[ UTZ-SC0134_3 ] 2008/02/22 Violet Laser Diode NDV4313 Outline Dimension Features • Optical Output Power: CW120mW • Peak Wavelength: 405nm • Can Type:φ5.6 with Photo Diode Unit (mm) 0 + .03 0 - ( 1.6 ) Φ Φ 5.6 (90° ) Absolute Maximum Ratings (Tc=25°C) Φ 3.55±0.1 0.25±0.03 Z+ Φ 4.2±0.2 Glass Thickness mW V V °C °C 1.0±0.1 Emitting Point Reference Plane (1.3) Po Vr (LD) Vr (PD) Tstg Tc Unit 0.4±0.1 Optical Output Power LD Reverse Voltage PD Reverse Voltage Storage Temperature Operating Case Temperature Absolute Maximum Ratings 140 5 20 -40 ~ 85 -10 ~ 70 1.2±0.1 2.3±0.2 Symbol 6.5±1.0 Item Emitting Point (0.4) 3×Φ 0.45±0.1 Initial Electrical/Optical Characteristics Item Condition Optical Output Power Peak Wavelength* Threshold Current Operating Current Slope Efficiency Operating Voltage CW Po=120mW CW Po=120mW CW Po=120mW FWHM Beam Divergence Po=120mW Emission Point Accuracy Angle Po=120mW Symbol Po λp Ith Iop η Vop θ// θ⊥ Δθ// Δθ⊥ Im (Tc=25°C) Min 400 1.2 7.0 15.0 -2.0 -2.5 0.2 Typ. 405 35 120 1.4 4.8 9.0 19.5 0.4 Max 120 410 50 150 1.9 5.5 12.0 23.0 2.0 2.5 0.7 3 Unit mW nm mA mA W/A V deg. deg. deg. deg. mA X+ 1 2 Φ 2.0±0.2 Y+ Pin Connection This internal photodiode are solely Nichia's internal evaluation purpose only, and Nichia gives no warranty to Monitor Current. Monitor Current** Po=120mW * Measuring specifications. ** Monitor Current is short time power reference purpose only. Not guaranteed for accuracy. All figures in this specification are measured by Nichia's method and may contain measurement deviations. The above specifications are for reference purpose only and subjected to change without prior notice. Safety of Laser light Laser Light can damege the human eyes and skin. Do not expose the eye or skin to any laser light directly and/or through optical lens. When handling the LDs, wear appropriate safety glasses to prevent laser light, even any reflections from entering to the eye. Focused laser beam through optical instruments will increase the chance of eye hazard. These LDs are classified in Class 4 of IEC60825-1 and 21 CFR Part 1040.10 Safety Standards. It is absolutely necessary to take overall safety measures against User's modules, equipment and systems into which Nichia LDs are incorporated and/or integrated. NICHIA CORPORATION http://www.nichia.co.jp HEAD OFFICE P.O.BOX 6 ANAN, TOKUSHIMA-KEN 774-8601, JAPAN PHONE: +81-884-22-2311 FAX: +81-884-21-0148 CONTACT TOKYO SALES DEPARTMENT OPTOELECTRONICS PRODUCTS DIV. 13F TAMACHI CENTER BUILDING, 34-7, SHIBA 5-CHOME, MINATO-KU, TOKYO 108-0014, JAPAN PHONE: +81-3-3456-3108 FAX: +81-3-5440-7330 -1- [ UTZ-SC0134_3 ] 2008/02/22 Typical Characteristics -2- [ UTZ-SC0134_3 ] 2008/02/22 Cautions (1) Operating method The LD shall change its forward voltage requirement and optical output power according to temperature change. Also, the LD will require more operation current to maintain same output power as it degrades. In order to maintain output power, use of APC (Automatic Power Control) is recommended, which use monitor feedback to adjust the operation current. Confirm that electrical spike current generated by switching on and off does not exceed the maximum operating current level specified herein above as absolute max rating. Also, employ appropriate countermeasures to reduce chattering and/or overshooting in the Circuit. (2) Static Electricity Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is recommended to use a wrist strap or anti-electrostatic glove when handling the Product. (3) Absolute Maximum Rating Active layer of LDs shall have high current density and generate high electric field during its operation. prevent excessive damage, the LD must be operated strictly below Absolute Max Rating. In order to (4) Others Nichia LDs described in this brochure are intended to be used for ordinary electronic equipment (such as office equipment, communications equipment, measurement instruments and household appliances). Consult Nichia’s sales staff in advance for information on the applications in which exceptional quality and reliability are required, particularly when the failure or malfunction of the LDs may directly jeopardize life or health (such as for airplanes, aerospace, submersible repeaters, nuclear reactor control systems, automobiles, traffic control equipment, life support systems and safety devices). The Purchaser must acknowledge that any LD can be failed statically and must design its equipments fail safe design. Prior to use of the LD, please confirm that the LD, as described in Nichia’s specifications, meets the life expectancy needs of, and provides the features required by the Circuit and any related modules, equipment and/or systems. Nichia prohibit Purchaser from reverse engineering, disassembling, or taking any other steps to derive the structure or design of the LD. The appearance and specifications of the product may be modified for improvement without notice. The formal specifications must be exchanged and signed by both parties before large volume purchase begins. No unauthorized transmission or reproduction of this document, either in whole or in part, is permitted. -3-