MA-COM MADCSM0001

Dual-Band/Triple-Mode Downconverter
869 - 893 MHz and 1930 - 1990 MHz
Functional Block Diagram
Features
MODE SEL
MODE SEL VDD
CELL SRC
CELL VDD
Highly Integrated Downconverter
Operates over 2.8 V to 5 V Supply Voltage
Dual-Band and Triple-Mode Operation
High Linearity, IP3 = 10 dBm typical
Adjustable Gain and IP3
4 mm 20-Lead PQFN Plastic Package
CELL IFA IN
•
•
•
•
•
•
MADCSM0001
V2
1
CELL MIX
CELL IF OUT1
GND
Description
CELL IF OUT2
PCS IFA IN
GND
PCS IF OUT
PCS MIX
PCS SRC
CELL LO IN
GND
PCS VDD
GND
PCS LO IN
M/A-COM’s MADCSM0001 is a downconverter
suitable for Dual-Band and Triple-Mode Operation.
The MADCSM0001 has a 50-ohm matched input,
consumes low DC power and incorporates an
on-chip switch that determines CDMA and AMPS
mode select. The designer can tailor the linearity
and gain performance of the MADCSM0001
according to the system needs.
GND
Pin Configuration
The MADCSM0001 is ideally suited for wireless
applications where low noise, low current and high
linearity are important features.
Pin No.
Function
Description
1
CELL MIX
Cellular Mixer RF Input/ Mixer IF Output
2
GND
DC and RF Ground
The MADCSM0001 is fabricated using M/A-COM’s
0.5-micron low noise E/D GaAs MESFET process.
The process features full passivation for increased
performance and reliability.
3
PCS IFA IN
PCS IFA Input
4
GND
DC and RF Ground
5
PCS MIX
PCS Mixer RF Input/Mixer IF Output
6
PCS LO IN
PCS LO Buffer Input (-10 to -5 dBm)
7
GND
DC and RF Ground
8
PCS VDD
PCS Downconverter Supply Voltage. Must
be RF bypassed
Ordering Information
1
Part Number
Package
9
GND
DC and RF Ground
MADCSM0001
Bulk Packaging
10
CELL LO IN
Cellular LO Buffer Input (-10 to -5 dBm)
MADCSM0001TR
1000 piece reel
11
PCS SRC
Parallel RC network determines the PCS
IFA Current, Gain and IIP3.
MADCSM0001SMB
Sample Board
12
PCS IF OUT
PCS IF Out. VDD and IF matching
required.
13
GND
DC and RF Ground
14
CELL IF
OUT2
Cellular IF Out2. VDD and IF matching
required.
15
CELL IF
OUT1
Cellular IF Out1. VDD and IF matching
required.
16
MODE SEL
Selects between Cellular IF Out1 and
IF Out2
17
MODE SEL
VDD
Mode Select Network Supply Voltage
18
CELL SRC
Parallel RC network determines the
Cellular IFA Current, Gain and IIP3.
19
CELL VDD
Cellular Downconverter Supply
Voltage. Must be RF bypassed.
20
CELL IFA IN
Cellular IFA Input
1. Reference Application Note M513 for reel size information.
Absolute Maximum Ratings
Parameter
2,3
Absolute Maximum
Voltage
6V
Input Power
0 dBm
Operating Temperature
-30°C to +85°C
Storage Temperature
-65°C to +150°C
2. Exceeding any one or combination of these limits may cause
permanent damage to this device.
3. M/A-COM does not recommend sustained operation near
these survivability limits.
1
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
Dual-Band/Triple-Mode Downconverter
869 - 893 MHz and 1930 - 1990 MHz
MADCSM0001
V2
Cellular Band - Electrical Specifications:
TA = 25°C, Z0 = 50 Ω, VDD = 3.0 V, MODE_SEL = 0 V / 3.0 V
RF Frequency = 880 MHz, LO Frequency = 965 MHz, IF Frequency = 85 MHz
Parameter
Test Conditions
Units
Min.
Typ.
Max.
LO Power
—
dBm
-10
-8
-5
Conversion Gain
LO = -8 dBm
dB
5
10
12
Noise Figure
LO = -8 dBm
dB
—
8
—
Input IP3
LO = -8 dBm
dBm
5
10
—
Return Loss
RF Port
LO Port
IF Port
dB
dB
dB
—
—
—
12
25
17
—
—
—
Isolation
LO to IF
RF to IF
dB
dB
—
—
13
28
—
—
Current
LO = -8 dBm
mA
—
10
15
Typ.
Max.
PCS Band - Electrical Specifications:
TA = 25°C, Z0 = 50 Ω, VDD = 3.0 V
RF Frequency = 1960 MHz, LO Frequency = 1750 MHz, IF Frequency = 210 MHz
Parameter
Test Conditions
Units
Min.
LO Power
—
dBm
-10
-8
-5
Conversion Gain
LO = -8 dBm
dB
9.5
12
14.5
Noise Figure
LO = -8 dBm
dB
—
8
—
Input IP3
LO = -8 dBm
dBm
4
10
—
Return Loss
RF Port
LO Port
IF Port
dB
—
—
—
12
15
19
—
—
—
Isolation
LO to IF
RF to IF
dB
dB
—
—
39
59
—
—
Current
LO = -8 dBm
mA
—
13
17
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive to
electrostatic discharge (ESD) and can be damaged by
static electricity. Proper ESD control techniques should
be used when handling these devices.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
Dual-Band/Triple-Mode Downconverter
869 - 893 MHz and 1930 - 1990 MHz
Sample Board Schematic
MADCSM0001
V2
Recommended PCB Configuration
C17
R2 C16
C15
L11
L2
L1
C1
C13
C2
L9
L8
C3
L4
C7
C4
C10
L7
L5
C5
C12
C9
C11
R1
L6
L3
C14
L10
C8
C6
External Circuitry Parts List
Ref
Designation
Value
Case
Size
Purpose
C1
2.7 pF
0402
RF Matching
C2,C3
1000 pF
0402
RF/IF Bypass
C4
1 pF
0402
RF Matching
C5
2 pF
0402
RF Matching
C6,C7,C8,C12,
C14,C15,C16,C17
0.1 µF
0402
RF/IF Bypass
C9
39 pF
0402
IF Matching
C10
12 pF
0402
IF Matching
C11,C13
33 pF
0402
IF Matching
L1,L11
22 nH
0603
RF Matching
L2
270 nH
0603
IF Matching
L3
6.8 nH
0603
RF Matching
L4
120 nH
0603
IF Matching
L5,L6
5.1 nH
0603
RF/IF Matching
L7
15 nH
0603
RF Matching
L8
33 nH
0603
IF Choke
L9,L10
150 nH
0603
IF Choke
R1
56 Ohms
0402
PCS Source
Bias
R2
51 Ohms
0402
Cellular Source
Bias
3
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
Dual-Band/Triple-Mode Downconverter
869 - 893 MHz and 1930 - 1990 MHz
MADCSM0001
V2
Typical Performance Curves - Cellular Frequency Band, LO = -8 dBm, VDD= 3.0 V
Conversion Gain (IF1)
Conversion Gain (IF2)
12
12
+25°C
-30°C
+85°C
+25°C
-30°C
+85°C
11
11
10
10
9
9
8
865
870
875
880
885
890
895
900
8
865
870
875
Frequency (MHz)
Input IP3 (IF1)
890
895
900
895
900
895
900
14
+25°C
-30°C
+85°C
13
12
11
11
10
10
9
9
870
+25°C
-30°C
+85°C
13
12
875
880
885
890
895
900
8
865
870
875
Frequency (MHz)
880
885
890
Frequency (MHz)
Noise Figure (IF2)
Noise Figure (IF1)
10
10
+25°C
-30°C
+85°C
+25°C
-30°C
+85°C
9
9
8
8
7
7
6
865
885
Input IP3 (IF2)
14
8
865
880
Frequency (MHz)
870
875
880
885
890
895
900
Frequency (MHz)
4
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
6
865
870
875
880
885
890
Frequency (MHz)
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
Dual-Band/Triple-Mode Downconverter
869 - 893 MHz and 1930 - 1990 MHz
MADCSM0001
V2
Typical Performance Curves - Cellular Frequency Band, LO = -8 dBm, VDD= 3.0 V
LO to IF2 Isolation
LO to IF1 Isolation
15
15
14
14
13
13
12
12
+25°C
+25°C
-30°C
-30°C
+85°C
11
950
955
960
965
970
975
980
+85°C
985
11
950
955
Frequency (MHz)
960
965
970
975
31
31
30
30
29
29
28
28
27
27
+25°C
+25°C
26
26
-30°C
-30°C
+85°C
+85°C
870
875
880
885
890
895
900
25
865
870
875
880
885
890
Current (IF1)
900
Current (IF2)
12
12
11
11
10
10
9
9
+25°C
-30°C
+85°C
+25°C
-30°C
+85°C
870
895
Frequency (MHz)
Frequency (MHz)
8
865
985
RF to IF2 Isolation
RF to IF1 Isolation
25
865
980
Frequency (MHz)
875
880
885
890
895
900
Frequency (MHz)
5
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
8
865
870
875
880
885
890
895
900
Frequency (MHz)
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
Dual-Band/Triple-Mode Downconverter
869 - 893 MHz and 1930 - 1990 MHz
MADCSM0001
V2
Typical Performance Curves - Cellular Frequency Band, LO = -8 dBm, VDD= 3.0 V
RF Port Match
LO Port Match
0
5
+25°C
-5
+25°C
0
-30°C
-30°C
-5
+85°C
-10
+85°C
-10
-15
-15
-20
-20
-25
-25
-30
-30
-35
-35
929
954
979
1004
844
869
894
919
Frequency (MHz)
Frequency (MHz)
IF1 Port Match
IF2 Port Match
0
0
+25°C
-5
-10
+25°C
-5
-30°C
+85°C
-30°C
+85°C
-10
-15
-15
-20
-20
-25
-25
-30
-30
-35
70
75
80
85
90
95
100
Frequency (MHz)
6
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
-35
70
75
80
85
90
95
100
Frequency (MHz)
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
Dual-Band/Triple-Mode Downconverter
869 - 893 MHz and 1930 - 1990 MHz
MADCSM0001
V2
Typical Performance Curves - PCS Frequency Band, LO = -8 dBm, VDD = 3.0 V
Conversion Gain
Input IP3
12
15
+25°C
-30°C
+85°C
+25°C
-30°C
+85°C
14
11
13
10
12
9
11
1930
1940
1950
1960
1970
1980
1990
8
1930
1940
1950
1960
1970
1980
1990
Frequency (MHz)
Frequency (MHz)
LO to IF Isolation
Noise Figure
9
41
40
8
39
38
7
6
1930
1940
+25°C
37
+25°C
-30°C
+85°C
-30°C
+85°C
1950
1960
1970
1980
1990
36
1720
1730
Frequency (MHz)
1750
1760
1770
1780
1980
1990
Frequency (MHz)
RF to IF Isolation
Current
15
61
+25°C
-30°C
+85°C
+25°C
60
1740
-30°C
14
+85°C
59
13
58
12
57
56
1930
1940
1950
1960
1970
1980
1990
Frequency (MHz)
7
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
11
1930
1940
1950
1960
1970
Frequency (MHz)
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
Dual-Band/Triple-Mode Downconverter
869 - 893 MHz and 1930 - 1990 MHz
MADCSM0001
V2
Typical Performance Curves - PCS Frequency Band, LO = -8 dBm, VDD = 3.0 V
LO Port Match
RF Port Match
0
0
+25°C
-5
-5
-30°C
+85°C
-10
-10
-15
-15
-20
-20
-25
-25
-30
-30
-35
-35
+25°C
-30°C
1660
1720
1780
1840
Frequency (MHz)
1870
+85°C
1930
1990
2050
Frequency (MHz)
IF Port Match
5
0
+25°C
-5
-30°C
+85°C
-10
-15
-20
-25
-30
-35
180
190
200
210
220
230
240
Frequency (MHz)
4 mm 20-Lead PQFN†
†
Meets JEDEC moisture sensitivity level 1 requirements.
8
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.