NICHIA NDV4313

[ UTZ-SC0134_3 ]
2008/02/22
Violet Laser Diode
NDV4313
Outline Dimension
Features
• Optical Output Power: CW120mW
• Peak Wavelength: 405nm
• Can Type:φ5.6 with Photo Diode
Unit (mm)
0
+ .03
0
-
(
1.6
)
Φ
Φ
5.6
(90°
)
Absolute Maximum Ratings
(Tc=25°C)
Φ 3.55±0.1
0.25±0.03
Z+
Φ 4.2±0.2
Glass Thickness
mW
V
V
°C
°C
1.0±0.1
Emitting Point
Reference Plane
(1.3)
Po
Vr (LD)
Vr (PD)
Tstg
Tc
Unit
0.4±0.1
Optical Output Power
LD Reverse Voltage
PD Reverse Voltage
Storage Temperature
Operating Case Temperature
Absolute Maximum
Ratings
140
5
20
-40 ~ 85
-10 ~ 70
1.2±0.1
2.3±0.2
Symbol
6.5±1.0
Item
Emitting Point
(0.4)
3×Φ 0.45±0.1
Initial Electrical/Optical Characteristics
Item
Condition
Optical Output Power
Peak Wavelength*
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
CW
Po=120mW
CW
Po=120mW
CW
Po=120mW
FWHM Beam
Divergence
Po=120mW
Emission Point
Accuracy
Angle
Po=120mW
Symbol
Po
λp
Ith
Iop
η
Vop
θ//
θ⊥
Δθ//
Δθ⊥
Im
(Tc=25°C)
Min
400
1.2
7.0
15.0
-2.0
-2.5
0.2
Typ.
405
35
120
1.4
4.8
9.0
19.5
0.4
Max
120
410
50
150
1.9
5.5
12.0
23.0
2.0
2.5
0.7
3
Unit
mW
nm
mA
mA
W/A
V
deg.
deg.
deg.
deg.
mA
X+
1
2
Φ 2.0±0.2
Y+
Pin Connection
This internal photodiode are solely
Nichia's internal evaluation purpose only,
and Nichia gives no warranty to Monitor
Current.
Monitor Current**
Po=120mW
* Measuring specifications.
** Monitor Current is short time power reference purpose only.
Not guaranteed for accuracy.
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
The above specifications are for reference purpose only and subjected to change without prior notice.
Safety of Laser light
Laser Light can damege the human eyes and skin. Do not expose the eye or skin to any
laser light directly and/or through optical lens. When handling the LDs, wear appropriate
safety glasses to prevent laser light, even any reflections from entering to the eye. Focused
laser beam through optical instruments will increase the chance of eye hazard.
These LDs are classified in Class 4 of IEC60825-1 and 21 CFR Part 1040.10 Safety
Standards. It is absolutely necessary to take overall safety measures against User's
modules, equipment and systems into which Nichia LDs are incorporated and/or integrated.
NICHIA CORPORATION
http://www.nichia.co.jp
HEAD OFFICE
P.O.BOX 6 ANAN, TOKUSHIMA-KEN 774-8601, JAPAN
PHONE: +81-884-22-2311
FAX: +81-884-21-0148
CONTACT
TOKYO SALES DEPARTMENT OPTOELECTRONICS PRODUCTS DIV.
13F TAMACHI CENTER BUILDING, 34-7, SHIBA 5-CHOME, MINATO-KU,
TOKYO 108-0014, JAPAN
PHONE: +81-3-3456-3108
FAX: +81-3-5440-7330
-1-
[ UTZ-SC0134_3 ]
2008/02/22
Typical Characteristics
-2-
[ UTZ-SC0134_3 ]
2008/02/22
Cautions
(1) Operating method
The LD shall change its forward voltage requirement and optical output power according to temperature change. Also, the
LD will require more operation current to maintain same output power as it degrades. In order to maintain output power, use
of APC (Automatic Power Control) is recommended, which use monitor feedback to adjust the operation current.
Confirm that electrical spike current generated by switching on and off does not exceed the maximum operating current
level specified herein above as absolute max rating. Also, employ appropriate countermeasures to reduce chattering and/or
overshooting in the Circuit.
(2) Static Electricity
Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is recommended to use a wrist
strap or anti-electrostatic glove when handling the Product.
(3) Absolute Maximum Rating
Active layer of LDs shall have high current density and generate high electric field during its operation.
prevent excessive damage, the LD must be operated strictly below Absolute Max Rating.
In order to
(4) Others
Nichia LDs described in this brochure are intended to be used for ordinary electronic equipment (such as office equipment,
communications equipment, measurement instruments and household appliances). Consult Nichia’s sales staff in advance
for information on the applications in which exceptional quality and reliability are required, particularly when the failure or
malfunction of the LDs may directly jeopardize life or health (such as for airplanes, aerospace, submersible repeaters,
nuclear reactor control systems, automobiles, traffic control equipment, life support systems and safety devices).
The Purchaser must acknowledge that any LD can be failed statically and must design its equipments fail safe design. Prior
to use of the LD, please confirm that the LD, as described in Nichia’s specifications, meets the life expectancy needs of, and
provides the features required by the Circuit and any related modules, equipment and/or systems.
Nichia prohibit Purchaser from reverse engineering, disassembling, or taking any other steps to derive the structure or
design of the LD.
The appearance and specifications of the product may be modified for improvement without notice. The formal
specifications must be exchanged and signed by both parties before large volume purchase begins.
No unauthorized transmission or reproduction of this document, either in whole or in part, is permitted.
-3-