NSC LM20SIBP

LM20
2.4V, 10µA, SC70, micro SMD Temperature Sensor
General Description
The LM20 is a precision analog output CMOS integratedcircuit temperature sensor that operates over a −55˚C to
+130˚C temperature range. The power supply operating
range is +2.4 V to +5.5 V. The transfer function of LM20 is
predominately linear, yet has a slight predictable parabolic
curvature. The accuracy of the LM20 when specified to a
parabolic transfer function is ± 1.5˚C at an ambient temperature of +30˚C. The temperature error increases linearly and
reaches a maximum of ± 2.5˚C at the temperature range
extremes. The temperature range is affected by the power
supply voltage. At a power supply voltage of 2.7 V to 5.5 V
the temperature range extremes are +130˚C and −55˚C.
Decreasing the power supply voltage to 2.4 V changes the
negative extreme to −30˚C, while the positive remains at
+130˚C.
The LM20’s quiescent current is less than 10 µA. Therefore,
self-heating is less than 0.02˚C in still air. Shutdown capability for the LM20 is intrinsic because its inherent low power
consumption allows it to be powered directly from the output
of many logic gates or does not necessitate shutdown at all.
n
n
n
n
n
n
Battery Management
FAX Machines
Printers
HVAC
Disk Drives
Appliances
Features
n
n
n
n
Rated for full −55˚C to +130˚C range
Available in an SC70 and 2 micro SMD packages
Predictable curvature error
Suitable for remote applications
Key Specifications
j Accuracy at +130˚C & −55˚C
± 1.5 to ± 4 ˚C (max)
± 2.5 to ± 5 ˚C (max)
j Power Supply Voltage Range
+2.4V to +5.5V
j Accuracy at +30˚C
j Current Drain
10 µA (max)
j Nonlinearity
± 0.4 % (typ)
Applications
j Output Impedance
160 Ω (max)
n Cellular Phones
n Computers
n Power Supply Modules
j Load Regulation
0 µA < IL < +16 µA
−2.5 mV (max)
Typical Application
Full-Range Celsius (Centigrade) Temperature Sensor (−55˚C to +130˚C)
Operating from a Single Li-Ion Battery Cell
Output Voltage vs Temperature
10090802
VO = (−3.88x10−6xT2) + (−1.15x10−2xT) + 1.8639
10090824
where:
T is temperature, and VO is the measured output voltage of the LM20.
© 2005 National Semiconductor Corporation
DS100908
www.national.com
LM20 2.4V, 10µA, SC70, micro SMD Temperature Sensor
October 2005
LM20
Typical Application
(Continued)
Temperature (T)
Typical VO
+130˚C
+303 mV
+100˚C
+675 mV
+80˚C
+919 mV
+30˚C
+1515 mV
+25˚C
+1574 mV
0˚C
+1863.9 mV
−30˚C
+2205 mV
−40˚C
+2318 mV
−55˚C
+2485 mV
Connection Diagrams
SC70-5
micro SMD
10090801
Note:
10090832
- GND (pin 2) may be grounded or left floating. For optimum thermal
conductivity to the pc board ground plane pin 2 should be grounded.
Note:
- NC (pin 1) should be left floating or grounded. Other signal traces
should not be connected to this pin.
-
Pin numbers are referenced to the package marking text orientation.
-
Reference JEDEC Registration MO-211, variation BA
- The actual physical placement of package marking will vary slightly from
part to part. The package marking will designate the date code and will vary
considerably. Package marking does not correlate to device type in any way.
Top View
See NS Package Number MAA05A
Top View
See NS Package Number BPA04DDC, TPA04EEA and
TLA04ZZA
Ordering Information
Order
Temperature
Temperature
NS Package
Device
Number
Accuracy
Range
Number
Marking
−55˚C to +130˚C
MAA05A
T2B
−55˚C to +130˚C
MAA05A
T2B
3000 Units on Tape and Reel
−55˚C to +130˚C
MAA05A
T2C
1000 Units on Tape and Reel
−55˚C to +130˚C
MAA05A
T2C
3000 Units on Tape and Reel
LM20SIBP
± 2.5˚C
± 2.5˚C
± 5˚C
± 5˚C
± 3.5˚C
−40˚C to +125˚C
BPA04DDC
Date
Code
250 Units on Tape and Reel
LM20SIBPX
± 3.5˚C
−40˚C to +125˚C
BPA04DDC
Date
Code
3000 Units on Tape and Reel
LM20SITL
± 3.5˚C
−40˚C to +125˚C
TLA04ZZA
Date
Code
250 Units on Tape and Reel
LM20SITLX
± 3.5˚C
−40˚C to +125˚C
TLA04ZZA
Date
Code
3000 Units on Tape and Reel
LM20SITP
± 3.5˚C
−40˚C to +125˚C
TPA04EEA
Date
Code
250 Units on Tape and Reel
LM20SITPX
± 3.5˚C
−40˚C to +125˚C
TPA04EEA
Date
Code
3000 Units on Tape and Reel
LM20BIM7
LM20BIM7X
LM20CIM7
LM20CIM7X
www.national.com
2
Transport Media
1000 Units on Tape and Reel
Supply Voltage
+6.5V to −0.2V
Output Voltage
(V+ + 0.6 V) to
−0.6 V
Output Current
10 mA
Operating Ratings(Note 1)
TMIN ≤ TA ≤ TMAX
Specified Temperature Range:
LM20B, LM20C with
2.4 V ≤ V+≤ 2.7 V
−30˚C ≤ TA ≤ +130˚C
5 mA
LM20B, LM20C with
2.7 V ≤ V+≤ 5.5 V
−55˚C ≤ TA ≤ +130˚C
−65˚C to
+150˚C
LM20S with
2.4 V ≤ V+≤ 5.5 V
−30˚C ≤ TA ≤ +125˚C
+150˚C
LM20S with
2.7 V ≤ V+≤ 5.5 V
−40˚C ≤ TA ≤ +125˚C
Input Current at any pin (Note 2)
Storage Temperature
LM20
Absolute Maximum Ratings (Note 1)
Maximum Junction Temperature
(TJMAX)
Supply Voltage Range (V+)
ESD Susceptibility (Note 3) :
Human Body Model
2500 V
Machine Model
+2.4 V to +5.5 V
Thermal Resistance, θJA(Note 5)
SC-70
micro SMD
250 V
Soldering process must comply with National’s
Reflow Temperature Profile specifications. Refer to
www.national.com/packaging. (Note 4)
415˚C/W
340˚C/W
Electrical Characteristics
Unless otherwise noted, these specifications apply for V+ = +2.7 VDC. Boldface limits apply for TA = TJ = TMIN to TMAX ; all
other limits TA = TJ = 25˚C; Unless otherwise noted.
Parameter
Temperature to Voltage Error
VO = (−3.88x10−6xT2)
+ (−1.15x10−2xT) + 1.8639V
(Note 8)
Conditions
Typical
(Note 6)
TA = +25˚C to +30˚C
TA = +130˚C
TA = +125˚C
TA = +100˚C
TA = +85˚C
TA = +80˚C
TA = 0˚C
TA = −30˚C
TA = −40˚C
TA = −55˚C
LM20B
LM20C
LM20S
Limits
Limits
Limits
(Note 7)
(Note 7)
(Note 7)
± 1.5
± 2.5
± 2.5
± 2.2
± 2.1
± 2.0
± 1.9
± 2.2
± 2.3
± 2.5
± 4.0
± 5.0
± 5.0
± 4.7
± 4.6
± 4.5
± 4.4
± 4.7
± 4.8
± 5.0
± 2.5
Units
(Limit)
˚C (max)
˚C (max)
± 3.5
± 3.2
± 3.1
± 3.0
± 2.9
± 3.3
± 3.5
˚C (max)
˚C (max)
˚C (max)
˚C (max)
˚C (max)
˚C (min)
˚C (max)
˚C (max)
Output Voltage at 0˚C
+1.8639
V
Variance from Curve
˚C
Non-Linearity (Note 9)
−20˚C ≤ TA ≤ +80˚C
± 1.0
± 0.4
Sensor Gain (Temperature
Sensitivity or Average Slope)
to equation:
VO=−11.77 mV/˚CxT+1.860V
−30˚C ≤ TA ≤ +100˚C
−11.77
Output Impedance
%
−11.4
−12.2
−11.0
−12.6
−11.0
−12.6
mV/˚C (min)
mV/˚C (max)
0 µA ≤ IL ≤ +16 µA
(Notes 11, 12)
160
160
160
Ω (max)
Load Regulation(Note 10)
0 µA ≤ IL ≤ +16 µA
(Notes 11, 12)
−2.5
−2.5
−2.5
mV (max)
Line Regulation
+2. 4 V ≤ V+ ≤ +5.0V
+3.3
+3.7
+3.7
mV/V (max)
+5.0 V ≤ V+ ≤ +5.5 V
+11
+11
+11
mV (max)
7
7
7
µA (max)
Quiescent Current
Change of Quiescent Current
+2. 4V ≤ V+ ≤ +5.0V
4.5
+
+5.0V ≤ V ≤ +5.5V
4.5
9
9
9
µA (max)
+2. 4V ≤ V+ ≤ +5.0V
4.5
10
10
10
µA (max)
+2. 4 V ≤ V+ ≤ +5.5V
+0.7
µA
−11
nA/˚C
0.02
µA
Temperature Coefficient of
Quiescent Current
Shutdown Current
V+ ≤ +0.8 V
3
www.national.com
LM20
Electrical Characteristics
(Continued)
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed
specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test
conditions.
Note 2: When the input voltage (VI) at any pin exceeds power supplies (VI < GND or VI > V+), the current at that pin should be limited to 5 mA.
Note 3: The human body model is a 100 pF capacitor discharged through a 1.5 kΩ resistor into each pin. The machine model is a 200 pF capacitor discharged
directly into each pin.
Note 4: Reflow temperature profiles are different for lead-free and non-lead-free packages.
Note 5: The junction to ambient thermal resistance (θJA) is specified without a heat sink in still air using the printed circuit board layout shown in Figure 1.
Note 6: Typicals are at TJ = TA = 25˚C and represent most likely parametric norm.
Note 7: Limits are guaranteed to National’s AOQL (Average Outgoing Quality Level).
Note 8: Accuracy is defined as the error between the measured and calculated output voltage at the specified conditions of voltage, current, and temperature
(expressed in˚C).
Note 9: Non-Linearity is defined as the deviation of the calculated output-voltage-versus-temperature curve from the best-fit straight line, over the temperature
range specified.
Note 10: Regulation is measured at constant junction temperature, using pulse testing with a low duty cycle. Changes in output due to heating effects can be
computed by multiplying the internal dissipation by the thermal resistance.
Note 11: Negative currents are flowing into the LM20. Positive currents are flowing out of the LM20. Using this convention the LM20 can at most sink −1 µA and
source +16 µA.
Note 12: Load regulation or output impedance specifications apply over the supply voltage range of +2.4V to +5.5V.
Note 13: Line regulation is calculated by subtracting the output voltage at the highest supply input voltage from the output voltage at the lowest supply input voltage.
Typical Performance Characteristics
Temperature Error vs Temperature
10090825
PCB Layouts Used for Thermal Measurements
10090830
10090829
b) Layout used for measurements with small heat hink.
a) Layout used for no heat sink measurements.
FIGURE 1. PCB Lyouts used for thermal measurements.
Over the full operating temperature range of −55˚C to
+130˚C, best accuracy can be obtained by using the parabolic transfer function
VO = (−3.88x10−6xT2) + (−1.15x10−2xT) + 1.8639
solving for T:
1.0 LM20 Transfer Function
The LM20’s transfer function can be described in different
ways with varying levels of precision. A simple linear transfer
function, with good accuracy near 25˚C, is
VO= −11.69 mV/˚C x T + 1.8663 V
www.national.com
4
and
m = −11.77 mV/˚C
The offset of the linear transfer function can be calculated
using the following equation:
b = (VOP(Tmax) + VOP(T) + m x (Tmax+T))/2
(Continued)
,
where:
A linear transfer function can be used over a limited temperature range by calculating a slope and offset that give best
results over that range. A linear transfer function can be
calculated from the parabolic transfer function of the LM20.
The slope of the linear transfer function can be calculated
using the following equation:
m = −7.76 x 10−6x T − 0.0115,
• VOP(Tmax) is the calculated output voltage at Tmax using
the parabolic transfer function for VO
• VOP(T) is the calculated output voltage at T using the
parabolic transfer function for VO.
Using this procedure the best fit linear transfer function for
many popular temperature ranges was calculated in Figure
2. As shown in Figure 2 the error that is introduced by the
linear transfer function increases with wider temperature
ranges.
where T is the middle of the temperature range of interest
and m is in V/˚C. For example for the temperature range of
Tmin=−30 to Tmax=+100˚C:
T=35˚C
Temperature Range
Tmin (˚C)
Tmax (˚C)
Linear Equation
VO=
Maximum Deviation of Linear Equation
from Parabolic Equation (˚C)
± 1.41
± 0.93
± 0.70
± 0.65
± 0.23
± 0.004
± 0.004
−55
+130
−11.79 mV/˚C x T + 1.8528 V
−40
+110
−11.77 mV/˚C x T + 1.8577 V
−30
+100
−11.77 mV/˚C x T + 1.8605 V
-40
+85
−11.67 mV/˚C x T + 1.8583 V
−10
+65
−11.71 mV/˚C x T + 1.8641 V
+35
+45
−11.81 mV/˚C x T + 1.8701 V
+20
+30
−11.69 mV/˚C x T + 1.8663 V
FIGURE 2. First order equations optimized for different temperature ranges.
perature due to its power dissipation. For the LM20 the
equation used to calculate the rise in the die temperature is
as follows:
TJ = TA + θJA [(V+ IQ) + (V+ − VO) IL]
2.0 Mounting
The LM20 can be applied easily in the same way as other
integrated-circuit temperature sensors. It can be glued or
cemented to a surface. The temperature that the LM20 is
sensing will be within about +0.02˚C of the surface temperature to which the LM20’s leads are attached to.
This presumes that the ambient air temperature is almost the
same as the surface temperature; if the air temperature were
much higher or lower than the surface temperature, the
actual temperature measured would be at an intermediate
temperature between the surface temperature and the air
temperature.
To ensure good thermal conductivity the backside of the
LM20 die is directly attached to the pin 2 GND pin. The
tempertures of the lands and traces to the other leads of the
LM20 will also affect the temperature that is being sensed.
Alternatively, the LM20 can be mounted inside a sealed-end
metal tube, and can then be dipped into a bath or screwed
into a threaded hole in a tank. As with any IC, the LM20 and
accompanying wiring and circuits must be kept insulated and
dry, to avoid leakage and corrosion. This is especially true if
the circuit may operate at cold temperatures where condensation can occur. Printed-circuit coatings and varnishes such
as Humiseal and epoxy paints or dips are often used to
ensure that moisture cannot corrode the LM20 or its connections.
The thermal resistance junction to ambient (θJA) is the parameter used to calculate the rise of a device junction tem-
where IQ is the quiescent current and ILis the load current on
the output. Since the LM20’s junction temperature is the
actual temperature being measured care should be taken to
minimize the load current that the LM20 is required to drive.
The tables shown in Figure 3 summarize the rise in die
temperature of the LM20 without any loading, and the thermal resistance for different conditions.
5
www.national.com
LM20
1.0 LM20 Transfer Function
LM20
2.0 Mounting
300 pF as shown in Figure 4. Over the specified temperature
range the LM20 has a maximum output impedance of 160 Ω.
In an extremely noisy environment it may be necessary to
add some filtering to minimize noise pickup. It is recommended that 0.1 µF be added from V+ to GND to bypass the
power supply voltage, as shown in Figure 5. In a noisy
environment it may even be necessary to add a capacitor
from the output to ground with a series resistor as shown in
Figure 5. A 1 µF output capacitor with the 160 Ω maximum
output impedance and a 200 Ω series resistor will form a 442
Hz lowpass filter. Since the thermal time constant of the
LM20 is much slower, the overall response time of the LM20
will not be significantly affected.
(Continued)
SC70-5
SC70-5
no heat sink
small heat sink
θJA
TJ − T A
θJA
(˚C/W)
(˚C)
(˚C/W)
(˚C)
Still air
412
0.2
350
0.19
Moving air
312
0.17
266
0.15
T J − TA
See Figure 1 for PCB layout samples.
micro SMD
micro SMD
no heat sink
small heat fin
θJA
TJ − T A
θJA
(˚C/W)
(˚C)
(˚C/W)
(˚C)
Still air
340
0.18
TBD
TBD
Moving air
TBD
TBD
TBD
TBD
T J − TA
10090815
FIGURE 3. Temperature Rise of LM20 Due to
Self-Heating and Thermal Resistance (θJA)
FIGURE 4. LM20 No Decoupling Required for
Capacitive Loads Less than 300 pF.
3.0 Capacitive Loads
The LM20 handles capacitive loading well. Without any precautions, the LM20 can drive any capacitive load less than
R (Ω)
C (µF)
200
1
470
0.1
680
0.01
1k
0.001
10090816
10090833
FIGURE 5. LM20 with Filter for Noisy Environment and Capacitive Loading greater than 300 pF. Either placement of
resistor as shown above is just as effective.
either case it is recommended that the LM20 micro SMD be
placed inside an enclosure of some type that minimizes its
light exposure. Most chassis provide more than ample protection. The LM20 does not sustain permanent damage from
light exposure. Removing the light source will cause LM20’s
output voltage to recover to the proper value.
4.0 LM20 micro SMD Light
Sensitivity
Exposing the LM20 micro SMD package to bright sunlight
may cause the output reading of the LM20 to drop by 1.5V. In
a normal office environment of fluorescent lighting the output
voltage is minimally affected (less than a millivolt drop). In
www.national.com
6
LM20
5.0 Applications Circuits
10090818
FIGURE 6. Centigrade Thermostat
10090819
FIGURE 7. Conserving Power Dissipation with Shutdown
10090828
Most CMOS ADCs found in ASICs have a sampled data comparator input structure that is notorious for causing grief to analog
output devices such as the LM20 and many op amps. The cause of this grief is the requirement of instantaneous charge of the
input sampling capacitor in the ADC. This requirement is easily accommodated by the addition of a capacitor. Since not all ADCs
have identical input stages, the charge requirements will vary necessitating a different value of compensating capacitor. This ADC
is shown as an example only. If a digital output temperature is required please refer to devices such as the LM74.
FIGURE 8. Suggested Connection to a Sampling Analog to Digital Converter Input Stage
7
www.national.com
LM20
Physical Dimensions
inches (millimeters) unless otherwise noted
5-Lead SC70 Molded Package
Order Number LM20BIM7 or LM20CIM7X
NS Package Number MAA05A
4-Bump micro SMD Ball Grid Array Package (Small Bump)
Order Number LM20SIBP or LM20SIBPX
NS Package Number BPA04DDC
The following dimensions apply to the BPA04DDC package
shown above: X1=X2 = 853µm ± 30µm, X3= 900µm ± 50µm
www.national.com
8
LM20
Physical Dimensions
inches (millimeters) unless otherwise noted (Continued)
4-Bump micro SMD Ball Grid Array Package (Large Bump)
Order Number LM20SITL or LM20SITLX
NS Package Number TLA04ZZA
The following dimensions apply to the TLA04ZZA package
shown above: X1=X2 = 963µm ± 30µm, X3= 600µm ± 75µm
9
www.national.com
LM20 2.4V, 10µA, SC70, micro SMD Temperature Sensor
Physical Dimensions
inches (millimeters) unless otherwise noted (Continued)
4-Bump Thin micro SMD Ball Grid Array Package (Small Bump)
Order Number LM20SITP or LM20SITPX
NS Package Number TPA04EEA
The following dimensions apply to the TPA04EEA package
shown above: X1 = X2 = 879µm ± 30µm X3 = 500µm ± 75µm
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves
the right at any time without notice to change said circuitry and specifications.
For the most current product information visit us at www.national.com.
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS
WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR
CORPORATION. As used herein:
1. Life support devices or systems are devices or systems
which, (a) are intended for surgical implant into the body, or
(b) support or sustain life, and whose failure to perform when
properly used in accordance with instructions for use
provided in the labeling, can be reasonably expected to result
in a significant injury to the user.
2. A critical component is any component of a life support
device or system whose failure to perform can be reasonably
expected to cause the failure of the life support device or
system, or to affect its safety or effectiveness.
BANNED SUBSTANCE COMPLIANCE
National Semiconductor manufactures products and uses packing materials that meet the provisions of the Customer Products
Stewardship Specification (CSP-9-111C2) and the Banned Substances and Materials of Interest Specification (CSP-9-111S2) and contain
no ‘‘Banned Substances’’ as defined in CSP-9-111S2.
Leadfree products are RoHS compliant.
National Semiconductor
Americas Customer
Support Center
Email: [email protected]
Tel: 1-800-272-9959
www.national.com
National Semiconductor
Europe Customer Support Center
Fax: +49 (0) 180-530 85 86
Email: [email protected]
Deutsch Tel: +49 (0) 69 9508 6208
English Tel: +44 (0) 870 24 0 2171
Français Tel: +33 (0) 1 41 91 8790
National Semiconductor
Asia Pacific Customer
Support Center
Email: [email protected]
National Semiconductor
Japan Customer Support Center
Fax: 81-3-5639-7507
Email: [email protected]
Tel: 81-3-5639-7560