IRF MURB1020CT-1PBF

Bulletin PD-21081 08/05
MURB1020CTPbF
MURB1020CT-1PbF
Ultrafast Rectifier
Features
•
•
•
•
•
trr = 25ns
IF(AV) = 10Amp
VR = 200V
Ultrafast Recovery Time
Low Forward Voltage Drop
Low Leakage Current
175°C Operating Junction Temperature
Lead-Free ("PbF" suffix)
Description/ Applications
International Rectifier's MUR.. series are the state of the art Ultra fast recovery rectifiers specifically designed with
optimized performance of forward voltage drop and ultra fast recovery time.
The planar structure and the platinum doped life time control, guarantee the best overall performance, ruggedness
and reliability characteristics.
These devices are intended for use in the output rectification stage of SMPS, UPS, DC-DC converters as well as
free-wheeling diode in low voltage inverters and chopper motor drives.
Their extremely optimized stored charge and low recovery current minimize the switching losses and reduce over
dissipation in the switching element and snubbers.
Absolute Maximum Ratings
Parameters
Max
VRRM
Peak Repetitive Peak Reverse Voltage
IF(AV)
Average Rectified Forward Current
Units
200
V
5
A
Per Leg
Total Device, (Rated VR ), TC = 149°C
Total Device
10
IFSM
Non Repetitive Peak Surge Current
Per Leg
50
IFM
Peak Repetitive Forward Current
Per Leg
10
(Rated VR , Square wave, 20 KHz), TC = 149°C
TJ, TSTG
Operating Junction and Storage Temperatures
- 65 to 175
°C
Case Styles
MURB1020CTPbF
MURB1020CT-1PbF
BASE
COMMON
CATHODE
BASE
COMMON
CATHODE
2
1
2
2
3
ANODE COMMON ANODE
CATHODE
1
2
D2PAK
www.irf.com
1
2
3
ANODE COMMON ANODE
CATHODE
1
2
TO-262
1
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
Electrical Characteristics @ TJ = 25°C (unless otherwise specified)
Parameters
Min Typ Max Units Test Conditions
VBR, Vr
Breakdown Voltage,
Blocking Voltage
200
VF
Forward Voltage
-
-
V
IR = 100µA
-
0.87 0.99
V
IF = 5A, TJ = 125°C
-
1.02 1.20
V
IF = 10A, TJ = 125°C
-
1.12 1.25
V
IF = 10A, TJ = 25°C
VR = V R Rated
IR
Reverse Leakage Current
-
-
10
µA
CT
Junction Capacitance
-
-
250
µA
TJ = 150°C, VR = V R Rated
-
8
-
pF
VR = 200V
LS
Series Inductance
-
8.0
-
nH
Measured lead to lead 5mm
from package body
.
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
Parameters
trr
Min Typ Max Units Test Conditions
Reverse Recovery Time
-
-
35
-
-
25
-
24
-
ns
IF = 0.5A, IR = 1.0A, IREC = 0.25A
35
Peak Recovery Current
IRRM
Qrr
Reverse Recovery Charge
-
3.3
-
-
5.0
-
-
33
-
-
76
-
IF = 1.0A, diF/dt = 50A/µs, VR = 30V
A
TJ = 25°C
IF = 5A
TJ = 125°C
VR = 160V
diF /dt = 200A/µs
TJ = 25°C
TJ = 125°C
nC
TJ = 25°C
TJ = 125°C
Thermal - Mechanical Characteristics
Min
Typ
Max
TJ
Parameters
Max. Junction Temperature Range
- 65
-
175
TStg
Max. Storage Temperature Range
- 65
-
175
RthJC
Thermal Resistance, Junction to Case
Per Leg
-
-
5
Thermal Resistance, Junction to Ambient Per Leg
-
-
50
Thermal Resistance, Case to Heatsink
-
0.5
-
Weight
-
2.0
-
g
-
0.07
-
(oz)
Kg-cm
RthJA
RthCS
Wt
c
Mounting Torque
Marking Device
6.0
-
12
5.0
-
10
Units
°C
°C/W
lbf.in
2
MURB1020CT
Case style D Pak
MURB1020CT-1
Case style TO-262
c Mounting Surface, Flat, Smooth and Greased
2
www.irf.com
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
100
Reverse Current - I R (µA)
10
TJ = 175˚C
150˚C
10
125˚C
1
100˚C
0.1
0.01
25˚C
0.001
0.0001
0
T = 175˚C
J
T = 125˚C
J
T = 25˚C
J
80
120
160
200
100
1
0.1
0.2
40
Reverse Voltage - VR (V)
Fig. 2 - Typical Values Of Reverse Current
Vs. Reverse Voltage
Junction Capacitance - C T (pF)
Instantaneous Forward Current - I F (A)
100
T = 25˚C
J
10
1
0.4
0.6
0.8
1
1.2
1.4
1.6
1
Forward Voltage Drop - VFM (V)
Fig. 1 - Typical Forward Voltage Drop Characteristics
10
100
1000
Reverse Voltage - VR (V)
Fig. 3 - Typical Junction Capacitance
Vs. Reverse Voltage
Thermal Impedance Z
thJC
(°C/W)
10
1
D = 0.50
D = 0.20
D = 0.10
D = 0.05
D = 0.02
D = 0.01
PDM
t1
t2
0.1
Notes:
Single Pulse
(Thermal Resistance)
0.01
0.00001
0.0001
0.001
1. Duty factor D = t1/ t2
2. Peak Tj = Pdm x ZthJC + Tc
0.01
0.1
1
t1, Rectangular Pulse Duration (Seconds)
Fig. 4 - Max. Thermal Impedance Z thJC Characteristics
www.irf.com
3
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
7
Average Power Loss ( Watts )
Allowable Case Temperature (°C)
180
170
DC
160
150 Square wave (D = 0.50)
Rated Vr applied
140
see note (2)
130
RMS Limit
6
5
4
D = 0.01
D = 0.02
D = 0.05
D = 0.1
D = 0.2
D = 0.5
DC
3
2
1
0
0
2
4
6
8
0
Average Forward Current - IF(AV) (A)
1
2
3
4
5
6
7
8
Average Forward Current - IF(AV) (A)
Fig. 5 - Max. Allowable Case Temperature
Vs. Average Forward Current
Fig. 6 - Forward Power Loss Characteristics
160
50
I F = 10 A
IF = 5 A
VR = 160V
TJ = 125˚C
TJ = 25˚C
140
120
40
IF = 10 A
IF = 5 A
Qrr ( nC )
trr ( ns )
100
30
80
60
40
20
20
VR = 160V
TJ = 125˚C
TJ = 25˚C
10
100
1000
di F /dt (A/µs )
Fig. 7 - Typical Reverse Recovery vs. di F /dt
0
100
1000
di F /dt (A/µs )
Fig. 8 - Typical Stored Charge vs. di F /dt
(2) Formula used: TC = T J - (Pd + PdREV) x RthJC ;
Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6);
PdREV = Inverse Power Loss = V R1 x IR (1 - D); IR @ V R1 = rated VR
4
www.irf.com
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
Reverse Recovery Circuit
VR = 200V
0.01 Ω
L = 70µH
D.U.T.
di F /dt
dif/dt
ADJUST
D
IRFP250
G
S
Fig. 9- Reverse Recovery Parameter Test Circuit
3
t rr
IF
tb
ta
0
2
Q rr
I RRM
4
0.5 I RRM
di(rec)M/dt
5
0.75 I RRM
1
/dt
di fF/dt
1. diF/dt - Rate of change of current through zero
crossing
2. IRRM - Peak reverse recovery current
3. trr - Reverse recovery time measured from zero
crossing point of negative going IF to point where
a line passing through 0.75 IRRM and 0.50 I RRM
extrapolated to zero current
4. Qrr - Area under curve defined by t rr
and IRRM
t rr x I RRM
Q rr =
2
5. di (rec) M / dt - Peak rate of change of
current during t b portion of t rr
Fig. 10 - Reverse Recovery Waveform and Definitions
www.irf.com
5
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
Outlines Table
BASE
COMMON
CATHODE
2
1
2
3
ANODE COMMON ANODE
CATHODE
1
2
Conform to JEDEC outline D2Pak (SMD-220)
Dimensions in millimeters and (inches)
Modified JEDEC outline TO-262
Dimensions in millimeters and (inches)
BASE
COMMON
CATHODE
2
1
2
3
ANODE COMMON ANODE
CATHODE
1
2
6
NC
www.irf.com
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
Part Marking Information
D2PAK
THIS IS A MURB1020CT
LOT CODE 8024
ASSEMBLED ON WW 02, 2000
INTERNATIONAL
RECTIFIER
LOGO
PART NUMBER
MURB1020CT
DATE CODE
YEAR 0 = 2000
WEEK 02
P = LEAD-FREE
ASSEMBLY
LOT CODE
TO-262
THIS IS A MURB1020CT-1
LOT CODE 8024
ASSEMBLED ON WW 02, 2000
INTERNATIONAL
RECTIFIER
LOGO
MURB1020CT-1
DATE CODE
ASSEMBLY
LOT CODE
www.irf.com
PART NUMBER
YEAR 0 = 2000
WEEK 02
P = LEAD-FREE
7
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
Tape & Reel Information
TRR
1.60 (0.063)
1.50 (0.059)
4.10 (0.161)
3.90 (0.153)
1.60 (0.063)
1.50 (0.059)
DIA.
0.368 (0.0145)
0.342 (0.0135)
FEED DIRECTION
1.85 (0.073)
11.60 (0.457)
1.65 (0.065)
11.40 (0.449)
15.42 (0.609)
15.22 (0.601)
TRL
1.75 (0.069)
10.90 (0.429)
10.70 (0.421)
1.25 (0.049)
24.30 (0.957)
23.90 (0.941)
DIA.
16.10 (0.634)
4.72 (0.186)
4.52 (0.178)
15.90 (0.626)
FEED DIRECTION
13.50 (0.532)
12.80 (0.504)
DIA.
26.40 (1.039)
24.40 (0.961)
SMD-220 Tape & Reel
When ordering, indicate the part
number, part orientation, and the
quantity. Quantities are in multiples
360 (14.173)
DIA. MAX.
60 (2.362)
of 800 pieces per reel for both
TRL and T RR.
D IA . MIN.
Dimensions in millimeters and (inches)
8
www.irf.com
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
Ordering Information Table
Device Code
MUR
B
10
20
CT
-1
1
2
3
4
5
6
TRL PbF
7
8
1
-
Ultrafast MUR Series
2
-
B
3
-
Current Rating (10 = 10A)
4
-
Voltage Rating (20 = 200V)
5
-
CT
= Center Tap (Dual) TO-220 /D2PAK/ TO-262
6
-
-1
= TO-262
7
-
y none = Tube (50 pieces)
= D2Pak/ TO-262
y TRL = Tape & Reel (Left Oriented, for D2PAk package)
6
y TRR = Tape & Reel (Right Oriented, for D 2PAk package)
8
-
y none = Standard Production
y PbF = Lead-Free
Data and specifications subject to change without notice.
This product has been designed and qualified for Industrial Level and Lead-Free.
Qualification Standards can be found on IR's Web site.
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 08/05
www.irf.com
9