NICHIA NUU205E

Product Guide (UTZ-SC0293_0)
2011/10/11
LD Receptacle Module (Ultra Violet Type)
NUU205E
Engineering Sample
Specifications
• Optical Fiber Output Power: 150mW
• Ferrule Type: SC
Absolute Maximum Ratings
Item
Symbol
Absolute Maximum Ratings
Unit
Optical Fiber Output Power*
Po
180
mW
Allowable Reverse Current
Ir(LD)
85
mA
PD Reverse Voltage
Vr(PD)
5
V
Storage Temperature
Tstg
-40 ~ 85
°C
Operating Case Temperature
Tc
20 ~ 30
°C
* Core Diameter=40µm, NA=0.20, Fiber Length=1.0m
Initial Electrical/Optical Characteristics
(Tc=25°C)
Item
Symbol
Test Condition
Min
Typ.
Max
Unit
Optical Fiber Output Power*
Peak Wavelength
Threshold Current*
Operating Current*
Slope Efficiency*
Operating Voltage*
Po
λp
Ith
Iop
η
Vop
CW
Po=150mW
CW
Po=150mW
CW
Po=150mW
370
0.6
-
375
200
390
0.9
4.5
150
380
260
480
1.7
5.0
mW
nm
mA
mA
W/A
V
Beam Divergence
Full Angle (1/e2)*
θ
Po=150mW
-
11
15
deg.
Monitor Current**
Im
Po=150mW
1
mA
* Core Diameter=40µm, NA=0.20, Fiber Length=1.0m
** Monitor Current is short time power reference purpose only. Not guaranteed for accuracy.
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
The above specifications are for reference purpose only and subjected to change without prior notice.
Outline Dimension
6.5±1.0
1
Φ2.0±0.2
LD
1
3
2
(Flange)
1. LD Anode
2. LD Cathode
3. PD Cathode
4. PD Anode
This model has a protection device built in as
a protection circuit against static electricity.
NICHIA CORPORATION
http://www.nichia.co.jp
4
3
2
7.0±0.2
NUU205E
3-Φ0.45±0.1
PD
7.6±0.2
Protection
Device
4.4±0.1
4
15.6Max
9.45±0.2
1.55±0.1
Pin Connection
11±0.1
000001
Φ1.8
7Max
8Max
0.2±0.15
Serial Number
Unit (mm)
HEADQUARTERS
491 Oka, Kaminaka-Cho, Anan-Shi, TOKUSHIMA 774-8601, JAPAN
PHONE: +81-884-22-2311
FAX: +81-884-21-0148
CONTACT
TOKYO SALES OFFICE
13F Tamachi Center Building 34-7, Shiba 5-Chome, Minato-ku, TOKYO 108-0014, JAPAN
PHONE: +81-3-3456-3108
FAX: +81-3-5440-7330
-1-
Product Guide (UTZ-SC0293_0)
2011/10/11
Cautions
(1) Safety of Laser light
Laser light can damage the human eyes and skin. Do not expose the eye or
skin to any laser light directly and/or through optical lens. When handling the LD
Receptacle Modules, wear appropriate safety glasses to prevent laser light, even
any reflections from entering to the eye. Focused laser beam through optical
instruments will increase the chance of eye hazard.
These LD Receptacle Modules are classified in Class 3b of the IEC60825-1 and
21 CFR Part 1040.10 Safety Standards. It is absolutely necessary to take
overall safety measures against User's modules, equipment and systems into
which Nichia LD Receptacle Modules are incorporated and/or integrated.
Ⅲ
(2) Operating method
The LD Receptacle Module shall change its forward voltage requirement and optical output power according to
temperature change. Also, the LD Receptacle Module will require more operation current to maintain same output
power as it degrades. In order to maintain output power, use of APC (Automatic Power Control) is recommended,
which use monitor feedback to adjust the operation current.
Confirm that electrical spike current generated by switching on and off does not exceed the maximum operating
current level specified herein above as absolute max rating. Also, employ appropriate countermeasures to reduce
chattering and/or overshooting in the Circuit.
(3) Static Electricity
Static electricity or electrical surges will reduce and degrade the reliability of the LD Receptacle Modules. It is
recommended to use a wrist strap or anti-electrostatic glove when handling the Product.
(4) Absolute Maximum Rating
Active layer of LD Receptacle Modules shall have high current density and generate high electric field during its
operation. In order to prevent excessive damage, the LD Receptacle Module must be operated strictly below Absolute
Max Rating.
(5) Others
Nichia LD Receptacle Modules described in this brochure are intended to be used for ordinary electronic equipment
(such as office equipment, communications equipment, measurement instruments and household appliances). Consult
Nichia’s sales staff in advance for information on the applications in which exceptional quality and reliability are
required, particularly when the failure or malfunction of the LD Receptacle Modules may directly jeopardize life or
health (such as for airplanes, aerospace, submersible repeaters, nuclear reactor control systems, automobiles, traffic
control equipment, life support systems and safety devices).
Nichia prohibit Purchaser from reverse engineering, disassembling, or taking any other steps to derive the structure or
design of the LD Receptacle Module.
The appearance and specifications of the product may be modified for improvement without notice. The formal
specifications must be exchanged and signed by both parties before large volume purchase begins.
-2-