64Mb: 4 Meg x 16 Mobile SDRAM Features Mobile SDRAM MT48H4M16LF – 1 Meg x 16 x 4 banks Features Figure 1: • 1.70–1.95V • Fully synchronous; all signals registered on positive edge of system clock • Internal pipelined operation; column address can be changed every clock cycle • Internal banks for hiding row access/precharge • Programmable burst lengths: 1, 2, 4, 8, or continuous page1 • Auto precharge, includes concurrent auto precharge • Self refresh mode • 64ms, 4,096-cycle refresh • LVTTL-compatible inputs and outputs • Partial-array self refresh (PASR) power-saving mode • On-die temperature-compensated self refresh (TCSR) • Deep power-down (DPD) mode • Programmable output drive strength • Operating temperature ranges – Commercial (0°C to +70°C) – Industrial (–40°C to +85°C) Notes: 1. For continuous page burst, contact factory for availability. 1 2 3 7 8 9 A VSS DQ15 VSSQ VDDQ DQ0 VDD B DQ14 DQ13 VDDQ VSSQ DQ2 DQ1 C DQ12 DQ11 VSSQ VDDQ DQ4 DQ3 D DQ10 DQ9 VDDQ VSSQ DQ6 DQ5 E DQ8 NC VSS VDD LDQM DQ7 F UDQM CLK CKE CAS# RAS# WE# G NC A11 A9 BA0 BA1 CS# H A8 A7 A6 A0 A1 A10 J VSS A5 A4 A3 A2 VDD 4 5 6 Top view (Ball down) Table 1: Options 54-Ball VFBGA Ball Assignment (Top View) Address Table Marking • VDD/VDDQ – 1.8V/1.8V • Configurations – 4 Meg x 16 (1 Meg x 16 x 4 banks) • Plastic “green” package – 54-ball VFBGA, 8mm x 8mm • Timing (cycle time) – 7.5ns @ CL = 3 (133 MHz) – 8ns @ CL = 3 (125 MHz) • Operating temperature – Commercial (0°C to +70°C) – Industrial (–40°C to +85°C) • Die revision designator 4 Meg x 16 H 4M16 B4 -75 -8 Table 2: None IT :H Speed Grade Key Timing Parameters CL = CAS (READ) latency -75 -8 PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_1.fm - Rev. C 10/07 EN 1 Meg x 16 x 4 banks 4K 4K (A0–A11) 4 (BA0, BA1) 256 (A0–A7) Configuration Refresh count Row addressing Bank addressing Column addressing 1 Clock Rate (MHz) Access Time CL = 2 CL = 3 CL = 2 CL = 3 104 83 133 125 8ns 8ns 6ns 6ns Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. Products and specifications discussed herein are subject to change by Micron without notice. 64Mb: 4 Meg x 16 Mobile SDRAM Table of Contents Table of Contents Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Mode Register Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Burst Length (BL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Burst Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 CAS Latency (CL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Write Burst Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Extended Mode Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Temperature–Compensated Self Refresh (TCSR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Partial-Array Self Refresh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Driver Strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 COMMAND INHIBIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 NO OPERATION (NOP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 LOAD MODE REGISTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 ACTIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 READ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 WRITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 PRECHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 BURST TERMINATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Auto Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 AUTO REFRESH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 SELF REFRESH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Deep Power-Down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Bank/Row Activation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 READs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 WRITEs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 PRECHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 Power-Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 Deep Power-Down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Clock Suspend. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Burst Read/Single Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Concurrent Auto Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 READ with Auto Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 WRITE with Auto Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 Electrical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 Timing Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 Package Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64Mb_x16_Mobile SDRAM_Y24LTOC.fm - Rev. C 10/07 EN 2 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM List of Figures List of Figures Figure 1: Figure 2: Figure 3: Figure 4: Figure 5: Figure 6: Figure 7: Figure 8: Figure 9: Figure 10: Figure 11: Figure 12: Figure 13: Figure 14: Figure 15: Figure 16: Figure 17: Figure 18: Figure 19: Figure 20: Figure 21: Figure 22: Figure 23: Figure 24: Figure 25: Figure 26: Figure 27: Figure 28: Figure 29: Figure 30: Figure 31: Figure 32: Figure 33: Figure 34: Figure 35: Figure 36: Figure 37: Figure 38: Figure 39: Figure 40: Figure 41: Figure 42: Figure 43: Figure 44: Figure 45: Figure 46: Figure 47: Figure 48: Figure 49: 54-Ball VFBGA Ball Assignment (Top View) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Part Numbering Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Functional Block Diagram – 4 Meg x 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Mode Register Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 CAS Latency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Extended Mode Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Activating a Specific Row in a Specific Bank Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Meeting tRCD (MIN) when 2 < tRCD (MIN)/tCK < 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 READ Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Consecutive READ Bursts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Random READ Accesses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 READ-to-WRITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 READ-to-WRITE with Extra Clock Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 READ-to-PRECHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Terminating a READ Burst . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 WRITE Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 WRITE Burst . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 WRITE-to-WRITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Random WRITE Cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 WRITE-to-READ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 WRITE-to-PRECHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 Terminating a WRITE Burst . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 PRECHARGE Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 Power-Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Clock Suspend During WRITE Burst . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 Clock Suspend During READ Burst . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 READ with Auto Precharge Interrupted by a READ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 READ with Auto Precharge Interrupted by a WRITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 WRITE with Auto Precharge Interrupted by a READ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 WRITE with Auto Precharge Interrupted by a WRITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 Typical Self Refresh Current vs. Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 Initialize and Load Mode Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 Power-Down Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 Clock Suspend Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 Auto Refresh Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 Self Refresh Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 READ – Without Auto Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 READ – with Auto Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 Single READ – Without Auto Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 Single READ – with Auto Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 Alternating Bank Read Accesses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 READ – DQM Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 WRITE – Without Auto Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 WRITE – with Auto Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57 Single WRITE – Without Auto Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58 Single WRITE – with Auto Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 Alternating Bank Write Accesses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 WRITE – DQM Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 54-Ball VFBGA (8mm x 8mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64Mb_x16_Mobile SDRAM_Y24LLOF.fm - Rev. C 10/07 EN 3 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM List of Tables List of Tables Table 1: Table 2: Table 3: Table 4: Table 5: Table 6: Table 7: Table 8: Table 9: Table 10: Table 11: Table 12: Table 13: Table 14: Table 15: Table 16: Address Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Key Timing Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Ball Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Burst Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Truth Table 1 – Commands and DQM Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Truth Table 2 – CKE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 Truth Table 3 – Current State Bank n, Command to Bank n . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Truth Table 4 – Current State Bank n, Command to Bank m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 DC Electrical Characteristics and Operating Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 AC Electrical Characteristics and Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 Electrical Characteristics and Recommended AC Operating Conditions . . . . . . . . . . . . . . . . . . . . . . .40 AC Functional Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41 IDD Specifications and Conditions (x16) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41 IDD7 - Self Refresh Current Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64Mb_x16_Mobile SDRAM_Y24LLOT.fm - Rev. C 10/07 EN 4 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM General Description Figure 2: Part Numbering Diagram Example Part Number: MT48H4M16LFB4-8 IT :H – MT48 VDD/ VDDQ Configuration Package Temp Speed Revision VDD/VDDQ 1.8V/1.8V :H Design revision H Operating Temp. Configuration 4 Meg x16 4M16LF Package None Commercial IT Industrial Speed Grade 54-ball VFBGA (8mm x 8mm) ”green” B4 -75 7.5ns -8 8ns General Description The Micron® 64Mb SDRAM is a high-speed CMOS, dynamic random access memory containing 67,108,864 bits. It is internally configured as a quad-bank DRAM with a synchronous interface (all signals are registered on the positive edge of the clock signal, CLK). Each of the x16’s 16,777,216-bit banks is organized as 4,096 rows by 256 columns by 16 bits. Read and write accesses to the SDRAM are burst oriented; accesses start at a selected location and continue for a programmed number of locations in a programmed sequence. Accesses begin with the registration of an ACTIVE command, which is then followed by a READ or WRITE command. The address bits registered coincident with the ACTIVE command are used to select the bank and row to be accessed (BA0, BA1 select the bank; A0–A11 select the row). The address bits registered coincident with the READ or WRITE command are used to select the starting column location for the burst access. The SDRAM provides for programmable read or write burst lengths of 1, 2, 4, or 8 locations with a burst terminate option. An auto precharge function may be enabled to provide a self-timed row precharge that is initiated at the end of the burst sequence. The 64Mb SDRAM uses an internal pipelined architecture to achieve high-speed operation. This architecture is compatible with the 2n rule of prefetch architectures, but it also enables the column address to be changed on every clock cycle to achieve a high-speed, fully random access. Precharging one bank while accessing one of the other three banks will hide the PRECHARGE cycles and provide seamless high-speed, random-access operation. The 64Mb SDRAM is designed to operate in 1.8V, low-power memory systems. An auto refresh mode is provided, along with a power-saving, deep power-down mode. All inputs and outputs are LVTTL-compatible. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 5 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM General Description Self refresh mode offers temperature compensation through an on-die temperature sensor and partial-array self refresh (PASR). PASR enables users to achieve additional power savings from normal usage. The temperature sensor is enabled by default and the PASR settings can be programmed through the extended mode register. SDRAM offers substantial advances in DRAM operating performance, including the ability to synchronously burst data at a high data rate with automatic column-address generation, the ability to interleave between internal banks to hide precharge time, and the capability to randomly change column addresses on each clock cycle during a burst access. Figure 3: Functional Block Diagram – 4 Meg x 16 BA1 0 0 1 1 CKE BA0 0 1 0 1 Bank 0 1 2 3 CLK COMMAND DECODE CS# WE# CAS# RAS# CONTROL LOGIC BANK3 BANK2 BANK1 MODE REGISTER REFRESH 12 COUNTER 12 ROWADDRESS MUX 12 12 BANK0 ROWADDRESS LATCH & DECODER 4096 BANK0 MEMORY ARRAY (4,096 x 256 x 16) 2 LDQM, UDQM SENSE AMPLIFIERS 16 4096 14 ADDRESS REGISTER 2 DATA OUTPUT REGISTER I/O GATING DQM MASK LOGIC READ DATA LATCH WRITE DRIVERS 2 A0-A11, BA0, BA1 2 BANK CONTROL LOGIC 16 16 256 (x16) DQ0DQ15 DATA INPUT REGISTER COLUMN DECODER 8 PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN COLUMNADDRESS COUNTER/ LATCH 8 6 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM General Description Table 3: Ball Descriptions 54-Ball VFBGA Symbol Type Description F2 CLK Input F3 CKE Input G9 CS# Input F7, F8, F9 CAS#, RAS#, WE# LDQM, UDQM Input G7, G8 BA0, BA1 Input H7, H8, J8, J7, J3, J2, H3, H2, H1, G3, H9, G2 A0–A11 Input A8, B9, B8, C9, C8, D9, D8, E9, E1, D2, D1, C2, C1, B2, B1, A2 E2, G1 DQ0–DQ15 I/O Clock: CLK is driven by the system clock. All SDRAM input signals are sampled on the positive edge of CLK. CLK also increments the internal burst counter and controls the output registers. Clock enable: CKE activates (HIGH) and deactivates (LOW) the CLK signal. Deactivating the clock provides precharge power-down and SELF REFRESH operation (all banks idle), ACTIVE POWER-DOWN (row active in any bank), deep power-down (all banks idle), or CLOCK SUSPEND operation (burst/access in progress). CKE is synchronous except after the device enters power-down and self refresh modes, where CKE becomes asynchronous until after exiting the same mode. The input buffers, including CLK, are disabled during power-down and self refresh modes, providing low standby power. CKE may be tied HIGH. Chip select: CS# enables (registered LOW) and disables (registered HIGH) the command decoder. All commands are masked when CS# is registered HIGH. CS# provides for external bank selection on systems with multiple banks. CS# is considered part of the command code. Command inputs: CAS#, RAS#, and WE# (along with CS#) define the command being entered. Input/output mask: DQM is sampled HIGH and is an input mask signal for write accesses and an output enable signal for read accesses. Input data is masked during a WRITE cycle. The output buffers are placed in a High-Z state (two-clock latency) during a READ cycle. LDQM corresponds to DQ0– DQ7, UDQM corresponds to DQ8–DQ15. LDQM and UDQM are considered same state when referenced as DQM. DQM loading is designed to match that of DQ balls. Bank address input(s): BA0 and BA1 define to which bank the ACTIVE, READ, WRITE, or PRECHARGE command is being applied. These pins also select between the mode register and the extended mode register. Address inputs: A0–A11 are sampled during the ACTIVE command (rowaddress A0–A11) and READ/WRITE command (column-address A0–A7; with A10 defining auto precharge) to select one location out of the memory array in the respective bank. A10 is sampled during a PRECHARGE command to determine whether all banks are to be precharged (A10 HIGH) or bank selected by BA0, BA1. The address inputs also provide the op-code during a LOAD MODE REGISTER command. Data input/output: Data bus. NC – A7, B3, C7, D3 A3, B7, C3, D7 A9, E7, J9 A1, E3, J1 VDDQ VSSQ VDD VSS Supply Supply Supply Supply E8, F1 PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN Input NC = no connect (internally unconnected): These may be left unconnected, but it is recommended that they be connected to VSS. DNU = do not use; must be left unconnected. DQ power: Provides isolated power to DQ for improved noise immunity. DQ ground: Provides isolated ground to DQ for improved noise immunity. Core power supply. Ground. 7 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Functional Description Functional Description The 64Mb SDRAM (1 Meg x 16 x 4 banks) is a quad-bank DRAM that operates at 1.8V and includes a synchronous interface (all signals are registered on the positive edge of the clock signal, CLK). Each of the x16’s 16,777,216-bit banks is organized as 4,096 rows by 256 columns by 16 bits. Read and write accesses to the SDRAM are burst oriented; accesses start at a selected location and continue for a programmed number of locations in a programmed sequence. Accesses begin with the registration of an ACTIVE command, which is then followed by a READ or WRITE command. The address bits registered coincident with the ACTIVE command are used to select the bank and row to be accessed (BA0 and BA1 select the bank; A0–A11 select the row). The address bits (A0–A7) registered coincident with the READ or WRITE command are used to select the starting column location for the burst access. Prior to normal operation, the SDRAM must be initialized. The following sections provide detailed information covering device initialization, register definition, command descriptions, and device operation. Initialization SDRAM must be powered up and initialized in a predefined manner. Operational procedures other than those specified may result in undefined operation. Power should be applied to VDD and VDDQ simultaneously. After the power is applied to VDD and VDDQ and the clock is stable (stable clock is defined as a signal cycling within timing constraints specified for the clock pin), the SDRAM requires a 100µs delay prior to issuing any command other than a COMMAND INHIBIT or NOP. Starting at some point during this 100µs period and continuing at least through the end of this period, COMMAND INHIBIT or NOP commands should be applied. After the 100µs delay has been satisfied with at least one COMMAND INHIBIT or NOP command having been applied, a PRECHARGE command should be applied. All banks must then be precharged, thereby placing the device in the all-banks-idle state. When in the idle state, two AUTO REFRESH cycles must be performed. After the AUTO REFRESH cycles are complete, the SDRAM is ready for mode register programming. Because the mode register will power up in an unknown state, it should be loaded prior to applying any operational command. Mode Register Definition Two mode registers exist in mobile SDRAM: the mode register and the extended mode register. The mode register is illustrated in Figure 4 on page 9, and the extended mode register is illustrated in Figure 6 on page 12. The mode register defines the specific mode of operation of the SDRAM, including burst length, burst type, CAS latency, operating mode, and write burst mode. The mode register is programmed via the LOAD MODE REGISTER command and will retain the stored information until it is programmed again or the device loses power. Mode register bits M0–M2 specify the burst length, M3 specifies the type of burst (sequential or interleaved), M4–M6 specify the CAS latency, M7 and M8 specify the operating mode, M9 specifies the write burst mode, and M10 and M11 are reserved for future use and should be set to zero. M12 and M13 are set to zero to select the mode register. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 8 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Mode Register Definition The mode register must be loaded when all banks are idle, and the controller must wait t MRD before initiating the subsequent operation. Violating either of these requirements will result in unspecified operation. Figure 4: Mode Register Definition BA1 BA0 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0 Address bus M13 M12 M11 M10 M9 M8 M7 M6 M5 M4 M3 M2 M1 M0 13 0 9 8 7 6 5 4 12 11 10 0 Reserved WB OP Mode CAS Latency 0 Mode register (Mx) Burst Length M13 M12 Mode Register Definintion 0 0 Base mode register 1 0 3 2 1 BT Burst Length M2 M1 M0 Extended mode register M3 = 0 M3 = 1 0 0 0 1 1 0 0 1 2 2 0 1 0 4 4 Write Burst Mode 0 1 1 8 0 Programmed burst length 1 0 0 Reserved 8 Reserved 1 Single location access 1 0 1 Reserved Reserved 1 1 0 Reserved Reserved 1 1 1 Reserved Reserved M9 M8 M7 M6–M0 Operating Mode Normal operation 0 0 Defined – – – All other states reserved M3 M6 M5 M4 CAS Latency 0 0 0 Reserved 0 0 1 Reserved 0 1 0 2 0 1 1 3 1 0 0 Reserved 1 0 1 Reserved 1 1 0 Reserved 1 1 1 Reserved Burst Type 0 Sequential 1 Interleaved Burst Length (BL) Read and write accesses to the SDRAM are burst oriented, with the burst length (BL) being programmable, as shown in Figure 4 on page 9. The BL determines the maximum number of column locations that can be accessed for a given READ or WRITE command. BLs of 1, 2, 4, or 8 locations are available for both the sequential and the interleaved burst types. Reserved states must not be used, as unknown operation or incompatibility with future versions may result. When a READ or WRITE command is issued, a block of columns equal to the BL is effectively selected. All accesses for that burst take place within this block, meaning that the burst will wrap within the block if a boundary is reached. The block is uniquely selected PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 9 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Mode Register Definition by A1–A7 when BL = 2; by A2–A7 when BL = 4; and by A3–A7 when BL = 8. The remaining (least significant) address bit(s) is (are) used to select the starting location within the block. Burst Type Accesses within a given burst may be programmed to be sequential or interleaved; this is referred to as the burst type and is selected via bit M3. The ordering of accesses within a burst is determined by the BL, the burst type, and the starting column address, as shown in Table 4. Table 4: Burst Definition Burst Length Order of Accesses within a Burst Starting Column Address 2 4 8 A1 0 0 1 1 A1 0 0 1 1 0 0 1 1 A2 0 0 0 0 1 1 1 1 A0 0 1 A0 0 1 0 1 A0 0 1 0 1 0 1 0 1 Type = Sequential Type = Interleaved 0-1 1-0 0-1 1-0 0-1-2-3 1-2-3-0 2-3-0-1 3-0-1-2 0-1-2-3 1-0-3-2 2-3-0-1 3-2-1-0 0-1-2-3-4-5-6-7 1-2-3-4-5-6-7-0 2-3-4-5-6-7-0-1 3-4-5-6-7-0-1-2 4-5-6-7-0-1-2-3 5-6-7-0-1-2-3-4 6-7-0-1-2-3-4-5 7-0-1-2-3-4-5-6 0-1-2-3-4-5-6-7 1-0-3-2-5-4-7-6 2-3-0-1-6-7-4-5 3-2-1-0-7-6-5-4 4-5-6-7-0-1-2-3 5-4-7-6-1-0-3-2 6-7-4-5-2-3-0-1 7-6-5-4-3-2-1-0 CAS Latency (CL) The CAS latency (CL) is the delay, in clock cycles, between the registration of a READ command and the availability of the first piece of output data. The latency can be set to two or three clocks. If a READ command is registered at clock edge n, and the latency is m clocks, the data will be available by clock edge n + m. The DQ will start driving as a result of the clock edge one cycle earlier (n + m - 1), and provided that the relevant access times are met, the data will be valid by clock edge n + m. For example, assuming that the clock cycle time is such that all relevant access times are met, if a READ command is registered at T0 and the latency is programmed to two clocks, the DQ will start driving after T1 and the data will be valid by T2, as shown in Figure 5 on page 11. Table 5 on page 14 indicates the operating frequencies at which each CL setting can be used. Reserved states should not be used because unknown operation or incompatibility with future versions may result. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 10 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Mode Register Definition Figure 5: CAS Latency T0 T1 T2 T3 READ NOP NOP CLK Command tLZ tOH DOUT DQ tAC CL = 2 T0 T1 T2 T3 T4 READ NOP NOP NOP CLK Command tLZ tOH DOUT DQ tAC CL = 3 Don’t Care Undefined Operating Mode The normal operating mode is selected by setting M7 and M8 to zero; the other combinations of values for M7 and M8 are reserved for future use. The programmed burst length applies to both read and write bursts. Reserved states must not be used; unknown operation or incompatibility with future versions may result. Write Burst Mode When M9 = 0, the burst length programmed via M0–M2 applies to both READ and WRITE bursts; when M9 = 1, the programmed burst length applies to READ bursts, but write accesses are single-location accesses. Extended Mode Register The extended mode register controls the functions beyond those controlled by the mode register. These additional functions are special features of the mobile device. They include temperature-compensated self refresh (TCSR) control, partial-array self refresh (PASR), and output drive strength. The extended mode register is programmed via the MODE REGISTER SET command with BA = 1 and BA = 0 and retains the stored information until it is programmed again or the device loses power. The extended mode register must be loaded when all banks are idle and no bursts are in progress, and the controller must wait tMRD before initiating any subsequent operation. Violating any of these requirements will result in unspecified operation. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 11 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Mode Register Definition Figure 6: Extended Mode Register BA1 BA0 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0 E13 13 1 E12 E11 E10 E9 E8 E7 E6 E5 E4 E3 E2 E1 E0 12 11 10 0 9 8 7 6 All must be set to “0” E13 E12 Mode Register Definition 0 Base mode register 0 1 Reserved 0 0 Extended mode register 1 1 Reserved 1 E4 0 5 4 3 1 TCSR DS 2 1 PASR 0 Extended mode register (Ex) E3 Maximum Case Temp. 1 1 85°C 0 0 70°C 0 1 45°C 1 0 15°C E6 E5 Driver Strength Notes: Address bus 0 Full strength E2 0 0 E1 0 0 E0 0 1 Self Refresh Coverage Four banks Two banks 0 1 Half strength 1 0 Quarter strength 0 1 0 One bank 1 1 Reserved 0 1 1 1 1 0 0 1 1 0 1 0 Reserved Reserved 1/2 bank2 1/4 bank2 1 1 1 Reserved 1. The on-die temperature sensor is used in place of TCSR. Setting these bits has no effect. 2. 1/2- and 1/4-bank settings will default to one-bank PASR. Temperature–Compensated Self Refresh (TCSR) On this version of the Mobile SDR SDRAM, a temperature sensor is implemented for automatic control of the self refresh oscillator on the device. Therefore, it is recommended not to program or use the TCSR control bits in the extended mode register. Programming of the TCSR bits has no effect on the device. The self refresh oscillator will continue refresh at the factory-programmed optimal rate for the device temperature. Partial-Array Self Refresh For further power savings during SELF REFRESH, the PASR feature enables the controller to select the amount of memory that will be refreshed during SELF REFRESH. The following refresh options are available: • All banks (banks 0, 1, 2, and 3) • Two banks (banks 0 and 1; BA1 = 0) • One bank (bank 0; BA1 = BA0 = 0) WRITE and READ commands occur to any bank selected during standard operation, but only the selected banks in PASR will be refreshed during SELF REFRESH. Data in unused banks, or portions of banks, is lost when PASR is used. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 12 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Mode Register Definition Driver Strength Bits E5 and E6 of the extended mode register can be used to select the driver strength of the DQ outputs. This value should be set according to the application’s requirements. Full-drive strength is suitable to drive higher load systems. Half-drive strength is intended for multi-drop systems with various loads. Quarter-drive strength is intended for lighter loads or point-to-point systems. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 13 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Commands Commands Table 5 provides a quick reference of available commands. This is followed by a written description of each command. Three additional truth tables appear following “Operations” on page 18; these tables provide current state/next state information. Table 5: Truth Table 1 – Commands and DQM Operation Note 1; notes appear below table Name (Function) CS# RAS# CAS# WE# COMMAND INHIBIT (NOP) NO OPERATION (NOP) ACTIVE (Select bank and activate row) READ (Select bank and column, and start READ burst) WRITE (Select bank and column, and start WRITE burst) BURST TERMINATE or deep power-down (Enter deep power-down mode) PRECHARGE (Deactivate row in bank or banks) AUTO REFRESH or SELF REFRESH (Enter self refresh mode) LOAD MODE REGISTER/LOAD EXTENDED MODE REGISTER Write enable/output enable Write inhibit/output High-Z Notes: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN DQM ADDR DQ Notes H L L L L L X H L H H H X H H L L H X H H H L L X X X L/H L/H X X X Bank/Row Bank/Col Bank/Col X X X X X Valid X 3 4 4 9, 10 L L L L H L L H X X Bank, A10 X X X 5 6, 7 L L L L X Op-code X 2 X X X X X X X X L H X X Active High-Z 8 8 CKE is HIGH for all commands shown except SELF REFRESH and deep power-down. A0–A11 define op-code written to mode register. A0–A11 provide row address, and BA0, BA1 determine which bank is made active. A0–A7 provide column address; A10 HIGH enables the auto precharge feature (nonpersistent), while A10 LOW disables the auto precharge feature; BA0, BA1 determine which bank is being read from or written to. A10 LOW: BA0, BA1 determine the bank being precharged. A10 HIGH: All banks precharged and BA0, BA1 are “Don’t Care.” This command is AUTO REFRESH if CKE is HIGH, SELF REFRESH if CKE is LOW. Internal refresh counter controls row addressing; all inputs and I/Os are “Don’t Care” except for CKE. Activates or deactivates the DQ during WRITEs (zero-clock delay) and READs (two-clock delay). LDQM controls DQ0–7, UDQM controls DQ8–15. This command is BURST TERMINATE when CKE is HIGH and deep power-down when CKE is LOW. The purpose of the BURST TERMINATE command is to stop a data burst; thus, the command could coincide with data on the bus. However, the DQ column reads a “Don’t Care” state to illustrate that the BURST TERMINATE command can occur when there is no data present. 14 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Commands COMMAND INHIBIT The COMMAND INHIBIT function prevents new commands from being executed by the SDRAM, regardless of whether the CLK signal is enabled. The SDRAM is effectively deselected. Operations already in progress are not affected. NO OPERATION (NOP) The NO OPERATION (NOP) command is used to perform a NOP to an SDRAM which is selected (CS# is LOW). This prevents unwanted commands from being registered during idle or wait states. Operations already in progress are not affected. LOAD MODE REGISTER The mode register is loaded via inputs A0–A11, BA0, BA1. See the “Mode Register” heading in the Register Definition section. The LOAD MODE REGISTER and LOAD EXTENDED MODE REGISTER commands can only be issued when all banks are idle, and a subsequent executable command cannot be issued until tMRD is met. ACTIVE The ACTIVE command is used to open (or activate) a row in a particular bank for a subsequent access. The value on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0–A11 selects the row. This row remains active (or open) for accesses until a PRECHARGE command is issued to that bank. A PRECHARGE command must be issued before opening a different row in the same bank. READ The READ command is used to initiate a burst read access to an active row. The value on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0–A7 selects the starting column location. The value on input A10 determines whether auto precharge is used. If auto precharge is selected, the row being accessed will be precharged at the end of the read burst; if auto precharge is not selected, the row will remain open for subsequent accesses. Read data appears on the DQ subject to the logic level on the DQM inputs two clocks earlier. If a given DQM signal was registered HIGH, the corresponding DQ will be High-Z two clocks later; if the DQM signal was registered LOW, the DQ will provide valid data. WRITE The WRITE command is used to initiate a burst write access to an active row. The value on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0–A7 selects the starting column location. The value on input A10 determines whether auto precharge is used. If auto precharge is selected, the row being accessed will be precharged at the end of the write burst; if auto precharge is not selected, the row will remain open for subsequent accesses. Input data appearing on the DQ is written to the memory array subject to the DQM input logic level appearing coincident with the data. If a given DQM signal is registered LOW, the corresponding data will be written to memory; if the DQM signal is registered HIGH, the corresponding data inputs will be ignored, and a write will not be executed to that byte/column location. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 15 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Commands PRECHARGE The PRECHARGE command is used to deactivate the open row in a particular bank or the open row in all banks. The bank(s) will be available for a subsequent row access a specified time (tRP) after the PRECHARGE command is issued. Input A10 determines whether one or all banks are to be precharged, and in the case where only one bank is to be precharged, inputs BA0, BA1 select the bank. Otherwise BA0, BA1 are treated as “Don’t Care.” After a bank has been precharged, it is in the idle state and must be activated prior to any READ or WRITE commands being issued to that bank. BURST TERMINATE The BURST TERMINATE command is used to truncate fixed-length bursts. The most recently registered READ or WRITE command prior to the BURST TERMINATE command will be truncated, as shown in “Operations” on page 18. Auto Precharge Auto precharge is a feature that performs the same individual-bank PRECHARGE function described above, without requiring an explicit command. This is accomplished by using A10 to enable auto precharge in conjunction with a specific READ or WRITE command. A precharge of the bank/row that is addressed with the READ or WRITE command is automatically performed upon completion of the READ or WRITE burst. Auto precharge is nonpersistent in that it is either enabled or disabled for each individual READ or WRITE command. Auto precharge ensures that the precharge is initiated at the earliest valid stage within a burst. The user must not issue another command to the same bank until the precharge time (tRP) is completed. This is determined as if an explicit PRECHARGE command was issued at the earliest possible time, as described for each burst type in “Operations” on page 18. AUTO REFRESH AUTO REFRESH is used during normal operation of the SDRAM and is analogous to CAS#-BEFORE-RAS# (CBR) refresh in conventional DRAM. This command is nonpersistent, so it must be issued each time a refresh is required. All active banks must be PRECHARGED prior to issuing an AUTO REFRESH command. The AUTO REFRESH command should not be issued until the minimum tRP has been met after the PRECHARGE command, as shown in “Operations” on page 18. The addressing is generated by the internal refresh controller. This makes the address bits “Don’t Care” during an AUTO REFRESH command. The 64Mb SDRAM requires 4,096 AUTO REFRESH cycles every 64ms (tREF). Providing a distributed AUTO REFRESH command every 15.625µs will meet the refresh requirement and ensure that each row is refreshed. Alternatively, 4,096 AUTO REFRESH commands can be issued in a burst at the minimum cycle rate (tRFC), once every 64ms. SELF REFRESH The SELF REFRESH command can be used to retain data in the SDRAM, even if the rest of the system is powered down, as long as power is not completely removed from the SDRAM. When in the self refresh mode, the SDRAM retains data without external clocking. The SELF REFRESH command is initiated like an AUTO REFRESH command PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 16 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Commands except CKE is disabled (LOW). When the SELF REFRESH command is registered, all the inputs to the SDRAM become “Don’t Care” with the exception of CKE, which must remain LOW. During self refresh, the device is refreshed as identified in the extended mode register PASR settings. After self refresh mode is engaged, the SDRAM provides its own internal clocking, causing it to perform its own AUTO REFRESH cycles. The SDRAM must remain in self refresh mode for a minimum period equal to tRAS and may remain in self refresh mode for an indefinite period beyond that. The procedure for exiting self refresh requires a sequence of commands. First, CLK must be stable (stable clock is defined as a signal cycling within timing constraints specified for the clock pin) prior to CKE going back HIGH. When CKE is HIGH, the SDRAM must have NOP commands issued (a minimum of two clocks) for tXSR because time is required for the completion of any internal refresh in progress. Upon exiting the self refresh mode, AUTO REFRESH commands should be issued at once and then every 15.625µs or less, because SELF REFRESH and AUTO REFRESH use the row refresh counter. Deep Power-Down Deep power-down is an operating mode used to achieve maximum power reduction by eliminating the power to the memory array. Data is not retained after the device enters deep power-down mode. This mode is entered by having all banks idle then CS# and WE# held LOW with RAS# and CAS# held HIGH at the rising edge of the clock, while CKE is LOW. This mode is exited by asserting CKE HIGH. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 17 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations Operations Bank/Row Activation Before any READ or WRITE commands can be issued to a bank within the SDRAM, a row in that bank must be “opened.” This is accomplished via the ACTIVE command, which selects both the bank and the row to be activated (see Figure 7). After opening a row (issuing an ACTIVE command), a READ or WRITE command may be issued to that row, subject to the tRCD specification. tRCD (MIN) should be divided by the clock period and rounded up to the next whole number to determine the earliest clock edge after the ACTIVE command on which a READ or WRITE command can be entered. For example, a tRCD specification of 20ns with a 125 MHz clock (8ns period) results in 2.5 clocks, rounded to 3. This is reflected in Figure 8 on page 19, which covers any case where 2 < tRCD (MIN)/tCK ≤ 3. (The same procedure is used to convert other specification limits from time units to clock cycles.) A subsequent ACTIVE command to a different row in the same bank can only be issued after the previous active row has been “closed” (precharged). The minimum time interval between successive ACTIVE commands to the same bank is defined by tRC. A subsequent ACTIVE command to another bank can be issued while the first bank is being accessed, which results in a reduction of total row-access overhead. The minimum time interval between successive ACTIVE commands to different banks is defined by t RRD. Figure 7: Activating a Specific Row in a Specific Bank Register CLK CKE HIGH CS# RAS# CAS# WE# Address BA0, BA1 Row Address Bank Address Don’t Care PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 18 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations Figure 8: Meeting tRCD (MIN) when 2 < tRCD (MIN)/tCK < 3 T0 T1 T2 NOP NOP T3 T4 CLK Command ACTIVE READ or WRITE tRCD Don’t Care READs READ bursts are initiated with a READ command, as shown in Figure 8. The starting column and bank addresses are provided with the READ command, and auto precharge is either enabled or disabled for that burst access. If auto precharge is enabled, the row being accessed is precharged at the completion of the burst. Note: For the generic READ commands used in the following illustrations, auto precharge is disabled. During READ bursts, the valid data-out element from the starting column address will be available following the CL after the READ command. Each subsequent data-out element will be valid by the next positive clock edge. Figure 5 on page 11 shows general timing for each possible CL setting. Upon completion of a burst, assuming no other commands have been initiated, the DQ will go High-Z. Data from any READ burst may be truncated with a subsequent READ command, and data from a fixed-length READ burst may be immediately followed by data from a READ command. In either case, a continuous flow of data can be maintained. The first data element from the new burst follows either the last element of a completed burst or the last desired data element of a longer burst that is being truncated. The new READ command should be issued x cycles before the clock edge at which the last desired data element is valid, where x = CL - 1. This is shown in Figure 10 on page 20 for CL = 2 and CL = 3; data element n + 3 is either the last of a burst of four or the last desired of a longer burst. The Mobile SDRAM uses a pipelined architecture and therefore does not require the 2n rule associated with a prefetch architecture. A READ command can be initiated on any clock cycle following a previous READ command. Full-speed random read accesses can be performed to the same bank, as shown in Figure 11 on page 21, or each subsequent READ may be performed to a different bank. Data from any READ burst may be truncated with a subsequent WRITE command, and data from a fixed-length READ burst may be immediately followed by data from a WRITE command (subject to bus turnaround limitations). The WRITE burst may be initiated on the clock edge immediately following the last (or last desired) data element from the READ burst, provided that I/O contention can be avoided. In a given system design, there may be a possibility that the device driving the input data will go Low-Z before the SDRAM DQ go High-Z. In this case, at least a single-cycle delay should occur between the last read data and the WRITE command. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 19 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations Figure 9: READ Command CLK CKE HIGH CS# RAS# CAS# WE# Column Address Address Enable auto precharge A10 Disable auto precharge Bank Address BA0, BA1 Don’t Care Figure 10: Consecutive READ Bursts T0 T1 T2 T3 T4 T5 T6 CLK Command READ Address Bank, Col n NOP NOP NOP NOP READ NOP X = 1 cycle Bank, Col b DOUT n DQ DOUT n+2 DOUT n+1 DOUT n+3 DOUT b CL = 2 T0 T1 T2 T3 T4 T5 T6 T7 CLK Command READ Address Bank, Col n NOP NOP NOP READ NOP NOP NOP X = 2 cycles Bank, Col b DOUT n DQ DOUT n+1 DOUT n+2 DOUT n+3 DOUT b CL = 3 Transitioning Data Note: PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN Don’t Care Each READ command may be issued to any bank. DQM is LOW. 20 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations Figure 11: Random READ Accesses T0 T1 T2 T3 T4 T5 CLK Command Address READ READ READ READ Bank, Col n Bank, Col a Bank, Col x Bank, Col m DOUT n DQ NOP NOP DOUT x DOUT a DOUT m CL = 2 T0 T1 T2 T3 T4 T5 T6 CLK Command READ READ READ READ Address Bank, Col n Bank, Col a Bank, Col x Bank, Col m DOUT n DQ NOP DOUT a NOP DOUT x NOP DOUT m CL = 3 Transitioning Data Note: Don’t Care Each READ command may be issued to any bank. DQM is LOW. The DQM input is used to avoid I/O contention, as shown in Figure 12 on page 22 and Figure 13 on page 22. The DQM signal must be asserted (HIGH) at least two clocks prior to the WRITE command (DQM latency is two clocks for output buffers) to suppress dataout from the READ. After the WRITE command is registered, the DQ will go High-Z (or remain High-Z), regardless of the state of the DQM signal, provided the DQM was active on the clock just prior to the WRITE command that truncated the READ command. If not, the second WRITE will be an invalid WRITE. For example, if DQM was LOW during T4 in Figure 14 on page 23, then the WRITEs at T5 and T7 would be valid, while the WRITE at T6 would be invalid. The DQM signal must be de-asserted prior to the WRITE command (DQM latency is zero clocks for input buffers) to ensure that the written data is not masked. Figure 13 on page 22 shows the case where the clock frequency allows for bus contention to be avoided without adding a NOP cycle, and Figure 14 on page 23 shows the case where the additional NOP is needed. A fixed-length READ burst may be followed by, or truncated with, a PRECHARGE command to the same bank (provided that auto precharge was not activated). The PRECHARGE command should be issued x cycles before the clock edge at which the last desired data element is valid, where x equals the CL minus one. This is shown in Figure 14 for each possible CL; data element n + 3 is either the last of a burst of four or the last desired of a longer burst. Following the PRECHARGE command, a subsequent command to the same bank cannot be issued until tRP is met. Note: PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN Part of the row precharge time is hidden during the access of the last data element(s). 21 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations In the case of a fixed-length burst being executed to completion, a PRECHARGE command issued at the optimum time (as described above) provides the same operation that would result from the same fixed-length burst with auto precharge. The disadvantage of the PRECHARGE command is that it requires that the command and address buses be available at the appropriate time to issue the command; the advantage of the PRECHARGE command is that it can be used to truncate fixed-length bursts. Figure 12: READ-to-WRITE T0 T1 T2 T3 T4 CLK DQM Command READ Address Bank, Col n NOP NOP NOP WRITE Bank, Col b tCK tHZ DOUT n DQ DIN b tDS Transitioning Data Note: Figure 13: Don’t Care A CL of three is used for illustration. The READ command may be issued to any bank, and the WRITE command may be issued to any bank. If a burst of one is used, then DQM is not required. READ-to-WRITE with Extra Clock Cycle T0 T1 T2 T3 T4 T5 CLK DQM Command Address READ NOP NOP NOP NOP WRITE Bank, Col b Bank, Col n tHZ DOUT n DQ DIN b tDS Transitioning Data Note: PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN Don’t Care A CL of three is used for illustration. The READ command may be issued to any bank, and the WRITE command may be issued to any bank. 22 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations Figure 14: READ-to-PRECHARGE T0 T1 T2 T3 T4 T5 T6 T7 CLK t RP Command READ NOP NOP NOP PRECHARGE NOP NOP ACTIVE X = 1 cycle Address Bank (a or all) Bank a, Col n DOUT n+2 DOUT n+1 DOUT n DQ Bank a, Row DOUT n+3 CL = 2 T0 T1 T2 T3 T4 T5 T6 T7 CLK t RP Command READ Address Bank a, Col n NOP NOP NOP PRECHARGE NOP NOP ACTIVE X = 2 cycles Bank (a or all) DOUT n+2 DOUT n+1 DOUT n DQ Bank a, Row DOUT n+3 CL = 3 Transitioning Data Note: Figure 15: Don’t Care DQM is LOW. Terminating a READ Burst T0 T1 T2 T3 T4 T5 T6 CLK Command READ Address Bank, Col n NOP NOP NOP BURST TERMINATE NOP NOP X = 1 cycle DOUT n DQ DOUT n+2 DOUT n+1 DOUT n+3 CL = 2 T0 T1 T2 T3 T4 T5 T6 T7 CLK Command READ Address Bank, Col n NOP NOP NOP BURST TERMINATE NOP NOP NOP X = 2 cycles DOUT n DQ DOUT n+1 DOUT n+2 DOUT n+3 CL = 3 Transitioning Data Note: PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN Don’t Care DQM is LOW. 23 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations Fixed-length READ bursts may be truncated with a BURST TERMINATE command, provided that auto precharge was not activated. The BURST TERMINATE command should be issued x cycles before the clock edge at which the last desired data element is valid, where x equals the CL minus one. This is shown in Figure 15 on page 23 for each possible CL; data element n + 3 is the last desired data element of a longer burst. WRITEs WRITE bursts are initiated with a WRITE command, as shown in Figure 16. The starting column and bank addresses are provided with the WRITE command and auto precharge is either enabled or disabled for that access. If auto precharge is enabled, the row being accessed is precharged at the completion of the burst. For the generic WRITE commands used in the following illustrations, auto precharge is disabled. During WRITE bursts, the first valid data-in element will be registered coincident with the WRITE command. Subsequent data elements will be registered on each successive positive clock edge. Upon completion of a fixed-length burst, assuming no other commands have been initiated, the DQ will remain High-Z and any additional input data will be ignored (see Figure 18 on page 25). Figure 16: WRITE Command CLK CKE HIGH CS# RAS# CAS# WE# Column Address Address Enable auto precharge A10 Disable auto precharge Bank Address BA0, BA1 Don’t Care Valid Address Data for any WRITE burst may be truncated with a subsequent WRITE command, and data for a fixed-length WRITE burst may be immediately followed by data for a WRITE command. The new WRITE command can be issued on any clock following the previous WRITE command, and the data provided coincident with the new command applies to the new command. An example is shown in Figure 19 on page 26. Data n + 1 is either the last of a burst of two or the last desired of a longer burst. The Mobile SDRAM uses a pipelined architecture and therefore does not require the 2n rule associated with a prefetch architecture. A WRITE command can be initiated on any clock cycle following a previous PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 24 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations WRITE command. Full-speed random write accesses within a page can be performed to the same bank, as shown in Figure 19 on page 26, or each subsequent WRITE may be performed to a different bank. Figure 17: WRITE Burst T0 T1 T2 T3 Command WRITE NOP NOP NOP Address Bank, Col n CLK DQ DIN n DIN n+1 Transitioning Data Note: Figure 18: Don’t Care BL = 2. DQM is LOW. WRITE-to-WRITE T0 T1 T2 Command WRITE NOP WRITE Address Bank, Col n CLK DQ DIN n Transitioning Data Note: Bank, Col b DIN n+1 DIN b Don’t Care DQM is LOW. Each WRITE command may be issued to any bank. Data for any WRITE burst may be truncated with a subsequent READ command, and data for a fixed-length WRITE burst may be immediately followed by a READ command. After the READ command is registered, the data inputs will be ignored and writes will not be executed. An example is shown in Figure 20 on page 26. Data n + 1 is either the last of a burst of two or the last desired of a longer burst. Data for a fixed-length WRITE burst may be followed by, or truncated with, a PRECHARGE command to the same bank (provided that auto precharge was not activated). The PRECHARGE command should be issued tWR after the clock edge at which the last desired input data element is registered. The auto precharge mode requires a t WR of at least one clock plus time, regardless of frequency. In addition, when truncating a WRITE burst, the DQM signal must be used to mask input data for the clock edge prior to, and the clock edge coincident with, the PRECHARGE command. An example is shown in Figure 21 on page 27. Data n + 1 is PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 25 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations either the last of a burst of two or the last desired of a longer burst. Following the PRECHARGE command, a subsequent command to the same bank cannot be issued until tRP is met. In the case of a fixed-length burst being executed to completion, a PRECHARGE command issued at the optimum time (as described above) provides the same operation that would result from the same fixed-length burst with auto precharge. The disadvantage of the PRECHARGE command is that it requires that the command and address buses be available at the appropriate time to issue the command; the advantage of the PRECHARGE command is that it can be used to truncate fixed-length bursts. Fixed-length WRITE bursts can be truncated with the BURST TERMINATE command. When truncating a WRITE burst, the input data applied coincident with the BURST TERMINATE command will be ignored. The last data written (provided that DQM is LOW at that time) will be the input data applied one clock previous to the BURST TERMINATE command. This is shown in Figure 22 on page 27, where data n is the last desired data element of a longer burst. Figure 19: Random WRITE Cycles T0 T1 T2 T3 Command WRITE WRITE WRITE WRITE Address Bank, Col n Bank, Col a Bank, Col x Bank, Col m DIN n DIN a DIN x DIN m CLK DQ Don’t Care Transitioning Data Note: Figure 20: Each WRITE command may be issued to any bank. DQM is LOW. WRITE-to-READ T0 T1 T2 T3 T4 T5 Command WRITE NOP READ NOP NOP NOP Address Bank, Col n DOUT b DOUT b+1 CLK DQ DIN n Bank, Col b DIN n+1 Transitioning Data Note: PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN Don’t Care The WRITE command may be issued to any bank, and the READ command may be issued to any bank. DQM is LOW. CL = 2 for illustration. 26 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations Figure 21: WRITE-to-PRECHARGE T0 T1 T2 T3 T4 T5 T6 NOP ACTIVE NOP CLK tWR @ tCLK ≥ 15ns DQM t RP Command Address WRITE NOP NOP PRECHARGE Bank (a or all) Bank a, Col n Bank a, Row t WR DQ DIN n+1 DIN n tWR = tCLK < 15ns DQM t RP Command Address WRITE NOP NOP PRECHARGE NOP Bank (a or all) Bank a, Col n NOP ACTIVE Bank a, Row t WR DQ DIN n+1 DIN n Transitioning Data Note: Figure 22: Don’t Care DQM could remain LOW in this example if the WRITE burst is a fixed length of two. Terminating a WRITE Burst T0 T1 WRITE BURST TERMINATE T2 CLK Command Address DQ Bank, Col n (Address) DIN n (Data) Transitioning Data Note: PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN NEXT COMMAND Don’t Care DQM is LOW. 27 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations PRECHARGE The PRECHARGE command (see Figure 23 on page 28) is used to deactivate the open row in a particular bank or the open row in all banks. The bank(s) will be available for a subsequent row access some specified time (tRP) after the PRECHARGE command is issued. Input A10 determines whether one or all banks are to be precharged, and in the case where only one bank is to be precharged, inputs BA0, BA1 select the bank. When all banks are to be precharged, inputs BA0, BA1 are treated as “Don’t Care.” After a bank has been precharged, it is in the idle state and must be activated prior to any READ or WRITE commands being issued to that bank. Figure 23: PRECHARGE Command CLK CKE HIGH CS# RAS# CAS# WE# Address All Banks A10 Bank Selected BA0, BA1 BANK ADDRESS Valid Address Don’t Care Power-Down Power-down occurs if CKE is registered LOW coincident with a NOP or COMMAND INHIBIT when no accesses are in progress. If power-down occurs when all banks are idle, this mode is referred to as precharge power-down; if power-down occurs when there is a row active in any bank, this mode is referred to as active power-down. Entering power-down deactivates the input and output buffers, excluding CKE, for maximum power savings while in standby. The device must not remain in the power-down state longer than the refresh period (64ms) since no refresh operations are performed in this mode. The power-down state is exited by registering an NOP or COMMAND INHIBIT and CKE HIGH at the desired clock edge (meeting tCKS). See Figure 24 on page 29. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 28 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations Figure 24: Power-Down (( )) (( )) CLK tCKS CKE > tCKS (( )) Command (( )) (( )) NOP NOP All banks idle Input buffers gated off Enter power-down mode Exit power-down mode ACTIVE tRCD tRAS tRC Deep Power-Down Deep power-down mode is a maximum power savings feature achieved by shutting off the power to the entire memory array of the device. Data on the memory array will not be retained after deep power-down mode is executed. Deep power-down mode is entered by having all banks idle then CS# and WE# held LOW with RAS# and CAS# HIGH at the rising edge of the clock, while CKE is LOW. CKE must be held LOW during deep power-down. To exit deep power-down mode, CKE must be asserted HIGH. Upon exit of deep powerdown mode, a full Mobile SDRAM initialization sequence is required. Clock Suspend The clock suspend mode occurs when a column access/burst is in progress and CKE is registered LOW. In the clock suspend mode, the internal clock is deactivated, “freezing” the synchronous logic. For each positive clock edge on which CKE is sampled LOW, the next internal positive clock edge is suspended. Any command or data present on the input pins at the time of a suspended internal clock edge is ignored; any data present on the DQ pins remains driven; and burst counters are not incremented, as long as the clock is suspended. (See examples in Figure 25 on page 30 and Figure 26 on page 30.) Clock suspend mode is exited by registering CKE HIGH; the internal clock and related operation will resume on the subsequent positive clock edge. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 29 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations Figure 25: Clock Suspend During WRITE Burst T0 T1 NOP WRITE T2 T3 T4 T5 CLK CKE Internal Clock Command NOP NOP DIN n+1 DIN n+2 Bank, Col n Address DIN n DIN Transitioning Data Note: Figure 26: Don’t Care For this example, BL = 4 or greater, and DM is LOW. Clock Suspend During READ Burst T0 T1 T2 T3 T4 T5 T6 CLK CKE Internal Clock Command READ Address Bank, Col n DQ NOP NOP NOP DOUT n DOUT n+1 Transitioning Data Note: PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN NOP DOUT n+2 NOP DOUT n+3 Don’t Care For this example, CL = 2, BL = 4 or greater, and DQM is LOW. 30 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations Burst Read/Single Write The burst read/single write mode is entered by programming the write burst mode bit (M9) in the mode register to a logic 1. In this mode, all WRITE commands result in the access of a single column location (burst of one), regardless of the programmed burst length. READ commands access columns according to the programmed burst length and sequence, just as in the normal mode of operation (M9 = 0). Concurrent Auto Precharge Micron SDRAM devices support concurrent auto precharge, which enables an access command (READ or WRITE) to another bank while an access command with auto precharge enabled is executing. Four cases where concurrent auto precharge occurs are defined below. READ with Auto Precharge 1. Interrupted by a READ (with or without auto precharge): A READ to bank m will interrupt a READ on bank n, two or three clocks later, depending on CL. The precharge to bank n will begin when the READ to bank m is registered (see Figure 27). 2. Interrupted by a WRITE (with or without auto precharge): When a WRITE to bank m registers, a READ on bank n will be interrupted. DQM should be used two clocks prior to the WRITE command to prevent bus contention. The precharge to bank n will begin when the WRITE to bank m is registered (see Figure 28 on page 32). Figure 27: READ with Auto Precharge Interrupted by a READ T0 T1 T2 T3 T4 T5 T6 T7 CLK Command Bank n Internal States NOP Page active READ - AP Bank n READ - AP Bank m NOP READ with BL = 4 NOP NOP NOP Idle Interrupt burst, precharge t RP - Bank n Bank m Page active Address Bank n, Col a NOP tRP - Bank m Precharge READ with BL = 4 Bank m, Col d DOUT a DQ DOUT a+1 DOUT d DOUT d+1 CL = 3 (Bank n) CL = 3 (Bank m) Transitioning Data Note: PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN Don’t Care DQM is LOW. 31 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations Figure 28: READ with Auto Precharge Interrupted by a WRITE T0 T1 T2 T3 T4 T5 T6 T7 CLK Command Bank n READ - AP Bank n NOP NOP NOP Page READ with BL = 4 Active Internal States WRITE - AP Bank m NOP NOP Interrupt burst, precharge Idle tRP - Bank n Page active Bank m Address NOP t WR - Bank m Write-Bank WRITE with BL = 4 Bank n, Col a Bank m, Col d DQM1 DOUT a DQ CL = 3 (Bank n) Note: DIN d DIN d+1 Transitioning Data DIN d+2 DIN d+3 Don’t Care DQM is HIGH at T2 to prevent DOUT a + 1 from contending with DIN d at T4. WRITE with Auto Precharge 3. Interrupted by a READ (with or without auto precharge): When a READ to bank m registers, it will interrupt a WRITE on bank n, with the data-out appearing 2 or 3 clocks later, depending on CL. The precharge to bank n will begin after tWR is met, where t WR begins when the READ to bank m is registered. The last valid WRITE to bank n will be data-in registered one clock prior to the READ to bank m (see Figure 29 on page 33). 4. Interrupted by a WRITE (with or without auto precharge): When a WRITE to bank m registers, it will interrupt a WRITE on bank n. The precharge to bank n will begin after t WR is met, where tWR begins when the WRITE to bank m is registered. The last valid data WRITE to bank n will be data registered one clock prior to a WRITE to bank m (see Figure 30 on page 33). PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 32 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations Figure 29: WRITE with Auto Precharge Interrupted by a READ T0 T1 T2 T3 T4 T5 T6 T7 CLK Command Bank n Internal States NOP Write - AP Bank n Page active NOP Read - AP Bank m WRITE with BL = 4 Bank m Address Bank n, Col a NOP NOP Precharge tRP - Bank n - Bank n tRP - Bank m READ with BL = 4 Bank m, Col d DOUT d+ 1 DOUT d DIN a+1 DIN a DQ NOP Interrupt burst, Write-back tWR Page active NOP CL = 3 (Bank m) Transitioning Data Note: Figure 30: Don’t Care DQM is LOW. WRITE with Auto Precharge Interrupted by a WRITE T0 T1 T2 T3 T4 T5 T6 T7 CLK Command Bank n Internal States NOP WRITE - AP Bank n Page active NOP NOP WRITE with BL = 4 WRITE - AP Bank m NOP Interrupt Burst, write-back tWR Bank m Page active - Bank n Address Bank n, Col a DIN a - Bank m Write-bank WRITE with BL = 4 Bank m, Col d DIN a+1 DIN a+2 DIN d DIN d+1 Transitioning Data PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN Precharge tRP - Bank n NOP tWR DQ Note: NOP DIN d+2 DIN d+3 Don’t Care DQM is LOW. 33 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations Table 6: Truth Table 2 – CKE Notes: 1–4; notes appear below table CKEn - 1 CKEn Current State Commandn Actionn L L Power-down Self refresh Clock suspend Deep power-down Power-down Deep power-down Self refresh Clock suspend All banks idle All banks idle All banks idle Reading or writing X X X X COMMAND INHIBIT or NOP X COMMAND INHIBIT or NOP X COMMAND INHIBIT or NOP BURST TERMINATE AUTO REFRESH VALID See Table 7 on page 35 Maintain power-down Maintain self refresh Maintain clock suspend Maintain deep power-down Exit power-down Exit deep power-down Exit self refresh Exit clock suspend Power-down entry Deep power-down entry Self refresh entry Clock suspend entry L H H L H H Notes: Notes 8 5 8 6 7 8 1. CKEn is the logic state of CKE at clock edge n; CKEn - 1 was the state of CKE at the previous clock edge. 2. Current state is the state of the SDRAM immediately prior to clock edge n. 3. COMMANDn is the command registered at clock edge n, and ACTIONn is a result of COMMANDn. 4. All states and sequences not shown are illegal or reserved. 5. Exiting power-down at clock edge n will put the device in the all banks idle state in time for clock edge n + 1 (provided that tCKS is met). 6. Exiting self refresh at clock edge n will put the device in the all banks idle state when tXSR is met. COMMAND INHIBIT or NOP commands should be issued on any clock edges occurring during the tXSR period. A minimum of two NOP commands must be provided during tXSR period. 7. After exiting clock suspend at clock edge n, the device will resume operation and recognize the next command at clock edge n + 1. 8. Deep power-down is a power-saving feature of this Mobile SDRAM device. This command is BURST TERMINATE when CKE is HIGH and deep power-down when CKE is LOW. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 34 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations Table 7: Truth Table 3 – Current State Bank n, Command to Bank n Notes: 1–5; notes appear below table and on next page Current State Any Idle Row active Read (auto precharge disabled) Write (auto precharge disabled) CS# RAS# CAS# H L L L L L L L L L L L L L L L L Notes: X H L L L L H H L H H L H H H L H X H H L L H L L H L L H H L L H H WE# X H H H L L H L L H L L L H L L L Command (Action) Notes COMMAND INHIBIT (NOP/Continue previous operation) NO OPERATION (NOP/Continue previous operation) ACTIVE (Select and activate row) AUTO REFRESH LOAD MODE REGISTER PRECHARGE READ (Select column and start READ burst) WRITE (Select column and start WRITE burst) PRECHARGE (Deactivate row in bank or banks) READ (Select column and start new READ burst) WRITE (Select column and start WRITE burst) PRECHARGE (Truncate READ burst, start PRECHARGE) BURST TERMINATE READ (Select column and start READ burst) WRITE (Select column and start new WRITE burst) PRECHARGE (Truncate WRITE burst, start PRECHARGE) BURST TERMINATE 6 6 10 9 9 7 9 9 7 8 9 9 7 8 1. This table applies when CKEn - 1 was HIGH and CKEn is HIGH (see Table 6 on page 34) and after tXSR has been met (if the previous state was self refresh). 2. This table is bank-specific, except where noted; for example, the current state is for a specific bank and the commands shown are those allowed to be issued to that bank when in that state. Exceptions are covered in the notes below. 3. Current state definitions: Idle: Row active: Read: Write: The bank has been precharged, and tRP has been met. A row in the bank has been activated, and tRCD has been met. No data bursts/ accesses and no register accesses are in progress. A READ burst has been initiated, with auto precharge disabled, and has not yet terminated or been terminated. A WRITE burst has been initiated, with auto precharge disabled, and has not yet terminated or been terminated. The following states must not be interrupted by a command issued to the same bank. COMMAND INHIBIT or NOP commands, or allowable commands to the other bank, should be issued on any clock edge occurring during these states. Allowable commands to the other bank are determined by its current state and Table 7, and according to Table 8. Precharging: Row activating: Read with auto precharge enabled: Write with auto precharge enabled: PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN Starts with registration of a PRECHARGE command and ends when tRP is met. After tRP is met, the bank will be in the idle state. Starts with registration of an ACTIVE command and ends when tRCD is met. After tRCD is met, the bank will be in the row active state. Starts with registration of a READ command with auto precharge enabled and ends when tRP has been met. After tRP is met, the bank will be in the idle state. Starts with registration of a WRITE command with auto precharge enabled and ends when tRP has been met. After tRP is met, the bank will be in the idle state. 35 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations 4. The following states must not be interrupted by any executable command; COMMAND INHIBIT or NOP commands must be applied on each positive clock edge during these states. Refreshing: Accessing mode register: Precharging all: Starts with registration of an AUTO REFRESH command and ends when t RFC is met. After tRFC is met, the SDRAM will be in the all banks idle state. Starts with registration of a LOAD MODE REGISTER command and ends when tMRD has been met. After tMRD is met, the SDRAM will be in the all banks idle state. Starts with registration of a PRECHARGE ALL command and ends when t RP is met. After tRP is met, all banks will be in the idle state. 5. All states and sequences not shown are illegal or reserved. 6. Not bank specific; requires that all banks are idle. 7. May or may not be bank specific; if all banks are to be precharged, all must be in a valid state for precharging. 8. Not bank specific; BURST TERMINATE affects the most recent WRITE or READ burst, regardless of bank. 9. READs or WRITEs listed in the Command (Action) column include READs or WRITEs with auto precharge enabled and READs or WRITEs with auto precharge disabled. 10. Does not affect the state of the bank and acts as a NOP to that bank. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 36 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations Table 8: Truth Table 4 – Current State Bank n, Command to Bank m Notes: 1–6; notes appear below table and on next page Current State CS# RAS# CAS# WE# Any H L X L L L L L L L L L L L L L L L L L L L L X H X L H H L L H H L L H H L L H H L L H H L X H X H L L H H L L H H L L H H L L H H L L H X H X H H L L H H L L H H L L H H L L H H L L Idle Row activating, active, or precharging Read (auto precharge disabled) Write (auto precharge disabled) Read (with auto precharge) Write (with auto precharge) Notes: Command (Action) COMMAND INHIBIT (NOP/Continue previous operation) NO OPERATION (NOP/Continue previous operation) Any command otherwise allowed to bank m ACTIVE (Select and activate row) READ (Select column and start READ burst) WRITE (Select column and start WRITE burst) PRECHARGE ACTIVE (Select and activate row) READ (Select column and start new READ burst) WRITE (Select column and start WRITE burst) PRECHARGE ACTIVE (Select and activate row) READ (Select column and start READ burst) WRITE (Select column and start new WRITE burst) PRECHARGE ACTIVE (Select and activate row) READ (Select column and start new READ burst) WRITE (Select column and start WRITE burst) PRECHARGE ACTIVE (Select and activate row) READ (Select column and start READ burst) WRITE (Select column and start new WRITE burst) PRECHARGE Notes 7 7 7, 10 7, 11 9 7, 12 7, 13 9 7, 8, 14 7, 8, 15 9 7, 8, 16 7, 8, 17 9 1. This table applies when CKEn-1 was HIGH and CKEn is HIGH (see Table 6 on page 34) and after tXSR has been met (if the previous state was self refresh). 2. This table describes alternate bank operation, except where noted; i.e., the current state is for bank n and the commands shown are those allowed to be issued to bank m (assuming that bank m is in such a state that the given command is allowable). Exceptions are covered in the notes below. 3. Current state definitions: Idle: Row active: Read: Write: Read with auto precharge enabled: Write with auto precharge enabled: The bank has been precharged, and tRP has been met. A row in the bank has been activated, and tRCD has been met. No data bursts/accesses and no register accesses are in progress. A READ burst has been initiated with auto precharge disabled and has not yet terminated or been terminated. A WRITE burst has been initiated with auto precharge disabled and has not yet terminated or been terminated. Starts with registration of a READ command with auto precharge enabled and ends when tRP has been met. After tRP is met, the bank will be in the idle state. Starts with registration of a WRITE command with auto precharge enabled and ends when tRP has been met. After tRP is met, the bank will be in the idle state. 4. AUTO REFRESH, SELF REFRESH, and LOAD MODE REGISTER commands may only be issued when all banks are idle. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 37 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Operations 5. A BURST TERMINATE command cannot be issued to another bank; it applies to the bank represented by the current state only. 6. All states and sequences not shown are illegal or reserved. 7. READs or WRITEs to bank m listed in the Command (Action) column include READs or WRITEs with auto precharge enabled and READs or WRITEs with auto precharge disabled. 8. Concurrent auto precharge: Bank n will initiate the auto precharge command when its burst has been interrupted by bank m’s burst. 9. Burst in bank n continues as initiated. 10. For a READ without auto precharge interrupted by a READ (with or without auto precharge), the READ to bank m will interrupt the READ on bank n, CL later (see Figure 10 on page 20). 11. For a READ without auto precharge interrupted by a WRITE (with or without auto precharge), the WRITE to bank m will interrupt the READ on bank n when registered (see Figure 12 on page 22 and Figure 13 on page 22). DQM should be used one clock prior to the WRITE command to prevent bus contention. 12. For a WRITE without auto precharge interrupted by a READ (with or without auto precharge), the READ to bank m will interrupt the WRITE on bank n when registered (see Figure 20 on page 26), with the data-out appearing CL later. The last valid WRITE to bank n will be data-in registered one clock prior to the READ to bank m. 13. For a WRITE without auto precharge interrupted by a WRITE (with or without auto precharge), the WRITE to bank m will interrupt the WRITE on bank n when registered (see Figure 18 on page 25). The last valid WRITE to bank n will be data-in registered one clock prior to the READ to bank m. 14. For a READ with auto precharge interrupted by a READ (with or without auto precharge), the READ to bank m will interrupt the READ on bank n, CL later (see Figure 27 on page 31). The PRECHARGE to bank n will begin when the READ to bank m is registered. 15. For a READ with auto precharge interrupted by a WRITE (with or without auto precharge), the WRITE to bank m will interrupt the READ on bank n when registered (see Figure 28 on page 32). DQM should be used two clocks prior to the WRITE command to prevent bus contention. The PRECHARGE to bank n will begin when the WRITE to bank m is registered. 16. For a WRITE with auto precharge interrupted by a READ (with or without auto precharge), the READ to bank m will interrupt the WRITE on bank n when registered, with the data-out appearing CL later (see Figure 29 on page 33). The PRECHARGE to bank n will begin after tWR is met, where tWR begins when the READ to bank m is registered. The last valid WRITE bank n will be data-in registered one clock prior to the READ to bank m. 17. For a WRITE with auto precharge interrupted by a WRITE (with or without auto precharge), the WRITE to bank m will interrupt the WRITE on bank n when registered. The PRECHARGE to bank n will begin after tWR is met, where tWR begins when the WRITE to bank m is registered (see Figure 30 on page 33). The last valid WRITE to bank n will be data registered one clock to the WRITE to bank m. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 38 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Electrical Specifications Electrical Specifications Stresses greater than those listed may cause permanent damage to the device. This is a stress rating only, and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. Table 9: Absolute Maximum Ratings Parameter Voltage on VDD/VDDQ supply relative to VSS/VSSQ Voltage on any ball relative to VSS Storage temperature (plastic) Table 10: Symbol Min Max Units VDD/VDDQ VIN TSTG –0.35 –0.35 –55 +2.8 +2.8 +150 V V °C DC Electrical Characteristics and Operating Conditions Notes: 1, 5, 6; notes appear on page 43 and 44; VDD/VDDQ = 1.7–1.95V Parameter/Condition Symbol Supply voltage I/O supply voltage Input high voltage: Logic 1; All inputs Input low voltage: Logic 0; All inputs Output high voltage: all inputs: IOUT = -100µA Input low voltage: all inputs: IOUT = 100µA Input leakage current: Any input 0V ≤ VIN ≤ VDD (All other pins not under test = 0V) Output leakage current: DQ disabled; 0V ≤ VOUT ≤ VDDQ Operating temperature Commercial Industrial Table 11: VDD VDDQ VIH VIL VOH VOL II IOZ TA Min Max Units 1.7 1.95 1.7 1.95 0.8 × VDDQ VDDQ + 0.3 –0.3 +0.3 0.9 × VDDQ – – 0.2 –1.0 +1.0 –1.5 +1.5 0 –40 +70 +85 V V V V V V µA Notes 22 22 µA °C AC Electrical Characteristics and Operating Conditions VDD/VDDQ = 1.7–1.95V Parameter/Condition Input high voltage: Logic 1; All inputs Input low voltage: Logic 0; All inputs PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 39 Symbol Min Max Units VIH VIL 1.4 – – 0.4 V V Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Electrical Specifications Table 12: Electrical Characteristics and Recommended AC Operating Conditions Notes: 5, 6, 8, 9, and 11; notes appear on page 43 and 44 AC Characteristics -75 Parameter Access time from CLK (positive edge) Address hold time Address setup time CLK high-level width CLK low-level width Clock cycle time CKE hold time CKE setup time CS#, RAS#, CAS#, WE#, DQM hold time CS#, RAS#, CAS#, WE#, DQM setup time Data-in hold time Data-in setup time Data-out High-Z time Data-out Low-Z time Data-out hold time (load) Data-out hold time (no load) ACTIVE-to-PRECHARGE command ACTIVE-to-ACTIVE command period ACTIVE-to-READ or WRITE delay Refresh period (4,096 rows) AUTO REFRESH period PRECHARGE command period ACTIVE bank a to ACTIVE bank b command Transition time WRITE recovery time Exit SELF REFRESH-to-ACTIVE command PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN Symbol CL = 3 CL = 2 CL = 3 CL = 2 CL = 3 CL = 2 t AC (3) AC (2) t AH tAS t CH t CL tCK (3) tCK (2) t CKH tCKS tCMH tCMS tDH tDS tHZ (3) tHZ (2) tLZ tOH t OHN tRAS tRC tRCD tREF tRFC tRP tRRD tT tWR t XSR t 40 -8 Min Max Min Max Units – – 1 2.5 3 3 7.5 9.6 1 2.5 1 2.5 1 2.5 – – 1 2.5 1.8 45 67.5 19.2 – 75 19.2 15 0.5 15 75 6 8 – – – – 100 100 – – – – – – 6 8 – – – 120,000 – – 64 – – – 1.2 – – – – 1 2.5 3 3 8 12 1 2.5 1 2.5 1 2.5 – – 1 2.5 1.8 48 72 24 – 80 24 16 0.5 15 80 6 8 – – – – 100 100 – – – – – – 6 8 – – – 120,000 – – 64 – – – 1.2 – – ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ms ns ns ns ns ns ns Notes 23 23 10 10 26 7 24 20 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Electrical Specifications Table 13: AC Functional Characteristics Notes: 5, 6, 8, 9, and 11; notes appear on page 43 and 44 Parameter Symbol READ/WRITE command to READ/WRITE command CKE to clock disable or power-down entry mode CKE to clock enable or power-down exit setup mode DQM to input data delay DQM to data mask during WRITEs DQM to data High-Z during READs WRITE command to input data delay Data-in to ACTIVE command Data-in to PRECHARGE command Last data-in to burst STOP command Last data-in to new READ/WRITE command Last data-in to PRECHARGE command LOAD MODE REGISTER command to ACTIVE or REFRESH command Data-out to High-Z from PRECHARGE command Table 14: -75 t Units Notes CCD CKED t PED t DQD tDQM t DQZ t DWD t DAL t DPL t BDL t CDL tRDL tMRD 1 1 1 0 0 2 0 5 2 1 1 2 2 1 1 1 0 0 2 0 5 2 1 1 2 2 t CK CK t CK t CK tCK t CK t CK t CK t CK t CK t CK tCK tCK 17 14 14 17 17 17 17 15, 21 16, 21 17 17 16, 21 24 tROH(3) 3 2 3 2 tCK 17 17 t CL = 3 CL = 2 -8 tROH(2) t tCK IDD Specifications and Conditions (x16) Notes: 1, 5, 6, 11, and 13; notes appear on page 43 and 44; VDD = 1.7V–1.95V, VDDQ = 1.7V–1.95V Max Parameter/Condition Operating current: Active mode; Burst = 1; READ or WRITE; tRC = tRC (MIN) Standby current: Power-down mode; All banks idle; CKE = LOW Standby current: Nonpower-down mode; All banks idle; CKE = HIGH Standby current: Active mode; CKE = LOW; CS# = HIGH; All banks active; No accesses in progress Standby current: Active mode; CKE = HIGH; CS# = HIGH; All banks active after tRCD met; No accesses in progress Operating current: Burst mode; Continuous burst; READ or WRITE; All banks active, half DQ toggling every cycle tRFC = tRFC (MIN) Auto refresh current: CKE = HIGH; CS# = HIGH tRFC = 15.625µs Deep power-down PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 41 Symbol -75 -8 Units Notes IDD1 60 55 mA IDD2P 150 150 µA 3, 18, 19 25 IDD2N 10 10 mA IDD3P 5 5 mA IDD3N 15 15 mA 3, 18, 19 IDD4 50 50 mA 3, 18, 19 IDD5 75 60 mA IDD6 2 2 mA IZZ 10 10 µA 3, 12, 18, 19 3, 12, 18, 19, 26 25, 27 3, 12, 19, 25 3, 18, 19 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Electrical Specifications Table 15: IDD7 - Self Refresh Current Options Notes: 4, 13, 25, and 28; notes appear on page 43 and 44; VDD/VDDQ = 1.7–1.95V Temperature-Compensated Self Refresh Parameter/Condition Max Temperature -75/-8 Units 85ºC 45ºC 85ºC 45ºC 85ºC 45ºC 85ºC 45ºC 85ºC 45ºC 180 120 130 80 100 80 100 80 100 80 µA µA µA µA µA µA µA µA µA µA Self refresh current: CKE < 0.2V – 4 banks open Self refresh current: CKE < 0.2V – 2 banks open Self refresh current: CKE < 0.2V – 1 bank open Self refresh current: CKE < 0.2V – 1/2 bank open Self refresh current: CKE < 0.2V – 1/4 bank open Figure 31: Typical Self Refresh Current vs. Temperature 100 4-Banks 90 2-Banks 1-Bank, 1/2 Bank, 1/4 Bank 80 Current (µA) 70 60 50 40 30 20 10 0 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 Temperature (C) Table 16: Capacitance Note: 2; notes appear on page 43 Parameter Input capacitance: CLK Input capacitance: All other input-only pins Input/output capacitance: DQ PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 42 Symbol Min Max Units CI1 CI2 CIO 1.5 1.5 3.0 4.0 4.0 6.0 pF pF pF Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Notes Notes 1. All voltages referenced to VSS. 2. This parameter is sampled. VDD/VDDQ = 1.7–1.95V; TA = 25°C; pin under test biased at 1.4V. f = 1 MHz. 3. IDD is dependent on output loading and cycle rates. Specified values are obtained with minimum cycle time and the outputs open. 4. Enables on-chip refresh and address counters. 5. The minimum specifications are used only to indicate cycle time at which proper operation over the full temperature range (0°C ≤ TA ≤ +70°C for commercial parts; –40°C ≤ TA ≤ +85°C for industrial parts) is ensured. 6. An initial pause of 100µs is required after power-up, followed by two AUTO REFRESH commands, before proper device operation is ensured. (VDD and VDDQ must be powered up simultaneously. VSS and VSSQ must be at same potential.) The two AUTO REFRESH command wake-ups should be repeated any time the tREF refresh requirement is exceeded. 7. AC characteristics assume tT = 1ns. 8. In addition to meeting the transition rate specification, the clock and CKE must transition between VIH and VIL (or between VIL and VIH) in a monotonic manner. 9. Outputs measured for 1.8V at 0.9V with equivalent load: Q 20pF 10. tHZ defines the time at which the output achieves the open circuit condition; it is not a reference to VOH or VOL. The last valid data element will meet tOH before going High-Z. 11. AC timing and IDD tests have VIL and VIH, with timing referenced to VIH/2 = crossover point. If the input transition time is longer than tT (MAX), then the timing is referenced at VIL (MAX) and VIH (MIN) and no longer at the VIH/2 crossover point. 12. Other input signals are allowed to transition no more than once every two clocks and are otherwise at valid VIH or VIL levels. 13. IDD specifications are tested after the device is properly initialized. 14. Timing actually specified by tCKS; clock(s) specified as a reference only at minimum cycle rate. 15. Timing actually specified by tWR plus tRP; clock(s) specified as a reference only at minimum cycle rate. 16. Timing actually specified by tWR. 17. Required clocks are specified by JEDEC functionality and are not dependent on any timing parameter. 18. The IDD current will increase or decrease proportionally according to the amount of frequency alteration for the test condition. 19. Address transitions average one transition every two clocks. 20. CLK must be toggled a minimum of two times during this period. 21. Based on tCK = 7.5ns for -75 and tCK = 8.0ns for -8. 22. VIH overshoot: VIH (MAX) = VDDQ + 2V for a pulse width ≤3ns, and the pulse width cannot be greater than one-third of the cycle rate. VIL undershoot: VIL (MIN) = -2V for a pulse width ≤3ns. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 43 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Notes 23. The clock frequency must remain constant (stable clock is defined as a signal cycling within timing constraints specified for the clock pin) during access or precharge states (READ, WRITE, including tWR, and PRECHARGE commands). CKE may be used to reduce the data rate. 24. For auto precharge mode, at least one clock cycle is required during tWR. During auto precharge mode, the precharge timing budget (tRP) begins at 7.5ns for -75, and 7ns for -8, after the first clock delay after the last WRITE is executed. 25. Measurement is taken 500ms after entering this operating mode to allow for tester measurement settling time. 26. CKE is HIGH during REFRESH command period tRFC (MIN) else CKE is LOW. The IDD6 limit is actually a nominal value and does not result in a fail value. 27. Deep power-down current is a nominal value at 25°C. The parameter is not tested. 28. Values for IDD7 85°C are guaranteed for the entire temperature range. All other IDD7 values are estimated. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 44 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Timing Diagrams Timing Diagrams Figure 32: Initialize and Load Mode Register T0 CLK (( )) (( )) Tn + 1 T1 tCK To + 1 Tp + 1 Tq + 1 Tr + 1 (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) tCKS tCKH CKE (( )) (( )) Command1 (( )) (( )) DQM (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) A0–A9, A11 (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) Code (( )) (( )) Code (( )) (( )) Valid (( )) (( )) A10 (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) Code (( )) (( )) Code (( )) (( )) Valid (( )) (( )) BA0, BA1 (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) BA0 BA0 == L, L, BA1 BA1==HL (( )) (( )) Valid (( )) (( )) DQ (( )) (( )) (( )) (( )) tRP tRFC2 tCMS tCMH NOP (( )) (( )) PRE AR (( )) (( )) AR (( )) (( )) LMR (( )) (( )) LMR (( )) (( )) (( )) (( )) VALID (( )) (( )) (( )) (( )) (( )) (( )) tAS tAH All Banks t AS tAH tAS tAH High-Z BA0 = L, BA1 = L (( )) (( )) (( )) T = 100µs Power-up: VDD and CLK stable Notes: tRFC2 tMRD3 Load mode register Precharge all banks tMRD3 Load extended mode register 1. PRE = PRECHARGE command, AR = AUTO REFRESH command, and LMR = LOAD MODE REGISTER command. 2. Only NOPs or COMMAND INHIBITs may be issued during tRFC time. 3. At least one NOP or COMMAND INHIBIT is required during tMRD time. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 45 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Timing Diagrams Figure 33: Power-Down Mode T0 T1 tCK CLK T2 (( )) (( )) tCL tCKS tCH CKE tCKS Tn + 2 tCKS (( )) tCKH tCMS tCMH Command Tn + 1 PRECHARGE NOP (( )) (( )) NOP NOP ACTIVE DQM (( )) (( )) A0–A9, A11 (( )) (( )) Row (( )) (( )) Row (( )) (( )) Bank All banks A10 Single bank tAS BA0, BA1 tAH Banks\S) High-Z (( )) DQ Two clock cycles Input buffers gated off while in power-down mode Precharge all active banks All banks idle All banks idle, enter power-down mode Exit power-down mode Don’t Care Notes: 1. Violating refresh requirements during power-down may result in a loss of data. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 46 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Timing Diagrams Figure 34: Clock Suspend Mode T0 T1 T2 tCK CLK T3 T4 T5 T6 T7 T8 T9 tCL tCH tCKS tCKH CKE tCKS tCKH tCMS tCMH Command READ NOP NOP NOP NOP NOP WRITE NOP tCMS tCMH DQM tAS A0–A9, A11 tAH Column m 2 tAS tAH tAS tAH Column e 2 A10 BA0, BA1 Bank Bank tAC tOH tAC DQ tLZ tHZ DOUT m DOUT m + 1 tDS tDH DOUT e DOUT e + 1 Don’t Care Undefined Notes: 1. For this example, the BL = 2, the CL = 3, and auto precharge is disabled. 2. A8, A9, and A11 = “Don’t Care.” PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 47 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Timing Diagrams Figure 35: Auto Refresh Mode T0 T1 CLK tCK T2 (( )) (( )) tCH tCKS tCKH tCMS tCMH PRECHARGE NOP AUTO REFRESH NOP A0–A9, A11 All banks A10 Single bank tAS DQ (( )) ( ( NOP )) To + 1 (( )) AUTO REFRESH NOP (( )) (( )) DQM BA0, BA1 (( )) (( )) (( )) CKE Command Tn + 1 tCL (( )) ( ( NOP )) ACTIVE (( )) (( )) (( )) (( )) (( )) (( )) Row (( )) (( )) (( )) (( )) Row tAH Bank(S) High-Z tRP tRFC1 (( )) (( )) (( )) (( )) (( )) (( )) Bank tRFC1 Precharge all active banks Don’t Care Note: PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN tRFC must not be interrupted by any executable command; Command INHIBIT or NOP commands must be applied on any positive edge during tRFC. 48 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Timing Diagrams Figure 36: Self Refresh Mode T0 CLK T1 tCK tCL tCH T2 tCKS CKE Command tCKS tCKH tCMS tCMH AUTO1 REFRESH NOP DQM A0–A9, A11 All Banks A10 Single Bank BA0, BA1 DQ > tRAS (( )) (( )) To + 1 To + 2 (( )) (( )) (( )) PRECHARGE tAS Tn + 1 (( )) (( )) (( )) (( )) (( )) AUTO1 REFRESH NOP ( ( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) tAH Bank(s) High-Z (( )) (( )) tRP Precharge all active banks tXSR Enter self refresh mode Exit self refresh mode (Restart refresh time base) CLK stable prior to exiting self refresh mode Note: PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN tXSR Don’t Care requires a minimum of two clocks regardless of frequency or timing. 49 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Timing Diagrams Figure 37: READ – Without Auto Precharge T0 T1 T2 tCK CLK T3 T4 T5 NOP NOP T6 T7 T8 NOP ACTIVE tCL tCH tCKS tCKH CKE tCMS tCMH Command ACTIVE NOP READ NOP PRECHARGE tCMS tCMH DQM tAS A0–A9, A11 tAS Column m 2 Row tAH All banks Row A10 tAS BA0, BA1 tAH Row Row Single banks Disable auto precharge tAH Bank Bank Bank(s) tAC DQ tLZ tRCD tAC tOH DOUT m tAC tOH DOUT m+1 Bank tAC tOH tOH DOUT m+2 DOUT m+3 tHZ tRP CAS latency tRAS tRC Don’t Care Undefined Notes: 1. For this example, the BL = 4, the CL = 2, and the READ burst is followed by a “manual” PRECHARGE. 2. A8, A9, and A11 = “Don’t Care.” PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 50 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Timing Diagrams Figure 38: READ – with Auto Precharge T0 T1 tCK CLK tCKS T2 T3 T4 T5 NOP NOP T6 T7 T8 NOP ACTIVE tCL tCH tCKH CKE tCMS tCMH Command ACTIVE NOP READ tCMS NOP NOP tCMH DQM tAS A0–A9, A11 tAH tAS A10 tAH Row Enable auto precharge Row tAS BA0, BA1 Column m 2 Row Row tAH Bank Bank Bank tAC tOH tAC DQ tLZ tRCD DOUT m tAC tOH DOUT m + 1 tAC tOH DOUT m + 2 tOH DOUT m + 3 tHZ tRP CAS latency tRAS tRC Don’t Care Undefined Notes: 1. For this example, the BL = 4, and the CL = 2. 2. A8, A9, and A11 = “Don’t Care.” PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 51 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Timing Diagrams Figure 39: Single READ – Without Auto Precharge T0 T1 T2 tCK CLK T3 T4 T5 NOP 3 NOP 3 T6 T7 T8 tCL tCH tCKS tCKH CKE tCMS tCMH Command ACTIVE NOP READ PRECHARGE NOP ACTIVE NOP tCMS tCMH DQM tAS A0–A9, A11 Column m2 Row tAS Row tAH All banks Row A10 tAS BA0, BA1 tAH Row Disable auto precharge tAH Bank Single banks Bank Bank(S) tAC DQ t LZ tRCD Bank tOH DOUT m tHZ tRP CAS latency tRAS tRC Don’t Care Undefined Notes: 1. For this example, the BL = 4, the CL = 2, and the READ burst is followed by a “manual” PRECHARGE. 2. A8, A9, and A11 = “Don’t Care.” 3. PRECHARGE command not allowed, or tRAS would be violated. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 52 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Timing Diagrams Figure 40: Single READ – with Auto Precharge T0 T1 tCK CLK tCKS T2 T3 T4 T5 T6 T7 T8 tCL tCH tCKH CKE tCMS tCMH Command ACTIVE NOP NOP3 NOP3 READ tCMS NOP NOP ACTIVE NOP tCMH DQM tAS A0–A9, A11 tAS A10 Column m 2 tAH Row Enable auto precharge Row tAS BA0, BA1 tAH Row Row tAH Bank Bank Bank tAC t OH DOUT m DQ tRCD CAS latency tHZ tRP tRAS tRC Don’t Care Undefined Notes: 1. For this example, the BL = 4 and the CL = 2. 2. A8, A9, and A11 = “Don’t Care.” 3. PRECHARGE command not allowed, or tRAS would be violated. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 53 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Timing Diagrams Figure 41: Alternating Bank Read Accesses T0 T1 tCK CLK T2 T3 T4 T5 NOP ACTIVE T6 T7 T8 READ NOP ACTIVE tCL tCH tCKS tCKH tCMS tCMH CKE Command ACTIVE NOP READ tCMS NOP tCMH DQM tAS A0–A9, A11 tAS A10 2 Column m tAH Column b2 Row Enable auto precharge Row Enable auto precharge Row tAS BA0, BA1 tAH Row Row Row tAH Bank 0 Bank 0 Bank 3 tAC DQ tLZ tRCD - Bank 0 Bank 3 tAC tOH DOUT m tAC tOH DOUT m + 1 Bank 0 tAC tOH DOUT m + 2 tAC tOH DOUT m + 3 tRP - Bank 0 CAS latency - Bank 0 tAC tOH DOUT b tRCD - Bank 0 tRAS - Bank 0 tRC - Bank 0 tRCD - Bank 3 tRRD CAS latency - Bank 3 Don’t Care Undefined Notes: 1. For this example, the BL = 4, and the CL = 2. 2. A8, A9, and A11 = “Don’t Care.” PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 54 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Timing Diagrams Figure 42: READ – DQM Operation T0 T1 tCK CLK tCKS tCKH tCMS tCMH T2 T3 T4 T5 NOP NOP T6 T7 T8 NOP NOP NOP tCL tCH CKE Command ACTIVE NOP READ tCMS NOP tCMH DQM tAS A0–A9, A11 tAH Enable auto precharge Row tAS BA0, BA1 Column m 2 Row tAS A10 tAH Disable auto precharge tAH Bank Bank tAC tOH DQ tAC DOUT m tLZ tRCD tHZ tAC tOH DOUT m + 2 tLZ tOH DOUT m + 3 tHZ CAS latency Don’t Care Undefined Notes: 1. For this example, the CL = 2. 2. A8, A9, and A11 = “Don’t Care.” PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 55 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Timing Diagrams Figure 43: WRITE – Without Auto Precharge T0 tCK CLK T1 T2 tCL T3 T4 T5 T6 T7 T8 T9 NOP NOP NOP NOP PRECHARGE NOP ACTIVE tCH tCKS tCKH tCMS tCMH CKE Command ACTIVE NOP WRITE tCMS tCMH DQM tAS A0–A9, A11 tAS A10 Column m 3 Row tAH All banks Row tAS BA0, BA1 tAH Row Row tAH Disable auto precharge Single bank Bank Bank Bank tDS tDH DIN m DQ tDS tDH DIN m + 1 tDS tDH tDS DIN m + 2 Bank tDH DIN m + 3 t WR 2 tRCD tRAS tRP tRC Don’t Care Notes: 1. For this example, the BL = 4, and the WRITE burst is followed by a “manual” PRECHARGE. 2. 15ns is required between <DIN m + 3> and the PRECHARGE command, regardless of frequency. 3. A8, A9, and A11 = “Don’t Care.” PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 56 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Timing Diagrams Figure 44: WRITE – with Auto Precharge T0 tCK CLK tCKS tCKH tCMS tCMH T1 T2 tCL T3 T4 T5 T6 T7 T8 T9 NOP NOP NOP NOP NOP NOP ACTIVE tCH CKE Command ACTIVE NOP WRITE tCMS tCMH DQM tAS A0–A9, A11 tAH Row Enable auto precharge Row tAS BA0, BA1 Column m 2 Row tAS A10 tAH Row tAH Bank Bank Bank tDS tDH DIN m DQ tDS tDH DIN m + 1 tDS tDH DIN m + 2 tRCD tRAS tDS tDH DIN m + 3 tWR tRP tRC Don’t Care Notes: 1. For this example, the BL = 4. 2. A8, A9, and A11 = “Don’t Care.” PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 57 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Timing Diagrams Figure 45: Single WRITE – Without Auto Precharge T0 tCK CLK T1 T2 tCL T3 T4 NOP 4 NOP 4 T5 T6 T7 T8 ACTIVE NOP tCH tCKS tCKH tCMS tCMH CKE Command ACTIVE NOP WRITE PRECHARGE NOP tCMS tCMH DQM tAS A0–A9, A11 tAH All banks Row Row tAS BA0, BA1 Column m3 Row tAS A10 tAH Disable auto precharge tAH Bank Single bank Bank Bank tDS Bank tDH DIN m DQ tRCD tRAS tRP t WR 2 tRC Don’t Care Notes: 1. 2. 3. 4. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN For this example, the BL = 1, and the WRITE burst is followed by a “manual” PRECHARGE. 15ns is required between <DIN m> and the PRECHARGE command, regardless of frequency. A8, A9, and A11 = “Don’t Care.” PRECHARGE command not allowed or tRAS would be violated. 58 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Timing Diagrams Figure 46: Single WRITE – with Auto Precharge T0 tCK CLK tCKS tCKH tCMS tCMH T1 tCL T2 T3 T4 T5 T6 T7 NOP4 WRITE NOP NOP NOP T8 T9 tCH CKE Command NOP4 ACTIVE NOP4 tCMS ACTIVE NOP tCMH DQM tAS A0–A9, A11 tAS Column m3 tAH Row Enable Auto Precharge Row A10 tAS BA0, BA1 tAH Row Row tAH Bank Bank Bank tDS tDH DIN m 2 DQ tRCD tRAS tWR tRP tRC Don’t Care Notes: 1. 2. 3. 4. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN For this example, the BL = 1. 15ns is required between <DIN m> and the PRECHARGE command, regardless of frequency. A8, A9, and A11 = “Don’t Care.” WRITE command not allowed or tRAS would be violated. 59 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Timing Diagrams Figure 47: Alternating Bank Write Accesses T0 tCK CLK T1 T2 tCL T3 T4 T5 T6 T7 T8 T9 NOP NOP ACTIVE tCH tCKS tCKH tCMS tCMH CKE Command ACTIVE NOP WRITE tCMS NOP ACTIVE NOP WRITE tCMH DQM tAS A0–A9, A11 tAS A10 Column m 2 tAH Column b 2 Row Enable auto precharge Row Enable auto precharge Row tAS BA0, BA1 tAH Row Row Row tAH Bank 0 Bank 0 tDS tDH DIN m DQ Bank 1 tDS tDH DIN m + 1 tDS Bank 1 tDH tDS DIN m + 2 tDH DIN m + 3 tDS tDH DIN b tWR - Bank 0 tRCD - Bank 0 Bank 0 tDS tDH DIN b + 1 tRP - Bank 0 tDS tDH DIN b + 2 tDS tDH DIN b + 3 tRCD - Bank 0 tRAS - Bank 0 tRC - Bank 0 tRCD - Bank 1 tRRD tWR - Bank 1 Don’t Care Notes: 1. For this example, the BL = 4. 2. A8, A9, and A11 = “Don’t Care.” PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 60 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Timing Diagrams Figure 48: WRITE – DQM Operation T0 T1 tCK CLK T2 T3 T4 T5 NOP NOP NOP T6 T7 NOP NOP tCL tCH tCKS tCKH tCMS tCMH CKE Command ACTIVE NOP WRITE tCMS tCMH DQM tAS A0–A9, A11 tAH Enable auto precharge Row tAS BA0, BA1 Column m2 Row tAS A10 tAH tAH Disable auto precharge Bank Bank tDS tDH tDS DIN m DQ tDH DIN m + 2 tDS tDH DIN m + 3 tRCD Don’t Care Notes: 1. For this example, the BL = 4. 2. A8, A9, and A11 = “Don’t Care.” PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 61 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved. 64Mb: 4 Meg x 16 Mobile SDRAM Package Dimensions Package Dimensions Figure 49: 54-Ball VFBGA (8mm x 8mm) 0.65 ±0.05 Seating plane C 0.10 C Solder ball material: 96.5% Sn, 3% Ag, 0.5% CU Solder mask defined ball pads: Ø0.40 Substrate material: Plastic laminate Mold compound: Epoxy novolac 6.40 54X Ø0.45 ±0.05 Solder ball diameter refers to post-reflow condition. The pre-reflow diameter is 0.42. 0.80 TYP Ball A1 ID Ball A1 ID Ball A1 4.00 ±0.05 Ball A9 6.40 CL 8.00 ±0.10 3.20 ±0.05 0.80 TYP CL 3.20 ±0.05 4.00 ±0.05 1.00 MAX 8.00 ±0.10 Notes: 1. All dimensions are in millimeters. ® 8000 S. Federal Way, P.O. Box 6, Boise, ID 83707-0006, Tel: 208-368-3900 [email protected] www.micron.com Customer Comment Line: 800-932-4992 Micron, the M logo, and the Micron logo are trademarks of Micron Technology, Inc. All other trademarks are the property of their respective owners. This data sheet contains minimum and maximum limits specified over the complete power supply and temperature range for production devices. Although considered final, these specifications are subject to change, as further product development and data characterization sometimes occur. PDF: 09005aef8237ed98/Source: 09005aef8237ed68 64mb_x16_Mobile SDRAM_Y24L_2.fm - Rev. C 10/07 EN 62 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2006 Micron Technology, Inc. All rights reserved.