MEANWELL PSC-60A

60W Single Output with Battery Charger(UPS Function)
PSC-60
series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Battery low protections / Battery polarity protection by fuse
Alarm signal for AC OK and Bat. low
Cooling by free air convection
100% full load burn-in test
2 years warranty
SPECIFICATION
OUTPUT
INPUT
OUTPUT NUMBER
CH1
CH2
CH1
CH2
DC VOLTAGE
13.8V
13.8V
27.6V
27.6V
RATED CURRENT
2.8A
1.5A
1.4A
0.75A
CURRENT RANGE
0 ~ 4.3A
--------
0 ~ 2.15A
--------
RATED POWER
59.34W
RIPPLE & NOISE (max.) Note.2 120mVp-p
CH1: 12 ~ 15V
VOLTAGE TOLERANCE Note.3 1.0%
NOTE
--------
--------
0.5%
--------
LOAD REGULATION
0.5%
--------
0.5%
--------
SETUP, RISE TIME
800ms, 50ms/230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
50ms/230VAC
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
1600ms, 50ms/115VAC at full load
10ms/115VAC at full load
127 ~ 370VDC
84%
EFFICIENCY (Typ.)
84%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.6A/115VAC
1A/230VAC
COLD START 30A/115VAC
60A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVERLOAD
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1:14.49 ~ 18.63V
CH1:28.98 ~ 37.26V
BATTERY CUT OFF
Protection type : Hiccup mode, recovers automatically after fault condition is removed
21 1V
10.5 0.5V
AC OK
TTL open collector output, ON : AC OK ; OFF : AC Fail ; Ice : max. 30mA@ 50VDC
BATTERY LOW
VIBRATION
OTHERS
--------
CH1: 24 ~ 29V
1.0%
--------
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
(Note 4)
240mVp-p
0.5%
WORKING TEMP.
EMC
--------
LINE REGULATION
OVER VOLTAGE
SAFETY &
59.34W
VOLTAGE ADJ. RANGE
PROTECTION
FUNCTION
PSC-60B
PSC-60A
MODEL
SAFETY STANDARDS
WITHSTAND VOLTAGE
TTL open collector output, ON : Battery Low ; OFF : Battery OK ; Ice : max. 30mA@ 50VDC
Battery low voltage < 22V
Battery low voltage < 11V
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0~50 ) on CH1 output
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
HARMONIC CURRENT
/ 70% RH
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
DIMENSION
PACKING
101.6*50.8*29mm (L*W*H)
0.13Kg; 96pcs/13.5Kg/0.89CUFT
589.7K hrs min.
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Heat Sink HS1,HS2 can not be shorted.
7. Heat Sink HS1 must have safety isolation distance with system case.
File Name:PSC-60-SPEC 2008-11-04
PSC-60
60W Single Output with Battery Charger(UPS Function)
Mechanical Specification
series
Unit:mm
101.6
3.175
95.25
3.175
HS2
FS1
50.8
44.45
3
2
1
AC FUSE
T2.5A/250V
SVR1
1
2
3
4
5
6
CN1
CN2
HS1
29
4- 3.3
3 max.
1.HS1,HS2 can not be shorted.
2.HS1 must have safety isolation distance
with system case.
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No.
1
2
3
Assignment
AC/N
No Pin
AC/L
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
DC Output Connector (CN2) : JST B6P-VH or equivalent
Pin No.
1
2
3
Assignment
Bat. Low
AC OK
Battery -
Pin No. Assignment
Battery +
4
DC Output +
5
6
DC Output COM
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
Block Diagram
AC OK
Bat. Low
ALARM
CIRCUIT
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
Bat. +
Bat. -
DETECTION
CIRCUIT
FG
Battery Charger
&
Back up Control
CONTROL
O.L.P.
O.V.P.
Output Derating VS Input Voltage
Output Derating
Ta=25
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-20
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
60
50
40
90
95
100
115
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:PSC-60-SPEC 2008-11-04