PerFormanCe POWER PFC375 The PFC375 products of the PerFormanCe Power series incorporate high performance midrange power, active Power Factor Correction (PFC), and high reliability to meet varied commercial and industrial requirements. cooling (factory installed fan optional). Other features include remote sense, power fail, logic level inhibit, DC power good. Main channel current sharing is provided for redundant applications. The PFC375 is available with SAE mountings or optional metric mountings. Providing tightly regulated DC power in a wide variety of single and multiple output configurations, the PFC375 is designed to provide full output power with only 300 Linear Feet per Minute (LFM) forced air The PFC375 product line is approved to the latest international regulatory standards, and displays the CE Mark. FEATURES • Power Factor Correction (PFC) Meets EN61000-3-2 • Fully Regulated Outputs • Main Output Remote Sense • Current Share, Power Fail, and Power Good Signals • Overtemperature, Overvoltage, and Overcurrent Protected • Available with Metric and SAE Mountings • Input Transient & ESD Compliance to EN61000-4-2/-3/-4/-5 • Fan Output Voltage and Optional Fan SINGLE OUTPUT MODEL SELECTION CHART MODEL PFC375-1012 PFC375-1015 PFC375-1024 PFC375-1028 PFC375-1048 NOTES: OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT (NOTE 1) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 2) INITIAL SETTING ACCURACY 12V 15V 24V 28V 48V 10.8V to 13.5V 12.0V to 17.0V 21.6V to 26.4V 25.2V to 30.8V 46.0V to 56.0V 30A 25A 15A 13.4A 7.8A 0.2% 0.2% 0.5% 0.5% 0.5% 0.8% 0.6% 0.8% 0.9% 1.0% 1% 1% 1% 0.9% 1% 11.94V to 12.06V 14.94V to 15.06V 23.88V to 24.12V 27.86V to 28.14V 47.52V to 48.48V 1) Output currents ratings are expressed with 300 LFM forced air. 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. MULTIPLE OUTPUT MODEL SELECTION CHART - ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS MODEL PFC375-3000 PFC375-3001 PFC375-3002 PFC375-3004 PFC375-4000 Rev. 04/2000 OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT (NOTE 1) PEAK OUTPUT CURRENT (NOTE 2) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 3) INITIAL SETTING ACCURACY +5V +12V 12V +5V +15V 15V +5V +12V 5V +5V +12V 24V +5V +12V 12V 5V 4.5V to 5.5V 11.3V to 12.6V 11.3V to 12.6V 4.5V to 5.5V 14.2V to 15.8V 14.2V to 15.8V 4.5V to 5.5V 11.3V to 12.6V 4.5V to 5.5V 4.5V to 5.5V 11.3V to 12.6V 22.0V to 28.0V 4.5V to 5.5V 11.3V to 12.6V 11.3V to 12.6V 4.9V to 5.1V 3.5 - 40A 10A 6A 3.5 - 40A 10A 6A 3.5 - 40A 10A 6A 3.5 - 40A 10A 3A 3.5 - 40A 10A 6A 3A 40A 16A 10A 40A 16A 10A 40A 16A 6A 40A 16A 3A 40A 16A 6A 3A 0.4% 0.9% 0.9% 0.4% 0.7% 0.7% 0.4% 0.9% 0.4% 0.4% 0.9% 0.5% 0.4% 0.9% 0.9% 2% 0.8% 0.9% 0.9% 0.8% 0.7% 0.7% 0.8% 0.9% 1% 0.8% 0.9% 0.8% 0.8% 0.9% 0.9% 2% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 2.4% 4.98V to 5.02V 11.9V to 12.1V 11.9V to 12.1V 4.98V to 5.02V 14.9V to 15.1V 14.9V to 15.1V 4.98V to 5.02V 11.9V to 12.1V 4.98V to 5.02V 4.98V to 5.02V 11.9V to 12.1V 23.8V to 24.2V 4.98V to 5.02V 11.9V to 12.1V 11.9V to 12.1V 4.9V to 5.1V 1 PerFormanCe POWER PFC375 MULTIPLE OUTPUT MODEL SELECTION CHART (CONT.) - ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT (NOTE 1) PEAK OUTPUT CURRENT (NOTE 2) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 3) INITIAL SETTING ACCURACY +5V +12V 12V 12V +5V +12V 12V 24V +5V +12V 15V 15V +5V +12V 24V 24V +24V +5V 12V 12V +24V +5V 15V 15V 4.5V to 5.5V 11.3V to 12.6V 11.3V to 12.6V 11.0V to 16.0V 4.5V to 5.5V 11.3V to 12.6V 11.3V to 12.6V 22.0V to 28.0V 4.5V to 5.5V 11.3V to 12.6V 14.2V to 15.8V 14.2V to 15.8V 4.5V to 5.5V 11.3V to 12.6V 22.0V to 28.0V 22.0V to 28.0V 21.5V to 26.4V 4.5V to 5.5V 11.4V to 12.6V 11.4V to 12.6V 21.5V to 26.4V 4.5V to 5.5V 14.2V to 16.0V 13.7V to 16.0V 3.5 - 40A 10A 6A 3A 3.5 - 40A 10A 6A 3A 3.5 - 40A 10A 4A 4A 3.5 - 40A 10A 3A 3A 1 - 10A 10A 4A 4A 1 - 10A 10A 4A 4A 40A 16A 6A 3A 40A 16A 6A 3A 40A 16A 4A 4A 40A 16A 3A 3A 10A 16A 4A 4A 10A 16A 4A 4A 0.4% 0.9% 0.9% 0.9% 0.4% 0.9% 0.9% 0.5% 0.4% 0.9% 0.7% 0.7% 0.4% 0.9% 0.5% 0.5% 0.5% 0.4% 0.5% 0.5% 0.5% 0.4% 0.5% 0.5% 0.8% 0.9% 0.9% 0.9% 0.8% 0.9% 0.9% 0.8% 0.8% 0.9% 0.7% 0.7% 0.8% 0.9% 0.8% 0.8% 0.8% 0.8% 1% 1% 0.8% 0.8% 0.8% 0.8% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 4.98V to 5.02V 11.9V to 12.1V 11.9V to 12.1V 11.9V to 12.1V 4.98V to 5.02V 11.9V to 12.1V 11.9V to 12.1V 23.8V to 24.2V 4.98V to 5.02V 11.9V to 12.1V 14.9V to 15.1V 14.9V to 15.1V 4.98V to 5.02V 11.9V to 12.1V 23.8V to 24.2V 23.8V to 24.2V 23.8V to 24.2V 4.98V to 5.02V 11.9V to 12.1V 11.9V to 12.1V 23.8V to 24.2V 4.98V to 5.02V 14.9V to 15.1V 14.9V to 15.1V +5V +12V PFC375-4500 Advanced Product Release 12V 5V 4.5V to 5.5V 11.3V to 12.6V 11.3V to 12.6V 4.5V to 5.5V 3.5 - 50A 10A 6A 3A 50A 16A 6A 3A 0.4% 0.9% 0.9% 2% 0.8% 0.9% 0.9% 0.9% 1% 1% 1% 1% 4.98V to 5.02V 11.9V to 12.1V 11.9V to 12.1V 4.9V to 5.1V MODEL PFC375-4001 PFC375-4002 PFC375-4004 PFC375-4005 (Note 4) PFC375-4200 PFC375-4201 NOTES: 1) 2) 3) 4) Output currents ratings are expressed with 300 LFM forced air. Peak loads up to 450 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 450 Watts. Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. V3 and V4 may be series connected to obtain 48V. INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN Input Voltage - AC Input Frequency Brown Out Protection Hold-Up Time Input Current Input Protection Inrush Surge Current Continuous input range. AC Input. Lowest AC input voltage that regulation is maintained with full rated loads. Over full AC input voltage range at full rated load. 85 VAC at full rated load. Non-user serviceable internally located AC input line fuse, F10A, 250V. Internally limited by thermistor, one cycle, 25°C. 110 VAC 220 VAC Per EN61000-3-2. Switching frequency of main transformer. 85 47 85 20 Power Factor Operating Frequency 2 NOM MAX UNITS 264 63 VAC Hz VAC mS ARMS 6 35 65 0.98 100 APK W/VA kHz PerFormanCe POWER PFC375 OUTPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN Efficiency Minimum Loads Full rated load, 110 VAC. Varies with distribution of loads among outputs. Single output models. Multiple output models, 5V main output only. Multiple output models, 24V main output only. Full load, 20MHz bandwidth. 300 LFM forced air cooling required for operation. See optional fan. Continuous power, multiple output models. Peak power, all models. Output voltage overshoot/undershoot at turn-on. Varies by output. Total regulation includes: line changes from 85-132 VAC or 170-264 VAC, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 3% max. deviation. (Main output only on multi-output units). Time required for initial output voltage stabilization. Time required for output voltage to rise from 10% to 90%. 68 0 3.5 1 See Model Selection Charts Ripple and Noise Output Power Overshoot / Undershoot Regulation Transient Response Turn-On Delay Turn-On Rise Time NOM MAX 375 450 0 UNITS % Amps Watts V See Model Selection Charts 1 mS 1 Sec mS MAX UNITS 10 INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION Overvoltage Protection Provided on single output units and the main output only of multiple output units. PFC375-30XX, PFC375-40XX, PFC375-45XX 6.0 6.4 PFC375-1012 13.5 15.5 PFC375-1015 17.0 19.5 PFC375-1024 27.0 30.7 PFC375-1028 30.8 35.0 PFC375-1048 60.0 70.0 PFC375-42XX 27.0 30.7 Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. System shutdown due to excessive internal temperature, automatic reset. Total voltage compensation for cable losses with respect to the main output. 250 Accuracy of shared current with up to 6 parallel units. 10 TTL compatible logic signal will inhibit outputs by the application of a logic low signal. An open circuit or external TTL high signal allows normal operation. TTL compatible logic signal. Time before regulation dropout due to 5 loss of input power at 110 VAC. TTL compatible signal. Signal is low if main output is greater or less than 10% of nominal. Provides 170mA current to user supplied fan if fan option is not selected. 12 Overload Protection Overtemperature Protection Remote Sense Current Share Inhibit Input Power Fail Warning Power Good Fan Voltage MIN NOM V mV % mS V SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION Agency Approvals ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection UL1950. CSA 22.2 NO. 234/950. EN60950 (TÜV). Input to output. FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. Per EN61000-4-2, level 4. Per EN61000-4-3, level 3. Per EN61000-4-4, level 4. Per EN61000-4-5 class 3. Insulation Resistance Leakage Current Input to output. Per EN60950, 264 VAC. Dielectric Withstand Voltage Electromagnetic Interference MIN NOM MAX Approved Line to Line Line to Ground 2600 B B 8 10 ±4 1 2 VDC Class kV V/M kV kV 10 2.0 3 UNITS MΩ mA PerFormanCe POWER PFC375 ENVIRONMENTAL SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION Altitude Operating. Non-Operating. MIN Operating Temperature At 100% load At 50% load Derate linearly above 50°C by 2.5% per °C. Storage Temperature Forced Air Cooling Temperature Coefficient Relative Humidity Shock Vibration Forced air cooling of 300 LFM is required if the internal fan option is not specified. Cooling air velocity is measured 1/4" above, at the middle of the chassis. Airflow direction is from the input section to the output section. 0°C to 70°C (after 15 minute warm-up). Non-Condensing. Operating: 10±3mSec, 3 axis, Half Sine. Non-operating: 10±3mSec, 3 axis, Half Sine. Operating: 5-32Hz 32-2000Hz Sinusoidal Non-operating: NOM 0 0 -55 ±0.02 5 MAX UNITS 10k 40k 50 70 85 ASL Ft. ASL Ft. °C °C °C ±0.05 95 20 40 0.02 1 6.15 %/°C %RH G in (DA) GRMS GRMS OPTIONS DESCRIPTION NOTES Fan Add “F” as a suffix to the model number to order integral fan. (provides required 300 LFM of forced air cooling). Add “M” as a suffix to the model number to order chassis with M4 x 0.7 mounting inserts. Metric Mounting SIZE IMPACT 10.50" x 5.00" x 2.50" (266.7mm x 127.0mm x 63.5mm) 9.00" x 5.00" x 2.50" (228.6mm x 127.0mm x 63.5mm) NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. 4 PerFormanCe POWER PFC375 OVERALL SIZE: 9.00" x 5.00" x 2.50" (228.6mm x 127.0mm x 63.5mm) OVERALL LENGTH WITH FAN: 10.50" (266.7mm) WEIGHT: 4.3 LBS (1.95 kg) 8-32 FLUSH NUT 8 PLACES BOTH SIDES TYP. WITH METRIC MOUNTING OPTION: M4 X 0.7, 8 PLACES 2.50" (63.5mm) FAN OPTION 1.20" (30.4mm) 9.00" (228.6mm) 1.50" (38.1mm) 1. 25" (31.8mm) 6.50" (165.1mm) 0.70" (17.8mm) 5.00" (127.0mm) SUGGESTED AIR FLOW 3.900" (99.1mm) 3.12" (79.2mm) (BOTTOM VIEW) TERMINAL BLOCK MAIN OUTPUT (PFC375-4200, PFC375-4201, V1 ADJ TB2 1 V2 ADJ TB1 V3 ADJ 1 AC-L AC-N PIN 1 (V2) RTN PIN 2 (V2) PIN 3 (V3) PIN 4 (V3) RTN PIN 5 (V4) PIN 6 (V4) RTN PINS 3 & 4 (V1) RTN V1 ADJ V2 ADJ V3 ADJ CHASSIS GND 3 V4 ADJ V4 ADJ PIN 5 (V2) RTN PIN 6 (V2) PIN 7 (V3) PIN 8 (V3) RTN PIN 9 (V4) PIN 10 (V4) RTN J4 P4,P3,P5 Mating Housing: Molex 5051 P4,P3,P5 Mating Terminals: Molex 4809 or 40445 0.090" (2.3mm) ALUMINUM ALLOY, WITH CLEAR FINISH 5 J5 Customer connection: INPUT & OUTPUT CONNECTIONS: 6-32 SCREW TERMINAL ON 0.375" (9.5mm) CENTERS BUS BAR MAIN OUTPUT, E1 & E2, 10-32 SCREW TERMINAL CHASSIS: J3 N/C FAN OPTION (TOP VIEW) PINS 1 & 2 (V1) +SHARE E2 (V1) RTN AND ALL SINGLE OUTPUT UNITS EXCEPT PFC375-1005) PIN 1 SIG GND PIN 2 PF PIN 3 PWR GOOD PIN 4 N/C 1 PIN 3 INHIBIT TB3 PIN 4 +FAN E1 (V1) PIN 1 +SENSE PIN 2 —SENSE BUS BAR MAIN OUTPUT