MAGNETROL 033-4741-002

Tuffy Liquid Level
Controls with
Pneumatic Switch
D E S C R I P T I O N
The Pneumatic Tuffy Liquid Level Switch is designed for
horizontal mounting in a tank or vessel through threaded
or flanged pipe connections. The single pneumatic switch
mechanism is used for high or low level alarm or control
applications.
F E A T U R E S
• All 316 SS wetted components
• Cage pressures to 2200 psig (151 bar)
• NACE and/or ASME B31.3 construction
• Specific gravity as low as 0.40
• 2" NPT mounting
O P T I O N S
• Process temperatures
from -40° to +300° F (-40° to +149° C)
• Commercially constructed external cage with two
1" NPT top and bottom connections
• ANSI flanges
T Y P I C A L
I N S T A L L A T I O N
• NACE or ASME B31.3 external cage with two 1" NPT
top and bottom connections available.
Consult factory
Shut–off
Valve
1/4" NPT
Air Line
Connections
Safety
Check
Valve
Pressure
Vessel
A P P L I C A T I O N S
• Sour service (NACE)
CL
CL
Shut–off
Valve
CL
Switch
Actuation
Level
• High/low alarm
• Day storage tanks
• Clean liquids
• Process vessels
Drain Valve
P R I N C I P L E
O F
O P E R A T I O N
Figures 1 and 2 illustrate the simple Magnetrol operating principle. Switching action is obtained through the use of a
magnet which is attached to a float and a switching mechanism. These two basic component assemblies are separated
by a non-magnetic, pressure tight barrier
Tuffy body
(Non-magnetic)
Magnet
pivot
Port B
Magnet
Pivot
Port B
Tuffy body
(Non-magnetic)
Magnet
pivot
Rising level
Float
Port A
Port A
Magnets
Spring
Spring
Valve
plunger
Valve
plunger
Pivot
Float
Falling level
Port C
Valve body
Port C
Valve body
Pivot arm
Figure 1
Low Level
Figure 2
High Level
3-way
2-way
Port
N.O.
N.C.
Diverter
Selector
N.O.
N.C.
A
Inlet
Exhaust
Outlet
Inlet
Inlet
Plug
B
Exhaust
Inlet
Outlet
Inlet
Plug
Inlet
C
Outlet
Outlet
Inlet
Outlet
Outlet
Outlet
D I M E N S I O N A L
P N E U M A T I C
Pivot arm
Note: Orientation of ports may
vary from unit to unit.
S P E C I F I C A T I O N S
S W I T C H
M O D E L S
12.00 (304) or 12.94 (329)
8.91 (226) [Sp. Gr. 0.4 Min.]
Float Size = 2.00 (51) Dia. x 5.12 (130) Long
7.96 (202) [Sp. Gr. 0.6 Min]
Float Size = 2.00 (51) Dia. x 4.57 (116) Long
Port B
1/4" NPT
3.00 (76) Max.
Nozzle Length
Port A
1/4" NPT
Switch Actuates
Rising Level
3.75 (95)
Float
.75
Minimum
(19)
Clearance
Falling Level
Switch Actuates
C
L
2.50 (64) Dia.
Port C
1/4" NPT
2" NPT
Optional accessories
(2) 1" NPT
0.56 (14) Dia. Holes [4]
on 3.62 (92) B.C.
2" NPT
1.31
(33)
4.50
(114)
Dia.
2" NPT
6.40
(163)
1.31
(33)
11.25 ± .12
(286 ± 3)
Cage
2
2" NPT
3.50
(89)
3.50
(89)
Square Flange
Flange Part No. 04-6804-001
Flange Rating: 250 psig @ +400° F
(17 bar @ +204° C)
ASME Flange
(Consult factory when
ordering)
M O D E L
N U M B E R
BASIC MODEL NUMBER
039
Tuffy Float Switch
SWITCH ACTION
6
Pneumatic
HOUSING
316 Stainless steel with 1⁄4" NPT airline connections
0
SPECIFIC GRAVITY AND PRESSURE RATINGS
0
3
9
6
0
0
0
1
0
0.60 minimum S.G., 1500 psi maximum pressure
4
0.40 minimum S.G., 500 psi maximum pressure
0
C H A M B E R
P A R T
N U M B E R
PRESSURE RATING
0
1
2200 psig @ +300° F, 1400 psig @ 750° F
1200 psig @ +300° F, 780 psig @ 750° F
MATERIALS OF CONSTRUCTION
1
2
0
3
3
M E C H A N I C A L
Pressure:
4
7
4
0
Carbon Steel
316 Stainless Steel
0
S P E C I F I C A T I O N S
0.6 SG 1500 psig at +300° F (103 bar at +149° C)
0.4 SG 500 psig at +300° F (34 bar at +149° C)
Process Temperature:
-40° to +300° F (-40° to 149° C)
Ambient Temperature:
Max. 100° F (38° C) with maximum process temperature
Pneumatic Switch Supply Pressure:
Vacuum to 200 psig (13.8 bar) maximum
Maximum Leakage Rate:
0.5 SCFH (0.015 SCMH @ 100 psig (6.9 bar))
Maximum Air Flow:
12.0 SCFH (0.34 SCMH @ 100 psig (6.9 bar))
Specific Gravity:
0.6 minimum or 0.4 minimum
Materials of Construction:
316/316L SS wetted components including NACE and ASME B31.3
Housing:
316 stainless steel
Cage (optional)
Carbon steel or stainless steel *
Cage Rating
Schedule 80
2200 psig at +300° F (151 bar at +149° C)
Schedule 40
1200 psig at +300° F (83 bar at +149° C)
* NACE or ASME B31.3 external cage available. Consult factory.
3
D E S C R I P T I O N
The quality assurance system in place at
Magnetrol guarantees the highest level of
quality throughout the company. Magnetrol
is committed to providing full customer
satisfaction both in quality products and
quality service.
The Magnetrol quality assurance system
is registered to ISO 9001 affirming its
commitment to known international
quality standards providing the strongest
assurance of product/service quality
available.
D E S C R I P T I O N
All Magnetrol electronic level and flow
at no cost to the purchaser (or owner)
controls are warranted free of defects in
materials or workmanship for five full years
from the date of original factory shipment.
other than transportation.
If returned within the warranty period;
and, upon factory inspection of the control, the cause of the claim is determined
to be covered under the warranty; then,
Magnetrol will repair or replace the control
damage or expense arising from the installation or use of equipment. There are no
other warranties expressed or implied,
except special written warranties covering
some Magnetrol products.
Magnetrol shall not be liable for misapplication, labor claims, direct or consequential
5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com
145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306
Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93
Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317
Copyright © 2011 Magnetrol International, Incorporated. All rights reserved. Printed in the USA.
Performance specifications are effective with date of issue and are subject to change without notice.
Magnetrol & Magnetrol logotype are registered trademarks of Magnetrol International.
BULLETIN: 44-109.3
EFFECTIVE: May 2007
SUPERSEDES: June 2003