SHARP PR39MF22NSZ

PR36MF22NSZ/PR39MF22NSZ
PR36MF22NSZ/
PR39MF22NSZ
8-Pin DIP Type SSR for Low
Power Control
■ Features
■ Outline Dimensions
1. Compact 8-pin dual-in-line package type.
2. RMS ON-state current IT(rms):0.6A, 0.9A
3. Built-in zero-cross circuit.
4. High repetitive peak OFF-state voltage.
(VDRM:MIN. 600V)
5. Isolation voltage between input and output.
(Viso(rms):4kV)
6. Under preparation for UL and CSA.
2.54
8
6
5
A
Anode
mark
1
2
3
4
7.62±0.3
2.9±0.5
1. Various types of home appliances
3.25±0.5
■ Model Line-up
1.2±0.3
±0.5
0.5TYP. 3.5±0.5
9.66
(Model No.)
6.5±0.5
A
■ Applications
RMS ON-state current (rms)
0.6A
0.9A
(Unit : mm)
±0.25
Model No.
PR36MF22NSZ
PR39MF22NSZ
0.5±0.1
0.26±0.1
θ:0 to 13˚
θ
Internal connection Diagram
Output
Input
■ Absolute Maximum Ratings
*3
Parameter
Symbol
Forward current
IF
Reverse voltage
VR
*1
RMS ON-state PR36MF22NSZ
IT (rms)
current
PR39MF22NSZ
*2
Peak one cycle PR36MF22NSZ
Isurge
surge current PR39MF22NSZ
*1
Rating
50
6
0.6
0.9
6
9
(Ta=25°C)
Unit
mA
V
A
8
6
Zero-cross
circuit
1
2
1
2
A
Repetitive peak
OFF-state voltage
VDRM
600
V
Isolation voltage
Operating temperature
Storage temperature
Soldering temperature
Viso (rms)
Topr
Tstg
Tsol
4.0
−30 to +85
−40 to +125
260 (For 10s)
kV
°C
°C
°C
5
3
4
3
Cathode
Anode
Cathode
Cathode
4
5
6
8
G
T1
T2
Terminal 1 , 3 and 4 are common ones of cathode.To radiate the
heat, solder all of the lead pins on the pattern of PWB.
*1 The derating factors of absolute maximum ratings due to ambient temperature are
shown in Fig.1, 2
*2 50Hz sine wave
*3 AC for 1 min, 40 to 60%RH, f=60Hz
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://sharp-world.com/ecg/
PR36MF22NSZ/PR39MF22NSZ
■ Electrical Characteristics
Input
Output
Transfer
characteristics
Symbol
Parameter
VF
Forward voltage
Reverse current
IR
Repetitive peak OFF-state current
IDRM
PR36MF22NSZ
ON-state voltage
VT
PR39MF22NSZ
Holding current
IH
Critical rate of rise of OFF-state voltage
dV/dt
Zero-cross voltage
VOX
IFT
Minimum trigger current
Isolation resistance
RISO
Turn-on time
ton
Fig.1 RMS ON-state Current vs. Ambient
Temperature
MIN.
−
−
−
TYP.
1.2
−
−
MAX.
1.4
10
100
(Ta=25˚C)
Unit
V
µA
µA
−
−
3.0
V
−
100
−
−
5×1010
−
−
−
−
−
1011
−
25
−
35
5
mA
V/µs
−
50
V
mA
Ω
µs
Fig.2 RMS ON-state Current vs. Ambient
Temperature
PR36MF22NSZ
1
PR39MF22NSZ
0.6
RMS ON-state current IT (rms) (A)
RMS ON-state current IT (rms) (A)
0.7
Conditions
IF=20mA
VR=3V
VD=VDRM
IT=0.6A
IT=0.9A
VD=6V
−
VD=1/√2 • VDRM
IF=10mA, R load
VD=6V, RL=100Ω
DC=500V, 40 to 60%RHF
VD=6V, RL=100Ω, IF=10mA
0.5
0.4
0.3
0.2
0.8
0.6
0.4
0.2
0.1
0
−30 −20 −10 0
10 20 30 40 50 60 70 80 90 100
Ambient temperature Ta (˚C)
Fig.3 Forward Current vs. Ambient
Temperature
70
Forward current IF (mA)
60
50
40
30
20
10
0
−30 −20 −10 0
10 20 30 40 50 60 70 80 90 100
Ambient temperature Ta (˚C)
0
−30 −20 −10 0 10 20 30 40 50 60 70 80 90 100
Ambient temperature Ta (˚C)
NOTICE
●
The circuit application examples in this publication are provided to explain representative applications of SHARP
devices and are not intended to guarantee any circuit design or license any intellectual property rights. SHARP takes
no responsibility for any problems related to any intellectual property right of a third party resulting from the use of
SHARP's devices.
●
Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. SHARP
reserves the right to make changes in the specifications, characteristics, data, materials, structure, and other contents
described herein at any time without notice in order to improve design or reliability. Manufacturing locations are
also subject to change without notice.
●
Observe the following points when using any devices in this publication. SHARP takes no responsibility for damage
caused by improper use of the devices which does not meet the conditions and absolute maximum ratings to be used
specified in the relevant specification sheet nor meet the following conditions:
(i) The devices in this publication are designed for use in general electronic equipment designs such as:
- - - Personal computers
- -- Office automation equipment
- -- Telecommunication equipment [terminal]
- - - Test and measurement equipment
- - - Industrial control
- -- Audio visual equipment
- -- Consumer electronics
(ii) Measures such as fail-safe function and redundant design should be taken to ensure reliability and safety when
SHARP devices are used for or in connection with equipment that requires higher reliability such as:
- -- Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc.)
- - - Traffic signals
- - - Gas leakage sensor breakers
- - - Alarm equipment
- -- Various safety devices, etc.
(iii)SHARP devices shall not be used for or in connection with equipment that requires an extremely high level of
reliability and safety such as:
- - - Space applications
- -- Telecommunication equipment [trunk lines]
- -- Nuclear power control equipment
- -- Medical and other life support equipment (e.g., scuba).
●
Contact a SHARP representative in advance when intending to use SHARP devices for any "specific" applications
other than those recommended by SHARP or when it is unclear which category mentioned above controls the
intended use.
●
If the SHARP devices listed in this publication fall within the scope of strategic products described in the Foreign
Exchange and Foreign Trade Control Law of Japan, it is necessary to obtain approval to export such SHARP devices.
●
This publication is the proprietary product of SHARP and is copyrighted, with all rights reserved. Under the copyright
laws, no part of this publication may be reproduced or transmitted in any form or by any means, electronic or
mechanical, for any purpose, in whole or in part, without the express written permission of SHARP. Express written
permission is also required before any use of this publication may be made by a third party.
●
Contact and consult with a SHARP representative if there are any questions about the contents of this publication.