PerFormanCe POWER PFC500 The PFC500 products of the PerFormanCe Power series combine high performance midrange power with high power density (4.4 watts/in3), active Power Factor Correction (PFC) and high reliability to meet the requirements of commercial and industrial systems. include remote sense, power fail, logic level inhibit, DC power good. Main channel current sharing is provided for redundant applications. The PFC500 is available with SAE mountings or optional metric mountings. Providing tightly regulated DC power, the PFC500 is delivers full output performance with only 300 Linear Feet per Minute (LFM) forced air cooling (factory installed fan optional). Other features The PFC500 product line is approved to the latest international regulatory standards, and displays the CE Mark. FEATURES • Power Factor Correction (PFC) Meets EN61000-3-2 • Fully Regulated Outputs • Remote Sense • Current Share, Power Fail, and Power Good Signals • Overtemperature, Overvoltage, and Overcurrent Protected • Available with Metric or SAE Mountings • Input Transient & ESD Compliance to EN61000-4-2/-3/-4/-5 • Fan Output Voltage and Optional Fan • Optional Isolation Diodes for Parallel or Redundant Operation SINGLE OUTPUT MODEL SELECTION CHART MODEL PFC500-1024 PFC500-1028 PFC500-1048 NOTES: OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT (NOTE 1) LINE REGULATION LOAD REGULATION (NOTE 3) RIPPLE & NOISE %p-p (NOTE 2) INITIAL SETTING ACCURACY 24V 28V 48V 21.6V to 26.4V 25.2V to 30.8V 46.0V to 56.0V 21A 17.9A 10.4A 0.5% 0.5% 0.5% 0.2% 0.2% 0.5% 1% 1% 1% 23.88V to 24.12V 27.86V to 28.14V 47.52V to 48.48V 1) Output currents ratings are expressed with 300 LFM forced air. 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 3) Remote sense connected. INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN Input Voltage - AC Input Frequency Brown Out Protection Hold-Up Time Input Current Input Protection Inrush Surge Current Continuous input range. AC Input. Lowest AC input voltage that regulation is maintained with full rated loads. Over full AC input voltage range at full rated load. 85 VAC at full rated load. Non-user serviceable internally located AC input line fuse, F10A, 250V. Internally limited by thermistor, one cycle, 25°C. 110 VAC 85 47 85 20 NOM Rev. 04/2000 Per EN61000-3-2. Switching frequency of main transformer. VAC Hz VAC mS ARMS 35 65 0.98 100 1 UNITS 264 63 7.8 220 VAC Power Factor Operating Frequency MAX APK W/VA kHz PerFormanCe POWER PFC500 OUTPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN Efficiency Minimum loads Full rated load, 110 VAC. Varies with distribution of loads among outputs. PFC500-1024 PFC500-1028 PFC500-1048 Full load, 20MHz bandwidth. 300 LFM forced air cooling required for operation. See optional fan. Continuous power, multiple output models. Output voltage overshoot/undershoot at turn-on. Without connection of remote sense. PFC500-1024 PFC500-1028 PFC500-1048 Recovery time, to within 1% of initial set point due to a 50-100% load change, 3% max. deviation. (Main output of multi-output units). Time required for initial output voltage stabilization. Time required for output voltage to rise from 10% to 90%. 75 0.6 0.6 1.2 See Model Selection Charts Ripple and Noise Output Power Overshoot / Undershoot Regulation Transient Response Turn-on Delay Turn-on Rise Time NOM MAX 500 UNITS % Amps Watts 0 0.8 0.7 1.0 1 V % mS 1 Sec mS MAX UNITS 10 INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION Overvoltage Protection PFC500-1024 27.0 30.7 PFC500-1028 32.0 35.0 PFC500-1048 60.0 70.0 Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. System shutdown due to excessive internal temperature, automatic reset. Total voltage compensation for cable losses with respect to the main output. 250 Accuracy of shared current with up to 6 parallel units. 10 TTL compatible logic signal will inhibit outputs by the application of a logic low signal. An open circuit or external TTL high signal allows normal operation. TTL compatible logic signal. Time before regulation dropout due to 4 loss of input power at 110 VAC. TTL compatible signal. Signal is low if main output is greater PFC500-1024 22.08 27.36 or less than 10% of nominal. PFC500-1028 25.20 30.80 PFC500-1048 44.20 54.72 Provides 170mA current to user supplied fan if fan option is not selected. 12 Overload Protection Overtemperature Protection Remote Sense Current Share Inhibit Input Power Fail Warning Power Good Fan Voltage MIN NOM V mV % mS V V SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION Agency Approvals ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection UL1950. CSA 22.2 NO. 234/950. EN60950 (TÜV). Input to output. FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. Per EN61000-4-2, level 4. Per EN61000-4-3, level 3. Per EN61000-4-4, level 4. Per EN61000-4-5 class 3. Insulation Resistance Leakage Current Input to output. Per EN60950, 264 VAC. Dielectric Withstand Voltage Electromagnetic Interference MIN NOM MAX Approved Line to Line Line to Ground 2600 B B 8 10 ±4 1 2 VDC Class kV V/M kV kV 10 2.0 2 UNITS MΩ mA PerFormanCe POWER PFC500 ENVIRONMENTAL SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION Altitude Operating. Non-Operating. MIN Operating Temperature At 100% load At 50% load Derate linearly above 50°C by 2.5% per °C. Storage Temperature Forced Air Cooling Temperature Coefficient Relative Humidity Shock Vibration Forced air cooling of 300 LFM is required if the internal fan is not specified. Cooling air velocity is measured 1/4" above, at the middle of the chassis. Airflow direction is from the input section to the output section. 0°C to 70°C (after 15 minute warm-up). Non-Condensing. Operating: 10±3mSec, 3 axis, Half Sine. Non-operating: 10±3mSec, 3 axis, Half Sine. Operating: 5-32Hz 32-2000Hz Sinusoidal Non-operating: NOM 0 0 -55 ±0.02 5 MAX UNITS 10k 40k 50 70 85 ASL Ft. ASL Ft. °C °C °C ±0.05 95 20 40 0.02 1 6.15 %/°C %RH G in (DA) GPK GRMS OPTIONS DESCRIPTION NOTES Isolation Diodes Add “D” as a suffix to the model number to order factory installed isolation diodes for parallel or redundant operation. Add “F” as a suffix to the model number to order integral fan. (provides required 300 LFM of forced air cooling). Fan Metric Mounting SIZE IMPACT Add “M” as a suffix to the model number to order chassis with M4 x 0.7 mounting inserts. N/A 10.50" x 5.00" x 2.50" (266.7mm x 127.0mm x 63.5mm) N/A For the Most Up-To-Date Information www.power-one.com 24 Hours/Day—7 Days/Week NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. 3 PerFormanCe POWER PFC500 OVERALL SIZE: 9.00" x 5.00" x 2.50" (228.6mm x 127.0mm x 63.5mm) OVERALL LENGTH WITH FAN: 10.50" (266.7mm) WEIGHT: 4.3 LBS (1.95 kg) 8-32 FLUSH NUT 8 PLACES BOTH SIDES TYP. WITH METRIC MOUNTING OPTION: M4 X 0.7, 8 PLACES 2.50" (63.5mm) FAN OPTION 1.20" (30.4mm) 9.00" (228.6mm) 1.50" (38.1mm) 1. 25" (31.8mm) 6.50" (165.1mm) 0.70" (17.8mm) 5.00" (127.0mm) SUGGESTED AIR FLOW 3.900" (99.1mm) 3.12" (79.2mm) FAN OPTION (TOP VIEW) 1 2 J4 +V1 3 TB1 4 1 AC-L 5 6 AC-N CHASSIS GND J3 -V1/RTN P4,P3,P5 Mating Housing: Molex 5051, 5102, or Equiv. P4,P3,P5 Mating Terminals: Molex 4809 or 40445, or Equiv. INPUT & OUTPUT CONNECTIONS: 6-32 SCREW TERMINAL ON 0.375" (9.5mm) CENTERS 0.090" (2.3mm) ALUMINUM ALLOY, WITH CLEAR FINISH 4 J5 J4, J3, J5 Molex Series 5048, 0.46mm Square pins on 2.50mm centers. Customer connection: 3 CHASSIS: N/C +SHARE PIN 1 SIG GND PIN 2 PF PIN 3 PWR GOOD PIN 4 N/C PIN 3 INHIBIT TB2 1 V1 ADJ PIN 4 +FAN PIN 1 +SENSE PIN 2 —SENSE (BOTTOM VIEW)