SENSORTECHNICS KTU6001GO7

KTE6000 / KTU6000 Series
OEM pressure transmitters for industrial media
FEATURES
· 0...-1 to 0...400 bar
0...-15 to 0...6000 psi
gage1 or absolute
· For many industrial gases and liquids
· 0...10 V, 0.5...4.5 V, 0...5 V and
4...20 mA output
· Field interchangeable
· For industrial use
MEDIA COMPATIBILITY
Wetted materials:
stainless steel 1.4404 (316L), ceramic Al2O3, NBR9,
TPE9
Housing:
stainless steel, protection class IP 65 (according to
DIN EN 60529) respectively NEMA 4X1
SPECIFICATIONS11,12
ELECTRICAL CONNECTION
Maximum ratings
0...10 V, 0.5...4.5 V, 0...5 V output
Supply voltage (reverse polarity protection)
KTx6...0
12...30 V
KTx6...6, KTx6...7
9...30 V
KTx6...42
9...30 V
Maximum load current (source)
KTx6...0, KTx6...6, KTx6...7
+Vs
sensor
3
-Vs
1 mA
2
Temperature limits
Storage
Operating
Compensated
Humidity limits
Vibration (5 to 500 Hz)
Mechanical shock
Proof pressure3
400 bar (6000 psi)
all others
December 2008 / 550
-55 to 100°C
-40 to 100°C
0 to 70°C
4...20 mA output
0 - 95 %RH
10 gRMS
50 g
12 (9) to 30 V
1
Vout
sensor
+Vs
1
N/C
3
-Vs
2
V
GND
9 to 30 V
V
RL
GND
1.5 x rated pressure
2 x rated pressure
1/6
www.sensortechnics.com
KTE6000 / KTU6000 Series
OEM pressure transmitters for industrial media
COMMON PERFORMANCE CHARACTERISTICS
VS = 15 V, RL > 100 kΩ, tamb = 25°C
Characteristics
Operating pressure
Thermal effects
(0 to 70°C)4
Thermal effects
(-40 to 0°C, 70 to 100°C)
Non-linearity, hysteresis (BSL)
and repeatability5
Min.
KTE6001...
KTE6N01G...
KTE6P01G...
KTE6002...
KTE6005...
KTE6010...
KTE6016...
KTE6020...
KTE6025...
KTE6035...
KTE6050...
KTE6070...
KTE6100...
KTE6150...
KTE6200...
KTE6300...
KTE6400...
KTU6015...
KTU6N15G...
KTU6P15G...
KTU6030...
KTU6050...
KTU6100...
KTU6200...
KTU6300...
KTU6500...
KTU61K0...
KTU61K5...
KTU62K0...
KTU63K0...
KTU64K5...
KTU66K0...
Offset
Span
Offset
Span
> 200 bar (3000 psi)
all others
Typ.
0
-1
-1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
-15
-15
0
0
0
0
0
0
0
0
0
0
0
0
0.02
0.02
0.03
0.03
±0.2
±0.1
Long term stability6
±0.3
Output noise (0 < f < 1 kHz)
±0.04
Response time (10 to 90 %)
1
Power supply rejection
Offset
Span
December 2008 / 550
KTx6...0, ...6, ...7
KTx6...4
KTx6...0, ...6, ...7
KTx6...4
0.002
0.05
0.002
0.08
Max.
1
1
0
2
5
10
16
20
25
35
50
70
100
150
200
300
400
15
15
0
30
50
100
200
300
500
1000
1500
2000
3000
4500
6000
0.05
0.05
Unit
bar
p si
%FSO/°C
±0.4
±0.3
%FSO
5
ms
%FSO/V
2/6
www.sensortechnics.com
KTE6000 / KTU6000 Series
OEM pressure transmitters for industrial media
INDIVIDUAL PERFORMANCE CHARACTERISTICS
0...10 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Min.
Typ.
Max.
Zero pressure offset
KTx6N...
all others
4.9
5
0.03
5.1
0.1
Full scale span7
KTx6N...
all others
4.9
9.9
5
10
5.1
10.1
Unit
V
25
Ω
3
5
mA
Min.
Typ.
Max.
Unit
2.450
0.450
1.950
3.950
2.5
0.5
2
4
2.550
0.550
2.050
4.050
V
25
Ω
3
5
mA
Min.
Typ.
Max.
Unit
2.45
2.5
0.03
2.5
5.0
2.55
0.08
2.55
5.05
V
25
Ω
3
5
mA
Min.
Typ.
Max.
Unit
11.9
3.9
7.9
15.9
12.0
4.0
8.0
16.0
12.1
4.1
8.1
16.1
mA
Output impedance
Current consumption (no load)
0.5...4.5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset
Full scale span7
KTx6N...
all others
KTx6N...
all others
Output impedance
Current consumption (no load)
0...5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset
Full scale span7
KTx6N...
all others
KTx6N...
all others
2.45
4.95
Output impedance
Current consumption (no load)
4...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Zero pressure offset
Full scale span7
Power consumption (IL = 20 mA)
December 2008 / 550
KTx6N...
all others
KTx6N...
all others
250
mW
3/6
www.sensortechnics.com
KTE6000 / KTU6000 Series
OEM pressure transmitters for industrial media
OUTPUT CHARACTERISTICS
0...10 V output version
0.5...4.5 V output version
10
10
Vout
V 9
8
Vout 9
V
8
7
7
KTx6N...
6
6
5
5
KTx6P...
4
KTx6N...
4
all other
3
KTx6P...
3
all other
2
2
1
1
-100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 %
operating pressure
-100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 %
operating pressure
0...5 V output version
4...20 mA output version
10
20
Vout
V 9
8
Iout 18
mA
16
7
14
6
12 KTx6P...
5
KTx6N...
10
KTx6N...
KTx6P...
4
3
8
all other
6
all other
2
4
1
2
-100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 %
operating pressure
-100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 %
operating pressure
LOAD LIMITATION
RECOMMENDED ACCESSORY
4...20 mA output version
Plug DIN EN 175301-803 A and profile washer included
in delivery. For a complete connector/cable assembly
use order no. ZK000110-x (x=cable lenghts in m).
1400
Ohm
1200
50
1000
800
34
op
e
ra ratin
ng g
e
600
400
Profile washer
M3
200
31
0
5
9
December 2008 / 550
16 20
25 30 V
supply voltage
dimensions in mm
Note:
For proper function of all gage devices the
gage port must be vented to the atmosphere
through the connector/cable assembly.
4/6
www.sensortechnics.com
KTE6000 / KTU6000 Series
OEM pressure transmitters for industrial media
OUTLINE DRAWING
KTE6...T
23 (0.90)
NOM 68 (2.68)
17
(0.67)
4.5
(0.18)
8.5 (0.33)
12
(0.47)
vent hole
27.0 (1.06)
diam.
6.0
HEX 27 (1.06)
G1/2"
(1/2" BSP)
3
1
2
KTE6...Q
12
(0.47)
4.5
(0.18)
NOM 68 (2.86)
12
(0.47)
vent hole
3
27.0 (1.06)
diam.
G1/4"
(1/4" BSP)
HEX 27 (1.06)
8.5 (0.33)
1
2
KTE6...L
17
(0.67)
4.5
(0.18)
NOM 68 (2.68)
27.0 (1.06)
diam.
3
1/4"NPT
HEX 27 (1.06)
8.5 (0.33)
vent hole
12
(0.47)
1
2
KTE6...O (flush mount)
13
(0.51)
12
(0.47)
NOM 68 (2.68)
8.5 (0.33)
vent hole
12
(0.47)
mass: 210 g
December 2008 / 550
27.0 (1.06)
diam.
G3/4"
Hex 32 (1.26)
3
2
1
dimensions in mm (inches)
5/6
www.sensortechnics.com
KTE6000 / KTU6000 Series
OEM pressure transmitters for industrial media
ELECTROMAGNETIC CAPABILITY8
Test conditions
EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz
80 % AMC (1 kHz)
Electrical fast transient / burst immunity (EFT) EN61000-4-4: Grade 3, ±2 kV
Radiated, radio frequency electromagnetic
field immunity (RFI)
Criterion
Interference
A
<1 %FSO
B
<1 %FSO
Electrostatic discharge immunity test (ESD)
EN61000-4-2: Grade 4, ±8 kV, contact discharge
B
<1 %FSO
Immunity to conducted disturbances induced
by radio-frequency fields
EN61000-4-6: Grade 3, 0.15 to 80 MHz
10 V, 80 % AMC (1 kHz)
A
<1 %FSO
Specification notes:
IP 65 protection is given when the connector is locked with a rubber washer. For proper function the gage port is vented to
the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure.
2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagram.
3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
4. Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C.
5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span.
6. Long term stability is the change in output after one year or 1 million pressure cycles.
7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure.
8. Test are in accordance with EN61000-6-2, April 1999.
9. Other sealing materials on special request.
10. Other fittings on special request.
11. CE-labelling is in accordance with 89/336/EEC.
12. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
1.
ORDERING INFORMATION
KTx6
x
x
x
Output signal
E: bar calibration
U: psi calibration
KTE6000 series
001:
0 to 1 bar
N01: -1 to +1 bar
P01: -1 to 0 bar
002:
0 to 2 bar
005:
0 to 5 bar
010:
0 to 10 bar
016:
0 to 16 bar
020:
0 to 20 bar
025:
0 to 25 bar
035:
0 to 35 bar
050:
0 to 50 bar
070:
0 to 70 bar
100:
0 to 100 bar
150:
0 to 150 bar
200:
0 to 200 bar
300:
0 to 300 bar
400:
0 to 400 bar
Note:
xxx
KTU6000 series
015:
0 to 15 psi
N15: -15 to +15 psi
P15: -15 to 0 psi
030:
0 to 30 psi
050:
0 to 50 psi
100:
0 to 100 psi
200:
0 to 200 psi
300:
0 to 300 psi
500:
0 to 500 psi
1K0: 0 to 1000 psi
1K5: 0 to 1500 psi
2K0: 0 to 2000 psi
3K0: 0 to 3000 psi
4K5: 0 to 4500 psi
6K0: 0 to 6000 psi
0:
4:
6:
7:
0...10 V
4...20 mA
0.5...4.5 V
0...5 V
Fitting size10
L:
O:
Q:
T:
1/4" NPT male
G 3/4" (3/4"BSP)
only up to 16 bar/200 psi
G 1/4" (1/4" BSP) male
G 1/2" (1/2" BSP)
Pressure mode
G:
S:
A:
gage pressure 1
(up to 50 bar/750 psi)
sealed gage
(above 50 bar/750 psi
absolute pressure
(up to 50 bar/750 psi)
Other pressure ranges and options are widely available.
Please contact your nearest Sensortechnics sales representative.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
December 2008 / 550
6/6
www.sensortechnics.com