HLP-40H 40W Single Output Switching Power Supply series ■ Features : Universal AC input / Full range (up to 305VAC) Built-in active PFC function Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection Output constant current level adjustable Class 2 power unit Three in one dimming function (1~10Vdc or PWM signal or resistance) Suitable for built in LED lighting system Suitable for dry / damp locations 100% full load burn-in test 3 years warranty M M SPECIFICATION 12V DC VOLTAGE CONSTANT CURRENT REGION Note.4 7.2 ~12V 15V 20V 24V 30V 36V 42V 48V 54V 9 ~ 15V 12 ~ 20V 14.4 ~ 24V 21.6 ~ 36V 25.2 ~ 42V 28.8 ~ 48V 32.4 ~ 54V 1.12A 0.96A 0.84A 0.75A RATED CURRENT 3.33A 2.67A 2A 1.67A RATED POWER 40W 40W 40W 40.1W 40.2W 40.3W 40.3W 40.3W 40.5W 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 300mVp-p 300mVp-p 300mVp-p 17 ~ 22V 22 ~ 27V 27 ~ 33V 33 ~ 40V 40 ~ 46V 44 ~ 53V 49 ~ 58V 10.8 ~ 13.5V 13.5 ~ 17V VOLTAGE ADJ. RANGE Can be adjusted by internal potentiometer CURRENT ADJ. RANGE 1.6 ~ 2.67A 1.2 ~ 2A 1 ~ 1.67A 0.8 ~ 1.34A VOLTAGE TOLERANCE Note.3 ±2.5% ±2.0% ±1.0% ±1.0% ±1.0% 0.67 ~ 1.12A 0.58 ~ 0.96A 0.5 ~ 0.84A ±1.0% ±1.0% ±1.0% LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% LOAD REGULATION ±2.0% ±1.5% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% SETUP, RISE TIME 2 ~ 3.33A Note.6 500ms, 80ms at full load 16ms/230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE Note.5 90 ~ 305VAC 0.45 ~ 0.75A ±1.0% 230VAC / 115VAC 16ms/115VAC at full load 127 ~ 431VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve) TOTAL HARMONIC DISTORTION EFFICIENCY (Typ.) THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input 87% 88% 88.5% 89% 89.5% 87% 89% 88% AC CURRENT (Typ.) INRUSH CURRENT(Typ.) 0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC COLD START 50A(twidth=210μs measured at 50% Ipeak) at 230VAC MAX. No. of PSUs on 16A CIRCUIT BREAKER 12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC OVER CURRENT Note.4 SHORT CIRCUIT OVER VOLTAGE 95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed 41 ~ 49V 15 ~ 21V 18 ~ 24V 23 ~ 30V 35 ~ 43V 48 ~ 58V 28 ~ 35V Shut down o/p voltage, re-power on to recover WORKING TEMP. -40 ~ +70℃ (Refer to "Derating Curve") WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS 59 ~ 68V 20 ~ 95% RH non-condensing -40 ~ +80℃, 10 ~ 95% RH ±0.03%/℃ (0 ~ 50℃) 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN61347-1, EN61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1, EN60335-1 SAFETY & WITHSTAND VOLTAGE I/P-O/P:3.75KVAC EMC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55015, EN61000-3-2 Class C (≧60% load) ; EN61000-3-3 ISOLATION RESISTANCE 54 ~ 65V Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE EMC EMISSION 89.5% <0.75mA / 277VAC LEAKAGE CURRENT PROTECTION ( except for 48V,54V ) 18 ~ 30V 1.34A RIPPLE & NOISE (max.) Note.2 150mVp-p INPUT ( for 48V,54V only) HLP-40H-12 HLP-40H-15 HLP-40H-20 HLP-40H-24 HLP-40H-30 HLP-40H-36 HLP-40H-42 HLP-40H-48 HLP-40H-54 MODEL OUTPUT SELV I/P-FG:2KVAC O/P-FG:0.5KVAC Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A 287.9Khrs min. MIL-HDBK-217F (25℃) 147*53*27mm (L*W*H) DIMENSION 0.2Kg;72pcs/15.4Kg/1.09CUFT PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. EMC IMMUNITY MTBF OTHERS NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Please refer to "DRIVING METHODS OF LED MODULE". 5. Derating may be needed under low input voltages. Please check the static characteristics for more details. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers. 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains. File Name:HLP-40H-SPEC 2015-05-28 HLP-40H 40W Single Output Switching Power Supply Mechanical Specification series Unit:mm 147 3.5 53 43 5 140 CN2 6 5 4 3 2 1 FS1 T3.15A/300V SVR2 Io ADJ Vo ADJ 3max. 27max. CN1 SVR1 6 5 4 3 2 1 AC Input Connector (CN1) : JST B6P-VH or equivalent Pin No. 1 2,4,5 3 6 Assignment AC/L No Pin AC/N FG DC Output Connector (CN2) : JST B6P-VH or equivalent Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Pin No. 1 2 3,4 5,6 Assignment DIM+ DIM-V +V Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent : Grounding required Block Diagram fosc : 100KHz EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT +V -V DIM+ DIM- O.L.P. O.T.P. FG O.L.P. DETECTION CIRCUIT PWM & PFC CONTROL O.V.P. Derating Curve Static Characteristics 100 100 90 80 80 230VAC Input only 70 50 LOAD (%) LOAD (%) 60 40 20 -40 -25 -10 0 15 30 50 AMBIENT TEMPERATURE (℃) 60 70 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 305 INPUT VOLTAGE (V) 60Hz File Name:HLP-40H-SPEC 2015-05-28 40W Single Output Switching Power Supply HLP-40H series Power Factor Characteristic Constant Current Mode 1 0 .9 9 0 .9 8 0 .9 7 0 .9 6 0 .9 5 PF 0 .9 4 0 .9 3 277VAC 0 .9 2 230VAC 0 .9 1 115VAC 0 .9 0 .8 9 0 .8 8 0 .8 7 0 .8 6 0 .8 5 50% 60% 70% 80% 90% 100% (40W) LOAD EFFICIENCY vs LOAD (48V Model) HLP-40H series possess superior working efficiency that up to 89.5% can be reached in field applications. 92 EFFICIENCY (%) 90 88 86 84 82 277VAC 80 230VAC 78 115VAC 76 74 72 70 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD DRIVING METHODS OF LED MODULE This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs. In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. 100 Should there be any compatibility issues, please contact MEAN WELL. Vo(%) Constant Current area 60 (min.) Hiccup Protection 50 100 Io (%) Typical LED power supply I-V curve File Name:HLP-40H-SPEC 2015-05-28 HLP-40H 40W Single Output Switching Power Supply series DIMMING OPERATION FG +V +V -V -V DIMDIM+ AC/N AC/L ※ Output constant current level can be adjusted through output connector by 1~10VDC, PWM signal, or connecting a resistance between DIM+ and DIM-. ※ Please DO NOT connect "DIM-" to "-V". ※ Reference resistance value for output current adjustment (Typical) Single driver 10KΩ 20KΩ 30KΩ 40KΩ 50KΩ 60KΩ 70KΩ 80KΩ 90KΩ 100KΩ Resistance Multiple drivers value (N=driver quantity for synchronized 10KΩ/N 20KΩ/N 30KΩ/N 40KΩ/N 50KΩ/N 60KΩ/N 70KΩ/N 80KΩ/N 90KΩ/N 100KΩ/N dimming operation) Percentage of rated current 10% 20% 30% 40% OPEN ----- 50% 60% 70% 80% 90% 100% 95%~108% ※ 1 ~ 10V dimming function for output current adjustment (Typical) Dimming value 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V OPEN Percentage of rated current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%~108% ※ 10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz Duty value 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% OPEN Percentage of rated current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%~108% ※Using the built-in dimming function can't turn the lighting fixture totally dark. Please refer to the connection method below to achieve 0% brightness of the lighting fixture connecting to the LED power supply unit. Dimming connection diagram for turning the lighting fixture ON/OFF : N FG L Switch Relay Adjuster 10~100K Ohms resistance 1~10V DC Voltage 10V PWM Signal Green/ Yellow Brown Blue AC/L AC/N HLP-40H DIM+ DIMV(-) V(+) Blue White Black Red LED Lighting Fixture Using a switch and relay can turn ON/OFF the lighting fixture. 1.Output constant current level can be adjusted through output connector by connecting a resistance or 1~10Vdc or 10V PWM signal between DIM+ and DIM-. 2.The LED lighting fixture can be turned ON/OFF by the switch. File Name:HLP-40H-SPEC 2015-05-28