OBD SERIES - DUAL OUTPUT, 25 WATT
DESCRIPTION
FEATURES
OBD dual output DC/DC converters provide up to 25
Watts of output power in an industry standard package
and footprint. These units feature excellent efficiency,
six-sided shielding, and fixed switching frequency. With
100°C case operation, the OBD units are especially suited
to telecom, networking, and industrial applications.
These units are 100% surface-mount construction and
fully compatible with production board washing
processes.
• Industry Standard
•
Package
•
• 48V Input
• Fixed-Frequency Design •
• 100°C Case Operation •
Trim and Enable Pins
Fixed Switching
Frequency
1500V Isolation
6-Sided Shielding
Efficiency vs. Load (24V Input)
90
EFFICIENCY %
85
TECHNICAL SPECIFICATIONS
80
EFF. OBD25YJJ
75
EFF. OBD25YHH
70
Input
Voltage Range
48 VDC Nominal
Reflected Ripple
Input Reverse Voltage Protection
65
34 - 75 VDC
25 mA
Shunt Diode
10
20
30
40
50
60
70
80
90
100
90
100
LOAD %
Output
±1%
0.2% Vout
0.5% Vout
10 % Iout Rated
25% Iout
4% Vout
500 µs
±10%
Hiccup
110 - 140%
115 - 140% Vout Nom.
Second Control Loop
Efficiency vs. Load (48V Input)
100
90
EFFICIENCY %
Setpoint Accuracy
Line Regulation Vin Min. - Vin Max., Iout Rated
Load Regulation Iout Min. - Iout Max., V in Nom.
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
Short Circuit / Overcurrent Protection
Current Limit Threshold Range, % of Iout Rated
OVP Trip Range
OVP and UVP Type
70
EFF. OBD025ZJJ
EFF. OBD025ZGG
60
EFF. OBD025ZHH
50
40
General
Turn-On Time: 24 & 48V Input
Remote Shutdown
Remote Shutdown Reference
Switching Frequency
Isolation
Input - Output
Input - Case (12 Vin and 24 Vin units)
Output - Case (48 Vin units)
Temperature Coefficient
Case Temperature
Operating Range (12V Input Max. Temp +85°C)
Storage Range
Vibration, 3 Axes, 5 Min. Each
MTBF† (Bellcore TR-NWT-000332)
Safety
Weight (Approx.)
80
10
10 ms
Positive
Vin Negative
400 kHz
1500 VDC
1050 VDC
500 VDC
0.03%/°C
-40 to +100°C
-40 to +125°C
5 g, 10 - 55 Hz
1.9 x 10 6 hrs
UL, CUL, TUV
1.4 oz
1
20
30
40
50
60
70
80
LOAD %
Notes
MTBF predictions may vary slightly from model to model.
††
Industrial temp range available
†
Specifications typically at 25°C, normal line, and full load, unless otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Units are water-washable and fully compatible with commercial spray or immersion
post wave-solder washing equipment.
OBD SERIES - DUAL OUTPUT, 25 WATT
MODELS - (See the last page of this file for options.)
Vin
(Volts)
Vin Range
(Volts)
Iin Max.*
(Amps)
Vout
(Volts)
Iout Rated
(Amps)
Ripple & Noise
Pk-Pk (mV)
Efficiency
Typ. **
Model
24
24
48
48
48
18 - 36
18 - 36
36 - 75
36 - 75
36 - 75
1.8
1.7
0.93
0.91
0.91
±5
±15
±5
±12
±15
±2.5
±0.85
±2.5
±1.0
±0.85
75
150
75
120
150
83%
88%
80%
86%
88%
OBD025YGG †
OBD025YJJ †
OBD025ZGG
OBD025ZHH
OBD025ZJJ †
† Denotes advanced product release. Consult factory for product availability.
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
MECHANICAL DRAWING
2.00"
(50.8mm)
0.18" MIN.
(4.6mm)
5
1.100"(27.9mm)
6
0.700"(17.8mm)
DIA 0.040"
(1.0mm)
0.600"(15.2mm)
1
0.400"(10.2mm)
2
0.200"(5.1mm)
3
0
4
2.00"
BOTTOM VIEW
(50.8mm)
7
0.300"(7.6mm)
8
-0.100"(2.5mm)
-0.50"(-12.7mm)
1.800"
(45.7mm)
0
-0.10"
(-2.5mm)
Thermal Impedance
Natural convection
100 LFM
200 LFM
300 LFM
400 LFM
10.3
7.7
6.3
5.1
4.1
°C/W
°C/W
°C/W
°C/W
°C/W
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated for
specific application.
0.42"
(10.7mm)
Pin
Tolerances
Function
1
2
3
4
5
6
7
8
+Vin
-Vin
No Conn.
Enable
+V out
Common
-V out
Trim
2
Inches:
.XX ± 0.020
.XXX ± 0.010
(Millimeters)
.X ± 0.5
.XX ± 0.25
Pin:
± 0.002
± 0.05
Case:
+ 0.04, - 0.00
+ 1.0, - 0.0
(Tolerances as listed unless otherwise specified.)
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that
you prefer and add them to the model number. Example ordering options are located below the
options table.
OPTION
SUFFIX
APPLICABLE SERIES
Negative Logic
N
HAS, HBD, HBS, HES, LES, QBS,
QES, TES, TQD
Lucent Compatible Trim
T
HAS, HBD, HBS, HES, QBS, QES
Terminal Strip
TS
REMARKS
TTL “Low” Turns Module ON
TTL “High” Turns Module OFF
XWS, XWD, XWT
Trim
1
IAS, LES
Enable
2
IAD, IAS, LES, SMS
Trim and Enable
3
IAS, LES
Current Share
4
SMS
Headerless
Y
Encapsulated EWS, IWS, OWS
PIN LENGTH AND HEATSINK
OPTIONS
Standard Pin Length is 0.180”
(4.6mm)
0.110” (2.8mm) Pin Length
8
All Units (Except SMS)
0.150” (3.8mm) Pin Length
9
All Units (Except SMS)
0.24” (6.1mm) Horizontal Heatsink
1H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.24” (6.1mm) Vertical Heatsink
1V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.45” (11.4mm) Horizontal
Heatsink
2H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.45” (11.4mm) Vertical Heatsink
2V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.95” (24.1mm) Horizontal
Heatsink
3H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.95” (24.1mm) Vertical Heatsink
3V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
Example Options:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and
0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
3