ALLEN-BRADLEY MSR6R

Safety Relays
Monitoring Safety Relays
Minotaur MSR6R/T
Specifications
Standards
EN 954-1, ISO13849-1, IEC/EN
60204-1, IEC 60947-5-1, ANSI
B11.19, AS4024.1
Category
Cat. 3 per EN 954-1 (ISO 13849-1)
Approvals
C-Tick, CE marked for all
applicable directives, cULus & TUV
Power Supply
24V AC/DC, 110V or 230V AC 50/
60Hz
Power Consumption
<4VA
Safety Inputs
2 N.C.
Input Simultaneity
0.5 seconds
Maximum Input Resistance
500 Ω
Reset
Monitored Man. or Auto./Man.
Description
Outputs
3 N.O. Safety; 1 N.C. Auxiliary
The MSR6R/T has an internal switch that allows the user to select
either 1 N.C. single channel input for use with gate interlock and
emergency stop buttons in lower risk applications or 2 N.C. dual
channel inputs for higher risk applications.
➊ Output Utilization per IEC
60947-5-1 (Inductive)
B300 AC-15; 4A/250V AC,
4A/120V AC
P300 DC-13; 3A/24V DC
Thermal Current (non switching)
4A
Fuses Input (internal, replace.)
Output (external)
500mA time lag
5A quick acting
Min. Switched Current/Voltage
10mA/10V
Maximum Dropout Time
50ms
Indication LEDs
Red = Power On; Green = K1
Closed; Green = K2 Closed;
Amber = Single Channel Mode
The MSR6R/T has an internal selector switch that can
accommodate automatic/manual or a monitored manual reset
function. Automatic/manual reset can use a jumper or can be used
to check operation of the contacts. Monitored manual requires the
use of a manually operated normally open momentary switch to
activate the outputs.
The MSR6R/T has 3 N.O. safety outputs and 1 N.C. auxiliary
output. The safety outputs have independent and redundant internal
contacts to help ensure the safety function. The auxiliary contact is a
nonsafety output intended to provide an external signal about the
status of the safety outputs.
Features
•
•
•
•
•
•
•
Category 3 per EN 954-1
Stop category 0
Switch selectable input
3 N.O. safety outputs
1 N.C. auxiliary output
Switch selectable reset
45mm wide housing
4-12
2500V
Installation Group
C in accordance with VDE 0110
Pollution Degree
3
Operating Temperature
-10°C to +55°C (+14°F to +131°F)
Humidity
90% RH
Enclosure Protection
IP40, (NEMA 1), DIN 0470
Terminal Protection
IP20, DIN 0470
Conductor Size
1 x 2.5mm2 (14AWG) stranded,
1 x 4mm2 (12AWG) solid
Torque Settings—term. screws
1N⋅m (8.85lb⋅in)
Case Material
Red Polycarbonate
Mounting
35mm DIN rail
Weight
510g (1.12lbs)
Electrical Life
220V AC/4A/880VA cosϕ=0.35
220V AC/1.7A/375VA cosϕ=0.6
30V DC/2A/60W
10V DC/0.01A/0.1W
100,000 operations
500,000 operations
1,000,000 operations
2,000,000 operations
Mechanical Life
2,000,000 operations
Vibration
0.75mm (0.30in) peak, 10-55Hz
Shock
30g, 11ms half sine
➊ See Output Ratings on page 1-29 for details. Consult factory for ratings not
shown.
Application Details
MSR6R/T
Impulse Withstand Voltage
Contactor monitoring circuit
Contactor switching circuit
Supply inclusive of switching circuit
Contactor
Monitored by Minotaur
Use a slotted screwdriver to pop open cover to reveal switches & fuse.
R&T Reset Selector Switch
D
R = Monitored manual reset
Input Switch
facility with system check for
high integrity utilizing a
Replacement S
Fuse
momentary push button.
The push and release feature
R
means the button can not be
Reset Switch
T
held in.
D & S Input Selector Switch
T = Automatic system
D = Dual channel input.
check.
S = Single channel input.
Safety Relays
Monitoring Safety Relays
Minotaur MSR6R/T
Product Selection
Inputs
Safety Outputs
Auxiliary Outputs
1 N.C or 2 N.C.
3 N.O.
1 N.C.
Power Supply
Catalogue Number
24V AC/DC
440R-C23017
110V AC
440R-C23018
230V AC
440R-C23019
Accessories
Description
Page Number
Catalogue Number
500mA Fuse
14-6
440R-A31562
Dimensions—mm (inches) Block Diagram
45.5 (1.79)
120 (4.72)
A1
A2
X1 X2
S24
13 23 33
S23
41
T
R
73 (2.87)
K3
K2
24VDC K2
~
K3
K1
K2
K1
K1
K3
K4
K4
K1
K5
K1
D
K5 K6
S
K6
K2
K2
35mm DIN Rail Mounting
S14
14 24
S13
34 42
Typical Wiring Diagrams
L1
24V DC
Reset
L1 L2 L3
S23 S24
open
S
A1
13
23
33
41 X1
S13
open
S
MSR6R/T
R
closed
L1 L2 L3
S23 S24
K1
S14
A2
14
24
34
13
23
33
41 X1
MSR6R/T
K1
T
closed
42 X2
S13
S14
A2
M
Aux
K1
A1
14
24
34
M
Aux
K1
N
42 X2
Ground
Single-Channel Safety Gate, Monitored Manual Reset,
Single-Channel Output, Monitored Output
Single-Channel Safety Gate, Automatic Reset,
Single-Channel Output, No Monitored Output
L1
24V DC
Reset
L1 L2 L3
L1 L2 L3
S23 S24
open
A1
13
23
33
41 X1
D
S23 S24
open
closed
S13
K1
Ground
K2
S14
A2
14
24
K1
K2
34
Dual-Channel Safety Gate, Monitored Manual Reset,
Dual-Channel Output, Monitored Output
33
41 X1
K1
K2
T
closed
42 X2
Aux
23
D
MSR6R/T
MSR6R/T
R
A1
13
S13
M
S14
A2
14
24
K1
K2
34
42 X2
Aux
M
N
Dual-Channel Safety Gate, Automatic Reset,
Dual-Channel Output, Monitored Output
4-13