POWERBOX MI-A66-MU

MEDICAL & MILITARY
MI-IAM Series
2 0 0 W AT T S M I L I TA R Y C O T S I N P U T AT T E N U AT O R M O D U L E S
Features
•
•
•
•
•
•
•
Military Specification Compliance
MIL-STD-461C & D: EMI/RFI
MIL-STD704A: Transients and Spikes
MIL-STD-1275A: Transients and Spikes
MIL-STD-810: Environments
MIL-I-45208: Quality System
Expansion port for additional power
Specifications
STANDARDS AND APPROVALS
INPUT
Environmental (MIL-STD-810D)
Nominal input
28Vdc
270Vdc
Input range
18.8 – 50Vdc
125V – 400Vdc
Input spike limit
(MIL-STD-704A)
(MIL-STD-1275A/B)
-600V to 600Vdc
-250V to 205Vdc
800Vdc max
-600V to 600Vdc
Vibration – Method 514.3
20 g’s
Input surge limit
100Vdc
500Vdc
Shock – Method 516.3
40 g’s
Overvoltage shutdown
50Vdc
400Vdc
Reliability (MIL-HDBK-217F)
Recommended fuse
20A
4A F03A type
25°C Ground benign
4,719,000 hours
Inrush Current
110 %
110% of input typical
50°C Naval sheltered
849,000 hours
Yes
Yes
65°C Airborne inhabited cargo 665,000 hours
Reverse polarity protection
70,000 ft
Humidity - Method 507.2
86/240 (%/hours)
Acceleration – Method 513.3 9 g’s
EMI/RFI characteristics (MIL-STD-461C & D)
OUTPUT
28Vdc
270Vdc
Output Power
250W
250W
Clamp Voltage
60Vdc
420Vdc
Overload protection
20A
4A
OPERATING
Efficiency
95% – 97%
Isolation Characteristics
Input to Base 1,500Vrms
Output to Base 1,500Vrms
Input power leads
Conduct emissions
CE01, CE03, CE07 MIL-STD-461 C
CE101, CE102 MIL-STD-461 D&E
Conducted susceptibility
CS01, CS02, CS06 MIL-STD-461 C
CS101, CS114, CS115, CS116 MIL-STD-461 D&E
MECHANICAL
Weight
85 grams
Dimensions
57.9 x 61 x 12.7mm
Selection Table
MECHANICAL
Product grade
IGrade
M Grade
Storage temperature
-55°C to +125°C
-65°C to +125°C
MODEL
NOMINAL INPUT INPUT COMPATIBLE
CONVERTER
NUMBER
VOLTAGE
RANGE MI-SERIES
Operating temperature
(baseplate)
-40°C to +100°C
-55°C to +100°C
MI-A22-MU
28Vdc
18.8-50V MI-22x and MI-J2x
M Grade
MI-A66-MU
270Vdc
125-400V MI-26x and MI-J6x
M Grade
Power cycling burn-in
12hrs 25 cycles
96hrs 200 cycles
MI-A22-IU
28Vdc
18.8-50V MI-22x and MI-J2x
I Grade
Temperature cycled
48 hrs, 12-16cycles
48hrs, 12-16 cycles
MI-A66-IU
270Vdc
125-400V MI-26x and MI-J6x
I Grade
With power off
-55°C to +100°C
-65°C to +100°C
Test data supplied at these -40°C to +80°C
temperature
Derating
378
Altitude – Method 500.2
NAVMAT P-4855-1A
-55°C to +80°C