MEANWELL LPF-16-54

LPF-16
16W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range (up to 305VAC)
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
Cooling by free air convection
Fully isolated plastic case
Class power unit, no FG
Class 2 power unit
IP67(optional , model NO. : LPF-16-12 P)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp locations(wet location for LPF-16-12 P)
3 years warranty
F
110
M
M
SPECIFICATION
MODEL
DC VOLTAGE
LPF-16-15
LPF-16-20
LPF-16-24
LPF-16-30
LPF-16-36
LPF-16-42
LPF-16-48
LPF-16-54
12V
15V
20V
24V
30V
36V
42V
48V
54V
7.5 ~ 15V
10 ~ 20V
12 ~ 24V
18 ~ 36V
21 ~ 42V
24 ~ 48V
27 ~ 54V
0.45A
0.39A
0.34A
0.3A
RATED CURRENT
1.34A
1.07A
0.8A
0.67A
RATED POWER
16.08W
16.05W
16W
16.08W
16.2W
16.2W
16.38W
16.32W
16.2W
150mVp-p
150mVp-p
150mVp-p
200mVp-p
250mVp-p
250mVp-p
250mVp-p
350mVp-p
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE TOLERANCE Note.3
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
Note.6 1500ms, 80ms / 115VAC at full load
16ms at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5 90 ~ 305VAC
47 ~ 63Hz
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
84%
86%
84%
0.4A / 115VAC
0.2A / 230VAC
COLD START 50A/230VAC
OVER CURRENT
Note.4
SHORT CIRCUIT
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
86%
86%
86%
86%
54 ~ 63V
59 ~ 66V
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
34 ~ 40V
15 ~ 18V
17.5 ~ 21V 23 ~ 27V
28 ~ 35V
41 ~ 49V
46 ~ 54V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
100J Ó 5J( TSW1) Detect on U2
Protection type : Shut down o/p voltage, recover automatically after temperature goes down
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
0.03%/
, 10 ~ 95% RH
(0 ~ 50
)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V),EN61347-1, EN61347-2-13 independent approved, IP67 (optional) ; Design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015; EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
DIMENSION
PACKING
NOTE
86%
SAFETY STANDARDS
EMC IMMUNITY
MTBF
OTHERS
86%
<0.75mA / 240VAC
OVER VOLTAGE
EMC
230VAC /115VAC
127 ~ 431VDC
POWER FACTOR (Typ.)
LEAKAGE CURRENT
SAFETY &
1500ms, 80ms / 230VAC
FREQUENCY RANGE
AC CURRENT
INRUSH CURRENT (Typ.)
PROTECTION
( except for 48V,54V )
15 ~ 30V
0.54A
SETUP, RISE TIME
INPUT
( for 48V,54V only)
LPF-16-12
CONSTANT CURRENT REGION Note.4 6 ~12V
OUTPUT
SELV
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547,light industry level(surge 2KV), criteria A
473.3Khrs min. MIL-HDBK-217F (25
148*40*32mm (L*W*H)
0.21Kg; 40pcs/9.4Kg/1.02CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:LPF-16-SPEC 2011-12-21
LPF-16
16W Single Output Switching Power Supply
Mechanical Specification
Case No. : LPF-16A
148
300 20
series
Unit:mm
300 20
SJTW 18AWG
3.6
SVT 18AWG*2C
T case
+V(Red)
-V(Black)
60
13
40
3.6
3.5
AC/N(Blue)
AC/L(Brown)
3.5
3.5
3.5
32
T case: Max. Case Temperature.
Block Diagram
Fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
+V
-V
O.L.P.
O.L.P.
DETECTION
CIRCUIT
PWM & PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
230VAC
Input only
70
LOAD (%)
LOAD (%)
60
40
20
-40
-30
-15
0
15
30
AMBIENT TEMPERATURE (
50
)
60
70
(HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
305
INPUT VOLTAGE (V) 60Hz
File Name:LPF-16-SPEC 2011-12-21
16W Single Output Switching Power Supply
LPF-16
series
Power Factor Characteristic
Constant Current Mode
PF
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
.9 9
.9 8
.9 7
.9 6
.9 5
.9 4
.9 3
.9 2
.9 1
0 .9
.8 9
.8 8
.8 7
.8 6
.8 5
.8 4
277VAC
230VAC
115VAC
50%
60%
70%
80%
90%
100%
(16W)
LOAD
EFFICIENCY vs LOAD (48V Model)
EFFICIENCY (%)
LPF-16 series possess superior working efficiency that up to 86% can be reached in field applications.
93
92
91
90
89
88
87
86
85
84
83
82
81
80
79
78
77
76
75
74
73
72
71
70
277VAC
230VAC
115VAC
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method "direct drive" and "with LED driver".
A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
(B)
Constant
Current area
Vo(%)
100
(A)
Constant
Voltage area
50
(max.)
(C)
Hiccup
Protection
50
95
Io(%)
Typical LED power supply I-V curve
File Name:LPF-16-SPEC 2011-12-21