MEANWELL LPF-60D-48

LPF-60D
60W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 90%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Fully isolated plastic case
Fully encapsulated with IP67 level (Note.6)
Class
power unit, no FG
Class 2 power unit
Built-in 3 in 1 dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
F
110
M
M
IP67
SELV
( for 48V,54V only)
( except for 48V,54V )
SPECIFICATION
LPF-60D-12 LPF-60D-15 LPF-60D-20 LPF-60D-24 LPF-60D-30 LPF-60D-36 LPF-60D-42 LPF-60D-48 LPF-60D-54
MODEL
12V
DC VOLTAGE
CONSTANT CURRENT REGION Note.4 7.2 ~12V
OUTPUT
24V
30V
36V
42V
48V
54V
12 ~ 20V
14.4 ~ 24V
21.6 ~ 36V
25.2 ~ 42V
28.8 ~ 48V
32.4 ~ 54V
1.67A
1.43A
1.25A
1.12A
RATED CURRENT
5A
4A
3A
2.5A
RATED POWER
60W
60W
60W
60W
60W
60.12W
60.06W
60W
60.48W
150mVp-p
150mVp-p
150mVp-p
200mVp-p
250mVp-p
250mVp-p
250mVp-p
350mVp-p
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE TOLERANCE Note.3
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
Note.7 1000ms, 80ms / 115VAC at full load
16ms/230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5 90 ~ 305VAC
1000ms, 80ms / 230VAC
16ms/115VAC at full load
127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
86%
88%
87%
0.8A / 115VAC
0.4A / 230VAC
COLD START 75A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
OVER CURRENT
89%
90%
90%
Note.4
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS Note.6
41 ~ 49V
90
DIMENSION
PACKING
NOTE
54 ~ 63V
59 ~ 66V
10
(RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +70
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
0.03%/
, 10 ~ 95% RH
(0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.0-08(except for 48V, 54V), EN61347-1, EN61347-2-13 independent, IP67, J61347-1, J61347-2-13
approved ; design refer to UL60950-1, TUV EN60950-1
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
ISOLATION RESISTANCE
46 ~ 54V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
EMC
OTHERS
90%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
34 ~ 40V
15 ~ 17V
17.5 ~ 21V 23 ~ 27V
28 ~ 35V
I/P-O/P:3.75KVAC
EMC IMMUNITY
MTBF
90%
95 ~ 108%
SAFETY & WITHSTAND VOLTAGE
EMC EMISSION
90%
<0.75mA / 240VAC
LEAKAGE CURRENT
PROTECTION
20V
9 ~ 15V
18 ~ 30V
2A
SETUP, RISE TIME
INPUT
15V
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level(surge 2KV), criteria A
396.7Khrs min. MIL-HDBK-217F (25 )
162.5*43*32mm (L*W*H)
0.45Kg; 32pcs/15.4Kg/0.93CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:LPF-60D-SPEC 2012-03-20
LPF-60D
60W Single Output Switching Power Supply
Mechanical Specification
Case No.LPF-60B
series
Unit:mm
162.5
3.5
300 20
3.6
T case
3.5
300 20
60
13
3.5
SJTW 18AWG 2C
43
3.6
AC/N(Blue)
AC/L(Brown)
UL2464 18AWG 2C(+V,-V)
UL2464 22AWG 2C(DIM+,DIM-)
3.5
+V(Red)
-V(Black)
DIM+(Blue)
DIM-(White)
32
T case: Max. Case Temperature.
Block Diagram
Fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
+V
-V
DIM+
DIM-
O.L.P.
O.L.P.
DETECTION
CIRCUIT
PWM & PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
230VAC
Input only
70
50
LOAD (%)
LOAD (%)
60
40
20
-40
-30
0
15
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
305
INPUT VOLTAGE (V) 60Hz
File Name:LPF-60D-SPEC 2012-03-20
60W Single Output Switching Power Supply
LPF-60D
series
Power Factor Characteristic
Constant Current Mode
PF
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
.9 9
.9 8
.9 7
.9 6
.9 5
.9 4
.9 3
.9 2
.9 1
0 .9
.8 9
.8 8
.8 7
.8 6
.8 5
.8 4
277VAC
230VAC
115VAC
50%
60%
70%
80%
90%
100%
(60W)
LOAD
EFFICIENCY vs LOAD (48V Model)
LPF-60D series possess superior working efficiency that up to 90% can be reached in field applications.
EFFICIENCY (%)
93
92
91
90
89
88
87
86
85
84
83
82
81
80
79
78
277VAC
230VAC
115VAC
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method "direct drive" and "with LED driver".
A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
(B)
Constant
Current area
Vo(%)
100
(A) Constant
Voltage area
60
(max.)
(C)
Hiccup
Protection
50
95
Io (%)
Typical LED power supply I-V curve
File Name:LPF-60D-SPEC 2012-03-20
LPF-60D
60W Single Output Switching Power Supply
series
DIMMING OPERATION
AC/N(Blue)
AC/L(Brown)
+V(Red)
-V(Black)
DIM+(Blue)
DIM-(White)
LPF-60D
Built-in 3 in 1 dimming function, o utput constant current level can be adjusted through output cable by 1 ~ 10Vdc, 10V PWM signal or resistance
between DIM+ and DIM-.
Please DO NOT connect "DIM-" to "-V".
Reference resistance value for output current adjustment (Typical)
Resistance value
Output current
10K
20K
10%
20%
30K
30%
40K
40%
50K
60K
50%
70K
80K
90K
100K
OPEN
60%
70%
80%
90%
100%
100%~108%
1 ~ 10V dimming function for output current adjustment (Typical)
Dimming value
1V
2V
3V
4V
5V
6V
7V
8V
9V
10V
OPEN
Output current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
100%~108%
10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz
Duty value
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
OPEN
Output current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
100%~108%
Using the built-in dimming function on LPF-60D can't turn the lighting fixture totally dark. Please refer to the connection method below to
achieve 0% brightness of the lighting fixture connecting to the LED power supply unit.
Dimming connection diagram for turning the lighting fixture ON/OFF :
N
L
Switch
Relay
Adjuster
0~100K Ohms resistance
1~10V DC Voltage
10V PWM Signal
Brown
Blue
AC/L
LPF-60D
AC/N
DIM+
DIMV(-)
V(+)
Blue
White
Black
Red
LED Lighting Fixture
Using a switch and relay can turn ON/OFF the lighting fixture.
1.Output constant current level can be adjusted through output cable by connecting a resistor or 1~10Vdc or 10V PWM signal between DIM+ and DIM-.
2.The LED lighting fixture can be turned ON/OFF by the switch.
File Name:LPF-60D-SPEC 2012-03-20