MEANWELL MWP-602

MEAN WELL
MWP-602(A)
(53020)
MWP-606(A)
SWITCHING POWER SUPPLY
ISO-9001 CERTIFIED MANUFACTURER
.LOW COST, HIGH RELIABILITY
.COMPACT SIZE, LIGHT WEIGHT
.105ºC OUTPUT CAPACITOR
.100% FULL LOAD BURN-IN TEST
.INTERNATIONAL AC INPUT RANGE
.OUTPUT VOLTAGE CORRECTION LED
.BUILT IN EMI FILTER, LOW RIPPLE NOISE
.HIGH EFFICIENCY, LOW WORKING TEMPERATURE
.SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT
.SHORT CIRCUIT, OVERLOAD PROTECTED
MWP-602/MWP-602A/(53020)
MODEL
SPECIFICATION
MWP-606/MWP-606A
CH1
CH2
CH3
CH1
CH2
CH3
5V
12V
-5V
5V
12V
-5V
OUTPUT V. TOLERANCE
±2%
±8%
±10%
±2%
±8%
±10%
OUTPUT RATED CURRENT
15A
2A
1A
15A
2A
1A
DC OUTPUT VOLTAGE
OUTPUT CURRENT RANGE
3-15A
0.2-3A
0.1-1A
3-15A
0.2-4A
0.1-1A
50mVp-p
120mVp-p
60mVp-p
50mVp-p
120mVp-p
60mVp-p
LINE REGULATION
±0.5%
±1%
±1%
±0.5%
±1%
±1%
LOAD REGULATION
±1%
±6%
±8%
±1%
±6%
±8%
RIPPLE & NOISE
DC OUTPUT POWER
104W
104W
EFFICIENCY
75%
75%
CH1:4.7~5.8Vref.
CH1:4.75~5.5Vref.
DC VOLTAGE ADJ.
INPUT VOLTAGE RANGE
88~132VAC / 176~264VAC SELECTED BY SWITCH 47~63Hz; 240~370VDC
AC CURRENT
2.6A/115V 1.3A/230V
INRUSH CURRENT
COLD START 20A/115V 40A/230V
LEAKAGE CURRENT
<0.5mA/240VAC
OVERLOAD PROTECTION
105%~150% TYPE:FOLDBACK CURRENT SHUTDOWN RESET:RE-POWER ON
OVER VOLTAGE PROTECTION
----------
OPERATING DISPLAY
602A, 606A DOUBLE COLOR LED CORRECT RANGE:GREEN(5~5.4Vref.) WRONG RANGE:RED
TEMP. COEFFICIENT
±0.05% / ºC (0~50ºC) ON +5V OUTPUT
SETUP, RISE, HOLD UP TIME
200ms, 50ms, 16ms
VIBRATION
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES
WITHSTAND VOLTAGE
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
WORKING TEMP., HUMIDITY
-10ºC~+60ºC(REFER TO OUTPUT DERATING CURVE), 20%~90% RH
STORAGE TEMP., HUMIDITY
-20ºC~+85ºC, 10%~95% RH
DIMENSION
180*110*50mm CASE:602 203*115*50mm WITH TERMINAL & FIXED IRON
WEIGHT
0.9Kgs
SAFETY STANDARDS
MEET UL1012 REQUIREMENT (NOT APPLY FOR
THE MARK)
UL1950, TUV EN60950 APPROVED
EMC STANDARDS
---------
CISPR22 (EN55022) CLASS B, IEC801-2,3,4,
IEC555-2 VERIFICATION
NOTE :
1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25ºC 70% RH. AMBIENT.
2.TOLERANCE GINCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION.
3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR.
4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD.
5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD.
6.EACH OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT TOTAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER.
JUN.09.98