ETC OM1805NMM

OM1805NMM OM1815NMM
OM1812NMM
HERMETIC SURFACE MOUNT FIXED VOLTAGE POSITIVE
REGULATORS APPROVED TO DESC DRAWINGS
Three Terminal, Fixed Voltage, 1.5 Amp
Precision Positive Regulators In Hermetic
Surface Mount Package
FEATURES
•
•
•
•
•
•
Hermetic Surface Mount Package
Output Voltages: +5V, +12V, +15V
Output Voltages Set Internally To ±1%
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Hi-Rel Screening Available
DESCRIPTION
These three terminal positive regulators are supplied in a hermetically sealed surface
mount package. All protective features are designed into the circuit including thermal
shutdown, current limiting and safe-area control. With heat sinking, they can deliver
over 1.5 amps of output current. These units feature internally trimmed output
voltages to ±1% of nominal voltage. Standard voltages are +5V, +12V, and +15V.
These units are ideally suited for Military applications where a hermetic surface
mount package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number
5962-8778201 NX
5962-8777601 NX
5962-8855301 NX
Omnirel Part Number
OM1805NMM
OM1812NMM
OM1815NMM
3.5
4 11 R0
3.5 - 37
OM1805NMM - OM1815NMM
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C TC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15W
TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3W
Thermal Resistance
θJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5°C/W
θJA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120°C/W
a
ELECTRICAL CHARACTERISTICS 5 Volt
VIN = 10V, Io = 500mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
4.92
5.08
V
4.85
5.15
V
VIN = 7.5V to 20V
•
IO = 5mA to 1.0A, P < 15 W
Line Regulation
VRLINE
VIN = 7.5V to 20V
(Note 1)
mV
12
mV
4
mV
•
10
mV
12
mV
25
mV
VIN = 8.0V to 12V
(Note 4)
Load Regulation
5
•
VRLOAD
IO = 5mA to 1.5 Amp
IO = 5mA to 1.0Amp
(Note 1)
•
IO = 250mA to 750 mA
Standby Current Drain
6
mV
•
15
mV
6
mA
6.5
mA
VIN = 7.5V to 20V
•
•
0.8
mA
IO = 5mA to 1000mA
•
0.5
mA
ISCD
Standby Current Drain
∆ISCD
Change With Line
(Line)
Standby Current Drain
∆ISCD
Change With Load
(Load)
Dropout Voltage
VDO
TA = 25°C, ∆VOUT = 100mV, IO = 1.0A
Peak Output Current
IO (pk)
TA = 25°C
Short Circuit Current
IDS
VIN = 35V
1.5
•
(Note 2)
2.5
V
3.3
A
1.2
A
2.8
A
∆VIN
f =120 Hz, ∆VIN = 10V
∆VOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
∆VOUT
TA = 25°C, t = 1000 hrs.
75
(Note 3)
∆t
Ripple Rejection
Output Noise Voltage
68
•
dB
60
dB
(Note 3)
3.5
µV/V
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
3.5 - 38
OM1805NMM - OM1815NMM
ELECTRICAL CHARACTERISTICS 12 Volt
VIN = 19V, Io = 500mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
11.88
12.12
V
11.64
12.36
V
18
mV
VIN = 14.5V to 27V
•
IO = 5mA to 1.0 A, P < 15W
Line Regulation
VIN = 14.5V to 27V
VRLINE
•
(Note 1)
50
mV
9
mV
VIN = 16V to 22V
(Note 4)
•
Load Regulation
IO = 5mA to 1.5 Amp
VRLOAD
IO = 5mA to 1.0 Amp
(Note 1)
•
IO = 250mA to 750 mA
•
Standby Current Drain
∆ISCD
Change With Line
(Line)
Standby Current Drain
∆ISCD
Change With Load
(Load)
mV
mV
60
mV
20
mV
40
mV
6.0
mA
6.5
mA
VIN = 15V to 30V
•
•
0.8
mA
IO = 5mA to 1000mA
•
0.5
mA
•
ISCD
Standby Current Drain
30
32
Dropout Voltage
VDO
∆VOUT = 100mV, IO = 1.0A
Peak Output Current
IO (pk)
TA = 25°C
Short Circuit Current
IDS
VIN = 35V
1.5
•
(Note 2)
2.5
V
3.3
A
1.2
A
2.8
A
∆VIN
f =120 Hz, ∆VIN = 10V
∆VOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
∆VOUT
TA = 25°C, t = 1000 hrs.
120
(Note 3)
∆t
Ripple Rejection
Output Noise Voltage
61
•
dB
54
dB
(Note 3)
µV/V
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
MECHANICAL OUTLINE
.140
.015
.075
.140
.140
1
2
.157
CONNECTION
.075
.030
MIN.
3
.415
.062
.375
3.5 - 39
Pin 1 Input
Pin 2 Output
Pin 3 Ground
3.5
OM1805NMM - OM1815NMM
ELECTRICAL CHARACTERISTICS 15 Volt
VIN = 23V, Io = 500mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
14.8
15.2
V
14.6
15.4
V
20
mV
•
VIN = 18.5V to 30V
IO = 5mA to 1.0 A, P < 15W
Line Regulation
VIN = 17.5V to 30V
VRLINE
•
(Note 1)
VIN = 20V to 26V
(Note 4)
•
Load Regulation
IO = 5mA to 1.5 Amp
VRLOAD
•
IO = 5mA to 1.0 Amp
(Note 1)
IO = 250mA to 750 mA
•
Standby Current Drain
∆ISCD
Change With Line
(Line)
Standby Current Drain
∆ISCD
Change With Load
(Load)
mV
15
mV
25
mV
35
mV
75
mV
21
mV
45
mV
6.0
mA
6.5
mA
VIN = 18.5V to 30V
•
•
0.8
mA
IO = 5mA to 1000mA
•
0.5
mA
2.5
V
3.3
A
ISCD
Standby Current Drain
50
Dropout Voltage
VDO
TA = 25°C, ∆VOUT = 100mV, IO = 1.0A
Peak Output Current
IO (pk)
TA = 25°C
Short Circuit Current
IDS
VIN = 35V
1.5
•
(Note 2)
1.2
A
2.8
A
∆VIN
f =120 Hz, ∆VIN = 10V
∆VOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
∆VOUT
TA = 25°C, t = 1000 hrs.
150
(Note 3)
∆t
Ripple Rejection
Output Noise Voltage
54
•
dB
52
dB
µV/V
(Note 3)
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
TYPICAL PERFORMANCE CHARACTERISTICS
2.5
3.5
Output Current (A)
3
Tj = -55°C
100
2
80
IOUT = 1A
2.5
1.5
2
IOUT = 500mA
Tj = 25°C
1
1.5
IOUT = 0A
1
0.5
Tj = 150°C
0.5
0
0
5
10
15
20
25
30
35
0
-75-50 -25 0
VOUT = 5V
60
40
VIN - V = 8VDC +3.5Vrms
IOUT = 1A
Tj = 25°C
20
∆VOUT = 100MV
∆VOUT = 100mV
Ripple Rejection (dB)
3.5
2 5 5 0 7 5 100 125150
0
10
Input To Output Differential (V)
Junction Temperature (°C)
100
1k
10k
Frequency (Hz)