SENSORTECHNICS KTEM8400G4CXSEV

KTE8000/KTU8000...CS Series
Submersible pressure transducers
FEATURES
· 0...250 mbar to 0...2000 mbar,
0...5 to 0...30 psi gage
· For corrosive media
· 4...20 mA output
· Field interchangeable
MEDIA COMPATIBILITY
Wetted materials:
PPS, ceramic Al2O3, NBR (Viton), PUR (PE)11
Housing:
protection class IP 68 (according to DIN EN 60529)
respectively NEMA 6P1
ELECTRICAL CONNECTION
SPECIFICATIONS9,10
Maximum ratings
Supply voltage2
(reverse polarity protection)
Temperature limits
Storage
Operating
Compensated
Vibration (5 to 500 Hz)
Mechanical shock
Proof pressure3
August 2008 / 225
9...32 V
+Vs
9 to 32 V
-40 to 70°C
-25 to 70°C
0 to 70°C
10 gRMS
50 g
2 x rated pressure
red
sensor
V
-Vs
black
RL
GND
1/4
www.sensortechnics.com
KTE8000/KTU8000...CS Series
Submersible pressure transducers
INDIVIDUAL PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Typ.
Max.
Zero pressure offset
0
0
0
0
0
0
0
0
0
0
0
3.9
4.0
250
400
600
1000
1600
2000
5
10
15
20
30
4.1
Full scale span7
15.9
16.0
16.1
0.25 bar / 5 psi / 2.5 mH2O
±0.04
±0.08
< 1 bar / 15 psi / 10 mH2O
±0.03
±0.06
all others
±0.02
±0.04
±0.02
±0.04
Operating pressure
Thermal effects4 (0 to 70°C)
Min.
KTEM8250...
KTEM8400...
KTEM8600...
KTEM81K0...
KTEM81K6...
KTEM82K0...
KTU8005...
KTU8010...
KTU8015...
KTU8020...
KTU8030...
Offset
Span
Thermal effects (-25 to 0°C)
Offset
< 1 bar / 15 psi / 10 mH2O
±0.06
all others
±0.03
Span
Non-linearity, hysteresis (BSL) and repeatability
±0.1
Output noise (0 < f < 1 kHz)
±0.2
Long term stability6
±0.2
Power supply rejection
mbar
p si
mA
%FSO/°C
±0.03
5
Response time (10 to 90 %)
Unit
1
Offset
±0.05
Span
±0.05
±0.3
%FSO
5
ms
%FSO/V
Specification notes:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
The package is an all-sealed housing. For proper function the gage port is vented to the atmosphere through the
connecting cable. Thus the vent tube of the cable end must have access to the ambient pressure.
The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagram.
Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
Thermal effects tested and guaranteed from 0...70°C relative to 25°C. All specifications shown are relative to 25°C.
Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span.
Long term stability is the change in output after one year or 1 million pressure cycles.
Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure.
Tests are in accordance with EN61000-6-2, April 1999.
CE-labelling is in accordance with 89/336/EEC.
The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
Other sealing materials are available on request.
August 2008 / 225
2/4
www.sensortechnics.com
KTE8000/KTU8000...CS Series
Submersible pressure transducers
ELECTROMAGNETIC CAPABILITY8
Test conditions
Criterion
Interference
Grade 3
10 V/m, 80 MHz to 1000 MHz
80 % AMC (1 kHz)
A
<1 % FSO
Radiated, radio frequency
electromagnetic field
immunity (RFI)
EN61000-4-3:
Electrical fast transient /
burst immunity (EFT)
EN61000-4-4:
Grade 3
±2 kV
B
<1 % FSO
Electrostatic discharge
immunity test (ESD)
EN61000-4-2:
Grade 4
±4 kV, contact discharge
± 8kV, air discharge
B
<1 % FSO
Immunity to conducted
disturbances induced by
radio-frequency fields
EN61000-4-6:
Grade 3
0,15 to 80 MHz
10 V, 80 % AMC (1 kHz)
A
<1 % FSO
Surge immunity
EN61000-4-5:
Grade 1
±0.5 kV, symmetric/asymmetric
Grade 2
±1 kV, asymmetric
B
<1 % FSO
LOAD LIMITATION
1400
Ohm
1200
1000
800
op
e
ra ratin
ng g
e
600
400
200
0
August 2008 / 225
5
9
16 20 25 30 32 V
supply voltage
3/4
www.sensortechnics.com
KTE8000/KTU8000...CS Series
Submersible pressure transducers
OUTLINE DRAWING
NOM 122.5
(4.82)
NOM 70
(2.76)
other cable lengths
on request
NOM 100
(3.94)
Ø8.0 (0.31)
4 x 90°
Ø 24.0
(0.94)
6.0
(0.24)
NOM 2000
(78.74)
Hydrophobic filter
(incl. in delivery)
WIRE CONNECTION
Color
Electrical connection
red
+Vs
black
-Vs
transparent
vent tube1
dimensions in mm (inches)
ORDERING INFORMATION
KTx
M
8xxx
G
4
C
x
S
x
x
calibration
E: calibration in mbar
U: calibration in psi
sealing material
V: Viton
N: NBR
mbar-ranges (only)
cable material
E: PE
U: PUR
pressure range
250:
0 to 250 mbar
400:
0 to 400 mbar
600:
0 to 600 mbar
1K0: 0 to 1000 mbar
1K6: 0 to 1600 mbar
2K0: 0 to 2000 mbar
005:
010:
015:
020:
030:
0 to 5
0 to 10
0 to 15
0 to 20
0 to 30
psi
psi
psi
psi
psi
submersible
cable length in m
cable version
output signal
4: 4...20 mA
pressure mode
G: gage pressure
Note:
Other pressure ranges and options are widely available.
Please contact your nearest Sensortechnics sales representative.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
August 2008 / 225
4/4