FERYSTER PLT18/10/2-3F45

FERROXCUBE
DATA
A SH
SHEET
EET
E18/4/10
Planar E cores and accessories
Supersedes data of February 2002
2004 Sep 01
Ferroxcube
Planar E cores and accessories
E18/4/10
CORES
Effective core parameters of a set of E cores
SYMBOL
PARAMETER
VALUE
UNIT
Σ(I/A)
core factor (C1)
0.616
mm−1
Ve
effective volume
960
mm3
Ie
effective length
24.3
mm
Ae
effective area
39.3
mm2
Amin
minimum area
39.3
mm2
m
mass of core half
≈ 2.4
g
18 ±0.35
handbook, halfpage
14 ±0.3
4 ±0.1
2 ±0.1
10 ±0.2
CBW297
R0.8 (12×)
Dimensions in mm.
Fig.1 E18/4/10 core half.
Effective core parameters of an E/PLT combination
SYMBOL
PARAMETER
VALUE
UNIT
Σ(I/A)
core factor (C1)
0.514
mm−1
Ve
effective volume
800
mm3
Ie
effective length
20.3
mm
Ae
effective area
39.5
mm2
Amin
minimum area
39.5
mm2
m
mass of plate
≈ 1.7
g
handbook, halfpage
18 ±0.35
2 ±0.05
Ordering information for plates
GRADE
TYPE NUMBER
3C90
PLT18/10/2-3C90
3C92
PLT18/10/2-3C92
3C93
PLT18/10/2-3C93
3C94
PLT18/10/2-3C94
3C96
PLT18/10/2-3C96
3F3
PLT18/10/2-3F3
3F35
PLT18/10/2-3F35
3F4
PLT18/10/2-3F4
3F45
PLT18/10/2-3F45
3E6
PLT18/10/2-3E6
2004 Sep 01
10 ±0.2
R0.8
CBW298
Dimensions in mm.
Fig.2 PLT18/10/2.
2
4 ±0.1
Ferroxcube
Planar E cores and accessories
E18/4/10
Core halves for use in combination with an non-gapped E core
AL measured in combination with a non-gapped core half, clamping force for AL measurements, 20 ±10 N, using a PCB
coil containing 4 layers of 8 tracks each, total height 1.6 mm.
GRADE
3C90
AL
(nH)
µe
100 ±3%
≈ 49
≈ 800
E18/4/10-3C90-A100-E
160 ±3%
≈ 78
≈ 420
E18/4/10-3C90-A160-E
250 ±5%
≈ 123
≈ 220
E18/4/10-3C90-A250-E
E18/4/10-3C90-A315-E
315 ±8%
AIR GAP
(µm)
TYPE NUMBER
≈ 154
≈ 170
3200 ±25%
≈ 1560
≈0
E18/4/10-3C90
3C92
2330 ±25%
≈ 1140
≈0
E18/4/10-3C92
3C93
2700 ±25%
≈ 1320
≈0
E18/4/10-3C93
3C94
100 ±3%
≈ 49
≈ 800
E18/4/10-3C94-A100-E
160 ±3%
≈ 78
≈ 420
E18/4/10-3C94-A160-E
250 ±5%
≈ 123
≈ 220
E18/4/10-3C94-A250-E
E18/4/10-3C94-A315-E
315 ±8%
3C96
3F3
3F35
3F4
≈ 154
≈ 170
3200 ±25%
≈ 1560
≈0
2900 ±25%
≈ 1410
≈0
≈ 49
≈ 800
E18/4/10-3F3-A100-E
160 ±3%
≈ 78
≈ 420
E18/4/10-3F3-A160-E
250 ±5%
≈ 123
≈ 220
E18/4/10-3F3-A250-E
315 ±8%
≈ 154
≈ 170
E18/4/10-3F3-A315-E
2700 ±25%
≈ 1320
≈0
E18/4/10-3F3
2200 ±25%
≈ 1070
≈0
E18/4/10-3F35
100 ±3%
E18/4/10-3C96
100 ±3%
≈ 49
≈ 800
E18/4/10-3F4-A100-E
160 ±3%
≈ 78
≈ 420
E18/4/10-3F4-A160-E
250 ±5%
≈ 123
≈ 220
E18/4/10-3F4-A250-E
315 ±8%
≈ 154
≈ 170
E18/4/10-3F4-A315-E
1550 ±25%
≈ 760
≈0
E18/4/10-3F4
≈ 760
≈0
E18/4/10-3F45
≈ 6600
≈0
E18/4/10-3E6
3F45
1550 ±25%
3E6
13500 +40/-30%
2004 Sep 01
E18/4/10-3C94
3
Ferroxcube
Planar E cores and accessories
E18/4/10
Core halves for use in combination with a plate (PLT)
AL measured in combination with a plate (PLT), clamping force for AL measurements, 20 ±10 N, using a PCB coil
containing 4 layers of 8 tracks each, total height 1.6 mm.
GRADE
3C90
AL()
(nH)
µe
100 ±3%
≈ 41
≈ 870
E18/4/10-3C90-A100-P
160 ±3%
≈ 65
≈ 470
E18/4/10-3C90-A160-P
250 ±5%
≈ 102
≈ 240
E18/4/10-3C90-A250-P
E18/4/10-3C90-A315-P
315 ±8%
AIR GAP
(µm)
TYPE NUMBER
≈ 129
≈ 170
3680 ±25%
≈ 1500
≈0
E18/4/10-3C90
3C92
2690 ±25%
≈ 1100
≈0
E18/4/10-3C92
3C93
3100 ±25%
≈ 1270
≈0
E18/4/10-3C93
3C94
100 ±3%
≈41
≈870
E18/4/10-3C94-A100-P
160 ±3%
≈65
≈470
E18/4/10-3C94-A160-P
250 ±5%
≈102
≈240
E18/4/10-3C94-A250-P
E18/4/10-C94-A315-P
315 ±8%
3C96
3F3
3F35
3F4
≈129
≈170
3680 ±25%
≈ 1500
≈0
3250 ±25%
≈ 1320
≈0
≈41
≈870
E18/4/10-3F3-A100-P
160 ±3%
≈65
≈470
E18/4/10-3F3-A160-P
250 ±5%
≈102
≈240
E18/4/10-3F3-A250-P
315 ±8%
≈129
≈170
E18/4/10-3F3-A315-P
3100 ±25%
≈ 1270
≈0
E18/4/10-3F3
2500 ±25%
≈ 1020
≈0
E18/4/10-3F35
100 ±3%
E18/4/10-3C96
100 ±3%
≈41
≈870
E18/4/10-3F4-A100-P
160 ±3%
≈65
≈470
E18/4/10-3F4-A160-P
250 ±5%
≈102
≈240
E18/4/10-3F4-A250-P
315 ±8%
≈129
≈170
E18/4/10-3F4-A315-P
1800 ±25%
≈ 740
≈0
E18/4/10-3F4
≈ 740
≈0
E18/4/10-3F45
≈ 6400
≈0
E18/4/10-3E6
3F45
1800 ±25%
3E6
15500 +40/-30%
2004 Sep 01
E18/4/10-3C94
4
Ferroxcube
Planar E cores and accessories
E18/4/10
Properties of core sets under power conditions
B (mT) at
CORE LOSS (W) at
H = 250 A/m;
f = 10 kHz;
T = 100 °C
f = 100 kHz;
ˆ = 100 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 400 kHz;
ˆ = 50 mT;
B
T = 100 °C
f = 500 kHz;
ˆ = 50 mT;
B
T = 100 °C
E+E18-3C90
≥320
≤ 0.105
−
−
−
E+PLT18-3C90
≥320
≤ 0.095
−
−
−
E+E18-3C92
≥370
≤ 0.085
≤ 0.6
−
−
E+PLT18-3C92
≥370
≤ 0.075
≤ 0.5
−
−
E+E18-3C93
≥320
≤ 0.085(1)
≤ 0.6(1)
−
−
E+PLT18-3C93
≥320
≤ 0.075(1)
≤ 0.5(1)
−
−
E+E18-3C94
≥320
≤ 0.085
≤ 0.6
−
−
E+PLT18-3C94
≥320
≤ 0.075
≤ 0.5
−
−
E+E18-3C96
≥320
≤ 0.065
≤ 0.45
≤ 0.18
≤ 0.35
E+PLT18-3C96
≥320
≤ 0.06
≤ 0.4
≤ 0.15
≤ 0.3
E+E18-3F3
≥300
≤ 0.11
−
≤ 0.19
−
E+PLT18-3F3
≥300
≤ 0.09
−
≤ 0.16
−
E+E18-3F35
≥300
−
−
≤ 0.09
≤ 0.13
E+PLT18-3F35
≥300
−
−
≤ 0.08
≤ 0.12
GRADE
1.
Measured at 140 °C.
Properties of core sets under power conditions (continued)
B (mT) at
CORE LOSS (W) at
H = 250 A/m;
f = 10 kHz;
T = 100 °C
f = 500 kHz;
ˆ = 100 mT;
B
T = 100 °C
f = 1 MHz;
ˆ = 30 mT;
B
T = 100 °C
f = 1 MHz;
ˆ = 50 mT;
B
T = 100 °C
f = 3 MHz;
ˆ = 10 mT;
B
T = 100 °C
E+E18-3F35
≥300
≤ 1.0
−
−
−
E+PLT18-3F35
≥300
≤ 0.9
−
−
−
E+E18-3F4
≥250
−
≤ 0.3
−
≤ 0.45
E+PLT18-3F4
≥250
−
≤ 0.24
−
≤ 0.39
E+E18-3F45
≥250
−
≤ 0.2
≤ 0.48
≤ 0.35
E+PLT18-3F45
≥250
−
≤ 0.16
≤ 0.4
≤ 0.3
GRADE
2004 Sep 01
5
Ferroxcube
Planar E cores and accessories
E18/4/10
MOUNTING INFORMATION
4.25
min.
R 0.8 max.
handbook, 4 columns
10.4
min.
13.5 max.
18.5 min.
CBW551
Fig.3 Recommended PCB cut-out for glued planar E18/4/10 cores.
2004 Sep 01
6
Ferroxcube
Planar E cores and accessories
E18/4/10
BLISTER TAPE AND REEL DIMENSIONS
K0
handbook, full pagewidth
P0
D0
T
P2
E
F
cover tape
B0
P1
For dimensions see Table 1.
Fig.4 Blister tape.
Table 1
Physical dimensions of blister tape; see Fig.4
SIZE
DIMENSIONS
(mm)
A0
10.5 ±0.2
B0
18.7 ±0.2
K0
4.5 ±0.2
T
0.3 ±0.05
W
32.0 ±0.3
E
1.75 ±0.1
F
14.2 ±0.1
D0
1.5 +0.1
D1
≥ 2.0
P0
4.0 ±0.1
P1
16.0 ±0.1
P2
2.0 ±0.1
S
28.4 ±0.1
2004 Sep 01
7
W
CBW404
D1
A0
S
direction of unreeling
Ferroxcube
Planar E cores and accessories
E18/4/10
cover film
handbook, full pagewidth
direction of
unreeling
blister tape
CBW405
Fig.5 Construction of blister tape.
direction of unreeling
leader 552 mm
handbook, full pagewidth
minimum number of
empty compartments
trailer
cover tape only
CBW406
Leader: length of leader tape is 552 mm minimum covered with cover tape.
Trailer: 160 mm minimum (secured with tape).
Storage temperature range for tape: −25 to +45 °C.
Fig.6 Leader/trailer tape.
2004 Sep 01
8
Ferroxcube
Planar E cores and accessories
E18/4/10
W2
handbook, full pagewidth
20.5
12.75
0.15
N
0
A
MSA284
W1
Dimensions in mm.
For dimensions see Table 2.
Fig.7 Reel.
Table 2
Reel dimensions; see Fig.7
DIMENSIONS (mm)
SIZE
32
2004 Sep 01
A
N
W1
W2
330
100 ±5
32.4
≤36.4
9
Ferroxcube
Planar E cores and accessories
E18/4/10
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2004 Sep 01
10