ETC PFC375

PerFormanCe POWER PFC375
The PFC375 products of the PerFormanCe Power series incorporate
high performance midrange power, active Power Factor Correction
(PFC), and high reliability to meet varied commercial and industrial
requirements.
cooling (factory installed fan optional). Other features include remote
sense, power fail, logic level inhibit, DC power good. Main channel
current sharing is provided for redundant applications. The PFC375
is available with SAE mountings or optional metric mountings.
Providing tightly regulated DC power in a wide variety of single and
multiple output configurations, the PFC375 is designed to provide full
output power with only 300 Linear Feet per Minute (LFM) forced air
The PFC375 product line is approved to the latest international
regulatory standards, and displays the CE Mark.
FEATURES
• Power Factor Correction (PFC) Meets EN61000-3-2
• Fully Regulated Outputs
• Main Output Remote Sense
• Current Share, Power Fail, and Power Good Signals
• Overtemperature, Overvoltage, and Overcurrent Protected
• Available with Metric and SAE Mountings
• Input Transient & ESD Compliance to EN61000-4-2/-3/-4/-5
• Fan Output Voltage and Optional Fan
SINGLE OUTPUT MODEL SELECTION CHART
MODEL
PFC375-1012
PFC375-1015
PFC375-1024
PFC375-1028
PFC375-1048
NOTES:
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
12V
15V
24V
28V
48V
10.8V to 13.5V
12.0V to 17.0V
21.6V to 26.4V
25.2V to 30.8V
46.0V to 56.0V
30A
25A
15A
13.4A
7.8A
0.2%
0.2%
0.5%
0.5%
0.5%
0.8%
0.6%
0.8%
0.9%
1.0%
1%
1%
1%
0.9%
1%
11.94V to 12.06V
14.94V to 15.06V
23.88V to 24.12V
27.86V to 28.14V
47.52V to 48.48V
1) Output currents ratings are expressed with 300 LFM forced air.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
MULTIPLE OUTPUT MODEL SELECTION CHART - ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
MODEL
PFC375-3000
PFC375-3001
PFC375-3002
PFC375-3004
PFC375-4000
Rev. 04/2000
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT (NOTE 1)
PEAK OUTPUT
CURRENT (NOTE 2)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 3)
INITIAL SETTING
ACCURACY
+5V
+12V
12V
+5V
+15V
15V
+5V
+12V
5V
+5V
+12V
24V
+5V
+12V
12V
5V
4.5V to 5.5V
11.3V to 12.6V
11.3V to 12.6V
4.5V to 5.5V
14.2V to 15.8V
14.2V to 15.8V
4.5V to 5.5V
11.3V to 12.6V
4.5V to 5.5V
4.5V to 5.5V
11.3V to 12.6V
22.0V to 28.0V
4.5V to 5.5V
11.3V to 12.6V
11.3V to 12.6V
4.9V to 5.1V
3.5 - 40A
10A
6A
3.5 - 40A
10A
6A
3.5 - 40A
10A
6A
3.5 - 40A
10A
3A
3.5 - 40A
10A
6A
3A
40A
16A
10A
40A
16A
10A
40A
16A
6A
40A
16A
3A
40A
16A
6A
3A
0.4%
0.9%
0.9%
0.4%
0.7%
0.7%
0.4%
0.9%
0.4%
0.4%
0.9%
0.5%
0.4%
0.9%
0.9%
2%
0.8%
0.9%
0.9%
0.8%
0.7%
0.7%
0.8%
0.9%
1%
0.8%
0.9%
0.8%
0.8%
0.9%
0.9%
2%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
2.4%
4.98V to 5.02V
11.9V to 12.1V
11.9V to 12.1V
4.98V to 5.02V
14.9V to 15.1V
14.9V to 15.1V
4.98V to 5.02V
11.9V to 12.1V
4.98V to 5.02V
4.98V to 5.02V
11.9V to 12.1V
23.8V to 24.2V
4.98V to 5.02V
11.9V to 12.1V
11.9V to 12.1V
4.9V to 5.1V
1
PerFormanCe POWER PFC375
MULTIPLE OUTPUT MODEL SELECTION CHART (CONT.) - ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT (NOTE 1)
PEAK OUTPUT
CURRENT (NOTE 2)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 3)
INITIAL SETTING
ACCURACY
+5V
+12V
12V
12V
+5V
+12V
12V
24V
+5V
+12V
15V
15V
+5V
+12V
24V
24V
+24V
+5V
12V
12V
+24V
+5V
15V
15V
4.5V to 5.5V
11.3V to 12.6V
11.3V to 12.6V
11.0V to 16.0V
4.5V to 5.5V
11.3V to 12.6V
11.3V to 12.6V
22.0V to 28.0V
4.5V to 5.5V
11.3V to 12.6V
14.2V to 15.8V
14.2V to 15.8V
4.5V to 5.5V
11.3V to 12.6V
22.0V to 28.0V
22.0V to 28.0V
21.5V to 26.4V
4.5V to 5.5V
11.4V to 12.6V
11.4V to 12.6V
21.5V to 26.4V
4.5V to 5.5V
14.2V to 16.0V
13.7V to 16.0V
3.5 - 40A
10A
6A
3A
3.5 - 40A
10A
6A
3A
3.5 - 40A
10A
4A
4A
3.5 - 40A
10A
3A
3A
1 - 10A
10A
4A
4A
1 - 10A
10A
4A
4A
40A
16A
6A
3A
40A
16A
6A
3A
40A
16A
4A
4A
40A
16A
3A
3A
10A
16A
4A
4A
10A
16A
4A
4A
0.4%
0.9%
0.9%
0.9%
0.4%
0.9%
0.9%
0.5%
0.4%
0.9%
0.7%
0.7%
0.4%
0.9%
0.5%
0.5%
0.5%
0.4%
0.5%
0.5%
0.5%
0.4%
0.5%
0.5%
0.8%
0.9%
0.9%
0.9%
0.8%
0.9%
0.9%
0.8%
0.8%
0.9%
0.7%
0.7%
0.8%
0.9%
0.8%
0.8%
0.8%
0.8%
1%
1%
0.8%
0.8%
0.8%
0.8%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
4.98V to 5.02V
11.9V to 12.1V
11.9V to 12.1V
11.9V to 12.1V
4.98V to 5.02V
11.9V to 12.1V
11.9V to 12.1V
23.8V to 24.2V
4.98V to 5.02V
11.9V to 12.1V
14.9V to 15.1V
14.9V to 15.1V
4.98V to 5.02V
11.9V to 12.1V
23.8V to 24.2V
23.8V to 24.2V
23.8V to 24.2V
4.98V to 5.02V
11.9V to 12.1V
11.9V to 12.1V
23.8V to 24.2V
4.98V to 5.02V
14.9V to 15.1V
14.9V to 15.1V
+5V
+12V
PFC375-4500
Advanced Product Release 12V
5V
4.5V to 5.5V
11.3V to 12.6V
11.3V to 12.6V
4.5V to 5.5V
3.5 - 50A
10A
6A
3A
50A
16A
6A
3A
0.4%
0.9%
0.9%
2%
0.8%
0.9%
0.9%
0.9%
1%
1%
1%
1%
4.98V to 5.02V
11.9V to 12.1V
11.9V to 12.1V
4.9V to 5.1V
MODEL
PFC375-4001
PFC375-4002
PFC375-4004
PFC375-4005
(Note 4)
PFC375-4200
PFC375-4201
NOTES: 1)
2)
3)
4)
Output currents ratings are expressed with 300 LFM forced air.
Peak loads up to 450 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 450 Watts.
Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
V3 and V4 may be series connected to obtain 48V.
INPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-Up Time
Input Current
Input Protection
Inrush Surge Current
Continuous input range.
AC Input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Over full AC input voltage range at full rated load.
85 VAC at full rated load.
Non-user serviceable internally located AC input line fuse, F10A, 250V.
Internally limited by thermistor, one cycle, 25°C.
110 VAC
220 VAC
Per EN61000-3-2.
Switching frequency of main transformer.
85
47
85
20
Power Factor
Operating Frequency
2
NOM
MAX
UNITS
264
63
VAC
Hz
VAC
mS
ARMS
6
35
65
0.98
100
APK
W/VA
kHz
PerFormanCe POWER PFC375
OUTPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
Efficiency
Minimum Loads
Full rated load, 110 VAC. Varies with distribution of loads among outputs.
Single output models.
Multiple output models, 5V main output only.
Multiple output models, 24V main output only.
Full load, 20MHz bandwidth.
300 LFM forced air cooling required for operation. See optional fan.
Continuous power, multiple output models.
Peak power, all models.
Output voltage overshoot/undershoot at turn-on.
Varies by output. Total regulation includes: line changes from 85-132 VAC or
170-264 VAC, changes in load starting at 20% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100% load change,
3% max. deviation. (Main output only on multi-output units).
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
68
0
3.5
1
See Model Selection Charts
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-On Delay
Turn-On Rise Time
NOM
MAX
375
450
0
UNITS
%
Amps
Watts
V
See Model Selection Charts
1
mS
1
Sec
mS
MAX
UNITS
10
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
CONDITIONS/DESCRIPTION
Overvoltage Protection
Provided on single output units and the main output only of multiple output units.
PFC375-30XX, PFC375-40XX, PFC375-45XX
6.0
6.4
PFC375-1012
13.5
15.5
PFC375-1015
17.0
19.5
PFC375-1024
27.0
30.7
PFC375-1028
30.8
35.0
PFC375-1048
60.0
70.0
PFC375-42XX
27.0
30.7
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
System shutdown due to excessive internal temperature, automatic reset.
Total voltage compensation for cable losses with respect to the main output.
250
Accuracy of shared current with up to 6 parallel units.
10
TTL compatible logic signal will inhibit outputs by the application of a logic low signal.
An open circuit or external TTL high signal allows normal operation.
TTL compatible logic signal. Time before regulation dropout due to
5
loss of input power at 110 VAC.
TTL compatible signal. Signal is low if main output is greater or less than 10% of nominal.
Provides 170mA current to user supplied fan if fan option is not selected.
12
Overload Protection
Overtemperature Protection
Remote Sense
Current Share
Inhibit
Input Power
Fail Warning
Power Good
Fan Voltage
MIN
NOM
V
mV
%
mS
V
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Agency Approvals
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Input Transient Protection
UL1950.
CSA 22.2 NO. 234/950.
EN60950 (TÜV).
Input to output.
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 4.
Per EN61000-4-5 class 3.
Insulation Resistance
Leakage Current
Input to output.
Per EN60950, 264 VAC.
Dielectric Withstand Voltage
Electromagnetic Interference
MIN
NOM
MAX
Approved
Line to Line
Line to Ground
2600
B
B
8
10
±4
1
2
VDC
Class
kV
V/M
kV
kV
10
2.0
3
UNITS
MΩ
mA
PerFormanCe POWER PFC375
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Altitude
Operating.
Non-Operating.
MIN
Operating Temperature
At 100% load
At 50% load
Derate linearly above 50°C by 2.5% per °C.
Storage Temperature
Forced Air Cooling
Temperature Coefficient
Relative Humidity
Shock
Vibration
Forced air cooling of 300 LFM is required if the internal fan option is not specified.
Cooling air velocity is measured 1/4" above, at the middle of the chassis.
Airflow direction is from the input section to the output section.
0°C to 70°C (after 15 minute warm-up).
Non-Condensing.
Operating: 10±3mSec, 3 axis, Half Sine.
Non-operating: 10±3mSec, 3 axis, Half Sine.
Operating:
5-32Hz
32-2000Hz Sinusoidal
Non-operating:
NOM
0
0
-55
±0.02
5
MAX
UNITS
10k
40k
50
70
85
ASL Ft.
ASL Ft.
°C
°C
°C
±0.05
95
20
40
0.02
1
6.15
%/°C
%RH
G
in (DA)
GRMS
GRMS
OPTIONS
DESCRIPTION
NOTES
Fan
Add “F” as a suffix to the model number to order integral fan.
(provides required 300 LFM of forced air cooling).
Add “M” as a suffix to the model number to order chassis with
M4 x 0.7 mounting inserts.
Metric Mounting
SIZE IMPACT
10.50" x 5.00" x 2.50"
(266.7mm x 127.0mm x 63.5mm)
9.00" x 5.00" x 2.50"
(228.6mm x 127.0mm x 63.5mm)
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments,
or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are
subject to change without notice.
4
PerFormanCe POWER PFC375
OVERALL SIZE: 9.00" x 5.00" x 2.50" (228.6mm x 127.0mm x 63.5mm)
OVERALL LENGTH WITH FAN: 10.50" (266.7mm)
WEIGHT: 4.3 LBS (1.95 kg)
8-32 FLUSH NUT 8 PLACES
BOTH SIDES TYP.
WITH METRIC MOUNTING
OPTION: M4 X 0.7, 8 PLACES
2.50"
(63.5mm)
FAN OPTION
1.20"
(30.4mm)
9.00" (228.6mm)
1.50"
(38.1mm)
1. 25"
(31.8mm)
6.50" (165.1mm)
0.70"
(17.8mm)
5.00"
(127.0mm)
SUGGESTED AIR FLOW
3.900"
(99.1mm)
3.12"
(79.2mm)
(BOTTOM VIEW)
TERMINAL BLOCK
MAIN OUTPUT (PFC375-4200, PFC375-4201,
V1 ADJ
TB2 1
V2 ADJ
TB1
V3 ADJ
1
AC-L
AC-N
PIN 1
(V2) RTN
PIN 2
(V2)
PIN 3
(V3)
PIN 4
(V3) RTN
PIN 5
(V4)
PIN 6
(V4) RTN
PINS 3 & 4
(V1) RTN
V1 ADJ
V2 ADJ
V3 ADJ
CHASSIS GND
3
V4 ADJ
V4 ADJ
PIN 5
(V2) RTN
PIN 6
(V2)
PIN 7
(V3)
PIN 8
(V3) RTN
PIN 9
(V4)
PIN 10
(V4) RTN
J4
P4,P3,P5 Mating Housing:
Molex 5051
P4,P3,P5 Mating Terminals:
Molex 4809 or 40445
0.090" (2.3mm) ALUMINUM ALLOY, WITH CLEAR FINISH
5
J5
Customer connection:
INPUT & OUTPUT CONNECTIONS: 6-32 SCREW TERMINAL ON 0.375" (9.5mm) CENTERS
BUS BAR MAIN OUTPUT, E1 & E2, 10-32 SCREW TERMINAL
CHASSIS:
J3
N/C
FAN OPTION
(TOP VIEW)
PINS 1 & 2
(V1)
+SHARE
E2
(V1) RTN
AND ALL SINGLE OUTPUT
UNITS EXCEPT PFC375-1005)
PIN 1 SIG GND
PIN 2 PF
PIN 3 PWR GOOD
PIN 4 N/C
1
PIN 3 INHIBIT
TB3
PIN 4 +FAN
E1
(V1)
PIN 1 +SENSE
PIN 2 —SENSE
BUS BAR
MAIN OUTPUT