MAGNETROL 080-8032-312

Kotron®
Tip Sensitive
RF Level Sensor
D E S C R I P T I O N
Kotron Tip Sensitive Level controls can be utilized in
liquid or bulk material applications. There are no moving
parts in contact with the medium. These units are integral
systems with the sensing probe mounted with the
electronics.
F E A T U R E S
• Integral NEMA 4X/7/9 aluminum enclosures
• Probe length can be field modified from 14" (356 mm)
standard length to a minimum of 4" (100 mm)
• 316 stainless steel probe
• Maximum pressure up to 3000 psig @ +100° F
(205 Bar @ +40° C)
• Dielectric constant as low as 2.0
• 5 amp SPST relay
• Field selectable fail-safe jumper wire
A P P L I C A T I O N
T E C H N O L O G Y
Economical solution for integral point sensor in:
As material covers the probe, there is a change in the
dielectric of the material surrounding the probe. This
creates an increase in capacitance which is detected by
the electronics and converted into a relay activation.
When the probe is uncovered, the capacitance is reduced
and the relay is reset.
• Liquids
• Slurries
• Dry bulk material
E L E C T R I C A L
S P E C I F I C A T I O N S
Supply voltage
120 VAC, +10%, -15%, 50–60 Hz
240 VAC, +10%, -15%, 50–60 Hz
24 VAC, ±10%
Power consumption
120 VAC, less than 5 volt-amps
240 VAC, less than 5 volt-amps
24 VAC, 1 watt maximum
Zero range
0 pF (minimum) to 350 pF (maximum)
Fixed minimum differential
0.5 pF minimum
Output relays
AC
(1) Reversible SPST 120/250 VAC, 5 amp resistive
DC
(1) Reversible SPST 30 VDC, 5 amp resistive
Response time
100 milliseconds
Repeatability
Better than 1.0%
Ambient temperature at electronics
-40° to 160° F (-40° to +70° C)
Operating pressure/temperature
3000 psig @ +100° F (205 Bar @ +40° C)
2100 psig @ +160° F (145 Bar @ +70° C)
450 psig @ +250° F (31 Bar @ +120° C) horizontal mount
450 psig @ +200° F (31 Bar @ +93° C) vertical mount
P R O B E
+0.05 pF per degree F (+0.09 pF per degree C)
L E N G T H
v s .
At the 14" (356 mm) standard length, the
probe will operate in any material with a
dielectric constant above 2.
A minimum probe length of 4" (102 mm) is
permissible in a conductive liquid (dielectric
of 24 or greater). The full length should be
maintained in a non-conductive liquid or
bulk material.
If the geometry of your application requires
a probe shorter than 14" (356 mm), refer to
the chart at right.
D I E L E C T R I C
Minimum required dielectric constant (epsilon) of material
Temperature coefficient
C O N S T A N T
27
26
25
24
26
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
4
5
6
7
8
9
10
11
Total probe length (Inches)
2
12
13
14
A G E N C Y
A P P R O V A L S
Agency
Model Approved
Protection Method
Area Classification
FM
080-8032-3X2
Explosion Proof
Class I, Div. 1, Groups A, B, C & D
Class II, Div. 1, Groups E, F & G
Class III, NEMA 4X
CSA
080-8032-3X2
Explosion Proof
Class I, Div. 1, Groups C & D
Class II, Div. 1, Groups E, F & G
Class III, TYPE 4X
M O D E L
T I P
N U M B E R
S E N S I T I V E
S W I T C H
INPUT POWER
0
1
2
0
8
0
8
0
3
D I M E N S I O N A L
I N C H E S
2
3
120 VAC; current less than .055 amp
240 VAC; current less than .035 amp
24 VDC; current less than .030 amp
2
S P E C I F I C A T I O N S
( M M )
3.44 (87)
Rotation
clearance
4.63
(117) Dia.
2.75
(70)
3/4" NPT
plugged
3/4" NPT
3.50 (89)
3/4" NPT
4.00 (102)
Min. length
14.00 (356)
(std. length)
.375 (10)
3
Q U A L I T Y
The quality assurance system in place at
Magnetrol guarantees the highest level of
quality throughout the company. Magnetrol
is committed to providing full customer
satisfaction both in quality products and
quality service.
Magnetrol’s quality assurance system is
registered to ISO 9001 affirming its commitment to known international quality
standards providing the strongest assurance
of product/service quality available.
All Kotron Tip Sensitive RF Level Sensors
are available for quick shipment, usually
within one week after factory receipt of a
purchase order, through the Expedite Ship
Plan (ESP).
ESP service may not apply to orders of ten
units or more. Contact your local representative for lead times on larger volume
orders, as well as other products and
options.
E S P
Expedite
Ship
Plan
W A R R A N T Y
All Magnetrol electronic level and flow
controls are warranted free of defects in
materials or workmanship for five full years
from the date of original factory shipment.
If returned within the warranty period;
and, upon factory inspection of the control, the cause of the claim is determined
to be covered under the warranty; then,
Magnetrol will repair or replace the control
at no cost to the purchaser (or owner)
other than transportation.
Magnetrol shall not be liable for misapplication, labor claims, direct or consequential
damage or expense arising from the installation or use of equipment. There are no
other warranties expressed or implied,
except special written warranties covering
some Magnetrol products.
For additional information, see Instruction Manual 50-606.
5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com
145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306
Heikenstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Telex 25944 • Fax 052 45.09.93
Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317
Copyright © 2003 Magnetrol International, Incorporated. All rights reserved. Printed in the USA.
Magnetrol and Magnetrol logotype are registered trademarks of Magnetrol International.
Performance specifications are effective with date of issue and are subject to change without notice.
The brand and product names contained within this document are trademarks or registered trademarks of their respective holders.
BULLETIN: 50-136.11
EFFECTIVE: February 2003
SUPERSEDES: July 2000