ANADIGICS PD500-1XX

PD500
500μm InGaAs Photodiode
FEATURES
•
Planar Structure
•
Dielectric Passivation
•
High Shunt Resistance
•
High Responsivity
APPLICATIONS
•
High Sensitivity Instrumentation
•
Laser Back Facet Monitoring
PD500-0xx
Ceramic Sub-Mount
PD500-1xx
TO can Package
PRODUCT DESCRIPTION
The PD500 is an InGaAs photodiode with a
photosensitive region 500μm in diameter. It is
intended for use in high sensitivity
instrumentation, laser back-facet monitoring
and low bit rate communication systems.
Planar semiconductor design and dielectric
passivation provide superior noise performance.
The device can be assembled on a ceramic submount or in an hermetic TO46 can. Custom
packages are an option.
ELECTRICAL CHARACTERISTICS
Table 1: Electrical Specifications
PARAMETER
Dark Current (ID) (1)
Capacitance (2)
Responsivity at 1310nm
Responsivity at 1550nm
Rise/Fall time
Shunt Resistance (Class A) (2)
(1) 5V reverse bias
(2) 0V reverse bias
MIN
0.80
0.85
50
TYP
25
20
0.90
0.95
3
-
MAX
-
UNIT
nA
pF
A/W
A/W
ns
MΩ
PD500
ELECTRICAL CHARACTERISTICS (cont)
Table 2: Absolute Maximum Ratings
PARAMETER
MIN
MAX
UNIT
Forward Current
50
mA
Reverse Current
5
mA
Reverse Voltage
15
V
Optical input power
5
mW
Operating Case Temperature
-40
+85
ºC
Storage Temperature
-40
+85
ºC
Soldering temperature (10 seconds)
+250
ºC
Stresses in excess of the absolute ratings may cause permanent damage. Functional
operation is not implied under these conditions. Exposure to absolute ratings for extended
periods of time may adversely affect reliability.
ORDERING INFORMATION
Part Number
PD500-0xx
PD500-1xx
Options
Custom defined size and electrical layout
Package: TO46
Number of pins: 2, 3
Cap: Window, AR / Non-AR coated.
Cap plating: Gold or nickel
Please contact Anadigics for the specific part number and pinout that suits your needs
ANADIGICS, Inc.
829 Flynn Road
Camarillo, California 93012, U.S.A.
Tel: +1 (805) 445-4500
Fax: +1 (805) 445-4502
URL: http://www.anadigics.com
E-mail: [email protected]
IMPORTANT NOTICE
ANADIGICS, Inc. reserves the right to make changes to its products or discontinue any product at any
time without notice. The product specifications contained in Advanced Product Information sheets and
Preliminary Data sheets are subject to change prior to a product’s formal introduction. Information in
Data Sheets have been carefully checked and are assumed to be reliable; however, ANADIGICS
assumes no responsibility for inaccuracies. ANADIGICS strongly urges customers to verify that the
information they are using is current before placing orders.
WARNING
ANADIGICS products are not intended for use in life support appliances, devices, or systems. Use of
an ANADIGICS product in any such application without written consent is prohibited.
Rev 1.0
2