull-down during reset, output pin otherwise. Ipu/O = Input w/internal pull-up during reset, output pin otherwise. NC = No connect. PU = Strap pin pull-up. PD = Strap pull-down. Otri = Output tristated. Fulld = Full duplex October 2011 17 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Pin Description − By Numbers (Continued) Pin Number Pin Name Type(1) Port 92 LED5-0 Ipu/O 5 LED indicator 0. 93 LED4-2 Ipu/O 4 LED indicator 2. 94 LED4-1 Ipu/O 4 LED indicator 1. 95 LED4-0 Ipu/O 4 LED indicator 0. 96 LED3-2 Ipu/O 3 LED indicator 2. 97 LED3-1 Ipu/O 3 LED indicator 1. 98 LED3-0 Ipu/O 3 99 GNDD GND 100 VDDIO P 101 LED2-2 Ipu/O 2 LED indicator 2. 102 LED2-1 Ipu/O 2 LED indicator 1. 103 LED2-0 Ipu/O 2 LED indicator 0. 104 LED1-2 Ipu/O 1 LED indicator 2. 105 LED1-1 Ipu/O 1 LED indicator 1. 106 LED1-0 Ipu/O 1 LED indicator 0. 107 MDC Ipu All Switch or PHY[5] MII management data clock. 108 MDIO I/O All Switch or PHY[5] MII management data I/O. Features internal pull down to define pin state when not driven. 109 SPIQ Otri All (1) SPI serial data output in SPI slave mode; (2) output clock at 61kHz in I2C master mode. See “Pin 113.” 110 SPIC/SCL I/O All (1) Input clock up to 5MHz in SPI slave mode; (2) output clock at 61kHz in I2C master mode. See “Pin 113.” 111 SSPID/SDA I/O All (1) Serial data input in SPI slave mode; (2) serial data input/output in I2C master mode. See “Pin 113.” 112 SPIS_N Ipu All Active low. (1) SPI data transfer start in SPI slave mode. When SPIS_N is high, the KS8995MA/FQ is deselected and SPIQ is held in high impedance state, a high-to-low transition to initiate the SPI data transfer; (2) not used in I2C master mode. Pin Function LED indicator 0. Digital ground. 3.3V digital VDD for digital I/O. Serial bus configuration pin. For this case, if the EEPROM is not present, the KS8995MA/FQ will start itself with the PS[1.0] = 00 default register values. 113 Note: 1. PS1 Ipd Pin Configuration Serial Bus Configuration PS[1.0]=00 I2C Master Mode for EEPROM PS[1.0]=01 Reserved PS[1.0]=10 SPI Slave Mode for CPU Interface PS[1.0]=11 Factory Test Mode (BIST) P = Power supply. I = Input. O = Output. I/O = Bidirectional. GND = Ground. Ipu = Input w/internal pull-up. Ipd = Input w/internal pull-down. Ipd/O = Input w/internal pull-down during reset, output pin otherwise. Ipu/O = Input w/internal pull-up during reset, output pin otherwise. NC = No connect. October 2011 18 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Pin Description − By Numbers (Continued) Pin Number Pin Name Type(1) 114 PS0 Ipd Serial bus configuration pin. See “Pin 113.” 115 RST_N Ipu Reset the KS8995MA/FQ. Active low. 116 GNDD GND 117 VDDC P 118 TESTEN Ipd NC for normal operation. Factory test pin. 119 SCANEN Ipd NC for normal operation. Factory test pin. 120 NC NC No connect. 121 X1 I 122 X2 O 25MHz crystal clock connection. 123 VDDAP P 1.8V analog VDD for PLL. 124 GNDA GND 125 VDDAR P 126 GNDA GND Analog ground. 127 GNDA GND Analog ground. 128 TEST2 NC Note: 1. Port Pin Function Digital ground. 1.8V digital core VDD. 25MHz crystal clock connection/or 3.3V tolerant oscillator input. Oscillator should be ±50ppm. Analog ground. 1.8V analog VDD. NC for normal operation. Factory test pin. P = Power supply. I = Input. O = Output. I/O = Bidirectional. GND = Ground. Ipu = Input w/internal pull-up Ipd = Input w/internal pull-down. Ipd/O = Input w/internal pull-down during reset, output pin otherwise. Ipu/O = Input w/internal pull-up during reset, output pin otherwise. NC = No connect. October 2011 19 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Pin Description − By Name Pin Number Pin Name Type(1) Port 39 FXSD4 I 4 3/5 Note: 1. Pin Function Fiber signal detect/Factory test pin. 38 FXSD3/FXSD5 I 124 GNDA GND Fiber signal detect/Factory test pin for FQ port 3 or MA port 5 Analog ground. 42 GNDA GND Analog ground. 44 GNDA GND Analog ground. 2 GNDA GND Analog ground. 16 GNDA GND Analog ground. 30 GNDA GND Analog ground. 6 GNDA GND Analog ground. 12 GNDA GND Analog ground. 21 GNDA GND Analog ground. 27 GNDA GND Analog ground. 34 GNDA GND Analog ground. 40 GNDA GND Analog ground. 120 NC NC 127 GNDA GND Analog ground. 126 GNDA GND Analog ground. 49 GNDD GND Digital ground. No connect. 88 GNDD GND Digital ground. 116 GNDD GND Digital ground. 58 GNDD GND Digital ground. 76 GNDD GND Digital ground. 99 GNDD GND Digital ground. 17 ISET 106 LED1-0 Ipu/O 1 LED indicator 0. 105 LED1-1 Ipu/O 1 LED indicator 1. 104 LED1-2 Ipu/O 1 LED indicator 2. 103 LED2-0 Ipu/O 2 LED indicator 0. 102 LED2-1 Ipu/O 2 LED indicator 1. 101 LED2-2 Ipu/O 2 LED indicator 2. 98 LED3-0 Ipu/O 3 LED indicator 0. Set physical transmit output current. Pull-down with a 3.01kΩ1% resistor. P = Power supply. I = Input. O = Output. I/O = Bidirectional. GND = Ground. Ipu = Input w/internal pull-up. Ipd = Input w/internal pull-down. Ipd/O = Input w/internal pull-down during reset, output pin otherwise. Ipu/O = Input w/internal pull-up during reset, output pin otherwise. NC = No connect. October 2011 20 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Pin Description − By Name (Continued) Pin Number Pin Name Type(1) Port Pin Function(2) 97 LED3-1 Ipu/O 3 LED indicator 1. 96 LED3-2 Ipu/O 3 LED indicator 2. 95 LED4-0 Ipu/O 4 LED indicator 0. 94 LED4-1 Ipu/O 4 LED indicator 1. 93 LED4-2 Ipu/O 4 LED indicator 2. 92 LED5-0 Ipu/O 5 LED indicator 0. 91 LED5-1 Ipu/O 5 LED indicator 1. Strap option: PU (default) = enable PHY MII I/F PD: tristate all PHY MII output. See “Pin 86 SCONF1.” 90 LED5-2 Ipu/O 5 LED indicator 2. Strap option: aging setup. See “Aging” section. (default) = aging enable; PD = aging disable. 107 MDC Ipu All Switch or PHY[5] MII management data clock. 108 MDIO I/O All Switch or PHY[5] MII management data I/O. 1-5 Disable auto MDI/MDI-X. 1 MDI-XDIS Ipd 45 MUX1 NC 46 MUX2 NC Factory test pins. MUX1 and MUX2 should be left unconnected for normal operation. Mode MUX1 MUX2 NC NC Normal Operation Notes: 1. 2. 68 PCOL Ipd/O 5 PHY[5] MII collision detect/force flow control. See “Register 18.” For port 4 only. PD (default) = no force flow control. PU = force flow control. 67 PCRS Ipd/O 5 PHY[5] MII carrier sense/force duplex mode. See “Register 28.” For port 4 only. PD (default) = force half-duplex if auto-negotiation is disabled or fails. PU = force fullduplex if auto-negotiation is disabled or fails. 60 PMRXC O 5 PHY[5] MII receive clock. PHY mode MII. 65 PMRXD0 Ipd/O 5 PHY[5] MII receive bit 0. Strap option: PD (default) = disable aggressive back-off algorithm in half-duplex mode; PU = enable for performance enhancement. 64 PMRXD1 Ipd/O 5 PHY[5] MII receive bit 1. Strap option: PD (default) = drop excessive collision packets; PU = does not drop excessive collision packets. 63 PMRXD2 Ipd/O 5 PHY[5] MII receive bit 2. Strap option: PD (default) = disable back pressure; PU = enable back pressure. 62 PMRXD3 Ipd/O 5 PHY[5] MII receive bit 3. Strap option: PD (default) = enable flow control; PU = disable flow control. 61 PMRXDV Ipd/O 5 PHY[5] MII receive data valid. P = Power supply. I = Input. O = Output. I/O = Bidirectional. GND = Ground. Ipu = Input w/internal pull-up. Ipd = Input w/internal pull-down. Ipd/O = Input w/internal pull-down during reset, output pin otherwise. Ipu/O = Input w/internal pull-up during reset, output pin otherwise. NC = No connect. PU = Strap pin pull-up. PD = Strap pull-down. October 2011 21 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Pin Description − By Name Pin Number Pin Name Type(1) Port 57 PMTXC O 5 PHY[5] MII transmit clock. PHY mode MII. 55 PMTXD0 Ipd 5 PHY[5] MII transmit bit 0. 54 PMTXD1 Ipd 5 PHY[5] MII transmit bit 1. 53 PMTXD2 Ipd 5 PHY[5] MII transmit bit 2. 52 PMTXD3 Ipd 5 PHY[5] MII transmit bit 3. 51 PMTXEN Ipd 5 PHY[5] MII transmit enable. 5 PHY[5] MII transmit error. Note: 1. Pin Function 56 PMTXER Ipd 114 PS0 Ipd Serial bus configuration pin. See “Pin 113.” 113 PS1 Ipd Serial bus configuration pin. If EEPROM is not present, the KS8995MA/FQ will start itself with chip default (00)... Pin Configuration Serial Bus Configuration PS[1:0]=00 I2C Master Mode for EEPROM PS[1:0]=01 Reserved PS[1:0]=10 SPI Slave Mode for CPU Interface PS[1:0]=11 Factory Test Mode (BIST) 47 PWRDN_N Ipu Full-chip power down. Active low. 48 RESERVE NC Reserved pin. No connect. 115 RST_N Ipu 5 RXM1 I 1 Physical receive signal – (differential). 11 RXM2 I 2 Physical receive signal – (differential). 20 RXM3 I 3 Physical receive signal – (differential). 26 RXM4 I 4 Physical receive signal – (differential). 33 RXM5 I 5 Physical receive signal – (differential). 4 RXP1 I 1 Physical receive signal + (differential). 10 RXP2 I 2 Physical receive signal + (differential). 19 RXP3 I 3 Physical receive signal + (differential). 25 RXP4 I 4 Physical receive signal + (differential). 32 RXP5 I 5 Physical receive signal + (differential). 119 SCANEN Ipd 84 SCOL Ipd/O Switch MII collision detect. 87 SCONF0 Ipd Dual MII configuration pin. Reset the KS8995MA/FQ. Active low. NC for normal operation. Factory test pin. P = Power supply. I = Input. O = Output. I/O = Bidirectional. GND = Ground. Ipu = Input w/internal pull-up. Ipd = Input w/internal pull-down. Ipd/O = Input w/internal pull-down during reset, output pin otherwise. Ipu/O = Input w/internal pull-up during reset, output pin otherwise. NC = No connect. October 2011 22 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Pin Description − By Name Pin Number Pin Name Type(1) 86 SCONF1 Ipd Port Pin Function(2) Dual MII configuration pin. For the Switch MII, KSZ8995MA supports both MAC mode and PHY mode, KSZ8995FQ supports PHY mode only. Pin# (91, 86, 87): 85 SCRS Ipd/O 78 SMRXC I/O Switch MII PHY [5] MII 000 Disable, Otri Disable, Otri 001 PHY Mode MII Disable, Otri 010 MAC Mode MII Disable, Otri 011 PHY Mode SNI Disable, Otri 100 Disable Disable 101 PHY Mode MII PHY Mode MII 110 MAC Mode MII PHY Mode MII 111 PHY Mode SNI PHY Mode MII Switch mode carrier sense. Switch MII receive clock. Input in MAC mode, output in PHY mode MII. Switch MII receive bit 0; Strap option: LED mode PD (default) = mode 0; PU = mode 1. See “Register 11.” 83 Notes: 1. 2. SMRXD0 Ipd/O Mode 0 Mode 1 LEDX_2 Lnk/Act 100Lnk/Act LEDX_1 Fulld/Col 10Lnk/Act LEDX_0 Speed Full duplex 82 SMRXD1 Ipd/O Switch MII receive bit 1. Strap option: PD (default) = Switch MII in 100Mbps mode; PU = Switch MII in 10Mbps mode. 81 SMRXD2 Ipd/O Switch MII receive bit 2. Strap option: PD (default) = Switch MII in full-duplex mode; PU = Switch MII in half-duplex mode. 80 SMRXD3 Ipd/O Switch MII receive bit 3. Strap option: PD (default) = Disable Switch MII full-duplex flow control; PU = Enable Switch MII full-duplex flow control. 79 SMRXDV Ipd/O Switch MII receive data valid. 75 SMTXC I/O Switch MII transmit clock. Input in MAC mode, output in PHY mode MII. 73 SMTXD0 Ipd Switch MII transmit bit 0. 72 SMTXD1 Ipd Switch MII transmit bit 1. 71 SMTXD2 Ipd Switch MII transmit bit 2. 70 SMTXD3 Ipd Switch MII transmit bit 3. 69 SMTXEN Ipd Switch MII transmit enable. 74 SMTXER Ipd Switch MII transmit error. P = Power supply. I = Input. O = Output. I/O = Bidirectional. GND = Ground. Ipu = Input w/internal pull-up. Ipd = Input w/internal pull-down. Ipd/O = Input w/internal pull-down during reset, output pin otherwise. Ipu/O = Input w/internal pull-up during reset, output pin otherwise. Otri = Output tristated. NC = No connect. PU = Strap pin pull-up. PD = Strap pull-down. Fulld = Full duplex October 2011 23 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Pin Description − By Name Pin Number Pin Name Type(1) Port 110 SPIC/SCL I/O All (1) Input clock up to 5MHz in SPI slave mode; (2) output clock at 61kHz in I2C master mode. See “Pin 113.” 111 SSPID/SDA I/O All (1) Serial data input in SPI slave mode; (2) serial data input/output in I2C master mode. See “Pin 113.” 109 SPIQ Otri All (1) SPI serial data output in SPI slave mode; (2) output clock at 61kHz in I2C master mode. See “Pin 113.” 112 SPIS_N Ipu All Active low. (1) SPI data transfer start in SPI slave mode. When SPIS_N is high, the KS8995MA/FQ is deselected and SPIQ is held in high impedance state, a high-to-low transition to initiate the SPI data transfer; (2) not used in I2C master mode. 128 TEST2 NC NC for normal operation. Factory test pin. 118 TESTEN Ipd NC for normal operation. Factory test pin. 8 TXM1 O 1 Physical transmit signal – (differential). 14 TXM2 O 2 Physical transmit signal – (differential). 23 TXM3 O 3 Physical transmit signal – (differential). 29 TXM4 O 4 Physical transmit signal – (differential). 36 TXM5 O 5 Physical transmit signal – (differential). Note: 1. Pin Function 7 TXP1 O 1 Physical transmit signal + (differential). 13 TXP2 O 2 Physical transmit signal + (differential). 22 TXP3 O 3 Physical transmit signal + (differential). 28 TXP4 O 4 Physical transmit signal + (differential). 35 TXP5 O 5 Physical transmit signal + (differential). 123 VDDAP P 1.8V analog VDD for PLL. 41 VDDAR P 1.8V analog VDD. 43 VDDAR P 1.8V analog VDD. 3 VDDAR P 1.8V analog VDD. 15 VDDAR P 1.8V analog VDD. 31 VDDAR P 1.8V analog VDD. 125 VDDAR P 1.8V analog VDD. 18 VDDAT P 3.3V analog VDD. 9 VDDAT P 3.3V analog VDD. 24 VDDAT P 3.3V analog VDD. 37 VDDAT P 3.3V analog VDD. 50 VDDC P 1.8V digital core VDD. P = Power supply. I = Input. O = Output. I/O = Bidirectional. GND = Ground. Ipu = Input w/internal pull-up. Ipd = Input w/internal pull-down. Ipd/O = Input w/internal pull-down during reset, output pin otherwise. Ipu/O = Input w/internal pull-up during reset, output pin otherwise. Otri = Output tristated. NC = No connect. October 2011 24 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Pin Description − By Name Pin Number Pin Name Type(1) 89 VDDC P 117 VDDC P 1.8V digital core VDD. 59 VDDIO P 3.3V digital VDD for digital I/O circuitry. 77 VDDIO P 3.3V digital VDD for digital I/O circuitry. 100 VDDIO P 3.3V digital VDD for digital I/O circuitry. 121 X1 I 25MHz crystal clock connection/or 3.3V tolerant oscillator input. Oscillator should be ±50ppm. 122 X2 O 25MHz crystal clock connection. Note: 1. Port Pin Function 1.8V digital core VDD. P = Power supply. I = Input. O = Output. October 2011 25 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Introduction The KS8995MA/FQ contains five 10/100 physical layer transceivers and five media access control (MAC) units with an integrated Layer 2 managed switch. The device runs in three modes. The first mode is as a five-port integrated switch. The second is as a five-port switch with the fifth port decoupled from the physical port. In this mode, access to the fifth MAC is provided through a media independent interface (MII). This is useful for implementing an integrated broadband router. The third mode uses the dual MII feature to recover the use of the fifth PHY. This allows the additional broadband gateway configuration, where the fifth PHY may be accessed through the MII-P5 port. The KS8995MA/FQ has the flexibility to reside in a managed or unmanaged design. In a managed design, a host processor has complete control of the KS8995MA/FQ via the SPI bus, or partial control via the MDC/MDIO interface. An unmanaged design is achieved through I/O strapping or EEPROM programming at system reset time. On the media side, the KS8995MA/FQ supports IEEE 802.3 10BASE-T, 100BASE-TX on all ports, and the KS8995MA supports 100BASE-FX on ports 4 and 5, and the KS8995FQ supports 100BASE-FX on ports 3 and 4. The KS8995MA/FQ can be used as fully-managed 5-port standalone switch or two separate media converters. Physical signal transmission and reception are enhanced through the use of patented analog circuitry that makes the design more efficient and allows for lower power consumption and smaller chip die size. The major enhancements from the KS8995E to the KS8995MA/FQ are support for host processor management, a dual MII interface, tag as well as port based VLAN, spanning tree protocol support, IGMP snooping support, port mirroring support and rate limiting functionality. Functional Overview: Physical Layer Transceiver 100BASE-TX Transmit The 100BASE-TX transmit function performs parallel-to-serial conversion, 4B/5B coding, scrambling, NRZ-to-NRZI conversion, MLT3 encoding and transmission. The circuit starts with a parallel-to-serial conversion, which converts the MII data from the MAC into a 125MHz serial bit stream. The data and control stream is then converted into 4B/5B coding followed by a scrambler. The serialized data is further converted from NRZ-to-NRZI format, and then transmitted in MLT3 current output. The output current is set by an external 1% 3.01kΩ resistor for the 1:1 transformer ratio. It has a typical rise/fall time of 4ns and complies with the ANSI TP-PMD standard regarding amplitude balance, overshoot, and timing jitter. The wave-shaped 10BASE-T output is also incorporated into the 100BASE-TX transmitter. 100BASE-TX Receive The 100BASE-TX receiver function performs adaptive equalization, DC restoration, MLT3-to-NRZI conversion, data and clock recovery, NRZI-to-NRZ conversion, de-scrambling, 4B/5B decoding, and serial-to-parallel conversion. The receiving side starts with the equalization filter to compensate for inter-symbol interference (ISI) over the twisted pair cable. Since the amplitude loss and phase distortion is a function of the length of the cable, the equalizer has to adjust its characteristics to optimize the performance. In this design, the variable equalizer will make an initial estimation based on comparisons of incoming signal strength against some known cable characteristics, then tunes itself for optimization. This is an ongoing process and can self-adjust against environmental changes such as temperature variations. The equalized signal then goes through a DC restoration and data conversion block. The DC restoration circuit is used to compensate for the effect of baseline wander and improve the dynamic range. The differential data conversion circuit converts the MLT3 format back to NRZI. The slicing threshold is also adaptive. The clock recovery circuit extracts the 125MHz clock from the edges of the NRZI signal. This recovered clock is then used to convert the NRZI signal into the NRZ format. The signal is then sent through the de-scrambler followed by the 4B/5B decoder. Finally, the NRZ serial data is converted to the MII format and provided as the input data to the MAC. PLL Clock Synthesizer The KS8995MA/FQ generates 125MHz, 42MHz, 25MHz, and 10MHz clocks for system timing. Internal clocks are generated from an external 25MHz crystal or oscillator. October 2011 26 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Scrambler/De-Scrambler (100BASE-TX Only) The purpose of the scrambler is to spread the power spectrum of the signal in order to reduce EMI and baseline wander. The data is scrambled through the use of an 11-bit wide linear feedback shift register (LFSR). This can generate a 2047bit non-repetitive sequence. The receiver will then de-scramble the incoming data stream with the same sequence at the transmitter. 100BASE-FX Operation 100BASE-FX operation is very similar to 100BASE-TX operation except that the scrambler/de-scrambler and MLT3 encoder/decoder are bypassed on transmission and reception. In this mode the auto-negotiation feature is bypassed since there is no standard that supports fiber auto-negotiation. 100BASE-FX Signal Detection The physical port runs in 100BASE-FX mode if FXSDx >0.6V for ports 3, 4 (KSZ8995FQ) or ports 4, 5 (KSZ8995MA) only. This signal is internally referenced to 1.25V. The fiber module interface should be set by a voltage divider such that FXSDx ‘H’ is above this 1.25V reference, indicating signal detect, and FXSDx ‘L’ is below the 1.25V reference to indicate no signal. When FXSDx is below 0.6V then 100BASE-FX mode is disabled. Since there is no auto-negotiation for 100BASE-FX mode, the ports must be forced to either full or half-duplex for the fiber ports. Note that strap-in options exist to set duplex mode for port 4, but not for port 3, 5. 100BASE-FX Far End fault far end fault occurs when the signal detection is logically false from the receive fiber module. When this occurs, the transmission side signals the other end of the link by sending 84 1s followed by a zero in the idle period between frames. The far end fault may be disabled through register settings. 10BASE-T Transmit The output 10BASE-T driver is incorporated into the 100BASE-T driver to allow transmission with the same magnetics. They are internally wave-shaped and pre-emphasized into outputs with a typical 2.3V amplitude. The harmonic contents are at least 27dB below the fundamental when driven by an all-ones Manchester-encoded signal. 10BASE-T Receive On the receive side, input buffer and level detecting squelch circuits are employed. A differential input receiver circuit and a PLL perform the decoding function. The Manchester-encoded data stream is separated into clock signal and NRZ data. A squelch circuit rejects signals with levels less than 400mV or with short pulsewidths in order to prevent noises at the RXP or RXM input from falsely triggering the decoder. When the input exceeds the squelch limit, the PLL locks onto the incoming signal and the KS8995MA/FQ decodes a data frame. The receiver clock is maintained active during idle periods in between data reception. Power Management The KS8995MA/FQ features a per port power down mode. To save power the user can power down ports that are not in use by setting port control registers or MII control registers. In addition, it also supports full chip power down mode. When activated, the entire chip will be shutdown. MDI/MDI-X Auto Crossover The KS8995MA/FQ supports MDI/MDI-X auto crossover. This facilitates the use of either a straight connection CAT-5 cable or a crossover CAT-5 cable. The auto-sense function will detect remote transmit and receive pairs, and correctly assign the transmit and receive pairs from the Micrel device. This can be highly useful when end users are unaware of cable types and can also save on an additional uplink configuration connection. The auto crossover feature may be disabled through the port control registers. October 2011 27 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Auto-Negotiation The KS8995MA/FQ conforms to the auto-negotiation protocol as described by the 802.3 committee. Auto-negotiation allows unshielded twisted pair (UTP) link partners to select the best common mode of operation. In auto-negotiation the link partners advertise capabilities across the link to each other. If auto-negotiation is not supported or the link partner to the KS8995MA/FQ is forced to bypass auto-negotiation, then the mode is set by observing the signal at the receiver. This is known as parallel mode because while the transmitter is sending auto-negotiation advertisements, the receiver is listening for advertisements or a fixed signal protocol. The flow for the link setup is shown in Figure 5. Figure 5. Auto Negotiation October 2011 28 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Functional Overview: Switch Core Address Look-Up The internal look-up table stores MAC addresses and their associated information. It contains a 1K unicast address table plus switching information. The KS8995MA/FQ is guaranteed to learn 1K addresses and distinguishes itself from a hashbased look-up table, which depending on the operating environment and probabilities, may not guarantee the absolute number of addresses it can learn. Learning The internal look-up engine updates its table with a new entry if the following conditions are met: • The received packet’s source address (SA) does not exist in the look-up table. • The received packet is good; the packet has no receiving errors and is of legal length. The look-up engine inserts the qualified SA into the table, along with the port number and time stamp. If the table is full, the last entry of the table is deleted first to make room for the new entry. Migration The internal look-up engine also monitors whether a station is moved. If this occurs, it updates the table accordingly. Migration happens when the following conditions are met: • The received packet’s SA is in the table but the associated source port information is different. • The received packet is good; the packet has no receiving errors and is of legal length. The look-up engine will update the existing record in the table with the new source port information. Aging The look-up engine will update the time stamp information of a record whenever the corresponding SA appears. The time stamp is used in the aging process. If a record is not updated for a period of time, the look-up engine will remove the record from the table. The look-up engine constantly performs the aging process and will continuously remove aging records. The aging period is 300 + 75 seconds. This feature can be enabled or disabled through Register 3 or by external pull-up or pull-down resistors on LED[5][2]. See “Register 3” section. Forwarding The KS8995MA/FQ will forward packets using an algorithm that is depicted in the following flowcharts. Figure 6 shows stage one of the forwarding algorithm where the search engine looks up the VLAN ID, static table, and dynamic table for the destination address, and comes up with “port to forward 1” (PTF1). PTF1 is then further modified by the spanning tree, IGMP snooping, port mirroring, and port VLAN processes to come up with “port to forward 2” (PTF2), as shown in Figure 7. This is where the packet will be sent. KS8995MA/FQ Will Not Forward the Following Packets • Error packets. These include framing errors, FCS errors, alignment errors, and illegal size packet errors. • 802.3x pause frames. The KS8995MA/FQ will intercept these packets and perform the appropriate actions. • “Local” packets. Based on destination address (DA) look-up. If the destination port from the look-up table matches the port where the packet was from, the packet is defined as “local.” Switching Engine The KS8995MA/FQ features a high-performance switching engine to move data to and from the MAC’s, packet buffers. It operates in store and forward mode, while the efficient switching mechanism reduces overall latency. The KS8995MA/FQ has a 64kB internal frame buffer. This resource is shared between all five ports. The buffer sharing mode can be programmed through Register 2. See “Register 2.” In one mode, ports are allowed to use any free buffers in the buffer pool. In the second mode, each port is only allowed to use 1/5 of the total buffer pool. There are a total of 512 buffers available. Each buffer is sized at 128B. October 2011 29 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Media Access Controller (MAC) Operation The KS8995MA/FQ strictly abides by IEEE 802.3 standards to maximize compatibility. Inter-Packet Gap (IPG) If a frame is successfully transmitted, the 96-bit time IPG is measured between the two consecutive MTXEN. If the current packet is experiencing collision, the 96-bit time IPG is measured from MCRS and the next MTXEN. Backoff Algorithm The KS8995MA/FQ implements the IEEE Std. 802.3 binary exponential back-off algorithm, and optional “aggressive mode” back off. After 16 collisions, the packet will be optionally dropped depending on the chip configuration in Register 3. See “Register 3.” Late Collision If a transmit packet experiences collisions after 512-bit times of the transmission, the packet will be dropped. Illegal Frames The KS8995MA/FQ discards frames less than 64 bytes and can be programmed to accept frames up to 1536 bytes in Register 4. For special applications, the KS8995MA/FQ can also be programmed to accept frames up to 1916 bytes in Register 4. Since the KS8995MA/FQ supports VLAN tags, the maximum sizing is adjusted when these tags are present. Flow Control The KS8995MA/FQ supports standard 802.3x flow control frames on both transmit and receive sides. On the receive side, if the KS8995MA/FQ receives a pause control frame, the KS8995MA/FQ will not transmit the next normal frame until the timer, specified in the pause control frame, expires. If another pause frame is received before the current timer expires, the timer will be updated with the new value in the second pause frame. During this period (being flow controlled), only flow control packets from the KS8995MA/FQ will be transmitted. On the transmit side, the KS8995MA/FQ has intelligent and efficient ways to determine when to invoke flow control. The flow control is based on availability of the system resources, including available buffers, available transmit queues and available receive queues. The KS8995MA/FQ flow controls a port that has just received a packet if the destination port resource is busy. The KS8995MA/FQ issues a flow control frame (XOFF), containing the maximum pause time defined in IEEE standard 802.3x. Once the resource is freed up, the KS8995MA/FQ sends out the other flow control frame (XON) with zero pause time to turn off the flow control (turn on transmission to the port). A hysteresis feature is also provided to prevent over-activation and deactivation of the flow control mechanism. The KS8995MA/FQ flow controls all ports if the receive queue becomes full. October 2011 30 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Figure 6. DA Look-Up Flowchart − 1 October 2011 31 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Figure 7. DA Resolution Flowchart − Stage 2 October 2011 32 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Half-Duplex Back Pressure The KS8995MA/FQ also provides a half-duplex back-pressure option (Note: this is not in IEEE 802.3 standards). The activation and deactivation conditions are the same as the ones given for full-duplex mode. If back pressure is required, the KS8995MA/FQ sends preambles to defer the other station's transmission (carrier sense deference). To avoid jabber and excessive deference as defined in IEEE 802.3 standard, after a certain period of time, the KS8995MA/FQ discontinues carrier sense but raises it quickly after it drops packets to inhibit other transmissions. This short silent time (no carrier sense) is to prevent other stations from sending out packets and keeps other stations in a carrier sense deferred state. If the port has packets to send during a back pressure situation, the carrier-sense-type back pressure is interrupted and those packets are transmitted instead. If there areno more packets to send, carrier-sense-type back pressure becomes active again until switch resources are free. If a collision occurs, the binary exponential backoff algorithm is skipped and carrier sense is generated immediately, reducing the chanceof further colliding and maintaining carrier sense to prevent reception of packets. To ensure no packet loss in 10BASE-T or 100BASE-TX half-duplex modes, the user must enable the following: • Aggressive backoff (Register 3, Bit 0) • No excessive collision drop (Register 4, Bit 3) • Back pressure (Register 4, Bit 5) These bits are not set as the default because this is not the IEEE standard. Broadcast Storm Protection The KS8995MA/FQ has an intelligent option to protect the switch system from receiving too many broadcast packets. Broadcastpackets are normally forwarded to all ports except the source port and thus use too many switch resources (bandwidth and available space in transmit queues). The KS8995MA/FQ has the option to include “multicast packets” for storm control. The broadcast storm rate parameters are programmed globally and can be enabled or disabled on a per port basis. The rate is basedon a 50ms interval for 100BT and a 500ms interval for 10BT. At the beginning of each interval, the counter is cleared to zero and the rate limit mechanism starts to count the number of bytes during the interval. The rate definition is described in Registers 6 and 7. The default setting for Registers 6 and 7 is 0x4A (74 decimal). This is equal to a rate of 1%, calculated as follows: 148,800 frames/sec × 50ms/interval × 1% = 74 frames/interval (approximately) = 0×4A frames/interval MII Interface Operation The media independent interface (MII) is specified by the IEEE 802.3 committee and provides a common interface between physical layer and MAC layer devices. The KS8995MA/FQ provides two such interfaces. The MII-P5 interface is used to connectto the fifth PHY, whereas the MII-SW interface is used to connect to the fifth MAC. Each of these MII interfaces contains two distinct groups of signals, one for transmission and the other for receiving. Table 1 describes the signals used in the MII-P5 interface. October 2011 33 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ SNI Signal Description KS8995MA/FQ Signal MTXEN Transmit Enable PMTXEN MTXER Transmit Error PMTXER MTXD3 Transmit Data Bit 3 PMTXD[3] MTXD2 Transmit Data Bit 2 PMTXD[2] MTXD1 Transmit Data Bit 1 PMTXD[1] MTXD0 Transmit Data Bit 0 PMTXD[0] MTXC Transmit Clock PMTXC MCOL Collision Detection PCOL MCRS Carrier Sense PCRS MRXDV Receive Data Valid PMRXDV MRXER Receive Error PMRXER MRXD3 Receive Data Bit 3 PMRXD[3] MRXD2 Receive Data Bit 2 PMRXD[2] MRXD1 Receive Data Bit 1 PMRXD[1] MRXD0 Receive Data Bit 0 PMRXD[0] MRXC Receive Clock PMRXC MDC Management Data Clock MDC MDIO Management Data I/O MDIO Table 1. MII − P5 Signals (PHY Mode) Table 2 illustrates three different connection approaches: 1. The first and second columns show the connections for external MAC and MII-SW PHY mode. 2. The fourth and fifth columns show the connections for external PHY and MII-SW MAC mode. 3. The second and fifth columns show the back-to-back connections for two MII-SW MACs of two devices. October 2011 34 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ PHY Mode Connection MAC Mode Connection External MAC KS8995MA/FQ Signal Description External PHY KS8995MA Only Signal MTXEN SMTXEN Transmit enable MTXEN SMRXDV MTXER SMTXER Transmit error MTXER Not used MTXD3 SMTXD[3] Transmit data bit 3 MTXD3 SMRXD[3] MTXD2 SMTXD[2] Transmit data bit 2 MTXD2 SMRXD[2] MTXD1 SMTXD[1] Transmit data bit 1 MTXD1 SMRXD[1] MTXD0 SMTXD[0] Transmit data bit 0 MTXD0 SMRXD[0] MTXC SMTXC Transmit clock MTXC SMRXC MCOL SCOL Collision detection MCOL SCOL MCRS SCRS Carrier sense MCRS SCRS MRXDV SMRXDV Receive data valid MRXDV SMTXEN MRXER Not used Receive error MRXER SMTXER MRXD3 SMRXD[3] Receive data bit 3 MRXD3 SMTXD[3] MRXD2 SMRXD[2] Receive data bit 2 MRXD2 SMTXD[2] MRXD1 SMRXD[1] Receive data bit 1 MRXD1 SMTXD[1] MRXD0 SMRXD[0] Receive data bit 0 MRXD0 SMTXD[0] MRXC SMRXC Receive clock MRXC SMTXC Table 2. MII − SW Signals The MII-P5 interface operates in PHY mode only, while the MII-SW interface operates in either MAC mode or PHY mode for KSZ8995MA. The MII-SW interface operates in PHY mode only for KSZ8995FQ. These interfaces are nibble-wide data interfaces and therefore run at 1/4 the network bit rate (not encoded). Additional signals on the transmit side indicate when data is valid or when an error occurs during transmission. Likewise, the receive side has indicators that convey when the data is valid and without physical layer errors. For half-duplex operation there is a signal that indicates a collision has occurred during transmission. Note that the signal MRXER is not provided on the MII-SW interface for PHY mode operation and the signal MTXER is not provided on the MII-SW interface for MAC mode operation. Normally MRXER would indicate a receive error coming from the physical layer device. MTXER would indicate a transmit error from the MAC device. These signals are not appropriate for this configuration. For PHY mode operation, if the device interfacing with the KS8995MA/FQ has an MRXER pin, it should be tied low. For MAC mode operation, if the device interfacing with the KS8995MA has an MTXER pin, it should be tied low. October 2011 35 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ SNI Interface Operation The serial network interface (SNI) is compatible with some controllers used for network layer protocol processing. This interface can be directly connected to these types of devices. The signals are divided into two groups, one for transmission and the other for reception. The signals involved are described in Table 3. SNI Signal Description KS8995MA/FQ Signal TXEN Transmit Enable SMTXEN TXD Serial Transmit Data SMTXD[0] TXC Transmit Clock SMTXC COL Collision Detection SCOL CRS Carrier Sense SMRXDV RXD Serial Receive Data SMRXD[0] RXC Receive Clock SMRXC Table 3. SNI Signals This interface is a bit-wide data interface and therefore runs at the network bit rate (not encoded). An additional signal on the transmit side indicates when data is valid. Likewise, the receive side has an indicator that conveys when the data is valid. For half-duplex operation there is a signal that indicates a collision has occurred during transmission. Advanced Functionality Spanning Tree Support Port 5 is the designated port for spanning tree support. The other ports (Port 1 – Port 4) can be configured in one of the five spanning tree states via “transmit enable,” “receive enable,” and “learning disable” register settings in Registers 18, 34, 50, and 66 for Ports 1, 2, 3, and 4, respectively. The following description shows the port setting and software actions taken for each of the five spanning tree states. Disable state: the port should not forward or receive any packets. Learning is disabled. Port setting: "transmit enable = 0, receive enable = 0, learning disable = 1." Software action: the processor should not send any packets to the port. The switch may still send specific packets to the processor (packets that match some entries in the static table with “overriding bit” set) and the processor should discard those packets. Note: processor is connected to port 5 via MII interface. Address learning is disabled on the port in this state. Blocking state: only packets to the processor are forwarded. Learning is disabled. Port setting: "transmit enable = 0, receive enable = 0, learning disable = 1" Software action: the processor should not send any packets to the port(s) in this state. The processor should program the “Static MAC table” with the entries that it needs to receive (e.g., BPDU packets). The “overriding” bit should also be set so that the switch will forward those specific packets to the processor. Address learning is disabled on the port in this state. Listening state: only packets to and from the processor are forwarded. Learning is disabled. Port setting: "transmit enable = 0, receive enable = 0, learning disable = 1. "Software action: The processor should program the static MAC table with the entries that it needs to receive (e.g. BPDU packets). The “overriding” bit should be set so that the switch will forward those specific packets to the processor. The processor may send packets to the port(s) in this state, see “Special Tagging Mode” section for details. Address learning is disabled on the port in this state. October 2011 36 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Learning state: only packets to and from the processor are forwarded. Learning is enabled. Port setting: “transmit enable = 0, receive enable = 0, learning disable = 0.” Software action: The processor should program the static MAC table with the entries that it needs to receive (e.g., BPDU packets). The “overriding” bit should be set so that the switch will forward those specific packets to the processor. The processor may send packets to the port(s) in this state, see “Special Tagging Mode” section for details. Address learning is enabled on the port in this state. Forwarding state: packets are forwarded and received normally. Learning is enabled. Port setting: “transmit enable = 1, receive enable = 1, learning disable = 0.” Software action: The processor should program the static MAC table with the entries that it needs to receive (e.g., BPDU packets). The “overriding” bit should be set so that the switch will forward those specific packets to the processor. The processor may send packets to the port(s) in this state, see “Special Tagging Mode” section for details. Address learning is enabled on the port in this state. Special Tagging Mode The special tagging mode is designed for spanning tree protocol IGMP snooping and is flexible for use in other applications. The special tagging mode, similar to 802.1q, requires software to change network drivers to insert/modify/strip/interpret the special tag. This mode is enabled by setting both Register 11 Bit 0 and Register 80 Bit 2. 802.1q Tag Format TPID (tag protocol identifier, 0x8100) + TCI Special Tag Format STPID (special tag identifier, 0x8100) + TCI 0x810 + 4 bit for “port mask”) + TCI Table 4. Special Tagging Mode Format The STPID will only be seen and used on the port 5 interface, which should be connected to a processor. Packets from the processor to the switch should be tagged with STPID and the port mask defined as below: “0001” packet to Port 1 only “0010” packet to Port 2 only“0100” packet to Port 3 only “1000” packet to Port 4 only “0011” packet broadcast to Port 1 and Port 2 ...... “1111” packet broadcast to Ports 1, 2, 3, and 4. “0000” normal tag, will use the KS8995MA/FQ internal look-up result. Normal packets should use this setting. If packets from the processors do not have a tag, the KS8995MA/FQ will treat them as normal packets and an internal look-up will be performed.The KS8995MA/FQ uses a non-zero “port mask” to bypass the look-up result and override any port setting, regardless of port states (blocking, disable, listening, learning). Table 5 shows the egress rules when dealing with STPID. October 2011 37 M9999-102611-3.0 Micrel, Inc. Ingress Tag Field (0x810+ Port Mask) (0x810+ Port Mask) (0x810+ Port Mask) (0x810+ Port Mask) Not Tagged KS8995MA/FQ Tx Port “Tag Insertion” 0 Tx Port “Tag Removal” 0 0 1 1 0 1 1 Don’t Care Don’t Care Egress Action to Tag Field • Modify tag field to 0x8100. • Recalculate CRC. • No change to TCI if not null VID. • Replace VID with ingress (port 5) port VID if null VID. • (STPID + TCI) will be removed. • Padding to 64 bytes if necessary. • Recalculate CRC. • Modify tag field to 0x8100. • Recalculate CRC. • No change to TCI if not null VID. • Replace VID with ingress (port 5) port VID if null VID. • Modify tag field to 0x8100. • Recalculate CRC. • No change to TCI if not null VID. • Replace VID with ingress (port 5) port VID if null VID. Determined by the dynamic MAC address table. Table 5. STPID Egress Rules (Processor to Switch Port 5) For packets from regular ports (Port 1 − Port 4) to Port 5, the port mask is used to tell the processor which port the packet was received on, defined as: “0001” from Port 1, “0010” from Port 2, “0100” from Port 3, “1000” from Port 4 No values other than the previous four defined should be received in this direction in the special mode. Table 6 shows the egress rule for this direction. Ingress Packets Tagged with 0x8100 + TCI Not Tagged Egress Action to Tag Field • • • • • • • Modify TPID to 0x810 + “port mask,” which indicate source port. No change to TCI, if VID is not null. Replace null VID with ingress port VID. Recalculate CRC. Insert TPID to 0x810 + “port mask,” which indicate source port. Insert TCI with ingress port VID. Recalculate CRC. Table 6. STPID Egress Rules (Switch to Processor) October 2011 38 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ IGMP Support There are two parts involved to support IGMP in Layer 2. The first part is “IGMP” snooping. The switch will trap IGMP packets and forward them only to the processor port. The IGMP packets are identified as IP packets (either Ethernet IP packets or IEEE 802.3 SNAP IP packets) AND IP version = 0x4 AND protocol number = 0x2. The second part is “multicast address insertion” in the static MAC table. Once the multicast address is programmed in the static MAC table, the multicast session will be trimmed to the subscribed ports, instead of broadcasting to all ports. To enable this feature, set Register 5 Bit 6 to 1. Also “special tag mode” needs to be enabled, so that the processor knows which port the IGMP packet was received on. Enable “special tag mode” by setting both Register 11 Bit 0 and Register 80 Bit 2. Port Mirroring Support KS8995MA/FQ supports “port mirror” comprehensively as: 1. “Receive Only” mirror on a port. All the packets received on the port will be mirrored on the sniffer port. For example, Port 1 is programmed to be “rx sniff,” and Port 5 is programmed to be the “sniffer port.” A packet, received on Port 1, is destined to Port 4 after the internal look-up. The KS8995MA/FQ will forward the packet to both Port 4 and Port 5. KS8995MA/FQ can optionally forward even “bad” received packets to Port 5. 2. “Transmit Only” mirror on a port. All the packets transmitted on the port will be mirrored on the sniffer port. For example, Port 1 is programmed to be “tx sniff,” and Port 5 is programmed to be the “sniffer port.” A packet, received on any of the ports, is destined to port 1 after the internal look-up. The KS8995MA/FQ will forward the packet to both Ports 1 and 5. 3. “Receive and Transmit” mirror on two ports. All the packets received on Port A AND transmitted on Port B will be mirrored on the sniffer port. To turn on the “AND” feature, set Register 5 Bit 0 to 1. For example, port 1 is programmed to be “rx sniff,” Port 2 is programmed to be “transmit sniff,” and port 5 is programmed to be the “sniffer port.” A packet, received on port 1, is destined to port 4 after the internal look-up. The KS8995MA/FQ will forward the packet to port 4 only, since it does not meet the “AND” condition. A packet, received on Port 1, is destined to Port 2 after the internal look-up. The KS8995MA/FQ will forward the packet to both Port 2 and Port 5. Multiple ports can be selected to be “rx sniffed” or “tx sniffed.” And any port can be selected to be the “sniffer port.” All these per port features can be selected through Register 17. October 2011 39 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ VLAN Support KS8995MA/FQ supports 16 active VLANs out of 4096 possible VLANs specified in IEEE 802.1q. KS8995MA/FQ provides a 16-entry VLAN table, which converts VID (12 bits) to FID (4 bits) for address look-up. If a non-tagged or null-VID-tagged packet is received, the ingress port VID is used for look-up. In the VLAN mode, the look-up process starts with VLAN table look-up to determine whether the VID is valid. If the VID is not valid, the packet will be dropped and its address will not be learned. If the VID is valid, FID is retrieved for further look-up. FID+DA is used to determine the destination port. FID+SA is used for learning purposes. DA Found In Static MAC Table USE FID Flag? FID Match? DA+FID Found In Dynamic MAC Table Action No Don’t Care Don’t Care No Broadcast to the membership ports defined in the VLAN table bit [20:16]. No Don’t Care Don’t Care Yes Send to the destination port defined in the dynamic MAC table bit [54:52]. Yes 0 Don’t Care Don’t Care Send to the destination port(s) defined in the static MAC table bit [52:48]. Yes 1 No No Broadcast to the membership ports defined in the VLAN table bit [20:16]. Yes 1 No Yes Send to the destination port defined in the dynamic MAC table bit [54:52]. Yes 1 Yes Don’t Care Send to the destination port(s) defined in the static MAC table bit [52:48]. Table 7. FID+DA Look-Up in the VLAN Mode SA+FID found in Dynamic MAC table Action No The SA+FID will be learned into the dynamic table. Yes Time stamp will be updated. Table 8. FID+SA Look-Up in the VLAN Mode Advanced VLAN features are also supported in KS8995MA/FQ, such as “VLAN ingress filtering” and “discard non PVID” defined in Register 18 Bit 6 and Bit 5. These features can be controlled on a port basis. Rate Limit Support KS8995MA/FQ supports hardware rate limiting on “receive” and “transmit” independently on a per port basis. It also supports rate limiting in a priority or non-priority environment. The rate limit starts from 0Kbps and goes up to the line rate in steps of 32Kbps. The KS8995MA/FQ uses one second as an interval. At the beginning of each interval, the counter is cleared to zero, and the rate limit mechanism starts to count the number of bytes during this interval. For receive, if the number of bytes exceeds the programmed limit, the switch will stop receiving packets on the port until the “one second” interval expires. There is an option provided for flow control to prevent packet loss. If the rate limit is programmed greater than or equal to 128Kbps and the byte counter is 8K bytes below the limit, the flow control will be triggered. If the rate limit is programmed lower than 128Kbps and the byte counter is 2K bytes below the limit, the flow control will be triggered. For transmit, if the number of bytes exceeds the programmed limit, the switch will stop transmitting packets on the port until the “one second” interval expires. If priority is enabled, the KS8995MA/FQ can support different rate controls for both high priority and low priority packets. This can be programmed through Registers 21 – 27. October 2011 40 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Configuration Interface The KS8995MA/FQ can function as a managed switch or unmanaged switch. If no EEPROM or micro-controller exists, the KS8995MA/FQ will operate from its default setting. Some default settings are configured via strap in options as indicated in the following tables. Pin # Pin Name PU/PD(1) 1 MDI-XDIS Ipd 45 MUX1 NC 46 MUX2 NC Description(1) Disable auto MDI/MDI-X. PD = (default) = normal operation PU = disable auto MDI/MDI-X on all ports. Factory test pins. MUX1 and MUX2 should be left unconnected for normal operation. Mode Normal Operation MUX1 MUX2 NC NC 62 PMRXD3 Ipd/O PHY[5] MII receive bit 3. Strap option: PD (default) = enable flow control; PU = disable flow control. 63 PMRXD2 Ipd/O PHY[5] MII receive bit 2. Strap option: PD (default) = disable back pressure; PU = enable back pressure. 64 PMRXD1 Ipd/O PHY[5] MII receive bit 1. Strap option: PD (default) = drop excessive collision packets; PU = does not drop excessive collision packets. 65 PMRXD0 Ipd/O PHY[5] MII receive bit 0. Strap option: PD (default) = disable aggressive back-off algorithm in half-duplex mode; PU = enable for performance enhancement. 66 PMRXER Ipd/O PHY[5] MII receive error. Strap option: PD (default) = 1522/1518 bytes; PU = packet size up to 1536 bytes. 67 PCRS Ipd/O PHY[5] MII carrier sense/strap option for port 4 only. PD (default) = force half-duplex if auto-negotiation is disabled or fails. PU = force full-duplex if auto-negotiation is disabled or fails. Refer to register 76. 68 PCOL Ipd/O PHY[5] MII collision detect/strap option for port 4 only. PD (default) = no force flow control. PU = force flow control. Refer to register 66. 80 SMRXD3 Ipd/O Switch MII receive bit 3. Strap option: PD (default) = disable switch MII full-duplex flow control; PU = enable switch MII full-duplex flow control. 81 SMRXD2 Ipd/O Switch MII receive bit 2. Strap option: PD (default) = switch MII in full-duplex mode; PU = switch MII in half-duplex mode. 82 SMRXD1 Ipd/O Switch MII receive bit 1. Strap option: PD (default) = switch MII in 100Mbps mode; PU = switch MII in 10Mbps mode. Switch MII receive bit 0. Strap option: LED mode PD (default) = mode 0; PU = mode 1. See “Register 11.” 83 Note: 1. SMRXD0 Ipd/O Mode 0 Mode 1 LEDX_2 Lnk/Act 100Lnk/Act LEDX_1 Fulld/Col 10Lnk/Act LEDX_0 Speed Fulld NC = No connect. Ipd = Input w/internal pull-down. Ipd/O = Input w/internal pull-down during reset, output pin otherwise. Fulld = Full duplex. October 2011 41 M9999-102611-3.0 Micrel, Inc. Pin # KS8995MA/FQ Pin Name PU/PD(1) Description(1) Dual MII configuration pin. For the Switch MII, KSZ8995MA supports both MAC mode and PHY mode, KSZ8995FQ supports PHY mode only. 86 SCONF1 Ipd Pins 91, 86, 87 Switch MII PHY [5] MII 000 Disable, Otri Disable, Otri 001 PHY Mode MII Disable, Otri 010 MAC Mode MII Disable, Otri 011 PHY Mode SNI Disable, Otri 100 Disable Disable 101 PHY Mode MII PHY Mode MII 110 MAC Mode MII PHY Mode MII 111 PHY Mode SNI PHY Mode MII 87 SCONF0 Ipd Dual MII configuration pin. 90 LED5-2 Ipu/O LED indicator 2. Strap option: Aging setup. See “Aging” section PU (default) = aging enable; PD = aging disable. 91 LED5-1 Ipu/O LED indicator 1. Strap option: PU (default): enable PHY[5] MII I/F. PD: tristate all PHY[5] MII output. See “Pin 86 SCONF1.” Serial bus configuration pin. For this case, if the EEPROM is not present, the KS8995MA/FQ will start itself with the PS[1:0] =00 default register values . Pin Configuration 113 Note: 1. PS1 Ipd Serial Bus Configuration 2 PS[1:0]=00 I C Master Mode for EEPROM PS[1:0]=01 Reserved PS[1:0]=10 SPI Slave Mode for CPU Interface PS[1:0]=11 Factory Test Mode (BIST) 114 PS0 Ipd Serial bus configuration pin. See “Pin 113.” 128 TEST2 NC NC for normal operation. Factory test pin. NC = No connect. Ipd = Input w/internal pull-down. Ipd/O = Input w/internal pull-down during reset, output pin otherwise. Otri = Output tristated. October 2011 42 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ I2C Master Serial Bus Configuration If a 2-wire EEPROM exists, the KS8995MA/FQ can perform more advanced features like broadcast storm protection and rate control. The EEPROM should have the entire valid configuration data from Register 0 to Register 109 defined in the “Memory Map,” except the status registers. After reset, the KS8995MA/FQ will start to read all 110 registers sequentially from the EEPROM. The configuration access time (tprgm) is less than 15ms as shown in Figure 8. RST_N .... SCL .... SDA .... t prgm <15 ms Figure 8. KS8995MA/FQ EEPROM Configuration Timing Diagram To configure the KS8995MA/FQ with a pre-configured EEPROM use the following steps: 1. At the board level, connect Pin 110 on the KS8995MA/FQ to the SCL pin on the EEPROM. Connect pin 111 on the KS8995MA/FQ to the SDA pin on the EEPROM. 2. Set the input signals PS[1:0] (Pins 113 and 114, respectively) to “00.” This puts the KS8995MA/FQ serial bus configuration into I2C master mode. 3. Be sure the board-level reset signal is connected to the KS8995MA/FQ reset signal on Pin 115 (RST_N). 4. Program the contents of the EEPROM before placing it on the board with the desired configuration data. Note that the first byte in the EEPROM must be “95” for the loading to occur properly. If this value is not correct, all other data will be ignored. 5. Place the EEPROM on the board and power up the board. Assert the active-low board level reset to RST_N on the KS8995MA/FQ. After the reset is de-asserted, the KS8995MA/FQ will begin reading configuration data from the EEPROM. The configuration access time (tprgm) is less than 15ms. Note: For proper operation, make sure that Pin 47 (PWRDN_N) is not asserted during the reset operation. SPI Slave Serial Bus Configuration The KS8995MA/FQ can also act as an SPI slave device. Through the SPI, the entire feature set can be enabled, including “VLAN,” “IGMP snooping,” “MIB counters,” etc. The external master device can access any register from Register 0 to Register 127 randomly. The system should configure all the desired settings before enabling the switch in the KS8995MA/FQ. To enable the switch, write a "1" to Register 1 Bit 0. Two standard SPI commands are supported (00000011 for “READ DATA,” and 00000010 for “WRITE DATA”). To speed configuration time, the KS8995MA/FQ also supports multiple reads or writes. After a byte is written to or read from the KS8995MA/FQ, the internal address counter automatically increments if the SPI Slave Select Signal (SPIS_N) continues to be driven low. If SPIS_N is kept low after the first byte is read, the next byte at the next address will be shifted out on SPIQ. If SPIS_N is kept low after the first byte is written, bits on the Master Out Slave Input (SPID) line will be written to the next address. Asserting SPIS_N high terminates a read or write operation. This means that the SPIS_N signal must be asserted high and then low again before issuing another command and address. The address counter wraps back to zero once it reaches the highest address. Therefore the entire register set can be written to or read from by issuing a single command and address. The KS8995MA/FQ is able to support a 5MHz SPI bus. A high-performance SPI master is recommended to prevent internal counter overflow. October 2011 43 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ To use the KS8995MA/FQ SPI: 1. At the board level, connect KS8995MA/FQ pins as follows: KS8995MA/FQ Pin Number KS8995MA/FQ Signal Name Microprocessor Signal Description 112 SPIS_N SPI Slave Select 110 SPIC SPI Clock 111 SPID Master Out Slave Input 109 SPIQ Master In Slave Output Table 9. SPI Connections 2. Set the input signals PS[1:0] (pins 113 and 114, respectively) to “10” to set the serial configuration to SPI slave mode. 3. Power up the board and assert a reset signal. After reset wait 100µs, the start switch bit in Register 1 will be set to ‘0’. Configure the desired settings in the KS8995MA/FQ before setting the start register to ‘1.' 4. Write configuration to registers using a typical SPI write data cycle as shown in Figure 9 or SPI multiple write as shown in Figure 11. Note that data input on SPID is registered on the rising edge of SPIC. 5. Registers can be read and configuration can be verified with a typical SPI read data cycle as shown in Figure 10 or a multiple read as shown in Figure 12. Note that read data is registered out of SPIQ on the falling edge of SPIC. 6. After configuration is written and verified, write a ‘1’ to Register 1 bit 0 to begin KS8995MA/FQ operation. SPIS_N SPIC SPID X 0 0 0 0 0 0 1 0 A7 A6 A5 A4 A3 A2 A1 A0 D7 D6 D5 D4 D3 D2 D1 D0 SPIQ WRITE COMMAND WRITE ADDRESS WRITE DATA Figure 9. SPI Write Data Cycle SPIS_N SPIC SPID X 0 0 0 0 0 0 1 1 A7 A6 A5 A4 A3 SPIQ A2 A1 A0 D7 READ COMMAND READ ADDRESS D6 D5 D4 D3 D2 D1 D0 READ DATA Figure 10. SPI Read Data Cycle October 2011 44 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ SPIS_N SPIC SPID X 0 0 0 0 0 0 1 0 A7 A6 A5 A4 A3 A2 A1 A0 D7 D6 D5 D4 D3 D2 D1 D0 D2 D1 D0 SPIQ WRITE COMMAND WRITE ADDRESS Byte 1 SPIS_N SPIC SPID D7 D6 D5 D4 D4 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D7 D0 D6 D5 D4 D3 SPIQ Byte 2 Byte 3 ... Byte N Figure 11. SPI Multiple Write SPIS_N SPIC SPID X 0 0 0 0 0 0 1 1 A7 A6 A5 A4 A3 A2 A1 SPIQ READ COMMAND A0 X X X X X X X X D7 D6 D5 D4 D3 D2 D1 D0 READ ADDRESS Byte 1 SPIS_N SPIC SPID X X X X X X X X X X X X X X X X X X X X X X X X SPIQ D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 Byte 2 Byte 3 ... Byte N Figure 12. SPI Multiple Read MII Management Interface (MIIM) A standard MIIM interface is provided for all five PHY devices in the KS8995MA/FQ. An external device with MDC/MDIO capability is able to read PHY status or to configure PHY settings. The device is able to meet IEEE specification of 2.5MHz MDC clock. For details on the MIIM interface standard please reference the IEEE 802.3 specification (section 22.2.4.5). The MIIM interface does not have access to all the configuration registers in the KS8995MA/FQ. It can only access the standard MII registers. See “MIIM Registers.” The SPI interface, on the other hand, can be used to access the entire KS8995MA/FQ feature set. October 2011 45 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Register Description Offset Description Decimal Hex 0−1 0x00-0x01 Chip ID Registers 2 − 11 0x02-0x0B Global Control Registers 12 − 15 0x0C-0x0F Reserved 16 − 29 0x10-0x1D Port 1 Control Registers 30 − 31 0x1E-0x2F Port 1 Status Registers 32 − 45 0x20-0x2D Port 2 Control Registers 46 − 47 0x2E-0x2F Port 2 Status Registers 48 − 61 0x30-0x3D Port 3 Control Registers 62 − 63 0x3E-0x3F Port 3 Status Registers 64 − 77 0x40-0x4D Port 4 Control Registers 78 − 79 0x4E-0x4F Port 4 Status Registers 80 − 93 0x50-0x5D Port 5 Control Registers 94 − 95 0x5E-0x5F Port 5 Status Registers 96 − 103 0x60-0x67 TOS Priority Control Registers 104 − 109 0x68-0x6D MAC Address Registers 110 − 111 0x6E-0x6F Indirect Access Control Registers 112 − 120 0x70-0x78 Indirect Data Registers 121 − 122 0x79-0x7A Digital Testing Status Registers 123 − 124 0x7B-0x7C Digital Testing Control Registers 125 − 126 0x7D-0x7E Analog Testing Control Registers 127 0x7F October 2011 Analog Testing Status Register 46 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Global Registers Address Name Description Mode Default Family ID Chip Family. RO 0x95 Name Description Mode Default RO 0x0 Register 0 (0x00): Chip ID0 7−0 Address Register 1 (0x01): Chip ID1 / Start Switch 7−4 3−1 0 Chip ID Revision ID Start Switch 0x0 is assigned to M series. (95MA) Revision ID RO 1, start the chip when external pins (PS1, PS0) = (1,0) or (0,1). Note: in (PS1,PS0) = (0,0) mode, the chip will start automatically, after trying to read the external EEPROM. If EEPROM does not exist, the chip will use default values for all internal registers. If EEPROM is present, the contents in the EEPROM will be checked. RW The switch will check: (1) Register 0 = 0x95, (2) Register 1 [7:4] = 0x0. If this check is OK, the contents in the EEPROM will override chip register default values =0, chip will not start when external pins (PS1, PS0) = (1,0) or (0,1). Based on real chip revision. 0x02=B2, 0x03=B3, 0x04=B4, 0x05=B5, etc. 0x0 Note: (PS1, PS0) = (1,1) for Factory test only. Address Name Description Mode Default R/W 0x0 R/W 0x4 Register 2 (0x02): Global Control 0 7 Reserved Reserved. Used to classify priority for incoming 802.1q packets 6−4 802.1p Base Priority “User priority” is compared against this value ⊕ : classified as high priority. < : classified as low priority. Pin LED5-1 strap option. 3 Enable PHY MII 1, enable PHY MII-P5 interface. Note: if not enabled, the switch will tri-state all outputs. R/W Pull-down (0): isolate. Pull-up (1): Enable. Note: LED[5][1] has internal pullup. 2 Buffer Share Mode 1, buffer pool is shared by all ports. A port can use more buffer when other ports are not busy. R/W 0x1 0, a port is only allowed to use 1/5 of the buffer pool. October 2011 47 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Global Registers (Continued) Address Name Description Mode Default R/W 0 R/W 0 Register 2 (0x02): Global Control 0 1 UNH Mode 1, the switch will drop packets with 0x8808 in T/L filed, or DA=01-80C2-00-00-01. 0, the switch will drop packets qualified as “flow control” packets. 0 Address Link Change Age 1, link change from “link” to “no link” will cause fast aging (<800µs) to age address table faster. After an age cycle is complete, the age logic will return to normal (300 + 75 seconds ). Note: If any port is unplugged, all addresses will be automatically aged out. Name Description Mode Default 0 Register 3 (0x03): Global Control 1 7 Pass All Frames 1, switch all packets including bad ones. Used solely for debugging purpose. Works in conjunction with sniffer mode. R/W 6 Reserved Reserved. R/W 5 IEEE 802.3x Transmit Flow Control Disable 0, will enable transmit flow control based on AN result. 1, will not enable transmit flow control regardless of AN result. R/W R/W Pin PMRXD3 strap option. Pull-down (0): Enable Rx flow control. Pull-up (1): Disable Tx/Rx flow control. Note: PMRXD3 has internal pulldown. R/W 0 R/W Pin LED[5][2] strap option. Pull-down (0): Aging disable Pull-up (1): Aging enable. Note: LED[5][2] has internal pull up. 0, will enable receive flow control based on AN result. 4 3 2 IEEE 802.3x Receive Flow Control Disable Frame Length Field Check Aging Enable October 2011 1, will not enable receive flow control regardless of AN result. 0 Pin PMRXD3 strap option. Pull-down(0): Enable Tx flow control. Pull-up(1): Disable Tx/Rx flow control. Note: PMRXD3 has internal pulldown. Note: Bit 5 and bit 4 default values are controlled by the same pin, but they can be programmed independently. 1, will check frame length field in the IEEE packets. If the actual length does not match, the packet will be dropped (for L/T <1500) . 1, Enable age function in the chip. 0, Disable aging function. 48 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Global Registers (Continued) Address 1 0 Address Name Description Fast Age Enable 1 = Turn on fast age (800µs). Mode Aggressive Back Off Enable 1 = Enable more aggressive back-off algorithm in half duplex mode to enhance performance. This is not an IEEE standard. Name Description Default R/W 0 R/W Pin PMRXD0 strap option. Pull-down (0): Disable aggressive back off. Pullup (1): Aggressive back off. Note: PMRXD0 has internal pull down. Mode Default Register 4 (0x04): Global Control 2 7 Unicast Port-VLAN Mismatch Discard 6 Multicast Storm Protection Disable 5 Back Pressure Mode 4 Flow Control and Back Pressure Fair Mode 3 No Excessive Collision Drop 2 Huge Packet Support This feature is used for port VLAN (described in Register 17, Register 33...). 1, all packets can not cross VLAN boundary. R/W 1 R/W 1 R/W 1 0, unicast packets (excluding unknown/ multicast/broadcast) can cross VLAN boundary. 1, “Broadcast Storm Protection” does not include multicast packets. Only DA=FFFFFFFFFFFF packets will be regulated. 0, “Broadcast Storm Protection” includes DA = FFFFFFFFFFFF and DA[40] = 1 packets. 1, carrier sense based backpressure is selected. 0, collision based backpressure is selected. 1, fair mode is selected. In this mode, if a flow control port and a nonflow control port talk to the same destination port, packets from the non-flow control port may be dropped. This is to prevent the flow control port from being flow controlled for an extended period of time. R/W 1 R/W Pin PMRXD1 strap option. Pull-down (0): Drop excessive collision packets. Pull-up (1): Don’t drop excessive collision packets. Note: PMRXD1 has internal pulldown. R/W 0 0, in this mode, if a flow control port and a non-flow control port talk to the same destination port, the flow control port will be flow controlled. This may not be “fair” to the flow control port. 1, the switch will not drop packets when 16 or more collisions occur. 0, the switch will drop packets when 16 or more collisions occur. 1, will accept packet sizes up to 1916 bytes (inclusive). This bit setting will override setting from bit 1 of the same register. 0, the max packet size will be determined by bit 1 of this register. October 2011 49 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Global Registers (Continued) Address Name Description Mode Default R/W Pin PMRXER strap option. Pull-down (0): 1518/1522 byte packets. Pull-up (1): 1536 byte packets. Note: PMRXER has internal pull-down. R/W 0 Mode Default R/W 0 R/W 0 R/W 0 R/W 0 R/W 00 R/W 0 R/W 0 Register 4 (0x04): Global Control 2 1, will accept packet sizes up to 1536 bytes (inclusive). 1 0 Legal Maximum Packet Size Check Disable Priority Buffer Reserve 0, 1522 bytes for tagged packets (not including packets with STPID from CPU to ports 1-4), 1518 bytes for untagged packets. Any packets larger than the specified value will be dropped. 1, each output queue is pre-allocated 48 buffers, used exclusively for high priority packets. It is recommended to enable this when priority queue feature is turned on. 0, no reserved buffers for high priority packets. Address Name Description Register 5 (0x05): Global Control 3 7 802.1q VLAN Enable 1, 802.1q VLAN mode is turned on. VLAN table needs to set up before the operation. 0, 802.1q VLAN is disabled. 6 IGMP Snoop Enable on Switch MII Interface 1, IGMP snoop enabled. All the IGMP packets will be forwarded to Switch MII port. 0, IGMP snoop disabled. 1, direct mode on port 5. This is a special mode for the 5 Enable Direct Mode on Switch MII Interface Switch MII interface. Using preamble before MRXDV to direct switch to forward packets, bypassing internal look-up. 0, normal operation. 1, packets forwarded to Switch MII interface will be 4 Enable Pre-Tag on pre-tagged with the source port number (preamble Switch MII Interface before MRXDV). 0, normal operation. 00 = always deliver high priority packets first. 3−2 Priority Scheme Select 01 = deliver high/low packets at ratio 10/1. 10 = deliver high/low packets at ratio 5/1. 11 = deliver high/low packets at ratio 2/1. 1 Enable “Tag” Mask 1, the last 5 digits in the VID field are used as a mask to determine which port(s) the packet should be forwarded to. 0, no tag masks. 1, will do Rx AND Tx sniff (both source port and destination port need to match). 0 Sniff Mode Select 0, will do Rx OR Tx sniff (Either source port or destination port needs to match). This is the mode used to implement Rx only sniff. October 2011 50 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Global Registers (Continued) Address Name Description Mode Default R/W 0 R/W Pin SMRXD2 strap option. Pull-down (0): Full-duplex mode. Pull-up (1): Halfduplex mode. Note: SMRXD2 has internal pulldown. R/W Pin SMRXD3 strap option. Pull-down (0): disable flow control. Pull-up(1): enable flow control. Note: SMRXD3 has internal pulldown. R/W Pin SMRXD1 strap option. Pull-down (0): Enable 100Mbps. Pull-up (1): Enable 10Mpbs.Note: SMRXD1 has internal pulldown. R/W 0 R/W 000 Mode Default R/W 0x4A(1) Mode Default R/W 0x24 Mode Default R/W 0x28 Register 6 (0x07): Global Control 4 7 6 5 Switch MII Back Pressure Enable 1, enable MII interface half-duplex mode. Mode 0, enable MII interface full-duplex mode. Switch MII Flow 1, enable full-duplex flow control on switch MII interface. Control Enable 0, disable full-duplex flow control on switch MII interface. Switch MII 10BT 3 Null VID Replacement Address 0, disable back pressure on switch MII interface. Switch MII Half-Duplex 4 2−0 1, enable half-duplex back pressure on switch MII interface. Broadcast Storm Protection Rate Bit [10:8] Name 1, the switch interface is in 10Mbps mode. 0, the switch interface is in 100Mbps mode. 1, will replace null VID with port VID (12 bits). 0, no replacement for null VID. This along with the next register determines how many “64 byte blocks” of packet data allowed on an input port in a preset period. The period is 50ms for 100BT or 500ms for 10BT. The default is 1%. Description Register 7 (0x07): Global Control 5 7−0 Address Broadcast Storm Protection Rate Bit [7:0] Name This along with the previous register determines how many “64 byte blocks” of packet data are allowed on an input port in a preset period. The period is 50ms for 100BT or 500ms for 10BT. The default is 1%. Description Register 8 (0x08): Global Control 6 7−0 Address Factory Testing Reserved Name Description Register 9 (0x09): Global Control 7 7−0 Factory Testing Reserved Note: 148,800 frames/sec × 50ms/interval × 1% = 74 frames/interval (approx.) = 0x4A. October 2011 51 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Global Registers (Continued) Address Name Description Mode Default R/W 0x24 Mode Default Register 10 (0x0A): Global Control 8 7−0 Address Factory Testing Reserved Name Description Register 11 (0x0B): Global Control 9 7−5 Reserved N/A RO 0 4 Reserved N/A RO 0 3 Reserved N/A RO 0 2 Factory Setting Reserved R/W 0 0 = led mode 0. 1 = led mode 1. Mode 0, link at: 100/Full LEDx[2,1,0]=0,0,0 100/Half LEDx[2,1,0]=0,1,0 10/Full LEDx[2,1,0]=0,0,1 10/Half LEDx[2,1,0]=0,1,1 R/W Mode 1, link at: 1 LED Mode 100/Full LEDx[2,1,0]=0,1,0 100/Half LEDx[2,1,0]=0,1,1 10/Full LEDx[2,1,0]=1,0,0 10/Half LEDx[2,1,0]=1,0,1 Pin SMRXD- strap option. Pulldown(0): Enabled led mode 0. Pullup(1): Enabled led mode 1. Note: SMPXD0 has internal pulldown 0. (0=LED on, 1=LED off) 0 Special TIPD Mode October 2011 Mode 0 Mode 1 LEDX_2 Lnk/Act 100Lnk/Act LEDX_1 Fulld/Col 10Lnk/Act LEDX_0 Speed Fulld 1 = enable special tag mode. 0 = disable special tag mode. R/W 52 0 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Port Registers The following registers are used to enable features that are assigned on a per port basis. The register bit assignments are the same for all ports, but the address for each port is different, as indicated. Address Name Description Mode Default Register 16 (0x10): Port 1 Control 0 Register 32 (0x20): Port 2 Control 0 Register 48 (0x30): Port 3 Control 0 Register 64 (0x40): Port 4 Control 0 Register 80 (0x50): Port 5 Control 0 7 Broadcast Storm Protection Enable 1, enable broadcast storm protection for ingress packets on the port. 0, disable broadcast storm protection. R/W 0 6 DiffServ Priority Classification Enable 1, enable DiffServ priority classification for ingress packets on port. 0, disable DiffServ function. R/W 0 5 802.1p Priority Classification Enable 1, enable 802.1p priority classification for ingress packets on port. 0, disable 802.1p. R/W 0 4 Port-Based Priority Classification Enable 1, ingress packets on the port will be classified as high priority if “DiffServ” or “802.1p” classification is not enabled or fails to classify. 0, ingress packets on port will be classified as low priority if “DiffServ” or “802.1p” classification is not enabled or fails to classify. Note: “DiffServ”, “802.1p” and port priority can be enabled at the same time. The OR’ed result of 802.1p and DSCP overwrites the port priority. R/W 0 3 Reserved Reserved R/W 0 Tag insertion 1, when packets are output on the port, the switch will add 802.1q tags to packets without 802.1q tags when received. The switch will not add tags to packets already tagged. The tag inserted is the ingress port’s “port VID.” 0, disable tag insertion. R/W 0 R/W 0 R/W 0 2 1 Tag Removal 1, when packets are output on the port, the switch will remove 802.1q tags from packets with 802.1q tags when received. The switch will not modify packets received without tags. 0, disable tag removal. 1, the port output queue is split into high and low priority queues. 0 Priority Enable October 2011 0, single output queue on the port. There is no priority differentiation even though packets are classified into high or low priority. 53 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Port Registers (Continued) Address Name Description Mode Default Register 17 (0x11): Port 1 Control 1 Register 33 (0x21): Port 2 Control 1 Register 49 (0x31): Port 3 Control 1 Register 65 (0x41): Port 4 Control 1 Register 81 (0x51): Port 5 Control 1 7 Sniffer Port 1, port is designated as sniffer port and will transmit packets that are monitored. 0, port is a normal port. R/W 0 6 Receive Sniff 1, all the packets received on the port will be marked as “monitored packets” and forwarded to the designated “sniffer port.” 0, no receive monitoring. R/W 0 5 Transmit Sniff 1, all the packets transmitted on the port will be marked as “monitored packets” and forwarded to the designated “sniffer port.” 0, no transmit monitoring. R/W 0 Port VLAN Membership Define the port’s Port VLAN membership. Bit 4 stands for port 5, bit 3 for port 4...bit 0 for port 1. The port can only communicate within the membership. A ‘1’ includes a port in the membership, a ‘0’ excludes a port from membership. R/W 0x1f 4−0 Register 18 (0x12): Port 1 Control 2 Register 34 (0x22): Port 2 Control 2 Register 50 (0x32): Port 3 Control 2 Register 66 (0x42): Port 4 Control 2 Register 82 (0x52): Port 5 Control 2 7 Reserved Reserved 0x0 6 Ingress VLAN Filtering. 1, the switch will discard packates whose VID port membership in VLAN table bit[20:16] does not include the ingress port. 0, no ingress VLAN filtering. R/W 0 5 Discard Non-PVID packets 1, the switch will discard packets whose VID does not match ingress port default VID. 0, no packets will be discarded. R/W 0 0 4 Force Flow Control October 2011 1, will always enable Rx and Tx flow control on the port, regardless of AN result. 0, the flow control is enabled based on AN result. 54 R/W For port 4 only, there is a special configuration pin to set the default, Pin PCOL strap option. Pulldown (0): No force flow control. Pullup (1): Force flow control. Note: PCOL has internal pull-down. M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Port Registers (Continued) Address Name Description Mode Default Register 18 (0x12): Port 1 Control 2 Register 34 (0x22): Port 2 Control 2 Register 50 (0x32): Port 3 Control 2 Register 66 (0x42): Port 4 Control 2 Register 82 (0x52): Port 5 Control 2 3 Back Pressure Enable 1, enable port half-duplex back pressure. 0, disable port half-duplex back pressure. R/W Pin PMRXD2 strap option. Pull-down (0): disable back pressure. Pull-up(1): enable back pressure. Note: PMRXD2 has internal pulldown. 2 Transmit Enable 1, enable packet transmission on the port. 0, disable packet transmission on the port. R/W 1 1 Receive Enable 1, enable packet reception on the port. 0, disable packet reception on the port. R/W 1 0 Learning Disable 1, disable switch address learning capability. 0, enable switch address learning. R/W 0 Note: Bits 2-0 are used for spanning tree support. See “Spanning Tree Support” section. Address Name Description Mode Default Port’s default tag, containing: 7-5: user priority bits 4: CFI bit 3-0 : VID[11:8] R/W 0 Default port 1’s tag, containing: 7-0: VID[7:0] R/W 1 Register 19 (0x13): Port 1 Control 3 Register 35 (0x23): Port 2 Control 3 Register 51 (0x33): Port 3 Control 3 Register 67 (0x43): Port 4 Control 3 Register 83 (0x53): Port 5 Control 3 7−0 Default Tag [15:8] Register 20 (0x14): Port 1 Control 4 Register 36 (0x24): Port 2 Control 4 Register 52 (0x34): Port 3 Control 4 Register 68 (0x44): Port 4 Control 4 Register 84 (0x54): Port 5 Control 4 7−0 Default Tag [7:0] Note: Registers 19 and 20 (and those corresponding to other ports) serve two purposes: (1) Associated with the ingress untagged packets, and used for egress tagging; (2) Default VID for the ingress untagged or null-VID-tagged packets, and used for address look up. October 2011 55 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Port Registers (Continued) Address Name Description Mode Default R/W 0 Mode Default R/W 0 Mode Default Register 21 (0x15): Port 1 Control 5 Register 37 (0x25): Port 2 Control 5 Register 53 (0x35): Port 3 Control 5 Register 69 (0x45): Port 4 Control 5 Register 85 (0x55): Port 5 Control 5 7−0 Address Transmit High Priority Rate Control [7:0] This along with port control 7, bits [3:0] form a 12-bit field to determine how many “32Kbps” high priority blocks can be transmitted (in a unit of 4K bytes in a one second period). Name Description Register 22 (0x16): Port 1 Control 6 Register 38 (0x26): Port 2 Control 6 Register 54 (0x36): Port 3 Control 6 Register 70 (0x46): Port 4 Control 6 Register 86 (0x56): Port 5 Control 6 7−0 Address Transmit Low Priority Rate Control [7:0] This along with port control 7, bits [7:4] form a 12-bit field to determine how many “32Kbps” low priority blocks can be transmitted (in a unit of 4K bytes in a one second period). Name Description Register 23 (0x17): Port 1 Control 7 Register 39 (0x27): Port 2 Control 7 Register 55 (0x37): Port 3 Control 7 Register 71 (0x47): Port 4 Control 7 Register 87 (0x57): Port 5 Control 7 7−4 Transmit Low Priority Rate Control [11:8] This along with port control 6, bits [7:0] form a 12-bit field to determine how many “32Kbps” low priority blocks can be transmitted (in a unit of 4K bytes in a one second period). R/W 0 3−0 Transmit High Priority Rate Control [11:8] This along with port control 5, bits [7:0] form a 12-bit field to determine how many “32Kbps” high priority blocks can be transmitted (in unit of 4K bytes in a one second period). R/W 0 Name Description Mode Default R/W 0 Address Register 24 (0x18): Port 1 Control 8 Register 40 (0x28): Port 2 Control 8 Register 56 (0x38): Port 3 Control 8 Register 72 (0x48): Port 4 Control 8 Register 88 (0x58): Port 5 Control 8 7−0 Receive High Priority Rate Control [7:0] October 2011 This along with port control 10, bits [3:0] form a 12-bit field to determine how many “32Kbps” high priority blocks can be received (in a unit of 4K bytes in a one second period). 56 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Port Registers (Continued) Address Name Description Mode Default R/W 0 Mode Default Register 25 (0x19): Port 1 Control 9 Register 41 (0x29): Port 2 Control 9 Register 57 (0x39): Port 3 Control 9 Register 73 (0x49): Port 4 Control 9 Register 89 (0x59): Port 5 Control 9 7−0 Address Receive Low Priority Rate Control [7:0] Name This along with port control 10, bits [7:4] form a 12-bit field to determine how many “32Kbps” low priority blocks can be received (in a unit of 4K bytes in a one second period). Description Register 26 (0x1A): Port 1 Control 10 Register 42 (0x2A): Port 2 Control 10 Register 58 (0x3A): Port 3 Control 10 Register 74 (0x4A): Port 4 Control 10 Register 90 (0x5A): Port 5 Control 10 7−4 Receive Low Priority Rate Control [11:8] This along with port control 9, bits [7:0] form a 12-bit field to determine how many “32Kbps” low priority blocks can be received (in a unit of 4K bytes in a one second period). R/W 0 3−0 Receive High Priority Rate Control [11:8] This along with port control 8, bits [7:0] form a 12-bit field to determine how many “32Kbps” high priority blocks can be received (in a unit of 4K bytes in a one second period). R/W 0 Name Description Mode Default R/W 0 R/W 0 R/W 0 R/W 0 Address Register 27 (0x1B): Port 1 Control 11 Register 43 (0x2B): Port 2 Control 11 Register 59 (0x3B): Port 3 Control 11 Register 75 (0x4B): Port 4 Control 11 Register 91 (0x5B): Port 5 Control 11 7 Receive Differential Priority Rate Control 1, If bit 6 is also ‘1’ this will enable receive rate control for this port on low priority packets at the low priority rate. If bit 5 is also ‘1’, this will enable receive rate control on high priority packets at the high priority rate. 0, receive rate control will be based on the low priority rate for all packets on this port. 6 5 Low Priority Receive Rate Control Enable High Priority Receive Rate Control Enable 1, enable port’s low priority receive rate control feature. 0, disable port’s low priority receive rate control. 1, if bit 7 is also ‘1’ this will enable the port’s high priority receive rate control feature. If bit 7 is a ‘0’ and bit 6 is a ‘1’, all receive packets on this port will be rate controlled at the low priority rate. 0, disable port’s high priority receive rate control feature. 4 Low Priority Receive Rate Flow Control Enable October 2011 1, flow control may be asserted if the port’s low priority receive rate is exceeded. 0, flow control is not asserted if the port’s low priority receive rate is exceeded. 57 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Port Registers (Continued) Address Name Description Mode Default Register 27 (0x1B): Port 1 Control 11 Register 43 (0x2B): Port 2 Control 11 Register 59 (0x3B): Port 3 Control 11 Register 75 (0x4B): Port 4 Control 11 Register 91 (0x5B): Port 5 Control 11 High Priority Receive Rate Flow Control Enable 1, flow control may be asserted if the port’s high priority receive rate is exceeded. To use this, differential receive rate control must be on. 0, flow control is not asserted if the port’s high priority receive rate is exceeded. R/W 0 2 Transmit Differential Priority Rate Control 1, transmit rate control on both high and low priority packets based on the rate counters defined by the high and low priority packets respectively. 0, transmit rate control on any packets. The rate counters defined in low priority will be used. R/W 0 1 Low Priority Transmit Rate Control Enable 1, enable the port’s low priority transmit rate control feature. 0, disable the port’s low priority transmit rate control feature. R/W 0 0 High Priority Transmit Rate Control Enable 1, enable the port’s high priority transmit rate control feature. 0, disable the port’s high priority transmit rate control feature. R/W 0 Mode Default 3 Address Name Description Register 28 (0x1C): Port 1 Control 12 Register 44 (0x2C): Port 2 Control 12 Register 60 (0x3C): Port 3 Control 12 Register 76 (0x4C): Port 4 Control 12 Register 92 (0x5C): Port 5 Control 12 7 Disable Auto-Negotiation 1, disable auto-negotiation, speed and duplex are decided by bit 6 and 5 of the same register. 0, auto-negotiation is on. R/W 0 6 Forced Speed 1, forced 100BT if AN is disabled (bit 7). 0, forced 10BT if AN is disabled (bit 7). R/W 1 5 Forced Duplex 1, forced full-duplex if (1) AN is disabled or (2) AN is enabled but failed. 0, forced half-duplex if (1) AN is disabled or (2) AN is enabled but failed. R/W 0 For port 4 only, there is a special configure pin to set the default pin PCRS strap option. Pulldown (0): Force half-duplex. Pull-up (1): Force fullduplex. Note: PCRS has internal pull down. 4 Advertised Flow Control Capability 1, advertise flow control capability. 0, suppress flow control capability from transmission to link partner. R/W 1 October 2011 58 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Port Registers (Continued) Address Name Description Mode Default Register 28 (0x1C): Port 1 Control 12 Register 44 (0x2C): Port 2 Control 12 Register 60 (0x3C): Port 3 Control 12 Register 76 (0x4C): Port 4 Control 12 Register 92 (0x5C): Port 5 Control 12 3 Advertised 100BT FullDuplex Capability 1, advertise 100BT full-duplex capability. 0, suppress 100BT full-duplex capability from transmission to link partner. R/W 1 2 Advertised 100BT HalfDuplex Capability 1, advertise 100BT half-duplex capability. 0, suppress 100BT half-duplex capability from transmission to link partner. R/W 1 1 Advertised 10BT FullDuplex Capability 1, advertise 10BT full-duplex capability. 0, suppress 10BT full-duplex capability from transmission to link partner. R/W 1 0 Advertised 10BT HalfDuplex Capability 1, advertise 10BT half-duplex capability. 0, suppress 10BT half-duplex capability from transmission to link partner. R/W 1 Note: Port Control 12 and 13, and Port Status 0 contents can be accessed by MIIM (MDC/MDIO) interface via the standard MIIM register definition. Address Name Description Mode Default Register 29 (0x1D): Port 1 Control 13 Register 45 (0x2D): Port 2 Control 13 Register 61 (0x3D): Port 3 Control 13 Register 77 (0x4D): Port 4 Control 13 Register 93 (0x5D): Port 5 Control 13 7 LED Off 1, turn off all port’s LEDs (LEDx_2, LEDx_1, LEDx_0, where “x” is the port number). These pins will be driven high if this bit is set to one. 0, normal operation. R/W 0 6 Txids 1, disable port’s transmitter. 0, normal operation. R/W 0 5 Restart AN 1, restart auto-negotiation. 0 = normal operation. R/W 0 4 Disable far End fault 1, disable far end fault detection and pattern transmission. 0, enable far end fault detection and pattern transmission. R/W 0 3 Power Down 1, power down. 0, normal operation. R/W 0 2 Disable Auto MDI/MDI-X 1, disable auto MDI/MDI-X function. 0, enable auto MDI/MDI-X function. R/W 0 1 Forced MDI 1, if auto MDI/MDI-X is disabled, force PHY into MDI-X mode. 0, MDI mode. R/W 0 0 MAC Loopback 1, perform MAC loopback. 0, normal operation. R/W 0 October 2011 59 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Port Registers (Continued) Address Name Description Mode Default Register 30 (0x1E): Port 1 Status 0 Register 46 (0x2E): Port 2 Status 0 Register 62 (0x3E): Port 3 Status 0 Register 78 (0x4E): Port 4 Status 0 Register 94 (0x5E): Port 5 Status 0 7 MDIX Status 1, MDI-X. 0, MDI. RO 0 6 AN Done 1, AN done. 0, AN not done. RO 0 5 Link Good 1, link good. 0, link not good. RO 0 4 Partner Flow Control Capability 1, link partner flow control capable. 0, link partner not flow control capable. RO 0 3 Partner 100BT Full-Duplex Capability 1, link partner 100BT full-duplex capable. 0, link partner not 100BT full-duplex capable. RO 0 2 Partner 100BT Half-Duplex Capability 1, link partner 100BT half-duplex capable. 0, link partner not 100BT half-duplex capable. RO 0 1 Partner 10BT Full-Duplex Capability 1, link partner 10BT full-duplex capable. RO 0 0 Partner 10BT Half-Duplex Capability 1, link partner 10BT half-duplex capable. RO 0 Address Name 0, link partner not 10BT full-duplex capable. 0, link partner not 10BT half-duplex capable. Description Mode Default Register 31 (0x1F): Port 1 Control 14 Register 47 (0x2F): Port 2 Control 14 Register 63 (0x3F): Port 3 Control 14 Register 79 (0x4F): Port 4 Control 14 Register 95 (0x5F): Port 5 Control 14 7 PHY Loopback 1, perform PHY loopback, i.e. loopback MAC’s Tx back to Rx. 0, normal operation. R/W 0 6 Remote Loopback 1, perform remote loopback, i.e. loopback PHY’s Rx back to Tx. 0, normal operation. R/W 0 5 PHY Isolate 1, electrical isolation of PHY from MII and TX+/TX-. 0, normal operation. R/W 0 R/W 0 1, PHY soft reset. 0, normal operation. 4 Soft Reset 3 Force Link 1, force link in the PHY. 0, normal operation. R/W 0 2−1 Reserved N/A RO 0 far End fault 1, far end fault status detected. 0, no far end fault status detected. RO 0 0 October 2011 Note: this bit is changed to self-cleared for B4 and B5 version parts. 60 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Advanced Control Registers The IPv4 TOS priority control registers implement a fully decoded 64 bit differentiated services code point (DSCP) register used to determine priority from the 6 bit TOS field in the IP header. The most significant 6 bits of the TOS field are fully decoded into 64 possibilities, and the singular code that results is compared against the corresponding bit in the DSCP register. If the register bit is a 1, the priority is high; if it is a 0, the priority is low. Address Name Description Mode Default R/W 00000000 Mode Default R/W 00000000 Mode Default R/W 00000000 Mode Default R/W 00000000 Mode Default R/W 00000000 Mode Default R/W 00000000 Register 96 (0x60): TOS Priority Control Register 0 7−0 Address DSCP[63:56] Name Description Register 97 (0x61): TOS Priority Control Register 1 7−0 Address DSCP[55:48] Name Description Register 98 (0x62): TOS Priority Control Register 2 7−0 Address DSCP[47:40] Name Description Register 99 (0x63): TOS Priority Control Register 3 7−0 Address DSCP[39:32] Name Description Register 100 (0x64): TOS Priority Control Register 4 7−0 Address DSCP[31:24] Name Description Register 101 (0x65): TOS Priority Control Register 5 7−0 DSCP[23:16] October 2011 61 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Advanced Control Registers (Continued) Address Name Description Mode Default R/W 00000000 Mode Default R/W 00000000 Register 102 (0x66): TOS Priority Control Register 6 7−0 Address DSCP[15:8] Name Description Register 103 (0x67): TOS Priority Control Register 7 7−0 DSCP[7:0] Registers 104 to 109 define the switching engine’s MAC address. This 48-bit address is used as the source address in MAC pause control frames. Address Name Description Mode Default R/W 0x00 Mode Default R/W 0x10 Mode Default R/W 0xA1 Mode Default R/W 0xff Mode Default R/W 0xff Register 104 (0x68): MAC Address Register 0 7−0 Address MACA[47:40] Name Description Register 105 (0x69): MAC Address Register 1 7−0 Address MACA[39:32] Name Description Register 106 (0x6A): MAC Address Register 2 7−0 Address MACA[31:24] Name Description Register 107 (0x6B): MAC Address Register 3 7−0 Address MACA[23:16] Name Description Register 108 (0x6C): MAC Address Register 4 7−0 MACA[15:8] October 2011 62 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Advanced Control Registers (Continued) Address Name Description Mode Default R/W 0xff Register 109 (0X6D): MAC Address Register 5 7−0 MACA[7:0] Use registers 110 and 111 to read or write data to the static MAC address table, VLAN table, dynamic address table, or the MIB counters. Address Name Description Mode Default R/W 000 R/W 0 R/W 0 R/W 00 Mode Default R/W 00000000 Register 110 (0x6E): Indirect Access Control 0 7−5 4 Reserved Read High Write Low Reserved. 1, read cycle. 0, write cycle. 00 = static mac address table selected. 3−2 Table Select 01 = VLAN table selected. 10 = dynamic address table selected. 11 = MIB counter selected. 1−0 Address Indirect Address High Bit 9-8 of indirect address. Name Description Register 111 (0x6F): Indirect Access Control 1 7−0 Indirect Address Low Bit 7-0 of indirect address. Note: Write to Register 111 will actually trigger a command. Read or write access will be decided by bit 4 of Register 110. October 2011 63 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Advanced Control Registers (Continued) Address Name Description Mode Default R/W 00000 Mode Default R/W 00000000 Mode Default R/W 00000000 Mode Default R/W 00000000 Mode Default R/W 00000000 Mode Default R/W 00000000 Mode Default R/W 00000000 Mode Default R/W 00000000 Register 112 (0x70): Indirect Data Register 8 68 − 64 Address Indirect Data Bit 68-64 of indirect data. Name Description Register 113 (0x71): Indirect Data Register 7 63 − 56 Address Indirect Data Bit 63-56 of indirect data. Name Description Register 114 (0x72): Indirect Data Register 6 55 − 48 Address Indirect Data Bit 55-48 of indirect data. Name Description Register 115 (0x73): Indirect Data Register 5 47 − 40 Address Indirect Data Bit 47-40 of indirect data. Name Description Register 116 (0x74): Indirect Data Register 4 39 − 32 Address Indirect Data Bit 39-32 of indirect data. Name Description Register 117 (0x75): Indirect Data Register 3 31 − 24 Address Indirect Data Bit of 31-24 of indirect data Name Description Register 118 (0x76): Indirect Data Register 2 23 − 16 Address Indirect Data Bit 23-16 of indirect data. Name Description Register 119 (0x77): Indirect Data Register 1 15 − 8 Indirect Data October 2011 Bit 15-8 of indirect data. 64 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Advanced Control Registers (Continued) Address Name Description Mode Default R/W 00000000 Register 120 (0x78): Indirect Data Register 0 7−0 Indirect Data Bit 7-0 of indirect data. Do not write or read to/from Registers 121 to 127. Doing so may prevent proper operation. Micrel internal testing only. Address Name Description Mode Default RO 0x0 Mode Default RO 0x0 Mode Default R/W 0x0 Mode Default R/W 0x0 Mode Default R/W 0x0 Mode Default Reserved. R/W 0x0 Reserved. RO 0x0 Register 121 (0x79): Digital Testing Status 0 7−0 Address Factory Testing Reserved. Qm_split status Name Description Register 122 (0x7A): Digital Testing Status 1 7−0 Address Factory Testing Reserved. Debug[7:0] Name Description Register 123 (0x7B): Digital Testing Control 0 7−0 Address Factory Testing Reserved. Debug[12:8] Name Description Register 124 (0x7C): Digital Testing Control 1 7−0 Address Factory Testing Reserved. Name Description Register 125 (0x7D): Analog Testing Control 0 7−0 Address Factory Testing Reserved. Name Description Register 126 (0x7E): Analog Testing Control 1 7−0 Factory Testing Register 127 (0x7F): Analog Testing Status 7−0 Factory Testing October 2011 65 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Static MAC Address KS8995MA/FQ has a static and a dynamic address table. When a DA look-up is requested, both tables will be searched to make a packet forwarding decision. When an SA look-up is requested, only the dynamic table is searched for aging, migration, and learning purposes. The static DA look-up result will have precedence over the dynamic DA look-up result. If there are DA matches in both tables, the result from the static table will be used. The static table can only be accessed and controlled by an external SPI master (usually a processor). The entries in the static table will not be aged out by KS8995MA/FQ. An external device does all addition, modification and deletion. Note: Register bit assignments are different for static MAC table reads and static MAC table write, as shown below: Address Name Description Mode Default Format of Static MAC Table for Reads (8 entries) 60 − 57 FID Filter VLAN ID, representing one of the 16 active VLANs RO 0000 56 Use FID 1, use (FID+MAC) to look-up in static table. 0, use MAC only to look-up in static table. RO 0 55 Reserved Reserved. RO N/A 54 Override 1, override spanning tree “transmit enable = 0” or “receive enable = 0* setting. This bit is used for spanning tree implementation. 0, no override. RO 0 53 Valid 1, this entry is valid, the look-up result will be used. 0, this entry is not valid. RO 0 52 − 48 Forwarding Ports The 5 bits control the forward ports, example: 00001, forward to port 1 00010, forward to port 2 ….. 10000, forward to port 5 00110, forward to port 2 and port 3 11111, broadcasting (excluding the ingress port) RO 00000 47 − 0 MAC Address 48 bit MAC address. RO 0x0 W 0000 W 0 W 0 W 0 W 00000 Format of Static MAC Table for Writes (8 entries) 59 − 56 55 54 FID Use FID Override Filter VLAN ID, representing one of the 16 active VLANs. 1, use (FID+MAC) to look-up in static table. 0, use MAC only to look-up in static table. 1, override spanning tree “transmit enable = 0” or “receive enable = 0” setting. This bit is used for spanning tree implementation. 0, no override. 53 Valid 1, this entry is valid, the look-up result will be used. 0, this entry is not valid. The 5 bits control the forward ports, example: 00001, forward to port 1 00010, forward to port 2 52 − 48 Forwarding Ports ..... 10000, forward to port 5 00110, forward to port 2 and port 3 11111, broadcasting (excluding the ingress port) 47 − 0 MAC Address October 2011 48-bit MAC address. W 66 0x0 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Static Address Table Examples (1) Static Address Table Read (read the 2nd entry) Write to Register 110 with 0x10 (read static table selected) Write to Register 111 with 0x1 (trigger the read operation) Then, Read Register 113 (60 − 56) Read Register 114 (55 − 48) Read Register 115 (47 − 40) Read Register 116 (39 − 32) Read Register 117 (31 − 24) Read Register 118 (23 − 16) Read Register 119 (15 − 8) Read Register 120 (7 − 0) Static Address Table Write Examples (2) Static Address Table Write (write the 8th entry) Write to Register 110 with 0x10 (read static table selected) Write Register 113 (59 − 56) Write Register 114 (55 − 48) Write Register 115 (47 − 40) Write Register 116 (39 − 32) Write Register 117 (31 − 24) Write Register 118 (23 − 16) Write Register 119 (15 − 8) Write Register 120 (7 − 0) Write to Register 110 with 0x00 (write static table selected) Write to Register 111 with 0x7 (trigger the write operation) October 2011 67 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ VLAN Address The VLAN table is used for VLAN table look-up. If 802.1q VLAN mode is enabled (Register 5 Bit 7 = 1), this table is used to retrieve VLAN information that is associated with the ingress packet. The information includes FID (filter ID), VID (VLAN ID), and VLAN membership described below: Address Name Description Mode Default R/W 1 R/W 11111 R/W 0 R/W 1 Format of Static VLAN Table (16 entries) 21 Valid 1, the entry is valid. 0, entry is invalid. Specify which ports are members of the VLAN. 20 − 16 Membership If a DA look-up fails (no match in both static and dynamic tables), the packet associated with this VLAN will be forwarded to ports specified in this field. E.g., 11001 means port 5, 4, and 1 are in this VLAN. 15 − 12 FID 11 − 0 VID Filter ID. KS8995MA/FQ supports 16 active VLANs represented by these four bit fields. FID is the mapped ID. If 802.1q VLAN is enabled, the look-up will be based on FID+DA and FID+SA. IEEE 802.1q 12 bit VLAN ID. If 802.1q VLAN mode is enabled, KS8995MA/FQ assigns a VID to every ingress packet. If the packet is untagged or tagged with a null VID, the packet is assigned with the default port VID of the ingress port. If the packet is tagged with non-null VID, the VID in the tag is used. The look-up process starts from the VLAN table look-up. If the VID is not valid, the packet is dropped and no address learning occurs. If the VID is valid, the FID is retrieved. The FID+DA and FID+SA lookups are performed. The FID+DA look-up determines the forwarding ports. If FID+DA fails, the packet is broadcast to all the members (excluding the ingress port) of the VLAN. If FID+SA fails, the FID+SA is learned. VLAN Table Read Example (1) VLAN Table Read (read the 3rd entry) Write to Register 110 with 0x14 (read VLAN table selected) Write to Register 111 with 0x2 (trigger the read operation) Then, Read Register 118 (VLAN table bits 21-16) Read Register 119 (VLAN table bits 15-8) Read Register 120 (VLAN table bits 7-0) VLAN Table Write Example (2) VLAN Table Write (write the 7th entry) Write to Register 118 (VLAN table bits 21-16) Write to Register 119 (VLAN table bits 15-8) Write to Register 120 (VLAN table bits 7-0) Write to Register 110 with 0x04 (write VLAN table selected) Write to Register 111 with 0x6 (trigger the write operation) Note: The sequence of the writing entries should start from entry 0. Improper sequence of the VLAN entries could cause the VLAN to be non-functional. October 2011 68 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Dynamic MAC Address The table below is read only; the contents are managed by the KS8995MA/FQ only. Address Name Description Mode Default RO 1 RO 0 Format of Dynamic MAC Address Table (1K entries) 68 MAC Empty 1, there is no valid entry in the table. 0, there are valid entries in the table. Indicates how many valid entries in the table. 0x3ff means 1K entries 67 − 58 No of Valid Entries 0x1 means 2 entries 0x0 and bit 68 = 0: means 1 entry 0x0 and bit 68 = 1: means 0 entry 57 − 56 55 Time Stamp Data Ready 2-bit counters for internal aging RO 1, The entry is not ready, retry until this bit is set to 0. 0, The entry is ready. RO The source port where FID+MAC is learned. 000 port 1 54 − 52 Source Port 001 port 2 010 port 3 RO 0x0 011 port 4 100 port 5 51 − 48 FID Filter ID. RO 0x0 47 − 0 MAC Address 48-bit MAC address. RO 0x0 Dynamic MAC Address Table Read Example (1) Dynamic MAC Address Table Read (read the 1st entry), and retrieve the MAC table size Write to Register 110 with 0x18 (read dynamic table selected) Write to Register 111 with 0x0 (trigger the read operation) Then, Read Register 112 (68-64) Read Register 113 (63-56); // the above two registers show # of entries Read Register 114 (55-48) // if bit 55 is 1, restart (reread) from this register Read Register 115 (47-40) Read Register 116 (39-32) Read Register 117 (31-24) Read Register 118 (23-16) Read Register 119 (15-8) Read Register 120 (7-0) October 2011 69 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Dynamic MAC Address Table Write Example (2) Dynamic MAC Address Table Read (read the 257th entry), without retrieving # of entries information Write to Register 110 with 0x19 (read dynamic table selected) Write to Register 111 with 0x1 (trigger the read operation) Then, Read Register 114 (55-48) // if bit 55 is 1, restart (reread) from this register Read Register 115 (47-40) Read Register 116 (39-32) Read Register 117 (31-24) Read Register 118 (23-16) Read Register 119 (15-8) Read Register 120 (7-0) October 2011 70 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ MIB Counters The MIB counters are provided on per-port basis. The indirect memory is as detailed in the following table(s). Offset Counter Name Description 0x0 RxLoPriorityByte Rx lo-priority (default) octet count including bad packets. 0x1 RxHiPriorityByte Rx hi-priority octet count including bad packets. 0x2 RxUndersizePkt Rx undersize packets w/good CRC. 0x3 RxFragments Rx fragment packets w/bad CRC, symbol errors or alignment errors. 0x4 RxOversize Rx oversize packets w/good CRC (max: 1536 or 1522 bytes). 0x5 RxJabbers Rx oversize packets w/either CRC errors, alignment errors, or symbol errors (depends on max packet size setting) or Rx packets longer than 1916B only. 0x6 RxSymbolError Rx packets w/ invalid data symbol and legal preamble, packet size. 0x7 RxCRCerror Rx packets within (64,1522) bytes w/an integral number of bytes and a bad CRC (upper limit depends on max packet size setting). 0x8 RxAlignmentError Rx packets within (64,1522) bytes w/a non-integral number of bytes and a bad CRC (upper limit depends on max packet size setting). 0x9 RxControl8808Pkts The number of MAC control frames received by a port with 88-08h in EtherType field. 0xA RxPausePkts The number of PAUSE frames received by a port. PAUSE frame is qualified with EtherType (88-08h), DA, control opcode (00-01), data length (64B min), and a valid CRC. 0xB RxBroadcast Rx good broadcast packets (not including errored broadcast packets or valid multicast packets). 0xC RxMulticast Rx good multicast packets (not including MAC control frames, errored multicast packets or valid broadcast packets). 0xD RxUnicast Rx good unicast packets. 0xE Rx64Octets Total Rx packets (bad packets included) that were 64 octets in length. 0xF Rx65to127Octets Total Rx packets (bad packets included) that are between 65 and 127 octets in length. 0x10 Rx128to255Octets Total Rx packets (bad packets included) that are between 128 and 255 octets in length. 0x11 Rx256to511Octets Total Rx packets (bad packets included) that are between 256 and 511 octets in length. 0x12 Rx512to1023Octets Total Rx packets (bad packets included) that are between 512 and 1023 octets in length. 0x13 Rx1024to1522Octets Total Rx packets (bad packets included) that are between 1024 and 1522 octets in length (upper limit depends on max packet size setting). 0x14 TxLoPriorityByte Tx lo-priority good octet count, including PAUSE packets. 0x15 TxHiPriorityByte Tx hi-priority good octet count, including PAUSE packets. 0x16 TxLateCollision The number of times a collision is detected later than 512 bit-times into the Tx of a packet. 0x17 TxPausePkts The number of PAUSE frames transmitted by a port. 0x18 TxBroadcastPkts Tx good broadcast packets (not including errored broadcast or valid multicast packets). 0x19 TxMulticastPkts Tx good multicast packets (not including errored multicast packets or valid broadcast packets). 0x1A TxUnicastPkts Tx good unicast packets. 0x1B TxDeferred Tx packets by a port for which the 1st Tx attempt is delayed due to the busy medium. 0x1C TxTotalCollision Tx total collision, half-duplex only. 0x1D TxExcessiveCollision A count of frames for which Tx fails due to excessive collisions. 0x1E TxSingleCollision Successfully Tx frames on a port for which Tx is inhibited by exactly one collision. 0x1F TxMultipleCollision Successfully Tx frames on a port for which Tx is inhibited by more than one collision. October 2011 71 M9999-102611-3.0 Micrel, Inc. Address KS8995MA/FQ Name Description Mode Default RO 0 RO 0 RO 0 Mode Default For port 2, the base is 0x20, same offset definition (0x20-0x3f) For port 3, the base is 0x40, same offset definition (0x40-0x5f) For port 4, the base is 0x60, same offset definition (0x60-0x7f) For port 5, the base is 0x80, same offset definition (0x80-0x9f) Format of Per Port MIB Counters (16 entries) 31 Overflow 30 Count Valid 1, Counter overflow. 0, No Counter overflow. 1, Counter value is valid. 0, Counter value is not valid. 29 − 0 Counter Values Counter value. Offset Counter Name Description 0x100 Port1 Tx Drop Packets Tx packets dropped due to lack of resources. 0x101 Port2 Tx Drop Packets Tx packets dropped due to lack of resources. 0x102 Port3 Tx Drop Packets Tx packets dropped due to lack of resources. 0x103 Port4 Tx Drop Packets Tx packets dropped due to lack of resources. 0x104 Port5 Tx Drop Packets Tx packets dropped due to lack of resources. 0x105 Port1 Rx Drop Packets Rx packets dropped due to lack of resources. 0x106 Port2 Rx Drop Packets Rx packets dropped due to lack of resources. 0x107 Port3 Rx Drop Packets Rx packets dropped due to lack of resources. 0x108 Port4 Rx Drop Packets Rx packets dropped due to lack of resources. 0x109 Port5 Rx Drop Packets Rx packets dropped due to lack of resources. Name Description Address Format of All Port Dropped Packet MIB Counters 30-16 Reserved Reserved. N/A N/A 15-0 Counter Values Counter value. RO 0 Note: All port dropped packet MIB counters do not indicate overflow or validity; therefore the application must keep track of overflow and valid conditions. October 2011 72 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ MIB Counter Read Examples (1) MIB counter read (read port 1 rx 64 counter) Write to Register 110 with 0x1c (read MIB counters selected) Write to Register 111 with 0xe (trigger the read operation) Then, Read Register 117 (counter value 31-24) // If bit 31 = 1, there was a counter overflow // If bit 30 = 0, restart (reread) from this register Read Register 118 (counter value 23-16) Read Register 119 (counter value 15-8) Read Register 120 (counter value 7-0) (2) MIB counter read (read port 2 rx 64 counter) Write to Register 110 with 0x1c (read MIB counter selected) Write to Register 111 with 0x2e (trigger the read operation) Then, Read Register 117 (counter value 31-24) //If bit 31 = 1, there was a counter overflow //If bit 30 = 0, restart (reread) from this register Read Register 118 (counter value 23-16) Read Register 119 (counter value 15-8) Read Register 120 (counter value 7-0) (3) MIB counter read (read port 1 tx drop packets) Write to Register 110 with 0x1d Write to Register 111 with 0x00 Then, Read Register 119 (counter value 15-8) Read Register 120 (counter value 7-0) Note: To read out all the counters, the best performance over the SPI bus is (160+3) × 8 × 200 = 260ms, where there are 160 registers, 3 overhead, 8 clocks per access, at 5MHz. In the heaviest condition, the byte counter will overflow in 2 minutes. It is recommended that the software read all the counters at least every 30 seconds. The per port MIB counters are designed as “read clear.” A per port MIB counter will be cleared after it is accessed. All port dropped packet MIB counters are not cleared after they are accessed. The application needs to keep track of overflow and valid conditions on these counters. October 2011 73 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ MIIM Registers All the registers defined in this section can be also accessed via the SPI interface. Note: different mapping mechanisms used for MIIM and SPI. The “PHYAD” defined in IEEE is assigned as “0x1” for port 1, “0x2” for port 2, “0x3” for port 3, “0x4” for port 4, and “0x5” for port 5. The “REGAD” supported are 0, 1, 2, 3, 4, 5. Address Name Description Mode Default R/W 0 W 0 R/W 1 R/W 1 R/W 0 R/W 0 R/W 0 R/W 0 RO 0 Register 0: MII Control 1, PHY soft reset. 15 Soft Reset 14 Loop Back 13 Force 100 12 AN Enable 11 Power Down 10 PHY Isolate 9 Restart AN 8 Force Full Duplex 7 Collision Test 6 Reserved RO 0 5 Reserved RO 0 4 Force MDI R/W 0 3 Disable Auto MDI/MDI-X R/W 0 2 Disable far End fault R/W 0 1 Disable Transmit R/W 0 0 Disable LED R/W 0 October 2011 0, Normal operation. 1, Loop back mode (loopback at MAC). 0, Normal operation. 1, 100Mbps. 0, 10Mbps. 1, Auto-negotiation enabled. 0, Auto-negotiation disabled. 1, Power down. 0, Normal operation. 1, Electrical PHY isolation of PHY from Tx+/Tx-. 0, Normal operation. 1, Restart Auto-negotiation. 0, Normal operation. 1, Full duplex. 0, Half duplex. Not supported. 1, Force MDI. 0, Normal operation. 1, Disable auto MDI/MDI-X. 0, Normal operation. 1, Disable far end fault detection. 0, Normal operation. 1, Disable transmit. 0, Normal operation. 1, Disable LED. 0, Normal operation. 74 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ MIIM Registers (Continued) Address Name Description Mode Default RO 0 RO 1 RO 1 RO 1 RO 1 RO 0 RO 0 RO 0 RO 0 RO 1 RO 0 Register 1: MII Status 15 T4 Capable 14 100 Full Capable 13 100 Half Capable 12 10 Full Capable 11 10 Half Capable 10 − 7 0, Not 100 BASET4 capable. 1, 100BASE-TX full-duplex capable. 0, Not capable of 100BASE-TX full-duplex. 1, 100BASE-TX half-duplex capable. 0, Not 100BASE-TX half-duplex capable. 1, 10BASE-T full-duplex capable. 0, Not 10BASE-T full-duplex capable. 1, 10BASE-T half-duplex capable. 0, 10BASE-T half-duplex capable. Reserved 6 Preamble Suppressed Not supported. 5 AN Complete 4 far End fault 3 AN Capable 2 Link Status 1 Jabber Test Not supported. RO 0 0 Extended Capable 0, Not extended register capable. RO 0 High order PHYID bits. RO 0x0022 Low order PHYID bits. RO 0x1450 1, Auto-negotiation complete. 0, Auto-negotiation not completed. 1, far end fault detected. 0, No far end fault detected. 1, Auto-negotiation capable. 0, Not auto-negotiation capable. 1, Link is up. 0, Link is down. Register 2: PHYID HIGH 15 − 0 Phyid High Register 3: PHYID LOW 15 − 0 Phyid Low October 2011 75 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ MIIM Registers (Continued) Address Name Description Mode Default RO 0 RO 0 RO 0 RO 0 R/W 1 R/W 0 R/W 1 R/W 1 R/W 1 R/W 1 802.3 RO 00001 Register 4: Advertisement Ability 15 Next Page 14 Reserved 13 Remote fault 12 − 11 Not supported. Reserved 10 Pause 9 Reserved 8 Adv 100 Full 7 Adv 100 Half 6 Adv 10 Full 5 Adv 10 Half 4−0 Not supported. Selector Field 1, Advertise pause ability. 0, Do not advertise pause ability. 1, Advertise 100 full-duplex ability. 0, Do not advertise 100 full-duplex ability. 1, Advertise 100 half-duplex ability. 0, Do not advertise 100 half-duplex ability. 1, Advertise 10 full-duplex ability. 0, Do not advertise 10 full-duplex ability. 1, Advertise 10 half-duplex ability. 0, Do not advertise 10 half-duplex ability. Register 5: Link Partner Ability 15 Next Page Not supported. RO 0 14 LP ACK Not supported. RO 0 13 Remote fault Not supported. RO 0 RO 0 RO 0 RO 0 12 − 11 Reserved 10 Pause 9 Reserved 8 Adv 100 Full Link partner 100 full capability. RO 0 7 Adv 100 Half Link partner 100 half capability. RO 0 6 Adv 10 Full Link partner 10 full capability. RO 0 5 Adv 10 Half Link partner 10 half capability. RO 0 RO 00001 4−0 Link partner pause capability. Reserved October 2011 76 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Absolute Maximum Ratings(1) Operating Ratings(2) Supply Voltage (VDDR, VDDAP, VDDC). ............................... −0.5V to +2.4V (VDDAT, VDDIO) ......................................... −0.5V to +4.0V Input Voltage ................................................ −0.5V to +4.0V Output Voltage ............................................. −0.5V to +4.0V Lead Temperature (soldering, 10s) ............................ 260°C Storage Temperature (Ts) ......................... −55°C to +150°C Supply Voltage (VDDAR, VDDAP, VDDC) ............................... +1.7V to +1.9V (VDDAT)................................................ +3.15V to +3.45V (VDDIO) ................................................ +3.15V to +3.45V Ambient Temperature (TA) ................................................... Commercial............................................... 0°C to +85°C Industrial ............................................... –40°C to +85°C Package Thermal Resistance(3) PQFP (θJA) − No Air Flow ............................. 42.91°C/W PQFP (θJA) − No Air Flow ............................... 19.6°C/W Electrical Characteristics(4, 5) Symbol Parameter Condition Min. Typ. Max. Units VDDAT 20 28 mA 100BASE-TX Operation—All Ports 100% Utilization IDX 100BASE-TX (Transmitter) IDDC 100BASE-TX (Digital Core/PLL+ Analog Rx) VDDC, VDDAP, VDDAR 157 230 mA IDDIO 100BASE-TX (Digital IO) VDDIO 17 30 mA 10BASE-T (Transmitter) VDDAT 15 25 mA IDDC 10BASE-T (Digital Core + Analog Rx) VDDC, VDDAP 102 180 mA IDDIO 10BASE-T (Digital IO) VDDIO 6 15 mA 10BASE-T Operation —All Ports 100% Utilization IDX Auto-Negotiation Mode IDX 10BASE-T (Transmitter) VDDAT 25 40 mA IDDC 10BASE-T (Digital Core + Analog Rx) VDDC, VDDAP 108 180 mA IDDIO 10BASE-T (Digital IO) VDDIO 17 20 mA TTL Inputs VIH Input High Voltage VIL Input Low Voltage IIN Input Current (Excluding Pull-up/Pull-down) +2.0 VIN = GND ~ VDDIO –10 +2.4 V +0.8 V 10 µA TTL Outputs VOH Output High Voltage IOH = –8mA VOL Output Low Voltage IOL = 8mA IOZ Output Tri-State Leakage VIN = GND ~ VDDIO V +0.4 V 10 µA Notes: 1. Exceeding the absolute maximum rating may damage the device. 2. The device is not guaranteed to function outside its operating rating. Unused inputs must always be tied to an appropriate logic voltage level (Ground to VDD). 3. No heat spreader in package. The thermal junction-to-ambient (θJA) and the thermal junction-to-case (θJC) are under air velocity 0m/s. 4. Specification for packaged product only. A single port’s transformer consumes an additional 40mA (approximately) for 100Base-TX and 59mA for 10Base-T. 5. Measurements were taken with operating ratings. October 2011 77 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Electrical Characteristics(4, 5) (Continued) Symbol Parameter Condition Min. Typ. Max. Units 100BASE-TX Transmit (measured differentially after 1:1 transformer) VO Peak Differential Output Voltage 100Ω termination on the differential output VIMB Output Voltage Imbalance 100Ω termination on the differential output tr tt 0.95 Rise/fall Time 3 Rise/fall Time Imbalance 0 1.00 Duty Cycle Distortion Overshoot VSET Reference Voltage of ISET Output Jitters 1.05 V 2 % 5 ns 0.5 ns ±0.5 ns 5 % 0.5 Peak-to-peak 0.7 V 1.4 ns 10BASE-T Receive VSQ Squelch Threshold 5MHz square wave 10BASE-T Transmit (measured differentially after 1:1 transformer) VDDAT = 3.3V VP Peak Differential Output Voltage Jitters Added 100Ω termination on the differential output 100Ω termination on the differential output Rise/fall Times October 2011 400 mV 2.5 V 28 78 16 ns 30 ns M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Timing Diagrams Figure 13. EEPROM Interface Input Receive Timing Diagram Figure 14. EEPROM Interface Output Transmit Timing Diagram Symbol Parameter Min. Typ. Max. tCYC1 Clock Cycle tS1 Set-Up Time 20 ns tH1 Hold Time 20 ns tOV1 Output Valid 16384 4096 4112 Units ns 4128 ns Table 10. EEPROM Timing Parameters October 2011 79 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Timing Diagrams (Continued) Figure 15. SNI Input Timing Figure 16. SNI Output Timing Symbol Parameter Min. Typ. Max. tCYC2 Clock Cycle tS2 Set-Up Time 10 ns tH2 Hold Time 0 ns tO2 Output Valid 0 100 3 Units ns 6 ns Table 11. SNI Timing Parameters October 2011 80 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Timing Diagrams (Continued) Figure 17. MAC Mode MII Timing − Data Received from MII Figure 18. MAC Mode MII Timing − Data Transmitted from MII 10Base-T/100Base-TX Symbol Parameter tCYC3 Clock Cycle tS3 Set-Up Time 10 ns tH3 Hold Time 5 ns tOV3 Output Valid 3 Min. Typ. Max. 400/40 9 Units ns 25 ns Table 12. MAC Mode MII Timing Parameters October 2011 81 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Timing Diagrams (Continued) Figure 19. PHY Mode MII Timing − Data Received from MII Figure 20. PHY Mode MII Timing − Data Transmitted from MII 10BaseT/100BaseT Symbol Parameter tCYC4 Clock Cycle tS4 Set-Up Time 10 ns tH4 Hold Time 0 ns tOV4 Output Valid 10 Min. Typ. Max. 400/40 20 Units ns 25 ns Table 13. PHY Mode MII Timing Parameters October 2011 82 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Timing Diagrams (Continued) Figure 21. SPI Input Timing Symbol Parameter Min. Typ. Max. Units fC Clock Frequency 5 MHz tCHSL SPIS_N Inactive Hold Time 90 ns tSLCH SPIS_N Active Set-Up Time 90 ns tCHSH SPIS_N Active Hold Time 90 ns tSHCH SPIS_N Inactive Set-Up Time 90 ns tSHSL SPIS_N Deselect Time 100 ns tDVCH Data Input Set-Up Time 20 ns tCHDX Data Input Hold Time 30 ns tCLCH Clock Rise Time 1 µs tCHCL Clock Fall Time 1 µs tDLDH Data Input Rise Time 1 µs tDHDL Data Input fall Time 1 µs Table 14. SPI Input Timing Parameters October 2011 83 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Timing Diagrams (Continued) Figure 22. SPI Output Timing Symbol Parameter Min. fC Clock Frequency tCLQX SPIQ Hold Time tCLQV Clock Low to SPIQ Valid tCH Clock High Time 90 ns tCL Clock Low Time 90 ns tQLQH SPIQ Rise Time 50 ns tQHQL SPIQ Fall Time 50 ns tSHQZ SPIQ Disable Time 100 ns 0 Typ. Max. Units 5 MHz 0 ns 60 ns Table 15. SPI Output Timing Parameters October 2011 84 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Timing Diagrams (Continued) Figure 23. Reset Timing Symbol Parameter Min. Typ. Max. Units tSR Stable Supply Voltages to Reset High 10 ms tCS Configuration Set-Up Time 50 ns tCH Configuration Hold Time 50 ns tRC Reset to Strap-In Pin Output 50 ns Table 16. Reset Timing Parameters October 2011 85 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Reset Circuit Diagram Micrel recommends the following discrete reset circuit as shown in Figure 24 when powering up the KS8895MA device. For the application where the reset circuit signal comes from another device (e.g., CPU, FPGA, etc), we recommend the reset circuit as shown in Figure 25. Figure 24. Recommended Reset Circuit Figure 25. Recommended Circuit for Interfacing with CPU/FPGA Reset At power-on-reset, R, C, and D1 provide the necessary ramp rise time to reset the Micrel device. The reset out from CPU/FPGA provides warm reset after power up. October 2011 86 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Selection of Isolation Transformer(1) One simple 1:1 isolation transformer is needed at the line interface. An isolation transformer with integrated commonmode choke is recommended for exceeding FCC requirements. The following table gives recommended transformer characteristics. Characteristics Name Value Turns Ratio Test Condition 1 CT : 1 CT Open-Circuit Inductance (min.) 350µH 100mV, 100kHz, 8mA Leakage Inductance (max.) 0.4µH 1MHz (min.) Inter-Winding Capacitance (max.) 12pF D.C. Resistance (max.) 0.9Ω Insertion Loss (max.) 1.0dB HIPOT (min.) 0MHz to 65MHz 1500Vrms Note: 1. The IEEE 802.3u standard for 100BASE-TX assumes a transformer loss of 0.5dB. For the transmit line transformer, insertion loss of up to 1.3dB can be compensated by increasing the line drive current by means of reducing the ISET resistor value. The following transformer vendors provide compatible magnetic parts for Micrel’s device. 4-Port Integrated Single Port Auto MDIX Auto MDIX Number of Ports H1102 Yes 1 Bel Fuse S558-5999-U7 Yes 1 4 YCL PT163020 Yes 1 Yes 4 Transpower HB726 Yes 1 LF8731 Yes 4 Delta LF8505 Yes 1 SQ-H48W Yes 4 LanKom LF-H41S Yes 1 Vendor Part Pulse H1164 Yes Bel Fuse 558-5999-Q9 YCL Number of Ports Vendor Part 4 Pulse Yes 4 PH406466 Yes Transpower HB826-2 Delta LanKom Table 17. Qualified Magnetic Vendors October 2011 87 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ Package Information 128-Pin PQFP (PQ) October 2011 88 M9999-102611-3.0 Micrel, Inc. KS8995MA/FQ MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA TEL +1 (408) 944-0800 FAX +1 (408) 474-1000 WEB http://www.micrel.com Micrel makes no representations or warranties with respect to the accuracy or completeness of the information furnished in this data sheet. This information is not intended as a warranty and Micrel does not assume responsibility for its use. Micrel reserves the right to change circuitry, specifications and descriptions at any time without notice. No license, whether express, implied, arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Micrel’s terms and conditions of sale for such products, Micrel assumes no liability whatsoever, and Micrel disclaims any express or implied warranty relating to the sale and/or use of Micrel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s use or sale of Micrel Products for use in life support appliances, devices or systems is a Purchaser’s own risk and Purchaser agrees to fully indemnify Micrel for any damages resulting from such use or sale. © 2010 Micrel, Incorporated. October 2011 89 M9999-102611-3.0