14-Bit, 200 kS/s Data Acquisition with PDAs NI CF-6004 • Ultraportable DAQ device for CompactFlash • 4 channels of 14-bit analog input • Up to 200 kS/s single-channel sampling • Up to 132 kS/s multichannel (aggregate) sampling • 4 digital I/O lines (3.3 V) • Programmable with LabVIEW PDA software Product CF-6004 1SE Bus CompactFlash = Single ended 2Single Analog Inputs1 4 SE Input Resolution (bits) 14 Operating Systems NEW • PocketPC/Windows Mobile • Windows CE1 1Only on a limited number of devices – visit ni.com for more information. Required Software • LabVIEW PDA for PocketPC Driver Software (Included) • NI-DAQmx Base Max Sampling Rate (kS/s)2 200 Max Input Range (V) ±5 Digital I/O 4 channel rate. See detailed specifications for multichannel rate. Hardware Description Measuring less than 16 cm2, slightly larger than a standard postage stamp, the National Instruments CF-6004 is a tiny, yet powerful platform for handheld measurements. With 14-bit resolution and up to 132 kS/s aggregate sampling on four analog input channels, the NI CF-6004 packs full measurement functionality into a Type II CompactFlash slot, available on many PDAs. The NI CF-6004 is ideal for many portable applications, from consolidation of multiple handheld instruments to custom handheld measurement, analysis, and communication. Recommended Accessories Three connectivity options are available for use with the NI CF-6004. You can use the SH-15-15-B to connect directly to signals or your own custom connector, or you can use the SH-15-15 to connect to one of two connector blocks. NI CF-6004 NI SH-15-15-B Shielded Cable with Bare Wires NI SH-15-15 Shielded Cable with D-Sub Connector NI SCB-15 Shielded Compact Connector Block NI CB-15 DIN-Rail-Mountable Connector Block Figure 1. Connectivity Options Software Description The CF-6004 ships with NI-DAQmx Base driver software, a multiplatform driver with a subset of the NI-DAQmx programming interface. Use it to develop customized handheld DAQ applications with the NI LabVIEW PDA module for PocketPC. Common Applications The CF-6004 in a PDA is ideal for a number of applications where economy, small size, and portability are essential, such as: • Biomedical/wearable computing • Field monitoring/diagnostics • Portable data logging and analysis Information for OEM Customers For information on special configurations and pricing, please visit ni.com/oem or contact your local NI sales representative. 14-Bit, 200 kS/s Data Acquisition with PDAs Ordering Information NI CF-6004 ....................................................................779174-01 Includes NI-DAQmx Base software Accessories Terminal Blocks NI CB-15 ..................................................................779198-01 NI SCB-15 ................................................................779197-01 Cables NI SH-15-15 ..........................................................191067-0R5 NI SH-15-15-B ......................................................191070-0R5 BUY NOW! For complete product specifications, pricing, and accessory information, call (800) 813-3693 (U.S. only) or go to ni.com/daq. Specifications Typical for 25 ˚C unless otherwise specified. Physical Characteristics If you need to clean the module, wipe it with a dry towel. Analog Input Number of channels......................................... ADC type .......................................................... ADC resolution ................................................. DNL................................................................... INL ................................................................... Sampling rate (may be system dependent) Single-channel, finite acquisition up to 8 kS, raw or calibrated.............. up to 1 MS, raw data ......................... Multi-channel, finite acquisition up to 8 kS total, raw or calibrated ..... up to 1 MS total, raw data................. Continuous acquisition calibrated data, monitoring ................ calibrated data, graphing ................... Minimum hardware-timed sample rate .... Minimum effective software-timed sample rate ......................................... Timing accuracy......................................... Timing resolution ....................................... Settling time..................................................... Input coupling................................................... Input range ....................................................... Maximum working voltage .............................. Input Impedance............................................... Input bias current ............................................. Crosstalk (at 1 kHz) Adjacent channels ..................................... Nonadjacent channels............................... Small signal bandwidth -3 dB .......................................................... System noise .................................................... Input FIFO size .................................................. Data transfers .................................................. Overvoltage protection..................................... Input current during overvoltage condition ..... Accuracy over the operating range.................. 4 single-ended Successive approximation 14 bits No missing codes ±1 LSB Dimensions....................................................... Type II CompactFlash Card Weight.............................................................. 9 g (0.3 oz) I/O Connectors ................................................. 15-pin Bus Interface CompactFlash Power Requirement 200 kS/s 200 kS/s +3.3 V from PDA host....................................... 2 mA idle maximum 50 mA typical (continuous acquisition) 68 mA maximum all outputs loaded 132 kS/s, aggregate 132 kS/s, aggregate Calibration Recommended warm-up time.......................... 15 minutes Calibration interval........................................... 1 year 18 kS/s, typical 1 kS/s, typical 195 S/s Environment The CF-6004 device is intended for indoor use only. 0 S/s 50 ppm 78.125 ns 20 ppm at 7.6 µs, 0.1Ω source impedance DC ±5 V ±5 V 100 MΩ in parallel with 20 pF 75 pA Operating Environment Ambient temperature ................................ 0 to 40 ˚C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.) Relative humidity....................................... 10 to 90%, noncondensing (Tested in accordance with IEC-60068-2-56.) Storage Environment Ambient temperature ................................ -20 to 70 ˚C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.) Relative humidity....................................... 5 to 90%, noncondensing (Tested in accordance with IEC-60068-2-56.) Maximum altitude ............................................ 2,000 m (at 25 ˚C ambient temperature) Pollution degree ............................................... 2 -104 dB typical -104 dB typical 497 kHz 0.75 LSBrms 8,192 samples Programmed I/O ±15 V 15.3 mA ±3.1 mV typical ±21 mV maximum Certifications and Compliances The CF-6004 is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1 • CAN/CSA C22.2 No. 61010-1 Note: For UL and other safety certifications, refer to the product label, or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Digital I/O Number of channels......................................... Direction control............................................... Output driver type ............................................ Compatibility .................................................... Power-on state ................................................. Data transfers .................................................. Absolute maximum voltage range ................... 4 (PFI.<0..3>) Each channel individually programmable as input or output Push-pull 3.3 V LVCMOS and LVTTL Input (high impedance) Programmed I/O -0.5 V to 4 V Digital logic levels Level Input low voltage Input high voltage Input leakage current Output low voltage (I = 2 mA) Output high voltage (I = 2 mA) Input current (0 < Vin < 3.3 V) Minimum -0.3 2 -1 – 2.5 -1 Maximum 0.8 3.9 1 0.8 – 1 Units V V µA V V µA Power Available at I/O Connector Output (10 mA maximum) ................................ 3.3 V typical 2.97 V minimum 2 National Instruments • Tel: (800) 433-3488 • [email protected] • ni.com Voltages Connect only voltages that are within the absolution maximum limits of the connection point. See pertinent specification section for appropriate limits. Hazardous Locations The CF-6004 is not certified for use in hazardous locations. Electromagnetic Compatibility Emissions.......................................................... EN 55011 Class A at 10 m FCC Part 15A above 1 GHz Immunity........................................................... Industrial levels per EN 61326:1997 + A2:2001, Table 1 EMC/EMI .......................................................... CE, C-Tick, and FCC Part 15 (Class A) Compliant Note: For EMC compliance, operate this device with shielded cabling. CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: Low-Voltage Directive (safety)......................... 73/23/EEC Electromagnetic Compatibility Directive (EMC) ................................................ 89/336/EEC Note: Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. NI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Local Sales and Technical Support SERVICE NEEDS In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industryleading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. Hardware Services NI Factory Installation Services NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor. Professional Services Our Professional Services Team is comprised of NI applications engineers, NI Consulting Services, and a worldwide NI Alliance Partner Program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. Calibration Services NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. Repair and Extended Warranty We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. ni.com • (800) 433-3488 National Instruments • Tel: (512) 683-0100 • [email protected] © 2005 National Instruments Corporation. All rights reserved. LabVIEW, National Instruments Alliance Partner, ni.com, NI-DAQ, RTSI, and SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies. 2004_4599_301_101_D OEM Support