MCC MUR3040WT

MCC
omponents
21201 Itasca Street Chatsworth
!"#
$
% !"#
Features
•
•
•
•
30 Amp
Super Fast Recovery
Rectifier
200 to 600 Volts
High Surge Capability
Low Forward Voltage Drop
High Current Capability
Super Fast Switching Speed For High Efficiency
Maximum Ratings
•
•
MUR3005WT
THRU
MUR3060WT
TO-247
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
MCC
Part Number
MUR3005WT
MUR3010WT
MUR3020WT
MUR3040WT
MUR3060WT
Maximum
Recurrent
Peak Reverse
Voltage
50V
100V
200V
400V
600V
Maximum
RMS
Voltage
35V
70V
140V
280V
420V
Maximum DC
Blocking
Voltage
50V
100V
200V
400V
600V
E
C
B
Q
U
4
L
A
R
1
3
2
P
K
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
IF(AV)
30 A
TC = 100°C
Current
Peak Forward Surge
IFSM
300A
8.3ms, half sine
Current
Maximum
Instantaneous
Forward Voltage
1.05V
IFM = 15.0A;
MUR3005WT-3020WT
VF
1.30V
T C = 25°C
MUR3040WT
1.70V
MUR3060WT
Maximum DC
10µA
TC = 25°C
Reverse Current At
IR
500µA
TC = 125°C
Rated DC Blocking
Voltage
Maximum Reverse
Recovery Time
MUR3005WT-3040WT
Trr
50ns
I F=0.5A, IR=1.0A,
MUR3060WT
80ns
I rr=0.25A
*Pulse Test: Pulse Width 300µsec, Duty Cycle 1%
H
F
J
V
D
G
PIN 1.
PIN 2.
PIN 3.
PIN 4.
ANODE
CATHODE
ANODE
CATHODE
DIMENSIONS
DIM
A
B
C
D
E
F
G
H
J
K
L
P
Q
R
U
V
INCHES
MIN
.803
.608
.185
.043
.059
.071
.215
.101
.019
.613
.286
.122
.138
.130
.209
.120
www.mccsemi.com
MAX
.823
.628
.205
.051
.064
.086
BSC
.130
.027
.633
.295
.133
.145
.150
BSC
.134
MM
MIN
20.40
15.44
4.70
1.09
1.50
1.80
5.45
2.56
0.48
15.57
7.26
3.10
3.50
3.30
5.30
3.05
MAX
20.90
15.95
5.21
1.30
1.63
2.18
BSC
2.87
0.68
16.08
7.50
3.38
3.70
3.80
BSC
3.40
NOTE
∅
MCC
MUR3005WT thru MUR3060WT
Figure 1
Typical Forward Characteristics @ TJ = 25 °C
2000
MUR3005WT-3020WT
MUR3040WT
MUR3060WT
1000
600
Figure 2
Typical Forward Characteristics @ TJ = 100°C
2000
MUR3005WT-3020WT
MUR3040
MUR3060
1000
600
400
400
200
200
25°C
Amps 100
Amps 100
60
60
40
40
20
20
10
10
6
6
4
4
2
2
1
0.8
1.0
1.8
1.2
1.4
1.6
Volts
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
1
100°C
0.8
1.0
1.8
1.2
1.4
1.6
Volts
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 3
Forward Derating Curve
60
50
40
30
Amps
20
10
0
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
130
140
150
160
170
180
°C
Average Forward Rectified Current Per Leg - Amperes versus
Case Temperature - °C
www.mccsemi.com
MCC
MUR3005WT thru MUR3060WT
Figure 4
Typical Reverse Characteristics
Figure 5
Peak Forward Surge Current
600
100
60
40
500
20
400
TJ =100°C
10
300
6
Amps
200
4
100
2
0
µAmps 1
1
2
4
6 8 10 20
40
60 80100
.6
Cycles
.4
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
.2
TJ =25°C
.1
.06
.04
.02
.01
20
40
60
80
100
120
140
Volts
Instantaneous Reverse Leakage Current - MicroAmperes
versus
Percent
FigureOf
7 Rated Peak Reverse Voltage - Volts
Reverse Recovery Time Characteristic And Test Circuit Diagram
50Ω
10Ω
trr
+0.5A
0
Pulse
Generator
Note 2
25Vdc
1Ω
Notes:
1. Rise Time = 7ns max.
Input impedance = 1 megohm, 22pF
2. Rise Time = 10ns max.
Source impedance = 50 ohms
3. Resistors are non-inductive
Oscilloscope
Note 1
-0.25
-1.0
1cm
Set Time Base for 20/100ns/cm