POWER-ONE LES015YH

LES SERIES - 15 WATT
DESCRIPTION
FEATURES
LES DC/DC converters provide up to 15 Watts of output
power in an industry standard package and footprint. With
a maximum case temperature of 100°C, the LES is well
suited for the most demanding telecom, networking, and
industrial applications. The LES features 1500 VDC
isolation, short circuit, and overtemperature protection, as
well as six-sided shielding. The LES is available with
optional enable and voltage trim pins. Please see the IAD
Series for dual output applications.
•
•
•
•
Industry Standard Package
Industry Standard Pinout
85°C Case Operation
Short Circuit Protection
• 24V and 48V Inputs
• Input Pi Filter and
6-Sided Shielding
• Regulated Outputs
• 1500V Isolation
Efficiency vs. Load (24V Input)
85
80
EFFICIENCY %
75
TECHNICAL SPECIFICATIONS
70
LES010YE-A
65
EFF. (18v)
60
EFF. (24v)
55
EFF. (36v)
50
Input
Voltage Range
24 VDC Nominal
48 VDC Nominal
Reflected Ripple
45
10
18 - 36 VDC
36 - 75 VDC
50 mA
40
50
60
70
80
90
100
Efficiency vs. Load (48V Input)
±1%
0.2% Vout
Load Regulation Iout Min. - Iout Max., Vin Nom.
0.5% Vout
Minimum Output Current
10% Iout Rated
Dynamic Regulation, Loadstep
25% Iout
Pk Deviation
2% Vout
500 µs
±10%
Shutdown / Hiccup
110 - 150%
Settling Time
Voltage Trim Range
Short Circuit / Overcurrent Protection
Current Limit Threshold Range, % of Iout Rated
Short Circuit Current Max.
(12Vout & 15Vout : 4.0A when Vout= 0.25V)
85
80
75
EFFICIENCY %
Setpoint Accuracy
Line Regulation Vin Min. - Vin Max., Iout Rated
70
LES010ZE
65
LES015ZG
60
55
50
10
20
30
40
50
Second Control Loop
Notes
† MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
Rev. 06/01
1
70
80
90
100
General
Turn-On Time
Remote Shutdown
Switching Frequency
Isolation
Input - Output
Output - Case
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
MTBF† (Bellcore TR-NWT-000332)
Safety
Units are water-washable and fully compatible with commercial spray or immersion
post wave-solder washing equipment.
60
LOAD %
200% Iout
115 -140% Vout Nom.
OVP Type
30
LOAD %
Output
OVP Trip Range
20
10 mS
Positive/Negative Logic
400 kHz
1500 VDC
500 VDC
0.02 ppm/°C
-40 To +100°C
-40 To +100°C
95%
5 g, 10 - 55 Hz
2.5 X 106 hrs
UL, cUL, TUV
LES SERIES - 15 WATT
MODELS - (See the last page of section for options.)
SINGLE OUTPUT MODEL SELECTION CHART
INPUT VOLTAGE
(VOLTS)
INPUT VOLTAGE
RANGE (VOLTS)
MAXIMUM INPUT
CURRENT (AMPS)*
OUTPUT
VOLTAGE (VOLTS)
RATED OUTPUT
CURRENT (AMPS)
LES008YD
LES010YE
LES015YG
24
24
24
18-36
18-36
18-36
0.6
0.8
1.1
2.5
3.3
5
3.00
3.00
3.00
75
100
100
77%
81%
84%
LES015YH
24
18-36
1.3
12
1.25
120
85%
LES015YJ
24
18-36
1.3
15
1.00
150
86%
LES006ZB
48
36-75
0.25
1.8
3.00
75
73%
LES008ZD
48
36-75
0.35
2.5
3.00
75
77%
LES010ZE
48
36-75
0.4
3.3
3.00
100
81%
LES015ZG
48
36-75
0.6
5
3.00
100
83%
LES020ZG
48
40-60
0.63
5
4.00
100
84%
LES015ZH
48
36-75
0.65
12
1.25
120
86%
LES015ZJ
48
36-75
0.65
15
1.00
150
86%
MODEL
NOTES:
RIPPLE & NOISE
pk-pk (mV)
TYPICAL
EFFICIENCY**
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
MECHANICAL DRAWING
Thermal Impedance
Natural Convection
100 LFM
200 LFM
300 LFM
400 LFM
15.4 °C/W
12.2 °C/W
9.3 °C/W
7.4 °C/W
6.4 °C/W
Pin
1
+Vin
2
-Vin
3
4
Tolerances
Function
No Pin
(Optional Shutdown Pin)
+Vout
5
No Pin
(Optional Trim Pin)
-Vout
6
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated
for specific application.
Inches:
.XX ± 0.020
.XXX ± 0.010
(Millimeters)
.X ± 0.5
.XX ± 0.25
Pin:
± 0.002
± 0.05
Case:
+ 0.04, - 0.00
+ 1.0, - 0.00
(Dimensions as listed unless otherwise
specified.)
2
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that you prefer
and add them to the model number. Example ordering options are located below the options table.
OPTION
SUFFIX
APPLICABLE SERIES
Negative Logic
N
HAS, HBD, HBS, HES, HLS, HLD, LES,
QBS, QES, QLS, TES, TQD
Lucent-Compatible
T
HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Terminal Strip
TS
XWS, XWD, XWT
Trim
1
IAS, LES
Enable
2
IAD, IAS, LES, SMS
Trim and Enable
3
IAS, LES
Current Share
4
SMS
Headerless
Y
Encapsulated EWS, IWS, OWS
Pin Length and Heatsink Options
REMARKS
TTL "Low" Turns Module ON
TTL "High" Turns Module OFF
Standard Pin Length is 0.180" (4.6mm)
0.110" (2.8mm) Pin Length
8
All Units (Except SMS)
0.150" (3.8mm) Pin Length
9
All Units (Except SMS)
0.24" (6.1mm) Horizontal Heatsink
1H
All Units (All Units Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
Includes Thermal Pad
0.24" (6.1mm) Vertical Heatsink
1V
All Units (All Units Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
Includes Thermal Pad
0.45" (11.4mm) Horizontal Heatsink
2H
All Units (All Units Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
Includes Thermal Pad
0.45" (11.4mm) Vertical Heatsink
2V
All Units (All Units Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
Includes Thermal Pad
0.95" (24.1mm) Horizontal Heatsink
3H
All Units (All Units Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
Includes Thermal Pad
0.95" (24.1mm) Vertical Heatsink
3V
All Units (All Units Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
Includes Thermal Pad
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
3