100W Single Output with Battery Charger(UPS Function) PSC-100 series Features : Universal AC input / Full range 5"x3" compact size Optional L-Bracket and cover (PSC-100x-C, x=A,B) Protections: Short circuit / Overload / Over voltage Battery low protection / Battery polarity protection by fuse Relay contact signal output for AC OK and Battery Low Cooling by free air convection 100% full load burn-in test 2 years warranty SPECIFICATION MODEL OUTPUT PSC-100A CH1 CH2 CH1 CH2 DC VOLTAGE 13.8V 13.8V 27.6V 27.6V RATED CURRENT 4.75A 2.5A 2.4A 1.25A CURRENT RANGE 0 ~ 7A -------- 0 ~ 3.5A -------- RATED POWER 100.05W VOLTAGE ADJ. RANGE CH1: 24 ~ 29V 1.0% --------------- LOAD REGULATION 0.5% -------- 0.5% -------- Note.5 2400ms, 30ms/230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE 40ms/230VAC 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz 2400ms, 30ms/115VAC at full load 16ms/115VAC at full load 127 ~ 370VDC 88% EFFICIENCY (Typ.) 86% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2A/115VAC 1.2A/230VAC COLD START 35A/115VAC 70A/230VAC LEAKAGE CURRENT <1mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1:14.49 ~ 18.63V CH1:28.98 ~ 37.26V Protection type : Shut down o/p voltage, re-power on to recover AC OK 20 1V 10 0.5V Note.6 Relay contact output, ON : AC OK ; OFF : AC Fail ; Max. rating : 30V / 1A BATTERY LOW WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE NOTE -------- 0.5% BATTERY CUT OFF OTHERS -------- -------- OVER VOLTAGE (Note 4) 100mVp-p 0.5% PROTECTION EMC CH1: 12 ~ 15V 1.0% -------- LINE REGULATION SETUP, RISE TIME ALARM FUNCTION 100.74W RIPPLE & NOISE (max.) Note.2 100mVp-p VOLTAGE TOLERANCE Note.3 INPUT PSC-100B OUTPUT NUMBER Relay contact output, OFF : Battery OK ; ON : Battery Low ; Max. rating : 30V / 1A Battery low voltage : < 11V -20 ~ +70 (Refer to "Derating Curve") Battery low voltage : < 22V 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0~50 ) on CH1 output 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE EMC EMISSION I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A DIMENSION PACKING 417.6K hrs min. MIL-HDBK-217F (25 ) PCB:127*76.2*31mm (L*W*H) ; with optional CASE:130*85*37mm (L*W*H) PCB:0.23Kg; 63pcs/15.5Kg/1.35CUFT ; with optional CASE:0.44Kg;32pcs/15Kg/0.64CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 6. Please refer to suggest application (2) (4) in page 3. 7. Heat sink HS2,HS3 can not be shorted. 8. Heat sink HS2,HS3 must have safety isolation distance from system case. File Name:PSC-100-SPEC 2011-08-18 PSC-100 100W Single Output with Battery Charger(UPS Function) Mechanical Specification series Unit:mm 5.7 Optional cover: No. 946B-T CN2 64.75 1 2 3 4 5 6 7 8 1 2 3 CN3 4 FS1 3 2 1 CN1 SVR1 HS2 HS3 4115.8 5.6 3.8 Mylar film 18 31max. 127 7.1 2-M3 L=4 115.8 2-M3 37 3max. 76.2 AC FUSE T3.15A/250V 6-M3 L=4 8.2 78 AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 Assignment AC/N No Pin AC/L Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Assignment -V +V Bat+ Bat- 62 6 17 7 85 26 Alarm Output Connector(CN3) : JST B4B-XH or equivalent DC Output Connector (CN2) : JST B8P-VH or equivalent Pin No. 1,2 3,4 5,6 7,8 130 Optional L-Bracket: No. 946A-D 41. 8.6 Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Pin No. Assignment 1 2 Mating Housing Terminal JST XHP or equivalent JST SXH-001T-P0.6 or equivalent AC OK 3 4 Bat. Low 1.HS2,HS3 can not be shorted. 2.HS2,HS3 must have safety isolation distance from system case. 3.-V and Bat- can not be shorted. Block Diagram RL1 AC OK RL2 Bat. Low ALARM CIRCUIT I/P EMI FILTER & RECTIFIER POWER SWITCHING FG O.L.P. PWM CONTROL RECTIFIERS & FILTER +V -V Bat. + DETECTION CIRCUIT O.V.P. Bat. Battery Charger & Back up Control File Name:PSC-100-SPEC 2011-08-18 100W Single Output with Battery Charger(UPS Function) Output Derating PSC-100 series Output Derating VS Input Voltage 100 100 PCB only 90 80 For PCB with L-Bracket+cover option 70 LOAD (%) LOAD (%) 60 50 40 20 -20 PCB only For PCB with L-Bracket+cover option 80 0 10 20 30 40 50 60 60 50 40 70 (HORIZONTAL) 90 95 100 115 AMBIENT TEMPERATURE ( ) 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz Suggested Application 1.Back up connection for AC interruption (1) Please refer to the Fig1.1 for suggested connection. The power supply charge the battery and provide energy to the load in the same time when the AC main is OK. The battery start to supply power to the load when the AC main fails. -V +V + Load Bat+ Bat- + - A : 12V B : 24V Battery Fig 1.1 Suggested system connection 2.Alarm signal for AC OK and Battery Low (1) Alarm signal is sent out through " AC OK " & " Battery Low " pins.(relay contact type) (2) An external voltage source is required for this function. The maximum applied voltage is 30V and the maximum sink current is 1A. (3) Table2.1 explain the alarm function built-in the power supply Function AC OK Battery Low Output of Alarm Description AC OK (Battery low) CN3 Pin1(Pin3) The signal is "Low" when the power supply turns on Low or short The signal turns to be "High" when the power supply turns OFF High or open(External applied voltage 30V max.) The signal is "Low" when the voltage of battery is under A:11V, B:22V Low or short The signal is "High" when the voltage of battery is above A:11V, B:22V High or open(External applied voltage 30V max.) R V CN3 Pin2(Pin4) Table 2.1 Explanation of Alarm Signal (4) RL1 (AC OK)signal will go into hiccup mode when the overload protection is activating. External voltage source (V) and resistor (R) (The max. Sink is 1A and 30V) Fig 2.2 Internal circuit of AC OK (Battery Low) File Name:PSC-100-SPEC 2011-08-18